Mold bolt and means for achieving close tolerances between bolts and bolt holes

In the space shuttle, a cargo bay storage rack was required which was to be manufactured from a metal-plastic composite and bolted to a cargo structure. Following completion, utilization of the rack was disallowed due to tolerances, that is, the size differences between the outside bolt diameter and the inside hole diameter. In addition to the space shuttle problem there are other close tolerance requirements for bolts. Such environments often benefit from close tolerance bolting. Frequently such fabrication is not cost effective. Consequently there is a need for means of achieving close tolerances between bolts and bolt holes. Such means are provided. After compressing the elements together a strong rigid plastic, ceramic, or ceramic plastic fluid is forced into a channel extending through the bolt.

Johnston, David L.↗

Piezoelectric Bolt Breakers and Bolt Fatigue Testers

A proposed family of devices for inducing fatigue in bolts in order to break the bolts would incorporate piezoelectric actuators into resonant fixtures as in ultrasonic/ sonic drills/corers and similar devices described in numerous prior NASA Tech Briefs articles. These devices were originally intended primarily for use as safer, more-reliable, more-versatile alternatives to explosive bolts heretofore used to fasten spacecraft structures that must subsequently be separated from each other quickly on command during flight. On Earth, these devices could be used for accelerated fatigue testing of bolts. Fatigue theory suggests that a bolt subjected to both a constant-amplitude dynamic (that is, oscillatory) stress and a static tensile stress below the ultimate strength of the bolt material will fail faster than will a bolt subjected to only the dynamic stress. This suggestion would be applied in a device of the proposed type. The device would be designed so that the device and the bolt to be fatigue-tested or broken would be integral parts of an assembly (see figure). The static tension in the tightened bolt would apply not only the clamping force to hold the joined structures (if any) together but also the compression necessary for proper operation of the piezoelectric actuators as parts of a resonant structural assembly. The constant-amplitude dynamic stress would be applied to the bolt by driving the piezoelectric actuators with a sinusoidal voltage at the resonance frequency of longitudinal vibration of the assembly. The amplitude of the excitation would be made large enough so that the vibration would induce fatigue in the bolt within an acceptably short time. In the spacecraft applications or in similar terrestrial structural-separation applications, devices of the proposed type would offer several advantages over explosive bolts: Unlike explosive bolts, the proposed devices would be reusable, could be tested before final use, and would not be subject to catastrophic misfire. In fatigue-testing applications, devices of the proposed type would offer advantages of compactness and low cost, relative to conventional fatigue- testing apparatuses. In both structural- separation and fatigue-testing applications, bolts to be broken or tested could be instrumented with additional ultrasonic transducers for monitoring of pertinent physical properties and of fatigue failure processes.

Sherrit, Stewart↗

Laboratory pull-out tests on fully grouted rock bolts and cable bolts: Results and lessons learned

Laboratory pull-out tests were conducted on the following rock bolts and cable bolts: steel rebars, smooth steel bars, fiberglass reinforced polymer threaded bolts, flexible cable bolts, IR5/IN special cable bolts and Mini-cage cable bolts. The diameter of the tested bolts was between 16 mm and 26 mm. The bolts were grouted in a sandstone sample using resin or cement grouts. The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample. In most tests, the rate of displacement was about 0.02 mm/s. The tests were performed using a pull-out bench that allows testing a wide range of parameters. This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response (rock bolts and cable bolts). Furthermore, it also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole, which cannot be neglected when the test results are used to assess the bolt-grout or the grout–rock interface.

42 ENGINEERING↗

A Method to Capture Macroslip at Bolted Interfaces [PowerPoint]

Relative motion at bolted connections can occur for large shock loads as the internal shear force in the bolted connection overcomes the frictional resistive force. This macroslip in a structure dissipates energy and reduces the response of the components above the bolted connection. There is a need to be able to capture macroslip behavior in a structural dynamics model. A linear model and many nonlinear models are not able to predict marcoslip effectively. The proposed method to capture macroslip is to use the multi-body dynamics code ADAMS to model joints with 3-D contact at the bolted interfaces. This model includes both static and dynamic friction. The joints are preloaded and the pinning effect when a bolt shank impacts a through hole inside diameter is captured. Substructure representations of the components are included to account for component flexibility and dynamics. This method was applied to a simplified model of an aerospace structure and validation experiments were performed to test the adequacy of the method.

