Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beacon tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

60 APPLIED LIFE SCIENCES↗

An Educational Program on Concentrated Solar Power and Heliostats for Power Generation and Industrial Processes

The objective of this project was to design and implement a comprehensive educational and applied research program in Concentrated Solar Thermal Power (CSTP) and heliostat technologies at Northeastern University. In alignment with the U.S. Department of Energy's Heliostat Consortium (HelioCon) goals, the project aimed to expand student and public understanding of CSTP systems while simultaneously contributing to workforce development and the broader decarbonization strategy. A particular emphasis was placed on integrating hands-on student design projects and publicly disseminating educational content relevant to CSTP systems. The project addressed a critical gap in renewable energy education: CSTP and heliostats, despite their importance in utility-scale solar energy, are rarely included in standard mechanical engineering programs. This project established new pathways for students to engage with the topic through the creation of a 4-credit graduate/senior elective course, development of five industry-facing short courses, and the inclusion of CSTP-based capstone design projects. Over two academic years, 36 students across six senior design teams developed and tested technologies such as deformable heliostats, beacon-based tracking systems, and solar-powered pyrolizers for biomass-to-biochar conversion. Concurrently, 30 undergraduate and graduate students were enrolled in the new academic course centered around CSTP principles. To ensure the relevance and accessibility of the short course content, the project team engaged with industry professionals, technical policy stakeholders, and potential course participants through structured surveys and informal consultations. Feedback from 28 respondents guided the structure, length, and delivery format of the courses - resulting in a modular design broken into five workshops. The feedback emphasized the need for flexible, asynchronous delivery and practical case studies, particularly in areas such as heliostat control, thermal storage, and solar fuel production. This engagement helped align the courses with the evolving knowledge demands of the renewable energy workforce and ensured that participants from both technical and policy backgrounds could meaningfully benefit from the material. The research and educational activities advanced the understanding of heliostat control systems, optical performance under misalignment, and thermal system integration in solar-driven pyrolysis applications. Methods and designs explored in this project proved to be both technically effective and economically feasible at the lab scale. Prototypes were constructed using commercially available components and custom-fabricated elements, demonstrating that meaningful performance improvements can be achieved with modest material and fabrication costs, supporting the feasibility of student-led research in this field. The public benefit of this project is twofold. First, it cultivates a pipeline of engineers trained to be familiar with CSTP principles, an essential workforce need identified by the Department of Energy for achieving its 2030 cost and deployment targets. Second, it contributes openly accessible educational materials, course content, and experimental frameworks to the broader community, enabling other institutions to adopt or adapt similar programming. Through outreach activities, curriculum integration, and technical exposure, this project contributes to a more informed and capable renewable energy workforce while supporting innovation in heliostat and CSTP system design. A new technical report is being prepared to document the development of the course and its outcomes, with plans to publish it in the ASME Open Access Journal of Engineering to ensure global accessibility, free of cost.

14 SOLAR ENERGY↗

MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

SU-F-J-142: Proposed Method to Broaden Inclusion Potential of Patients Able to Use the Calypso Tracking System in Prostate Radiotherapy

Purpose: To introduce a non-standard method of patient setup, using BellyBoard immobilization, to better utilize the localization and tracking potential of an RF-beacon system with EBRT for prostate cancer. Methods: An RF-beacon phantom was imaged using a wide bore CT scanner, both in a standard level position and with a known rotation (4° pitch and 7.5° yaw). A commercial treatment planning system (TPS) was used to determine positional coordinates of each beacon, and the centroid of the three beacons for both setups. For each setup at the Linac, kV AP and Rt Lateral images were obtained. A full characterization of the RF-beacon system in clinical mode was completed for various beacons’ array-to-centroid distances, which includes vertical, lateral, and longitudinal offset data, as well as pitch and yaw offset measurements for the tilted phantom. For the single patient who has been setup using the proposed BellyBoard method, a supine simulation was first obtained. When abdominal protrusion was found to be exceeding the limits of the RF-Beacon system through distance-based analysis in the TPS, the patient is re-simulated prone with the BellyBoard. Array to centroid distance is measured again in the TPS, and if found to be within the localization or tracking region it is applied. Results: Characterization of limitations for the RF-beacon system in clinical mode showed acceptable consistency of offset determination for phantom setup accuracy. The nonstandard patient setup method reduced the beacons’ centroid-to-array distance by 8.32cm, from 25.13cm to 16.81cm; completely out of tracking range (greater than 20cm) to within setup tracking range (less than 20cm). Conclusion: Using the RF-beacon system in combination with this novel patient setup can allow patients who would otherwise not be candidates for beacon enhanced EBRT to now be able to benefit from the reduced PTV margins of this treatment method.

