Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bioelectricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of total body water estimates from O-18 and bioelectrical response prediction equations

Identification of an indirect, rapid means to measure total body water (TBW) during space flight may aid in quantifying hydration status and assist in countermeasure development. Bioelectrical response testing and hydrostatic weighing were performed on 27 subjects who ingested O-18, a naturally occurring isotope of oxygen, to measure true TBW. TBW estimates from three bioelectrical response prediction equations and fat-free mass (FFM) were compared to TBW measured from O-18. A repeated measures MANOVA with post-hoc Dunnett's Test indicated a significant (p less than 0.05) difference between TBW estimates from two of the three bioelectrical response prediction equations and O-18. TBW estimates from FFM and the Kushner & Schoeller (1986) equation yielded results that were similar to those given by O-18. Strong correlations existed between each prediction method and O-18; however, standard errors, identified through regression analyses, were higher for the bioelectrical response prediction equations compared to those derived from FFM. These findings suggest (1) the Kushner & Schoeller (1986) equation may provide a valid measure of TBW, (2) other TBW prediction equations need to be identified that have variability similar to that of FFM, and (3) bioelectrical estimates of TBW may prove valuable in quantifying hydration status during space flight.

Barrows, Linda H.↗

Bioelectric Control of a 757 Class High Fidelity Aircraft Simulation

This paper presents results of a recent experiment in fine grain Electromyographic (EMG) signal recognition, We demonstrate bioelectric flight control of 757 class simulation aircraft landing at San Francisco International Airport. The physical instrumentality of a pilot control stick is not used. A pilot closes a fist in empty air and performs control movements which are captured by a dry electrode array on the arm, analyzed and routed through a flight director permitting full pilot outer loop control of the simulation. A Vision Dome immersive display is used to create a VR world for the aircraft body mechanics and flight changes to pilot movements. Inner loop surfaces and differential aircraft thrust is controlled using a hybrid neural network architecture that combines a damage adaptive controller (Jorgensen 1998, Totah 1998) with a propulsion only based control system (Bull & Kaneshige 1997). Thus the 757 aircraft is not only being flown bioelectrically at the pilot level but also demonstrates damage adaptive neural network control permitting adaptation to severe changes in the physical flight characteristics of the aircraft at the inner loop level. To compensate for accident scenarios, the aircraft uses remaining control surface authority and differential thrust from the engines. To the best of our knowledge this is the first time real time bioelectric fine-grained control, differential thrust based control, and neural network damage adaptive control have been integrated into a single flight demonstration. The paper describes the EMG pattern recognition system and the bioelectric pattern recognition methodology.

Jorgensen, Charles↗

Bioelectric activity of skeletal muscle under conditions of alternating action of g-Forces and weightlessness

The bioelectric activity of the musculature of animals and man was studied during alternating g-forces and weightlessness. The appropriate conditions were reproduced in flight along a parabolic curve; in this case, weightlessness lasting 25-30 sec alternated with g-forces of about 2 g magnitude. Quite regular changes in the bioelectric activity of various groups of muscles were disclosed under g-forces and in weightlessness. Thus, muscle biopotential amplitudes of 130-180 microvolt in horizontal flight, increased to 190-330 microvolt under g-forces. In the subsequent weightlessness, an abrupt reduction in oscillation voltage was observed and, in a number of cases, phenomena, similar to the picture of bioelectric silence were noted.

Yuganov, Y. M.↗

An equivalent body surface charge model representing three-dimensional bioelectrical activity

A new surface-source model has been developed to account for the bioelectrical potential on the body surface. A single-layer surface-charge model on the body surface has been developed to equivalently represent bioelectrical sources inside the body. The boundary conditions on the body surface are discussed in relation to the surface-charge in a half-space conductive medium. The equivalent body surface-charge is shown to be proportional to the normal component of the electric field on the body surface just outside the body. The spatial resolution of the equivalent surface-charge distribution appears intermediate between those of the body surface potential distribution and the body surface Laplacian distribution. An analytic relationship between the equivalent surface-charge and the surface Laplacian of the potential was found for a half-space conductive medium. The effects of finite spatial sampling and noise on the reconstruction of the equivalent surface-charge were evaluated by computer simulations. It was found through computer simulations that the reconstruction of the equivalent body surface-charge from the body surface Laplacian distribution is very stable against noise and finite spatial sampling. The present results suggest that the equivalent body surface-charge model may provide an additional insight to our understanding of bioelectric phenomena.