42 ENGINEERING↗

Thermal conductance measurements of bolted copper joints for SuperCDMS

Joint thermal conductance testing has been undertaken for bolted copper to copper connections from 60 mK to 26 K. This testing was performed to validate an initial design basis for the SuperCDMS experiment, where a dilution refrigerator will be coupled to a cryostat via multiple bolted connections. Copper used during testing was either gold plated or passivated with citric acid to prevent surface oxidation. Results obtained are well fit by a power law regression of joint thermal conductance to temperature and match well with data collected during a literature review.

Schmitt, R.↗

Bolt installation tool for tightening large nuts and bolts

Large bolts and nuts are accurately tightened to structures without damaging torque stresses. There are two models of bolt installation tool. One is rigidly mounted and one is hand held. Each model includes torque-multiplier unit.

Mcdougal, A. R.↗

Reducing Bolt Preload Variation with Angle-of-Twist Bolt Loading

Critical high-pressure sealing joints on the Space Shuttle reusable solid rocket motor require precise control of bolt preload to ensure proper joint function. As the reusable solid rocket motor experiences rapid internal pressurization, correct bolt preloads maintain the sealing capability and structural integrity of the hardware. The angle-of-twist process provides the right combination of preload accuracy, reliability, process control, and assembly-friendly design. It improves significantly over previous methods. The sophisticated angle-of-twist process controls have yielded answers to all discrepancies encountered while the simplicity of the root process has assured joint preload reliability.

Thompson, Bryce↗

Microstructural Characterization of the Second High Fluence Baffle-Former Bolt Retrieved from a Westinghouse Two-loop Downflow Type PWR

As one of the pressurized water reactor (PWR) internal components, baffle-former bolts (BFBs) are subjected to significant mechanical stress and neutron irradiation from the reactor core during the plant operation. Over the long operation period, these conditions lead to potential degradation and reduced load-carrying capacity of the bolts. In support of evaluating long-term operational performance of materials used in core internal components, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, Materials Research Pathway (MRP) has harvested two high fluence BFBs from a commercial Westinghouse two-loop downflow type PWR. The two bolts of interest, i.e. bolts # 4412 and 4416, were withdrawn from service in 2011 as part of a preventative replacement plan. No identification of cracking or potential damage was found for these bolts during their removal in 2011. However, the bolts required a lower torque for removal from the baffle structure than the original torque specified during installation. Irradiation displacement damage levels in the bolts range from 15 to 41 displacements per atom. The goal of this project is to perform detailed microstructural and mechanical property characterization of BFBs following in-service exposures. The information from these bolts will be integral to the LWRS program initiatives in evaluating end of life microstructure and properties. Furthermore, valuable data will be obtained that can be incorporated into model predictions of long-term irradiation behavior and compared to results obtained in high flux experimental reactor conditions. In this report, we present our latest study in FY22 on microstructural characterizations of the second high fluence baffle-former bolt, i.e., bolt # 4412. Analytical electron microscopy and atom probe tomography characterization were performed. The radiation-induced defects in the material add to the large wealth of knowledge for neutron-induced defects in 304/316 grades of stainless steels, specifically for radiation-induced precipitation after high fluence commercial PWR irradiation. The main findings are summarized as follows: 1) The cavity size was considerably larger in the bolt thread section than in the bolt head, with the bolt thread section having a bimodal distribution of cavities greater than ~6 nm in diameter and less than ~3 nm in diameter. The bolt head only had the small-sized cavities. In addition, there was a denuded zone of large cavities near grain boundaries in the thread section of the bolt. 2) Radiation-induced precipitation in the BFB #4412 was highly complex, with the volume fraction, size, and number density of Ni/Si and Cu-rich precipitates depending strongly on the radiation temperature/dose. In many cases, co-precipitates of adjoined clusters were found with Ni/Si-rich precipitates sandwiched between Cu-rich clusters and Mo/Cr/P-rich clusters. 3) Solute segregation out of solution was highest for most solutes in the thread section of the bolt #4412 with the exception of Cu, which experienced more separation out of solution into Curich clusters in the bolt head section. This highlights the difference in the mechanisms for precipitation of Ni/Si clusters, which have the Ni 3 Si phase composition, and precipitation of Cu-rich clusters. 4) There appear to be multiple simultaneous influences that affect the microstructural variation along the length of the bolt that overcomes the ~2X difference in irradiation dose between the bolt head and the bolt thread. The irradiation temperature, thermal/fast neutron ratio variation, potential strain gradient, and exposure to PWR coolant water that each section of the bolt sees may have more influence on the microstructural evolution than the total irradiation dose. The bolt thread and shank, with higher temperature, higher relative fast neutron flux, higher strain, and exposure to coolant but lower dose, underwent more enhanced cavity formation, precipitation, and solute segregation than the bolt head section.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post-Service Examination of PWR Baffle Bolts, Part I. Examination and Test Plan