60 APPLIED LIFE SCIENCES↗

Real-Time Tumor Tracking in the Lung Using an Electromagnetic Tracking System

Purpose: To describe the first use of the commercially available Calypso 4D Localization System in the lung. Methods and Materials: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R{sup 2}) were tabulated for all 42 tracks. Results: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Conclusions: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-32: Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold

Purpose: Our institution uses a manual laser-based system for primary localization and verification during radiation treatment of left-sided breast cancer patients using deep inspiration breath hold (DIBH). This primary system was compared with sternum-placed Calypso(R) beacons (Varian Medical Systems, CA). Only intact breast patients are considered for this analysis. Methods: During computed tomography (CT) simulation, patients have BB and Calypso(R) surface beacons positioned sternally and marked for free-breathing and DIBH CTs. During dosimetry planning, BB longitudinal displacement between free breathing and DIBH CT determines laser mark (BH mark) location. Calypso(R) beacon locations from the DIBH CT are entered at the Tracking Station. During Linac simulation and treatment, patients inhale until the cross-hair and/or lasers coincide with the BH Mark, which can be seen using our high quality cameras (Pelco, CA). Daily Calypso(R) displacement values (difference from the DIBH-CT-based plan) are recorded.The displacement mean and standard deviation was calculated for each patient (77 patients, 1845 sessions). An aggregate mean and standard deviation was calculated weighted by the number of patient fractions.Some patients were shifted based on MV ports. A second data set was calculated with Calypso(R) values corrected by these shifts. Results: Mean displacement values indicate agreement within 1±3mm, with improvement for shifted data (Table). Conclusion: Both unshifted and shifted data sets show the Calypso(R) system coincides with the laser system within 1±3mm, demonstrating either localization/verification system will Resultin similar clinical outcomes. Displacement value uncertainty unilaterally reduces when shifts are taken into account.

07 ISOTOPE AND RADIATION SOURCES↗

Polarization tracking system for free-space optical communication, including quantum communication

Quantum communication transmitters include beacon lasers that transmit a beacon optical signal in a predetermined state of polarization such as one of the states of polarization of a quantum communication basis. Changes in the beacon polarization are detected at a receiver, and a retarder is adjusted so that the states of polarization in a received quantum communication optical signal are matched to basis polarizations. The beacon and QC signals can be at different wavelengths so that the beacon does not interfere with detection and decoding of the QC optical signal.

42 ENGINEERING↗

SU-F-J-27: Segmentation of Prostate CBCT Images with Implanted Calypso Transponders Using Double Haar Wavelet Transform

