Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “basement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Precambrian Crystalline Basement Properties From Pressure History Matching and Implications for Induced Seismicity in the US Midcontinent

Injection-induced seismicity across the US midcontinent has almost exclusively occurred in the crystalline basement that underlies the Arbuckle Group aquifer and its equivalents, the primary wastewater disposal zone in this region. However, the properties of the basement are not well known. Newly compiled data, from Class I wells in Kansas, provide a unique record of pressures in the Arbuckle and an opportunity to constrain the reservoir-scale properties of the basement such as permeability, diffusivity, and specific storage. Constraints on these parameters are critical for modeling fluid flow and pressures across the entire Arbuckle-basement system, and are necessary for accurate evaluation and prediction of injection-induced earthquakes. Here, we present a detailed, three-dimensional geological and pressure history-matched numerical model for the Arbuckle and basement, based on data from >400 wells covering a large region in south-central Kansas, where injection-induced seismicity has been concentrated since 2014. Simulations of dynamic data from 319 wells indicate that Arbuckle pressures have increased by 1.1 MPa in high injection rate areas and an overpressure of <0.1 MPa may be the cause of seismicity in the basement. Pressure-history matching also yields the likely range in porosity (0.3%–7%), permeability (0.1–0.7 mD), and diffusivity (0.004–0.07 m2 /s) for the basement. The resulting estimates suggest reservoir-scale properties of the basement are enhanced by faults and fractures. Importantly, the diffusivities determined in this study are lower than estimates derived from Kansas earthquake triggering fronts, and suggest that such seismicity-based techniques may have limitations, particularly where spacetime patterns between injection and seismicity are complex.

58 GEOSCIENCES↗

Hydrologic windows into the crystalline basement and their controls on groundwater flow patterns across the Paradox Basin, western USA

Conceptual models of sedimentary basin groundwater flow systems typically assume that the crystalline basement acts as an impermeable boundary and can be neglected. In this study, we use hydrologic models constrained by isotopic and geochemical datasets to argue that the La Sal Mountains, Utah, USA, act as a hydrologic window into the Paradox Basin’s lower aquifer system and underlying crystalline basement. We conducted a sensitivity study in which we varied crystalline basement/laccolith permeability as well as fault zone connectivity along a cross-sectional transect from the La Sal Mountains to Lisbon Valley. When the crystalline basement/laccolith units are set at relatively permeable levels (10–14 m 2 ), simulated tracers that include total dissolved solids, oxygen isotopic composition of pore fluids (δ 18 O), and groundwater residence times are in closest agreement with field measurements. Model results indicate that pore fluids in the basal aquifer system underlying the Paradox Formation confining unit are a mixture of relatively young meteoric fluids and older Paradox Formation brines. The presence of faults did not significantly modify fluid exchange between the upper and lower aquifer systems. This was due, in part, to underpressuring within the Paradox Formation. Our study concludes that the Paradox Basin represents a regional recharge area for the Colorado Plateau, with groundwater discharge occurring along the Colorado River within the Grand Canyon some 375 km away to the southwest. This is only possible with a permeable crystalline basement. Our findings help explain the genesis of Mississippi Valley-type ore deposits of the US Midcontinent, where the presence of a permeable basement may be useful in addressing issues related to solute mass and energy balance.

54 ENVIRONMENTAL SCIENCES↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potential Seismicity Along Basement Faults Induced by Geological Carbon Sequestration

Large-scale CO 2 sequestration into geological formations has been suggested to reduce CO 2 emissions from industrial activities. However, much like enhanced geothermal stimulation and wastewater injection, CO 2 sequestration has a potential to induce earthquake along weak faults, which can be considered a negative impact on safety and public opinion. This research shows the physical mechanisms of potential seismic hazards along basement faults driven by CO 2 sequestration under variation in geological and operational constraints. Specifically we compare the poroelastic behaviors between multiphase flow and single-phase flow cases, highlighting specific needs of evaluating induced seismicity associated with CO 2 sequestration. In contrast to single-phase injection scenario, slower migration of the CO 2 plume than pressure pulse may delay accumulation of pressure and stress along basement faults that may not be mitigated immediately by shut-in of injection. The impact of multiphase flow system, therefore, needs to be considered for proper monitoring and mitigation strategies.

58 GEOSCIENCES↗

Hydromechanical impact of basement rock on injection-induced seismicity in Illinois Basin

Abstract The common explanation of observed injection-induced microseismicity is based on the measured stress state at the injection interval and the assumption that it remains the same in the vicinity. We argue here that representing the stress state in different geologic formations over the injection site with the single Mohr’s circle is insufficient due to local stratigraphic features and contrast in compressibilities of the involved formations. The role of hydromechanical coupling in the microseismic response is also crucial for the proper assessment of the problem. Thoroughly monitored Illinois Basin Decatur Project revealed the majority of CO 2 injection-associated microseismic events being originated in the crystalline basement. Even though basement faults can serve as the conduits for fluid flow—the predicted pressure increase seems to be insufficient to trigger seismicity. To address this issue, accurate laboratory measurements of rock properties from the involved formations are conducted. The pre-injection stress state and its evolution are evaluated with the hydromechanically coupled numerical model. It appears that the presence of an offset in a stiff competent layer affects the stress state in its vicinity. Therefore, both the pre-injection stress state and its evolution during the fluid injection should be addressed during the induced seismicity assessment.