In support of extended service and current operations of the US nuclear reactor plants, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, is coordinating with Ginna Nuclear Power Plant, The Westinghouse Electric Company, LLC, and ATI Consulting, the selective procurement of baffle bolts that were withdrawn from service in 2011 and currently stored on site at Ginna. The goal of this program is to perform detailed microstructural and mechanical property characterization of baffle former bolts following in-service exposures. This report outlines the selection criteria of the bolts and the techniques to be used in this study. The bolts available are the original alloy 347 steel fasteners used in holding the baffle plates to the baffle former structures within the lower portion of the pressurized water reactor vessel. Of the eleven possible bolts made available for this work, none were identified to have specific damage. The bolts, however, did show varying levels of breakaway torque required in their removal. The bolts available for this study varied in peak fluence (highest dose within the head of the bolt) between 9.9 and 27.8x10 21 n/cm 2 (E>1MeV). As no evidence for crack initiation was determined for the available bolts from preliminary visual examination, two bolts with the higher fluence values were selected for further post-irradiation examination. The two bolts showed different breakaway torque levels necessary in their removal. The information from these bolts will be integral to the LWRS program initiatives in evaluating end of life microstructure and properties. Furthermore, valuable data will be obtained that can be incorporated into model predictions of long-term irradiation behavior and compared to results obtained in high flux experimental reactor conditions. The two bolts selected for the ORNL study will be shipped to Westinghouse with bolts of interest to their collaborative efforts with the Electric Power Research Institute. Westinghouse will section the ORNL bolts into samples specified in this report and return them to ORNL. Samples will include bend bars for fracture toughness and crack propagation studies along with thin sections from which specimens for bend testing, subscale tensile and microstructural analysis can be obtained. Additional material from the high stress concentration region at the transition between the bolt head and shank will also be preserved to allow for further investigation of possible crack initiation sites.

42 ENGINEERING↗

Ultrasonic Measurement and Monitoring of Loads in Bolts used in Structural Joints

The paper is an overview of work by the author in measuring and monitoring loads in bolts using an ultrasonic extensometer. A number of cases of bolted joints are covered. These include, a clamped joint with clearance fit between the bolt and hole, a clamped joint with the bolt in an interference fit with the hole, a flanged joint which allows the flange and bolt to bend; and a shear joint in a clevis and tang configuration. These applications were initially developed for measuring and monitoring preload in the NASA Space Shuttle Orbiter critical joints but are also applicable for monitoring loads in other critical bolted joints of structures such as transportation bridges and other aerospace structures. The paper explains how to set‐up a model to estimate the load factor and accuracy for the ultrasonic preload application in a clamped joint with clearance fit. The ultrasonic preload application for clamped joint with bolt in an interference fit can also be used to measure diametrical interference between the bolt shank and hole; and interference pressure on the bolt shank. Model and experimental data are given to demonstrate use of ultrasonic measurements in a shear joint. A bolt in a flanged joint experiences both tensile and bending loads. This application involves measurement of bending and tensile preload in a bolt. The ultrasonic beam bends due to the bending load on the bolt. A numerical technique to compute the trace of ultrasonic ray is presented.