Purpose: Segmentation of prostate CBCT images is an essential step towards real-time adaptive radiotherapy. It is challenging For Calypso patients, as more artifacts are generated by the beacon transponders. We herein propose a novel wavelet-based segmentation algorithm for rectum, bladder, and prostate of CBCT images with implanted Calypso transponders. Methods: Five hypofractionated prostate patients with daily CBCT were studied. Each patient had 3 Calypso transponder beacons implanted, and the patients were setup and treated with Calypso tracking system. Two sets of CBCT images from each patient were studied. The structures (i.e. rectum, bladder, and prostate) were contoured by a trained expert, and these served as ground truth. For a given CBCT, the moving window-based Double Haar transformation is applied first to obtain the wavelet coefficients. Based on a user defined point in the object of interest, a cluster algorithm based adaptive thresholding is applied to the low frequency components of the wavelet coefficients, and a Lee filter theory based adaptive thresholding is applied to the high frequency components. For the next step, the wavelet reconstruction is applied to the thresholded wavelet coefficients. A binary/segmented image of the object of interest is therefore obtained. DICE, sensitivity, inclusiveness and ΔV were used to evaluate the segmentation result. Results: Considering all patients, the bladder has the DICE, sensitivity, inclusiveness, and ΔV ranges of [0.81–0.95], [0.76–0.99], [0.83–0.94], [0.02–0.21]. For prostate, the ranges are [0.77–0.93], [0.84–0.97], [0.68–0.92], [0.1–0.46]. For rectum, the ranges are [0.72–0.93], [0.57–0.99], [0.73–0.98], [0.03–0.42]. Conclusion: The proposed algorithm appeared effective segmenting prostate CBCT images with the present of the Calypso artifacts. However, it is not robust in two scenarios: 1) rectum with significant amount of gas; 2) prostate with very low contrast. Model based algorithm might improve the segmentation in these two scenarios.

60 APPLIED LIFE SCIENCES↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-183: Quantification of Motion During Hypo-Fractionated Prostate Cancer Radiation Therapy

Purpose: To quantify patient motion during hypo-fractionated prostate cancer treatment as tracked by Calypso™ 4D localization system. Methods: 50 prostate cancer patients with implanted Calypso beacons underwent hypofractionated IMRT treatment. Typical fraction size was 5 with doses of 5–8 Gy/fraction. 213 traces from the 50 patients were analyzed to quantify the probability of motion vs time starting from beam-on. Couch corrections applied by therapists were undone to obtain the natural course of patient motion. The Calypso data was used to identify vector displacements greater than 2 mm from the starting position. The direction of this vector was classified into one of the 26 directions (combinations of L/R, A/P, S/I). The probability of motion >2mm was estimated by computing the fraction of traces that exceed the 2mm threshold at each time point. The violating motion points were also binned by direction in order to identify specific directions that were more prone to movement. Results: The overall probability of motion greater than 2 mm at 5 and 10 minutes from beam-on were 27 % and 50% respectively. The primary directions in which motion occurred were Posterior-Inferior (PI) and Inferior (I) with a probability of 8.5% and 4% at 5 minutes and 10% for both at 10 minutes. Motion was classified into the following bins: 0–2, 2–3, 3–4, 4–5, 5–6, 6–7, 7–8 and greater than 8 mm. It is observed that motion < 2mm decreases from the first 5 minutes to the next while the higher magnitude components increase with time. Conclusion: The probability of prostate motion increases with time. The trend seen in the PI and I directions can be attributed to physiological factors like bladder filling. This probability can be factored in for scheduling intrafraction imaging and used to compare dosimetric impact of VMAT vs. IMRT plans. This work is supported in part by Varian Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-574: Fessiblity of Using the Calypso System for HDR Interstitial Catheter Reconstruction

Purpose: It is always a challenge to reconstruct the interstitial catheter for high dose rate (HDR) brachytherapy on patient CT or MR images. This work aims to investigate the feasibility of using the Calypso system (Varian Medical, CA) for HDR catheter reconstruction utilizing its accuracy on tracking the electromagnetic transponder location. Methods: Experiment was done with a phantom that has a HDR interstitial catheter embedded inside. CT scan with a slice thickness of 1.25 mm was taken for this phantom with two Calypso beacon transponders in the catheter. The two transponders were connected with a wire. The Calypso system was used to record the beacon transponders’ location in real time when they were gently pulled out with the wire. The initial locations of the beacon transponders were used for registration with the CT image and the detected transponder locations were used for the catheter path reconstruction. The reconstructed catheter path was validated on the CT image. Results: The HDR interstitial catheter was successfully reconstructed based on the transponders’ coordinates recorded by the Calypso system in real time when the transponders were pulled in the catheter. After registration with the CT image, the shape and location of the reconstructed catheter are evaluated against the CT image and the result shows an accuracy of 2 mm anywhere in the Calypso detectable region which is within a 10 cm X 10 cm X 10 cm cubic box for the current system. Conclusion: It is feasible to use the Calypso system for HDR interstitial catheter reconstruction. The obstacle for its clinical usage is the size of the beacon transponder whose diameter is bigger than most of the interstitial catheters used in clinic. Developing smaller transponders and supporting software and hardware for this application is necessary before it can be adopted for clinical use.