54 ENVIRONMENTAL SCIENCES↗

Radon Kinetics in a Basement Space Measured with Different Devices

Although indoor monitoring of radon and benchmarking of radon measurement devices remain important research topics, few intercomparisons of active radon measurement devices have been performed under realistic conditions, let alone dynamic ones enabling comparison of their transient behavior. Five different radon monitors were therefore placed in a poorly ventilated basement space under three different conditions: 24 h under a steady, elevated radon level, 24 h with fans turned on to produce a radon washout transient, and 9 d with fans turned off for a radon buildup transient. Resulting radon concentrations varied between ~200 and ~2,000 Bq m -3 . Accuracy of the devices were evaluated using root-mean-square error, and ventilation data were fit to first order linear compartmental models. To more accurately model behaviors such as cyclic diurnal variations, the source term corresponding to entry of radon from soil into the basement was considered to be non-constant, as it is likely to vary drastically with both the indoor-outdoor pressure differential and soil concentration variations. Here, the improved radon washout model fit very well with the measurements. Despite a wide variety in list prices, all devices performed similarly during transients and at different radon concentrations.

60 APPLIED LIFE SCIENCES↗

MRCI Subtask 2.2: Precambrian Basement Structure, Faulting, and Stress Final Technical Summary Report

Subtask 2.2 was largely focused on compiling information about the Precambrian basement rock that underlies the MRCI region. Understanding the nature and extent of the basement rock is important in order to mitigate certain risks associated with CO2 injection. For example, this information will provide a resource for defining areas where a storage reservoir is in direct contact with the Precambrian or indirectly via a fault. Also, an understanding of the stress field in addition to fault orientations will help determine which faults may be subject to reactivation under increased pore pressures.

Battelle,CCS,CCUS,Carbon storage,MRCI,Midwest Regi↗

Mitigating Injection‐Induced Seismicity Along Basement Faults by Extraction: Application to 2016–2018 Pohang Earthquakes

Abstract The risk of induced earthquake is considered as the major obstacle for sustainable subsurface energy activities. As a mitigation approach, mechanistic risk assessment can be essential to minimize the potential of seismic hazard. Coupled hydro‐mechanical modeling approach is integrated with geomechanical analysis to better assess the occurrence of seismicity induced by injection and/or extraction, which will provide a basis to update operational conditions (e.g., number and location of mitigating wells, rate and duration of operations) for mitigating earthquake nucleation. The Coulomb stability analysis and seismicity rate estimates from this generic study indicate that simultaneous extraction can relieve injection‐induced pore‐pressure buildup, but also transfer and accumulate elastic energy along the faults. Field‐scale simulation with variation in well design for the Pohang EGS site, South Korea, show that multiple wells aligned across a preexisting fault form gradients of pressure and stress fields normal to the fault, which can enhance the direct impact of diffusion process and poroelastic stressing on the fault stability perturbation. Our mechanistic study suggests multiphysics‐oriented mitigation strategies that consider (1) possible mechanical deformation, caused by hydro‐mechanical coupling effects, and (2) proper configuration of well operations based on site‐specific geological characteristics.

Chang, K. W.↗

Basement Fault Activation before Larger Earthquakes in Oklahoma and Kansas

Oklahoma and Kansas experienced unprecedented seismic activity over the past decade due to earthquakes associated with unconventional hydrocarbon development. The modest natural seismicity and incomplete knowledge of the fault network in the region made it difficult to anticipate the locations of earthquakes with larger magnitudes (M w ≥ 4). Here, we show that monitoring of microearthquakes at regional scale using a pretrained neural phase picker and an earthquake relocation algorithm can illuminate unknown fault structures, and deliver information that can be synthesized for earthquake forecasting. We found that 80% of the larger earthquakes that occurred in the past decade could have been anticipated based on the spatial extent of the seismicity clusters that were formed before these earthquakes occurred. We also found that once a seismicity cluster with a length scale enough to host a larger earthquake was formed, there was a ~5% chance that it would host one or more larger earthquakes within a year. This probability is nearly an order of magnitude higher than one based on Gutenberg–Richter statistics and preceding seismicity. Applying our approach in practice can provide critical information on seismic hazards for risk management and regulatory decision making.