Koshti, Ajay↗

NASA's Radio Frequency Bolt Monitor: A Lifetime of Spinoffs

This story begins in the 1970s, when Dr. Joseph Heyman, a young scientist at NASA s Langley Research Center, was asked to support the investigation of a wind tunnel accident at a sister center. Although the work was outside of his physics background, it sparked a research focus that guided his lengthy NASA career and would earn him a slew of accolades, including NASA s highest award medals for Exceptional Leadership, Exceptional Achievement, and Exceptional Service; the coveted Silver Snoopy Astronaut Award for Space Shuttle Return to Flight; and the Arthur Fleming Award for being one of the Top Ten Federal Scientists in Government Service. He won 30 additional NASA awards, including the Agency s Invention of the Year and the Agency s highest award for technology transfer, and was the only person to ever win 4 R&D 100 Awards. Back in 1973, though, Heyman was a young civil servant with a background in physics who was asked to sit on an accident review panel. The panel met at Ames Research Center, in Moffet Field, California, and after considerable investigation, concluded that a high-pressure pebble heater used for heating gas had failed, due to improperly tightened bolts in a 1,000-pound gate valve control section. The accident showered the facility with incendiary ceramic spheres and nearly a ton of metal, but, luckily, caused no injuries. Heyman returned to Langley and began work on a solution. He developed an ultrasonic device that would measure bolt elongation, as opposed to torque, the factor typically measured in testing bolt preload or tension. Torque measurement can lead to load errors, with miscalculations as high as 80 percent that can be passed over during installation. Bolt stretch, however, is nearly always accurate to 1 percent or better. Within 1 month, he had an acoustic resonance solution that accurately determined bolt elongation. He assumed his work on this project had ended, but it was actually the start of nearly 15 years of work perfecting, improving, inventing, and modifying the "bolt monitor", all the while, filing numerous patents, presenting papers, and holding demonstrations as the technology matured. Industry engineers challenged Heyman s inventiveness, and reminded the physicist that most bolts are not perfect resonators, and that early devices required that the bolt have reasonably flat and parallel faces. The U.S. Geological Survey asked NASA for help in determining the load in mine roof bolts, which are 8- to 10-feet-long and rough cut. To solve that problem, Heyman modified the original device to operate at a lower frequency and to generate propagation modes that could be used to "lock" the instrument on a particular mode. Further work in this vein led to the development of the Pulsed Phase Locked Loop (P2L2) that worked on the mine bolts. The next set of problems involved high-strength bolts with head markings. For this solution, Heyman invented a modified P2L2 that tracked a specific phase point in the measurement wave. This class of instrumentation, well suited to measuring small changes in acoustic velocity, won the NASA "Invention of the Year" award in 1982. Other scientists and engineers have continued the evolution of this technology both inside NASA and outside of the Agency. Within NASA, the technology has been improved for medical applications, with a particular focus on intercranial pressure (ICP) monitoring.

