Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “brazing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser Brazing of High Temperature Braze Alloy

The Space Shuttle Main Engine (SSME) consists of 1080 conical tubes, which are furnace brazed themselves, manifolds, and surrounding structural jacket making almost four miles of braze joints. Subsequent furnace braze cycles are performed due to localized braze voids between the coolant tubes. SSME nozzle experiences extremely high heat flux (180 mW/sq m) during hot fire. Braze voids between coolant tubes may result in hot combustion gas escape causing jacket bulges. The nozzle can be disqualified for flight or result in mission failure if the braze voids exceed the limits. Localized braze processes were considered to eliminate braze voids, however, damage to the parent materials often prohibited use of such process. Being the only manned flight reusable rocket engine, it has stringent requirement on the braze process. Poor braze quality or damage to the parent materials limits the nozzle service life. The objective of this study was to develop a laser brazing process to provide quality, localized braze joints without adverse affect on the parent materials. Gold (Au-Cu-Ni-Pd-Mn) based high temperature braze alloys were used in both powder and wire form. Thin section iron base superalloy A286 tube was used as substrate materials. Different Laser Systems including CO2 (10.6 micrometers, 1kW), ND:YAG (1.06 micrometers, 4kW). and direct diode laser (808nm. 150W) were investigated for brazing process. The laser process variables including wavelength. laser power, travel speed and angle of inclination were optimized according to bead geometry and braze alloy wetting at minimum heat input level, The properties of laser brazing were compared to that of furnace brazing. Microhardness profiles were used for braze joint property comparison between laser and furnace brazing. The cooling rate of laser brazing was compared to furnace brazing based on secondary dendritic arm spacing, Both optical and Scanning Electron Microscope (SEM) were used to evaluate the microstructures of the braze materials and tube substrate. Metallography of the laser braze joint was compared to the furnace braze. SEM Energy Disperse X-Ray Spectra (EDX) and back scattered imaging were used to analyze braze alloy segregation. Although all of the laser systems, CO2, ND:YAG, and direct diode laser produced good braze joint, the direct diode laser was selected for its system simplicity, compactness and portability. Excellent laser and braze alloy coupling is observed with powder alloy compared to braze alloy wire. Good wetting is found with different gold based braze alloys. The laser brazing process can be optimized so that the adverse affect on the parent materials can be eliminated. Metallography of the laser braze joint has shown that quality braze joint was produced with laser brazing process. Penetration of the laser braze to the substrate is at neglectable level. Zero penetration is observed. Microstructure examinations shown that no observable changes of the microstructure (grain structure and precipitation) in the HAZ area between laser braze and furnace braze. Wide gaps can be laser brazed with single pass for up to 0.024 inches. Finer dendritic structure is observed in laser brazing compared with equiaxial and coarser grain of the furnace brazing microstructure. Greater segregation is also found in the furnace braze. Higher hardness of the laser braze joint comparing to furnace braze is observed due to the fast cooling rate and Finer microstructure in the laser brazing. Laser braze joint properties meet or exceed the furnace joint properties. Direct diode laser for thin section tube brazing with high temperature braze alloys have been successfully demonstrated. The laser's high energy density and precise control has shown significant advantages in reducing process heat input to the substrates and provide high quality braze joints comparing to other localized braze process such as torch, TIG, and MPTA processes. Significant cost savings can be realized particularly with localized braze comparing to a full furnace braze cycle.

Gao, Y. P.↗

Brazing characteristics, microstructure, and wettability of laser powder bed fusion additive manufactured GRCop-84 compared to CuCrZr and OFC, and brazing to titanium-zirconium-molybdenum alloy limiters

Laser Powder Bed Fusion (L-PBF) of Glenn Research Copper 84 (GRCop-84), a Cr 2 Nb (8 at. % Cr, 4 at. % Nb) precipitation hardened alloy, produces a fully dense, high conductivity alloy with a yield strength of 500 MPa and ultimate tensile strength (UTS) of 740 MPa with 20% elongation; superior to other competing copper alloys. Braze wetting characteristics of GRCop-84 with Ag-Cu-X, and Au-Cu brazes were similar to CuCrZr, but less than oxygen free copper. No difference in wetting was observed between infill and surface contour areas in L-PBF GRCop-84. Wet sanding to 240 grit (R a =0.24 µm) was considered the optimal surface condition. Silver diffusing through GRCop-84 depleted Cr 2 Nb precipitates from the copper grain and deposited agglomerations of coarsened precipitates within silver-rich regions of intergranular diffusion once a density threshold was reached. Microstructure modification was minimized with 50Au-50Cu braze implying that silver caused precipitate coarsening and agglomeration, and not high temperature exposure. Coarsened precipitates were observed on the surface within braze pools implying a contribution to braze wetting. Palcusil-25, Ticusil, CuSil-ABA, and 50Au-50Cu brazes were suitable for brazing to unplated Titanium-Zirconium-Molybdenum (TZM), while sulfamate nickel plating to allows wetting with CuSil or other non-active brazes. Additionally, vacuum brazing techniques were developed to join a 1 mm thick layer of TZM to the front of additive manufactured GRCop-84 waveguides considering the brazing characteristics of both GRCop-84, TZM, and internal stress from the difference in coefficient in thermal expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Metal Brazing and Characterization of Brazed Joints in Titanium to Carbon-Carbon Composites