NASA Discipline Regulatory Physiology↗

Characterization of bioelectric potentials

Method and system for recognizing and characterizing bioelectric potential or electromyographic (EMG) signals associated with at least one of a coarse gesture and a fine gesture that is performed by a person, and use of the bioelectric potentials to enter data and/or commands into an electrical and/or mechanical instrument. As a gesture is performed, bioelectric signals that accompany the gesture are subjected to statistical averaging, within selected time intervals. Hidden Markov model analysis is applied to identify hidden, gesture-related states that are present. A metric is used to compare signals produced by a volitional gesture (not yet identified) with corresponding signals associated with each of a set of reference gestures, and the reference gesture that is closest to the volitional gesture is identified. Signals representing the volitional gesture are analyzed and compared with a database of reference gestures to determine if the volitional gesture is likely to be one of the reference gestures. Electronic and/or mechanical commands needed to carry out the gesture may be implemented at an interface to control an instrument. Applications include control of an aircraft, entry of data from a keyboard or other data entry device, and entry of data and commands in extreme environments that interfere with accurate entry.

Jorgensen, Charles C.↗

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

Noninvasive estimation of fluid shifts between body compartments by measurement of bioelectric characteristics

Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.

Bishop, Phillip A.↗

Comparative life cycle assessment of woody biomass processing: air classification, drying, and size reduction powered by bioelectricity versus grid electricity

Sulfur accumulation during biofuel production is pollutive and toxic to conversion catalysts and causes the premature breakdown of processing equipment. Air classification is an effective preprocessing technology for ash and sulfur reduction from biomass feedstocks. Here, a life cycle assessment (LCA) sought to understand the environmental impact of implementing air classification as a sulfur-mitigation technique to improve feedstock quality for pine residues using a grid electricity scenario (GES) versus a bioelectricity scenario (BES). Global warming potential (GWP) for preprocessing was simulated using inventory databases embedded in SimaPro and the Argonne National Laboratory’s GREET model, specifically focusing on comparing the GWP of a GES versus a BES. Overall, the GES had a GWP impact over seven times that of the BES (136 versus 18 kg CO 2 equivalent per tonne of usable feedstock), with steam generation during rotary drying accounting for 57% of the GES’s GWP. Air classification represents 0.4% and 1.6% of the total GWP impact for the GES and BES, respectively. Therefore, air classification can facilitate a 30% reduction in feedstock sulfur content to improve feedstock quality for biofuel conversion and lessen corrosion of equipment while contributing minimal GWP impact during preprocessing.

Air classification↗

A hybrid cyt c maturation system enhances the bioelectrical performance of engineered Escherichia coli by improving the rate-limiting step

Bioelectronic devices can use electron flux to enable communication between biotic components and abiotic electrodes. We have modified Escherichia coli to electrically interact with electrodes by expressing the cytochrome c from Shewanella oneidensis MR-1. However, we observe inefficient electrical performance, which we hypothesize is due to the limited compatibility of the E. coli cytochrome c maturation (Ccm) systems with MR-1 cytochrome c. Here we test whether the bioelectronic performance of E. coli can be improved by constructing hybrid Ccm systems containing protein domains from both E. coli and S. oneidensis MR-1. The hybrid CcmH increased cytochrome c expression by increasing the abundance of CymA 60%, while only slightly changing the abundance of the other cytochromes c. Electrochemical measurements showed that the overall current from the hybrid ccm strain increased 121% relative to the wildtype ccm strain, with an electron flux per cell of 12.3 ± 0.3 fA·cell -1 . Additionally, the hybrid ccm strain doubled its electrical response with the addition of exogenous flavin, and quantitative analysis of this demonstrates CymA is the rate-limiting step in this electron conduit. These results demonstrate that this hybrid Ccm system can enhance the bioelectrical performance of the cyt c expressing E. coli, allowing the construction of more efficient bioelectronic devices.

59 BASIC BIOLOGICAL SCIENCES↗

Dual-Color Optical Recording of Bioelectric Potentials by Polymer Electrochromism

Optical recording based on voltage-sensitive fluorescent reporters allows for spatial flexibility of measuring from desired cells, but photobleaching and phototoxicity of the fluorescent labels often limit their sensitivity and recording duration. Voltage-dependent optical absorption, rather than fluorescence, of electrochromic materials, would overcome these limitations to achieve long-term optical recording of bioelectrical signals. Electrochromic materials such as PEDOT:PSS possess the property that an applied voltage can either increase or decrease the light absorption depending on the wavelength. In this work, we harness this anticorrelated light absorption at two different wavelengths to significantly improve the signal detection. With dual-color detection, electrical activity from cells produces signals of opposite polarity, while artifacts, mechanical motions, and technical noises are uncorrelated or positively correlated. Using this technique, we are able to optically record cardiac action potentials with a high signal-to-noise ratio, 10 kHz sampling rate, >15 min recording duration, and no time-dependent degradation of the signal. Furthermore, we can reliably perform multiple recording sessions from the same culture for over 25 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