Source record↗

Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor

The bolt tensile and joint separation loads are directly influenced by the locations at which the external loads enter the clamped members of a preloaded bolted joint (PBJ) and the associated load-paths through the joint. This physical load introduction mechanism affecting the bolt tensile loading is typically represented in the bolt tensile load equation, in part, by a load introduction factor (LIF), which was shown by H.M. Lee of Marshall Spaceflight Center to be a natural product of the bolt tensile load equation using a linear spring stiffness model. This LIF, being a function of load-path stiffness, has subsequently been denoted as the stiffness-based LIF (SBLIF), providing a framework to calculate the LIF using whatever load-path stiffness approximations are appropriate. Expanding upon the work of Lee, it is shown that the SBLIF and the joint stiffness factor are functions of the stiffnesses of the same load-paths and regions within a PBJ, and thus they should not be treated as independent variables. Mathematical expressions for the SBLIF are presented. Comparisons are shown between the analytically calculated SBLIF, the analytically calculated geometric LIF (GLIF), which is a simple clamped-member thickness ratio, the experimentally derived LIF, and the LIF determined by finite element analysis (FEA). Using experiment and FEA as a benchmark, the SBLIF, using traditional load-path stiffness approximations, enables a more accurate prediction of bolt tensile loading than the GLIF, although it can be unconservative near joint separation. The GLIF generally attributes more of the externally applied tensile load to the bolt than does the SBLIF, potentially resulting in heavier and/or more costly bolted joints. Mathematical relationships between the SBLIF and the GLIF are developed. Supplemental material is provided in the appendixes where the historical practice of using the joint compressive stiffness in place of the joint tensile stiffness is evaluated. The appendixes include step-by-step examples demonstrating the calculation of the SBLIF using traditional stiffness approximations and conclude with the development of the joint diagram in terms of the SBLIF, culminating into formulas for the key features of a joint diagram, which is useful for programming.

Load Path↗

Combined In-Plane and Through-the-Thickness Analysis for Failure Prediction of Bolted Composite Joints

Although two-dimensional methods provide accurate predictions of contact stresses and bolt load distribution in bolted composite joints with multiple bolts, they fail to capture the effect of thickness on the strength prediction. Typically, the plies close to the interface of laminates are expected to be the most highly loaded, due to bolt deformation, and they are usually the first to fail. This study presents an analysis method to account for the variation of stresses in the thickness direction by augmenting a two-dimensional analysis with a one-dimensional through the thickness analysis. The two-dimensional in-plane solution method based on the combined complex potential and variational formulation satisfies the equilibrium equations exactly, and satisfies the boundary conditions and constraints by minimizing the total potential. Under general loading conditions, this method addresses multiple bolt configurations without requiring symmetry conditions while accounting for the contact phenomenon and the interaction among the bolts explicitly. The through-the-thickness analysis is based on the model utilizing a beam on an elastic foundation. The bolt, represented as a short beam while accounting for bending and shear deformations, rests on springs, where the spring coefficients represent the resistance of the composite laminate to bolt deformation. The combined in-plane and through-the-thickness analysis produces the bolt/hole displacement in the thickness direction, as well as the stress state in each ply. The initial ply failure predicted by applying the average stress criterion is followed by a simple progressive failure. Application of the model is demonstrated by considering single- and double-lap joints of metal plates bolted to composite laminates.

Kradinov, V.↗

Bolt Stress Monitor

In photo, an engineer is using a new Ultrasonic Bolt Stress Monitor developed by NASA's Langley Research Center to determine whether a bolt is properly tightened. A highly accurate device, the monitor is an important tool in construction of such structures as pressure vessels, bridges and power plants, wherein precise measurement of the stress on a tightened bolt is critical. Overtightened or undertightened bolts can fail and cause serious industrial accidents or costly equipment break-downs. There are a number of methods for measuring bolt stress. Most widely used and least costly is the torque wrench, which is inherently inaccurate; it does not take into account the friction between nut and bolt, which has an influence on stress. At the other end of the spectrum, there are accurate stress-measuring systems, but they are expensive and not portable. The battery-powered Langley monitor fills a need; it is inexpensive, lightweight, portable and extremely accurate because it is not subject to friction error. Sound waves are transmitted to the bolt and a return signal is received. As the bolt is tightened, it undergoes changes in resonance due to stress, in the manner that a violin string changes tone when it is tightened. The monitor measures the changes in resonance and provides a reading of real stress on the bolt. The device, patented by NASA, has aroused wide interest and a number of firms have applied for licenses to produce it for the commercial market.