The Ti-metal/C-C composite joints were formed by reactive brazing with three commercial brazes, namely, Cu-ABA, TiCuNi, and TiCuSiI. The joint microstructures were examined using optical microscopy and scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS). The results of the microstructure analysis indicate solute redistribution across the joint and possible metallurgical bond formation via interdiffusion, which led to good wetting and spreading. A tube-on-plate tensile test was used to evaluate joint strength of Ti-tube/ C-C composite joints. The load-carrying ability was greatest for the Cu-ABA braze joint structures. This system appeared to have the best braze spreading which resulted in a larger braze/C-C composite bonded area compared to the other two braze materials. Also, joint loadcarrying ability was found to be higher for joint structures where the fiber tows in the outer ply of the C-C composite were aligned perpendicular to the tube axis when compared to the case where fiber tows were aligned parallel to the tube axis.

Singh, M.↗

Brazed Joints Design and Allowables: Discuss Margins of Safety in Critical Brazed Structures

This slide presentation tutorial discusses margins of safety in critical brazed structures. It reviews: (1) the present situation (2) definition of strength (3) margins of safety (4) design allowables (5) mechanical testing (6) failure criteria (7) design flowchart (8) braze gap (9) residual stresses and (10) delayed failures. This presentation addresses the strength of the brazed joints, the methods of mechanical testing, and our ability to evaluate the margins of safety of the brazed joints as it applies to the design of critical and expensive brazed assemblies.

FLom, Yury↗

Brazing of Stainless Steels to Yttria Stabilized Zirconia (YSZ) Using Silver -Base Brazes

Three silver-base brazes containing either noble metal palladium (Palcusil-10 and Palcusil-15) or active metal titanium (Ticusil) were evaluated for high-temperature oxidation resistance, and their effectiveness in joining yttria stabilized zirconia (YSZ) to a corrosion-resistant ferritic stainless steel. Thermogravimetric analysis (TGA), and optical- and scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS) were used to evaluate the braze oxidation behavior and the structure and chemistry of the YSZ/braze/steel joints. The effect of the braze type and processing conditions on the interfacial microstructure and composition of the joint regions is discussed with reference to the chemical changes that occur at the interface. It was found that chemical interdiffusion of the constituents of YSZ, steel and the brazes led to compositional changes and/or interface reconstruction, and metallurgically sound joints.

Singh, Mrityunjay↗

Active Metal Brazing and Characterization of Brazed Joints in C-C and C-SiC Composites to Copper-Clad-Molybdenum System

Carbon/carbon composites with CVI and resin-derived matrices, and C/SiC composites reinforced with T-300 carbon fibers in a CVI SiC matrix were joined to Cu-clad Mo using two Ag-Cu braze alloys, Cusil-ABA (1.75% Ti) and Ticusil (4.5% Ti). The brazed joints revealed good interfacial bonding, preferential precipitation of Ti at the composite/braze interface, and a tendency toward delamination in resin-derived C/C composite. Extensive braze penetration of the inter-fiber channels in the CVI C/C composites was observed. The Knoop microhardness (HK) distribution across the C/C joints indicated sharp gradients at the interface, and a higher hardness in Ticusil than in Cusil-ABA. For the C/SiC composite to Cu-clad-Mo joints, the effect of composite surface preparation revealed that ground samples did not crack whereas unground samples cracked. Calculated strain energy in brazed joints in both systems is comparable to the strain energy in a number of other ceramic/metal systems. Theoretical predictions of the effective thermal resistance suggest that such joined systems may be promising for thermal management applications.

Singh, M.↗

Method for eliminating runout of braze filler metal during active brazing

Nanometers thick conformal coatings deposited by atomic-layer deposition (ALD) onto the metal surface of an active braze joint modifies the surface chemistry to eliminate excess braze filler metal flow. Unlike other means used to prevent braze filler metal runout, the thin ALD coating does not hinder next assembly processes, does not require post-braze cleaning, and does not alter the base material mechanical properties.

