Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “buffer gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Buffer Gas Acquisition and Storage

The acquisition and storage of buffer gases (primarily argon and nitrogen) from the Mars atmosphere provides a valuable resource for blanketing and pressurizing fuel tanks and as a buffer gas for breathing air for manned missions. During the acquisition of carbon dioxide (CO2), whether by sorption bed or cryo-freezer, the accompanying buffer gases build up in the carbon dioxide acquisition system, reduce the flow of CO2 to the bed, and lower system efficiency. It is this build up of buffer gases that provide a convenient source, which must be removed, for efficient capture Of CO2 Removal of this buffer gas barrier greatly improves the charging rate of the CO2 acquisition bed and, thereby, maintains the fuel production rates required for a successful mission. Consequently, the acquisition, purification, and storage of these buffer gases are important goals of ISRU plans. Purity of the buffer gases is a concern e.g., if the CO, freezer operates at 140 K, the composition of the inert gas would be approximately 21 percent CO2, 50 percent nitrogen, and 29 percent argon. Although there are several approaches that could be used, this effort focused on a hollow-fiber membrane (HFM) separation method. This study measured the permeation rates of CO2, nitrogen (ND, and argon (Ar) through a multiple-membrane system and the individual membranes from room temperature to 193K and 10 kpa to 300 kPa. Concentrations were measured with a gas chromatograph that used a thermoconductivity (TCD) detector with helium (He) as the carrier gas. The general trend as the temperature was lowered was for the membranes to become more selective, In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar.

Parrish, Clyde F.↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments, Part II: On-line studies with short-lived accelerator-produced radionuclides

We report a novel combination of advanced gas-chromatography and detection systems coupled to a buffer-gas cell was characterized on-line to allow gas-phase chemical studies of accelerator-produced short-lived α -decaying mercury, francium, and astatine isotopes. These were produced in 40 Ar- and 48 Ca-induced nuclear fusion–evaporation reactions, subsequently isolated in the recoil separators MARS at Texas A&M University, USA, and TASCA at GSI Darmstadt, Germany, before being thermalized in a buffer-gas-stopping cell. From the latter, the nuclear reaction products were extracted into gas-phase chromatographic systems, suitable for registering α-decaying short-lived radionuclides, such as isotopes of superheavy elements. Efficiencies of 21(3)% for 204-209 Fr were reached for the extraction into the optimized miniCOMPACT gas-chromatography setup, indicating that this technique enables the identification of isotopes of volatile as well as non-volatile elements. These studies guide the path towards chemical investigations of superheavy elements beyond flerovium, which are out of reach with currently used setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light and buffer-gas frequency shifts in the Rb-85 maser frequency standard.

The effect of buffer gas and pumping light on the output frequency of the Rb-85 maser is discussed. In contrast to a primary standard, these frequency shifts can be used to advantage when it is necessary to operate the maser at a frequency which differs from the ground-state hyperfine frequency by a few kilohertz. Using appropriate mixtures of buffer gas and carefully shaped lamp spectral profiles, it is also possible to operate the maser exactly at the ground-state hyperfine frequency. It is pointed out that the short-term phase stability of the maser is not impaired by these shifts.

Stern, W. A.↗

Room temperature buffer gas beam of metastable state titanium atoms

We produce beams of neutral titanium (Ti) atoms in their metastable 3d3(F4)4sa5F5 state by laser ablation into He, N2, and Ar buffer gases. The high temperatures associated with the ablation process populate the a5F5 level without the need for optical pumping. Remarkably, we observe that Ti atoms in the a5F5 state survive thousands of collisions with He and Ar buffer gas atoms without being quenched to lower-energy states. We study the yield of Ti atoms when ablated into buffer gases of varying species and pressure, quantify quenching rates and diffusion cross sections based on simple models, and provide insight into optimal design parameters for an ablation cell. Using a 3.3 cm ablation cell with interchangeable exit apertures, we produce metastable atom beams and quantify their brilliance and velocity distributions as functions of buffer gas pressure.

Schrott, Jackson↗

Neon as a Buffer Gas for a Mercury-Ion Clock

A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump is used to maintain the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a buffer gas. Neon was determined to be the best choice for the buffer gas: The pressure-induced frequency pulling by neon was found to be only about two-fifths of that of helium. Furthermore, because neon diffuses through solids much more slowly than does helium, the operational lifetime of a tube backfilled with neon could be considerably longer than that of a tube backfilled with helium.

Prestage, John↗

Detection of individual atoms in helium buffer gas and observation of their real-time motion

Single atoms are detected and their motion measured for the first time to our knowledge by the fluorescence photon-burst method in the presence of large quantities of buffer gas. A single-clipped digital correlator records the photon burst in real time and displays the atom's transit time across the laser beam. A comparison is made of the special requirements for single-atom detection in vacuum and in a buffer gas. Finally, the probability distribution of the bursts from many atoms is measured. It further proves that the bursts observed on resonance are due to single atoms and not simply to noise fluctuations.