60 APPLIED LIFE SCIENCES↗

LabVIEW Task Manager v. 1.10.0

LabVIEW Task Manager is a debugging tool for use during code development in the National Instruments (NI) LabVIEW® IDE. While providing a dynamic & big-picture view of running code, an expandable/collapsible tree diagram displays detailed information (both static and dynamic) on all VIs in memory, belonging to a selected project/target. It allows for interacting with single or multiple selected VIs at a time, providing significant benefits while troubleshooting, and has the following features: Look & Feel similar to Windows® Task Manager; Selection of project/target; Lists all VIs in memory, grouped by class/library; Searches for and enumerates clones in memory; DropIn VI for including dynamically referenced clones (Clone Beacon); 'Refresh Now' (F5) re-reads all VIs in memory and adds new ones to the tree; Displays VI name, owning class/library, state, path, data size & code size; Displays VI FP Behavior, Reentrant?, Reentrancy Type, Paused? & Highlight?; Sort by any column, including by library name; Filter by item types vi, ctl, and vit/ctt; Filter out vi.lib and global VIs; Tracking of, and ability to toggle, execution highlighting on multiple selected VIs; Tracking of paused VIs with ability to Pause/Resume/TogglePause multiple selected VIs; DropIn VI for pausing on a condition; If a clone initiates a pause, a different pause symbol is used for all clones of that same reentrant original VI; Select multiple VIs and open or close their FPs or BDs; Double Click a VI from the tree to bring the BD (first choice) or FP to front, if already open; and Select multiple top-level VIs and Abort them.

Vargo, TimothyD.↗

Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system

Purpose: The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. Methods: They equipped a research Siemens Artiste linear accelerator (linac) with a 41 x 41 cm{sup 2} a-Si flat-panel detector underneath the treatment head. The in-line geometry allows kV (imaging) and MV (treatment) beams to share closely aligned beam axes. The kV source, usually mounted directly across from the flat-panel imager, was retracted toward the gantry by 13 cm to intentionally misalign kV and MV beams, resulting in a geometric separation of MV treatment field and kV image on the detector. Two consecutive images acquired within 140 ms (the first with MV-only and the second with kV and MV signal) were subtracted to generate a kV-only image. The images were then analyzed ''online'' with an automated threshold-based marker detection algorithm. They employed a 3D and a 4D phantom equipped with either a single radioopaque marker or three Calypso beacons to mimic respiratory motion. Measured room positions were either cross-referenced with a phantom voltage signal (single marker) or the Calypso system. The accuracy of the back-projection (from detected marker positions into room coordinates) was verified by a simulation study. Results: A phantom study has demonstrated that the imaging framework is capable of automatically detecting marker positions and sending this information to the tracking tool at an update rate of 7.14 Hz. The system latency is 86.9 {+-} 1.0 ms for single marker detection in the absence of MV radiation. In the presence of a circular MV field of 5 cm diameter, the latency is 87.1 {+-} 0.9 ms. The total RMS position detection accuracy is 0.20 mm (without MV radiation) and 0.23 mm (with MV). Conclusions: Based on the evaluated motion patterns and MV field size, the positional accuracy and system latency indicate that this system is suitable for real-time adaptive applications.