Goeke, Ronald S.↗

DEVELOPMENT OF A LIGHT-WEIGHT REGENERATIVELY COOLED THRUST CHAMBER WITH BRAZED RIBS AND BRAZED OUTER WIRE TRAP

Design and fabrication procedures are discussed of a brazed-ribtype thrust chamber fabricated from stainless steel or inconel for a Sooo-lb thrust 20: 1 expansion-area-ratio regeneratively cooled liquidpropellant rocket engine which is designated as the JPL 6K Engine and operates at a chamber pressure of 150 psia. Hydrazine is used as the fuel and regenerative coolant and nitrogen tetroxide as the oxidizer. The nozzle-throat diameter is 5.42 in. The thrust chamber consists of a sheet-metal gas-side liner with longitudinal ribs spotwelded and brazed to the outer surface. Wire is wrapped over the ribs circumferentially, spot-welded to the ribs, and brazed. The liner, ribs, and wire form the coolant-passage walls. There are three basic advantages to this type of thrust chamber: light weight, ease of fabrication, and comparatively low cost. The total dry weight of a thrust chamber of this type and size made of 347 stainless steel is 46.2 lb, and the wet weight is 56.3 Ib. A total of 87 static engine tests were made on 19 of 23 thrust chambers fabricated by this technique. Four of the chambers tested had an expansion-area ratio of 20:1, and 15, which were shorter but had the same throat diameter, had an expansion-area ratio of 3.5:l. Accumulated test time was 1926 sec, including 558 sec regenerative cooling with hydrazine and 1368 sec cooling with water. One 20:l thrust chamber was subjected to 16 separate engine tests, with an accumulated test time of 399 sec, and was still in very good operating condition after the tests were completed. With water flowing through the coolant passages at 10 lb/sec, the measured nominal pressure drop between coolant manifolds of a 20:l thrust chamber wrapped with flat wire was 17.2 psi.

Thrust Chamber↗

Brazing of Stainless Steel to Yttria-Stabilized Zirconia Using Gold-Based Brazes for Solid Oxide Fuel Cell Applications

Two gold-base active metal brazes (gold-ABA and gold-ABA-V) were evaluated for oxidation resistance to 850 C, and used to join yttria-stabilized zirconia (YSZ) to a corrosion-resistant ferritic stainless steel for possible use in solid oxide fuel cells. Thermogravimetric analysis and optical microscopy and scanning electron microscopy coupled with energy-dispersive spectroscopy were used to evaluate the braze oxidation behavior, and microstructure and composition of the YSZ/braze/steel joints. Both gold-ABA and gold-ABA-V exhibited nearly linear oxidation kinetics at 850 C, with gold-ABA-V showing faster oxidation than gold-ABA. Both brazes produced metallurgically sound YSZ/steel joints due to chemical interactions of Ti and V with the YSZ and steel substrates.

Singh, M.↗

Influence of oxygen on performance of multi-principal element alloy as braze filler for Ni-base alloys

In manufacturing of multi-principal element alloys (MPEAs), the casting process is often a primary point of oxygen introduction to the material system, which was demonstrated by the laboratory scale button arc-melting process. Oxygen introduction raises concerns for the mechanical performance of these alloys if employed as structural materials alone or in engineering applications, such as serving as filler materials to enable joining of similar or dissimilar alloy pairs that are conventionally considered difficult to join. In this work, oxide inclusions in an as-cast off-equiatomic MnFeCoNiCu MPEA and Ni-base alloy braze joints made with this MPEA were evaluated by synchrotron x-ray diffraction mapping and electron microscopy. MnO was found to be prevalent throughout the cast MPEA and was chemically reduced during brazing by trace Al from the base material, Ni-base Alloy 600. Incomplete reaction of the MnO with Al, and some alternative reaction with Cr, left a mixture of MnO, Al 2 O 3 , and Cr 2 O 3 in the as-brazed joint, with the oxides concentrated near the braze centerline due to directional solidification. Further, in the braze joints, the non-oxide constituent phases detected were an FCC matrix and particles of Cr 23 C 6 , Cr 7 C 3 , and TiN which are all native to Alloy 600. The evolution of oxides within the brazed joints at elevated service temperatures of 600-800°C was also evaluated. While MnO and Al 2 O 3 were stable during high-temperature service, Cr 2 O 3 particles grew to several hundred microns, with dissolved oxygen in the MPEA providing a significant source for oxide growth. Comparing tensile performance of the as-brazed condition with post-service conditions showed that the evolution of oxide particles contributed to an increase in strength and decrease in ductility of the brazed joints. Evaluating particle morphologies among fracture surfaces of individual specimens demonstrated that large Cr 2 O 3 particles and continuous cluster networks of Al 2 O 3 were the features most detrimental to total elongation. Hence, unmitigated evolution of oxygen-containing species during brazing and service conditions is detrimental to the ductility of the brazed joints, which highlights the importance of oxygen control in initial manufacturing of MPEAs for engineering applications.

36 MATERIALS SCIENCE↗

Development of the weld-braze joining process

A joining process, designated weld-brazing, was developed which combines resistance spot welding and brazing. Resistance spot welding is used to position and aline the parts, as well as to establish a suitable faying-surface gap for brazing. Fabrication is then completed at elevated temperature by capillary flow of the braze alloy into the joint. The process was used successfully to fabricate Ti-6Al-4V alloy joints by using 3003 aluminum braze alloy and should be applicable to other metal-braze systems. Test results obtained on single-overlap and hat-stiffened panel specimens show that weld-brazed joints were superior in tensile shear, stress rupture, fatigue, and buckling compared with joints fabricated by conventional means. Another attractive feature of the process is that the brazed joint is hermetically sealed by the braze material, which may eliminate many of the sealing problems encountered with riveted or spot welded structures. The relative ease of fabrication associated with the weld-brazing process may make it cost effective over conventional joining techniques.

Bales, T. T.↗

Flaw Tolerance in Lap Shear Brazed Joints

Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

Flom, Yury↗