Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine Learning-Enabled Wearable Piezoelectric Acoustic Sensor for Real-Time Breast Abnormality Detection

In contemporary society, breast health has become a significant public health concern, particularly among women. According to statistics from the World Health Organization, both the incidence and mortality rates of breast tumors have steadily increased in recent years. Therefore, effective early-stage screening and postoperative monitoring are essential for maintaining breast health. However, conventional clinical diagnostic modalities are typically bulky, operationally complex, and unsuitable for continuous real-time monitoring, which limits their use in portable and everyday health management applications. To address these limitations, this study proposes a machine learning-integrated wearable piezoelectric sensing platform as an auxiliary tool for breast health assessment. The device consists of a PDMS matching layer embedded with flexible silver nanowires, a P(VDF-TrFE) piezoelectric layer, and a multi-channel low-noise signal acquisition circuit. It is capable of acquiring acoustic echo signals from tissue-mimicking environments and automatically evaluating signal validity using a convolutional neural network (CNN). By integrating piezoelectric sensing with deep learning-based signal analysis, the proposed system achieves a signal-to-noise ratio exceeding 70 dB and a real-time classification accuracy above 96% under controlled conditions. These results demonstrate that the platform provides a compact, portable, and intelligent approach for wearable sensing of mechanical heterogeneity and highlight its potential for future development in continuous biomedical monitoring technologies.

He, Shuaitong↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Magnetoimpedance Biosensors and Real-Time Healthcare Monitors: Progress, Opportunities, and Challenges

A small DC magnetic field can induce an enormous response in the impedance of a soft magnetic conductor in various forms of wire, ribbon, and thin film. Also known as the giant magnetoimpedance (GMI) effect, this phenomenon forms the basis for the development of high-performance magnetic biosensors with magnetic field sensitivity down to the picoTesla regime at room temperature. Over the past decade, some state-of-the-art prototypes have become available for trial tests due to continuous efforts to improve the sensitivity of GMI biosensors for the ultrasensitive detection of biological entities and biomagnetic field detection of human activities through the use of magnetic nanoparticles as biomarkers. In this review, we highlight recent advances in the development of GMI biosensors and review medical devices for applications in biomedical diagnostics and healthcare monitoring, including real-time monitoring of respiratory motion in COVID-19 patients at various stages. We also discuss exciting research opportunities and existing challenges that will stimulate further study into ultrasensitive magnetic biosensors and healthcare monitors based on the GMI effect.

60 APPLIED LIFE SCIENCES↗

Engineering advancements in microfluidic systems for enhanced mixing at low Reynolds numbers

Mixing within micro- and millichannels is a pivotal element across various applications, ranging from chemical synthesis to biomedical diagnostics and environmental monitoring. The inherent low Reynolds number flow in these channels often results in a parabolic velocity profile, leading to a broad residence time distribution. Achieving efficient mixing at such small scales presents unique challenges and opportunities. This review encompasses various techniques and strategies to evaluate and enhance mixing efficiency in these confined environments. It explores the significance of mixing in micro- and millichannels, highlighting its relevance for enhanced reaction kinetics, homogeneity in mixed fluids, and analytical accuracy. We discuss various mixing methodologies that have been employed to get a narrower residence time distribution. The role of channel geometry, flow conditions, and mixing mechanisms in influencing the mixing performance are also discussed. Various emerging technologies and advancements in microfluidic devices and tools specifically designed to enhance mixing efficiency are highlighted. We emphasize the potential applications of micro- and millichannels in fields of nanoparticle synthesis, which can be utilized for biological applications. Additionally, the prospects of machine learning and artificial intelligence are offered toward incorporating better mixing to achieve precise control over nanoparticle synthesis, ultimately enhancing the potential for applications in these miniature fluidic systems.