60 APPLIED LIFE SCIENCES↗

Molecular Aspects of Transport in Thin Films of Controlled Architecture

Our laboratory focuses on developing spatially localized chemistries which can produce structures of controlled architecture on the supermolecular length scale -- structures which allow us to control the motion of molecular species with high spatial resolution, ultimately on nanometer length scales. Specifically, nanocapillary array membranes (NCAMs) contain an array of nanometer diameter pores connecting vertically separated microfluidic channels. NCAMs can manipulate samples with sub-femtoliter characteristic volumes and attomole sample amounts and are opening the field of chemical analysis of mass-limited samples, because they are capable of digital control of fluid switching down to sub-attoliter volumes; extension of analytical “unit operations” down to sub-femtomole sample sizes; and exerting spatiotemporal control over fluid mixing to enable studies of reaction dynamics. Digital flow switching mediated by nanocapillary array membranes can be controlled by bias, ionic strength, or pore diameter and is being studied by observing the temporal characteristics of transport across a single nanopore in thin PMMA membranes. The control of flow via nanopore surface characteristics, charge density and functional group presentation, is being studied by coupled conductivity and laser-induced fluorescence (LIF) measurements. Reactive mixing experiments previously established low millisecond mixing times for NCAM-mediated fluid transfer, and this has been exploited to demonstrate capture of mass-limited target species by Au colloids. Voltage and thermally-activated polymer switches have been developed for active control of transport in NCAMs. Thermally-switchable and size-selective transport was achieved by grafting poly(N-isopropylacrylamide) brushes onto the exterior surface of a Au-coated polycarbonate track-etched membrane, while the voltage-gated properties of poly(hydroxyethylmethacrylate) were characterized dynamically. Electrophoretic separations have been coupled to analyte sampling both by LIF and mass spectrometry. Detection of electrophoresis separation products by electrospray mass spectrometry was achieved through direct interfacing to an electrospray mass spectrometer. Pb(II) interactions with the DNAzyme have been realized in an NCAM-coupled integrated microfluidic structure allowing cation separations to be coupled to molecular beacon detection motifs for the determination of Pb(II) in an electroplating sludge reference material. By changing the DNAzyme to select for other compounds of interest, it is possible to incorporate multiple sensing systems within a single device, thereby achieving great flexibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-FG-BRA-02: A Feasibility Study of Integrating Breathing Audio Signal with Surface Surrogates for Respiratory Motion Management

Purpose: Tracking the surrogate placed on patient skin surface sometimes leads to problematic signals for certain patients, such as shallow breathers. This in turn impairs the 4D CT image quality and dosimetric accuracy. In this pilot study, we explored the feasibility of monitoring human breathing motion by integrating breathing sound signal with surface surrogates. Methods: The breathing sound signals were acquired though a microphone attached adjacently to volunteer’s nostrils, and breathing curve were analyzed using a low pass filter. Simultaneously, the Real-time Position Management™ (RPM) system from Varian were employed on a volunteer to monitor respiratory motion including both shallow and deep breath modes. The similar experiment was performed by using Calypso system, and three beacons taped on volunteer abdominal region to capture breath motion. The period of each breathing curves were calculated with autocorrelation functions. The coherence and consistency between breathing signals using different acquisition methods were examined. Results: Clear breathing patterns were revealed by the sound signal which was coherent with the signal obtained from both the RPM system and Calypso system. For shallow breathing, the periods of breathing cycle were 3.00±0.19 sec (sound) and 3.00±0.21 sec (RPM); For deep breathing, the periods were 3.49± 0.11 sec (sound) and 3.49±0.12 sec (RPM). Compared with 4.54±0.66 sec period recorded by the calypso system, the sound measured 4.64±0.54 sec. The additional signal from sound could be supplement to the surface monitoring, and provide new parameters to model the hysteresis lung motion. Conclusion: Our preliminary study shows that the breathing sound signal can provide a comparable way as the RPM system to evaluate the respiratory motion. It’s instantaneous and robust characteristics facilitate it possibly to be a either independently or as auxiliary methods to manage respiratory motion in radiotherapy.

60 APPLIED LIFE SCIENCES↗