Pan, C. L.↗

A buffer-gas trap for the NEPOMUC positron beam: optimization studies with electrons

Buffer-gas traps (BGTs) use inelastic interactions with nitrogen molecules to capture positrons from a continuous beam. These devices are invaluable for high-resolution studies of matter–antimatter interactions, antihydrogen research and positronium laser spectroscopy. We present a new project with the goal of producing a non-neutral plasma containing ${\sim }10^8$ low-energy positrons by installing a BGT on the NEPOMUC (NEutron induced POsitron source MUniCh) high-intensity positron beam. Details of the BGT are outlined and results are presented from experiments in which an electron beam, with a similar intensity and energy spread to the remoderated NEPOMUC beam, was used to create pulses of non-neutral electron plasma. The device is a vital component of the APEX (A Positron Electron eXperiment) project, which aims to create a low-temperature electron–positron pair plasma.

Physics↗

High-resolution laser-induced fluorescence spectroscopy of 28 Si 16 O + and 29 Si 16 O + in a cryogenic buffer-gas cell

Here, the electronic, laser-induced fluorescence spectrum of the B 2 Σ + ← X 2 Σ + transition in 28 Si 16 O + and 29 Si 16 O + has been recorded in a cryogenic buffer gas cell at K. Molecular constants are extracted for both 28 Si 16 O + and 29 Si 16 O + , including the Fermi contact hyperfine constant for both the B and X states of 29 Si 16 O + , and used in a discussion of the suitability of SiO in future quantum information experiments.

47 OTHER INSTRUMENTATION↗

The Buffer-Gas Positron Accumulator and Resonances in Positron-Molecule Interactions

This is a personal account of the development of our buffer-gas positron trap and the new generation of cold beams that these traps enabled. Dick Drachman provided much appreciated advice to us from the time we started the project. The physics underlying trap operation is related to resonances (or apparent resonances) in positron-molecule interactions. Amusingly, experiments enabled by the trap allowed us to understand these processes. The positron-resonance "box score" to date is one resounding "yes," namely vibrational Feshbach resonances in positron annihilation on hydrocarbons; a "probably" for positron-impact electronic excitation of CO and NZ;an d a "maybe" for vibrational excitation of selected molecules. Two of these processes enabled the efficient operation of the trap, and one almost killed it in infancy. We conclude with a brief overview of further applications of the trapping technology discussed here, such as "massive" positron storage and beams with meV energy resolution.

Surko, C.M.↗

Spectroscopy on the A 1 Π←X 1 Σ + Transition of Buffer-Gas Cooled AlCl

Aluminum monochloride (AlCl) has been proposed as an excellent candidate for laser cooling. Here we present absorption spectroscopy measurements on the A 1 Π←X 1 Σ + transition in AlCl inside a cryogenic helium buffer-gas beam cell. The high resolution absorption data enables a rigorous, quantitative comparison with our high-level ab initio calculations of the electronic and rovibronic energies, providing a comprehensive picture of the AlCl quantum structure. Further, the combination of high resolution spectral data and theory permits the evaluation of spectroscopic constants and associated properties, like equilibrium bond length, with an order of magnitude higher precision. Based on the measured molecular equilibrium constants of the A 1 Π state, we estimate a Franck-Condon factor of the A 1 Π←X 1 Σ + of 99.88%, which confirms that AlCl is amenable to laser cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Slow Eigen-Zundel Interconversion in H + (H 2 O) 6 Clusters upon Isomer-Selective Vibrational Excitation and Buffer Gas Cooling in a Cryogenic Ion Trap

The formation of isomers when trapping floppy cluster ions in a temperature-controlled ion trap is a generally observed phenomenon. This involves collisional quenching of the ions initially formed at high temperature by buffer gas cooling until their internal energies fall below the barriers in the potential energy surface that separate them. Here we explore the kinetics at play in the case of the two isomers adopted by the H + (H 2 O) 6 cluster ion that differ in the proton accommodation motif. One of these is most like the Eigen cation with a tricoordinated hydronium motif (denoted E), and the other is most like the Zundel ion with the proton equally shared between two water molecules (denoted Z). After initial cooling to about 20 K in the radiofrequency (Paul) trap, the relative populations of these two spectroscopically distinct isomers are abruptly changed through isomer-selective photoexcitation of bands in the OH stretching region with a pulsed (~6 ns) infrared laser while the ions are in the trap. We then monitor the relaxation of the vibrationally excited clusters and reformation of the two cold isomers by recording infrared photodissociation spectra with a second IR laser as a function of delay time from the initial excitation. The latter spectra are obtained after ejecting the trapped ions into a time-of-flight photofragmentation mass spectrometer, thus enabling long (~0.1 s) delay times. Excitation of the Z isomer is observed to display long-lived vibrationally excited states that are collisionally cooled on a ms time scale, some of which quench into the E isomer. These excited E species then display spontaneous interconversion to the Z form on a ~10 ms time scale. Furthermore, these qualitative observations set the stage for a series of experimental measurements that can provide quantitative benchmarks for theoretical simulations of cluster dynamics and the potential energy surfaces that underlie them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