Biochemistry & Molecular Biology↗

Knowledge gaps for neuromorphic ionic computing

BACKGROUND Neuromorphic computing, inspired by the human brain’s ability to process information efficiently, represents a transformative approach to computation. In this Review, we explore the emerging field of neuromorphic ionic computing, which leverages ionic conduction and coupling to mimic neural processes, and identify critical knowledge gaps that must be addressed to realize its full potential. A central theme of the discussion is energy efficiency, a challenge that is both a limitation and an opportunity for this technology. Although complementary metal-oxide semiconductor (CMOS)–based neuromorphic technologies have made strides in scaling to billions of neurons and are increasingly applied in artificial intelligence and numerical computing, they remain orders of magnitude behind the human brain in terms of connectivity and energy efficiency. Neuromorphic ionic computing promises to overcome these limitations by leveraging the distinct architectural and operational principles of the brain. Our brains achieve this energy efficiency by combining several key features: using the same network elements to store and process information; using an incredibly complex and massively interconnected three-dimensional (3D) network of locally active elements that enables sparsity, robustness in the presence of noise, adaptation, and life-long learning; computing at comparatively low voltage and frequency; and last, taking advantage of a plethora of ions and small molecules as information carriers. Here, we propose that ionic computing systems can take advantage of similar features to achieve substantial gains in energy efficiency. ADVANCES Since the first reports of neuromorphic ionic behavior in nanofluidic channels, we have witnessed an explosion of reports that used ionic devices to produce synaptomimetic behaviors. However, achieving the goals of ionic computing requires not only implementation of much more sophisticated device functionality but also overcoming fundamental barriers in materials science, device architecture, and system integration. Current ionic devices, even those incorporating state-of-the-art materials, still suffer from limited functionality and stability, which restrict their performance and increase energy demands. Developing new materials with enhanced ionic properties is essential to overcome these limitations. Similarly, the design of neuromorphic devices must evolve to leverage the particular advantages of ionic processes. Existing architectures often follow a single-information-carrier logic of conventional electronics or are constructed of mesoscale fluidics, failing to capitalize on the energy-efficient mechanisms inherent to ionic systems or implement the multiple-information-carrier paradigm. Current neuromorphic chips focus on large-scale networks of analog memory elements based on mechanisms such as charge trap (flash), filamentary, phase change, or spin, which are built on top of a network of artificial CMOS neurons. Although such prototype networks have achieved impressive performance, it is difficult to envision how they can implement the key features such as massive connectivity, sophisticated plasticity, adaptability, sparsity, and “multichromatic” computing. Although small-scale devices have demonstrated promising results, integrating them, maintaining energy efficiency, and implementing temperature control as systems grow in complexity and size to computationally relevant scale remain major hurdles. Furthermore, interfacing neuromorphic ionic devices with existing computing technologies presents technical and conceptual challenges that will require innovative approaches that combine insights from neuroscience, materials science, and engineering. OUTLOOK Despite these challenges, the potential impact of neuromorphic ionic computing is profound with potential applications ranging from artificial intelligence to robotics and beyond. We also argue that neuromorphic ionic computing systems should not, at least in the beginning, compete with CMOS technologies but rather should focus on applications that require extreme energy efficiency with chemical and/or biological compatibility, such as biomedical applications (for example, brain-computer interfaces), environmental monitoring, and agricultural and food applications. Ultimately, this Review highlights the crucial role of interdisciplinary collaboration in advancing the field. Neuromorphic ionic computing is not merely a technological innovation; it represents a substantial step toward sustainable computation, aligning with the growing demand for energy-conscious solutions in a world that is increasingly reliant on data and computation.

Neuromorphic↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗

Development of in-situ polymerized intrinsically conductive resin and low-cost carbon pigments offering high conductivity for sensing, EMI shielding and lighting protection

Electrically conductive composites are emerging across diverse industries such as electronic, automotive, aerospace, advanced air mobility, biomedical, infrastructure, defense and security offering static charge dissipation, electromagnetic interference shielding, lighting protection, sensing, dicing, corrosion monitoring, etc. Conductivity enhanced composites provide several advantages compared to conventional metals including weight reduction, corrosion resistance, energy efficient processability, tunable properties and multifunctionality. Polymers are typically insulating in nature and require conducting filler for electron transport. However, dispersion and polymer-filler interphases are critical and often disrupt conducting pathways. Besides, conductive fillers such as graphene, carbon nanotube, MXene, silver nanowire, etc. are expensive, limiting their wide adoption in composite industry. On the other hand, a limited number of intrinsically conductive polymers are available among which polyaniline (PANI) has been widely studied due to its high conductivity, thermal and chemical stability. However, PANI is difficult to process and exhibits weak mechanical properties. In brief, there is a significant demand for electrically conductive polymer formulation with cost-effective conducting fillers that offer processability in scale to expand the market of conductivity enhanced materials.

Kumar, Vipin [Oak Ridge National Laboratory (ORNL)↗

Towards prevention and prediction of infectious diseases with virus sterilization using ultraviolet light and low-temperature plasma and bio-sensing devices for health and hygiene care

Inspired by the ideas of many authors, we provide insight on state-of-the-art potential technologies for the prevention and prediction of infectious diseases before they spread. This review also surveys virus sterilization with ultraviolet light and low temperature plasma technologies. Researchers in the various fields of medicine, materials, electronics, and plasma sciences have addressed increasingly challenging demands and the discussion encompasses the major challenges in societies that are faced with the threat of infectious diseases. In addition, technologies that use nanomaterials are evaluated for infection prevention and hygiene purposes. Advances in biomedical diagnostics for health care in terms of complementary metal-oxide-semiconductor transistors-based devices and telemetry for health monitoring are also reviewed.

60 APPLIED LIFE SCIENCES↗

Hierarchical Nanomaterials Assembled from Peptoids and Other Sequence-Defined Synthetic Polymers

In nature, the self-assembly of sequence-specific biopolymers into hierarchical structures plays an essential role in the construction of functional biomaterials. To develop synthetic materials that can mimic and surpass the function of these natural counterparts, various sequence-defined bio- and biomimetic polymers have been developed and exploited as building blocks for hierarchical self-assembly. This review summarizes the recent advances in the molecular self-assembly of hierarchical nanomaterials based on peptoids (or poly-N-substituted glycines) and other sequence-defined synthetic polymers. Modern techniques to monitor the assembly mechanisms and characterize the physicochemical properties of these self-assembly systems are highlighted. In addition, discussions about their potential applications in biomedical sciences and renewable energy are also included. Furthermore, this review aims to highlight essential features of sequence-defined synthetic polymers (e.g., high stability and protein-like high-information content) and how these unique features enable the construction of robust biomimetic functional materials with high programmability and predictability, with an emphasis on peptoids and their self-assembled nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SABRE-SHEATH hyperpolarized 15 N 2 -imidazole for Zn 2+ sensing

Zinc ions are essential for numerous biological functions and activities. Accordingly, Zn 2+ sensors are crucial in biomedical research to understand the role of Zn 2+ in health and disease. Here, we demonstrated the viability of SABRE-SHEATH hyperpolarized 15 N 2 -imidazole, providing an NMR signal enhancement of 45 700 fold (p = 2.15%), as a probe for Zn 2+ sensing by monitoring the Zn-imidazole interaction using NMR and extracted a LOD of 1.3 mM. This study is one of the first demonstrations of SABRE-SHEATH hyperpolarized 15 N as a sensor of other non-hyperpolarized species, which promises chemical sensing without penetration-depth limitations.

Hyperpolarization↗

In-situ Investigations on Gold Nanoparticles Stabilization Mechanisms in Biological Environments Containing HSA

Nanoparticles (NPs) developments advance innovative biomedical applications. However, complex interactions and the low colloidal stability of NPs in biological media restrict their widespread utilization. The influence of NPs properties on the colloidal stability for gold NPs with 5 and 40 nm in diameter with two surface modifications, methoxy-polyethylene glycol-sulfhydryl (PEG) and citrate, in NaCl and human serum albumin (HSA) protein solution, is investigated. This study is based on small-angle X-ray scattering (SAXS) methods allowing the in-situ monitoring of interactions in physiological conditions. The PEG coating provides high colloidal stability for NPs of both sizes. For 5 nm NPs in NaCl solution, a stable 3D self-assembled body-centered cubic (BCC) arrangement is detected with an interparticle distance of 20.7 ± 0.1 nm. In protein solution, this distance increases to 21.9 ± 0.1 nm by protein penetration inside the ordered structure. For citrate-capped NPs, a different mechanism is observed. The protein particles attach to the NPs surfaces, and an appropriate concentration of proteins results in a stable suspension. Cryogenic transmission electron microscopy (Cryo-TEM), UV–visible spectroscopy, and dynamic light scattering (DLS) support the SAXS results. The findings will pave the way to design and synthesize NPs with controlled behaviors in biomedical applications.

36 MATERIALS SCIENCE↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

SAXS studies of X-ray induced disulfide bond damage: Engineering high-resolution insight from a low-resolution technique

A significant problem in biological X-ray crystallography is the radiation chemistry caused by the incident X-ray beam. This produces both global and site-specific damage. Site specific damage can misdirect the biological interpretation of the structural models produced. Cryo-cooling crystals has been successful in mitigating damage but not eliminating it altogether; however, cryo-cooling can be difficult in some cases and has also been shown to limit functionally relevant protein conformations. The doses used for X-ray crystallography are typically in the kilo-gray to mega-gray range. While disulfide bonds are among the most significantly affected species in proteins in the crystalline state at both cryogenic and higher temperatures, there is limited information on their response to low X-ray doses in solution, the details of which might inform biomedical applications of X-rays. In this work we engineered a protein that dimerizes through a susceptible disulfide bond to relate the radiation damage processes seen in cryo-cooled crystals to those closer to physiologic conditions. This approach enables a low-resolution technique, small angle X-ray scattering (SAXS), to detect and monitor a residue specific process. A dose dependent fragmentation of the engineered protein was seen that can be explained by a dimer to monomer transition through disulfide bond cleavage. This supports the crystallographically derived mechanism and demonstrates that results obtained crystallographically can be usefully extrapolated to physiologic conditions. Fragmentation was influenced by pH and the conformation of the dimer, providing information on mechanism and pointing to future routes for investigation and potential mitigation. The novel engineered protein approach to generate a large-scale change through a site-specific interaction represents a promising tool for advancing radiation damage studies under solution conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Project 57 Air Monitoring Report: January 1 through December 31, 2019

On April 24, 1957, the Atomic Energy Commission (AEC) (now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley northeast of the Nevada National Security Site (NNSS) (formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was performed to (1) assess a technique for estimating plutonium distribution resulting from a nonnuclear detonation, (2) develop biomedical evaluation techniques for use in plutonium-laden environments, (3) evaluate methods of surface decontamination, and (4) evaluate instruments and field procedures for the prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and the DOE expanded the demarked Contamination Area (CA) in 2007 by posting signs 200 ft to 400 ft (60 m to 120 m) outside of the original fence.

54 ENVIRONMENTAL SCIENCES↗