58 GEOSCIENCES↗

Basement rock hybrid drilling

A method for monitoring and controlling a downhole pressure of a well during formation of a borehole of a well is provided. The method can include monitoring a downhole pressure of a well during formation of a borehole of the well using a millimeter wave drilling apparatus including a waveguide configured for insertion into the borehole. The monitoring can include determining the downhole pressure. The downhole pressure can include an amount of pressure present at a bottom of the well. The method can also include determining a lithostatic pressure of rock surrounding the well at the bottom of the well. The method can further include controlling the downhole pressure relative to the lithostatic pressure of the rock surrounding the well at the bottom of the well. Related systems performing the methods are also provided.

Araque, Carlos↗

Basement rock hybrid drilling

A system for monitoring borehole parameters and switching to millimeter wave drilling based on the borehole parameters is provided. The system can include a mechanical drilling apparatus for forming a first portion of a borehole of a well. The first portion of the borehole can be formed based on a permeability of the first portion of the borehole and a temperature within the first portion of the borehole. The system can also include a millimeter wave drilling apparatus configured to inject millimeter wave radiation energy into a second portion of the borehole of the well via a waveguide. The second portion of the borehole can be formed via the millimeter wave drilling apparatus in response to determining the permeability of the first portion of the borehole is below a permeability threshold value and the temperature within the first portion of the borehole exceeds a temperature threshold value.

Araque, Carlos↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

Thermally Significant Fluid Seepage Through Thick Sediment on the Juan de Fuca Plate Entering the Cascadia Subduction Zone

We use heat flux measurements colocated with seismic reflection profiles over a buried basement high on the Juan de Fuca plate ∼25 km seaward of the deformation front offshore Oregon to test for the presence of hydrothermal circulation in the oceanic crust. We also revisit heat flux data crossing a buried basement high ∼25 km seaward of the deformation front ∼150 km north, offshore Washington. Seafloor heat flux is inversely correlated with sediment thickness, consistent with vigorous hydrothermal circulation in the basement aquifer homogenizing temperatures at the top of the basement. Heat flux immediately above the summit of the basement highs is greater than expected solely from conduction. Fluid seepage at rates of ∼2.6–5.4 cm yr −1 in a 1–1.5 km-wide conduit through ∼800–1,300 m thick sediment sections above these basement highs can explain these observations. Observations of thermally significant fluid seepage through sediment >225 m thick on oceanic crust are unprecedented. High sediment permeability, high fluid overpressure in the basement, or a combination of both is required to drive fluid seepage at the observed rates. We infer that rapid seepage occurs because the basement highs rise above the low permeability basal sediment with their tops protruding into the base of high permeability Nitinat or Astoria Fan sediment. Seepage from basement highs penetrating into the submarine fans can affect the thermal state of crust entering the subduction zone.

58 GEOSCIENCES↗

E-Area Low-Level Waste Facility Inadvertent Human Intruder Limits and Doses in Support of the PA2022

This report documents the inadvertent human intruder (IHI) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the Savannah River Site (SRS), near Aiken, South Carolina. This analysis supports the revised ELLWF Performance Assessment (PA), complying with the Department of Energy standard for operation of low-level waste disposal facilities (USDOE, 2017). The ELLWF is an operating waste disposal facility and is scheduled to continue accepting waste to 2065. One task of the revised PA is to establish waste inventory limits for the various disposal units at ELLWF. This is done by modeling future contaminant release and transport through applicable pathways to human receptors, comparing predicted doses per disposed curie with applicable performance measures, to obtain inventory limits which will assure that doses to receptors do not exceed performance measures. This report documents results of modeling future doses to one class of receptor, the inadvertent human intruder. It is assumed that after site closure, public knowledge of the site is lost, and IHIs will engage in activities on the ELLWF that will disrupt the closure cap, causing dose to the IHI. Following USDOE (2017), six different stylized exposure scenarios are considered, simulating activities by an IHI which could result in a radiological dose. The six scenarios are: • Acute – Basement Construction: IHI constructs a basement and encounters waste during excavation which is inadvertently mixed with clean soil and diluted. • Acute – Well Drilling: IHI drills a water well through waste and is exposed to drill cuttings mixed with clean soil that are brought to the surface. • Acute – Discovery: IHI begins constructing a basement but stops when encountering the riprap in the final closure cap and is exposed to photon radiation from unexcavated material residing in the undisturbed waste zone. • Chronic – Agriculture: Resident IHI is exposed to waste that was excavated for basement construction and mixed with native soil in the intruder’s vegetable garden. • Chronic – Post-Drilling: Resident IHI is exposed to waste from drill cuttings mixed with native soil and scattered in the garden area. • Chronic – Residential: Resident IHI is exposed to external radiation while in home located above waste with shielding provided by the concrete basement floor and any soil or engineered material remaining between the basement and waste. Dose calculations are performed using the SRNL Dose Toolkit (Aleman, 2023), following the approach of Smith et al (2019). Calculations are performed separately for 27 of the 33 disposal units (DUs) at ELLWF and are radionuclide specific. The results of the IHI analysis include: • Dose Factors: mrem per disposed curie (acute) and mrem/yr per disposed curie (chronic) for each parent radionuclide, for each DU. • Inventory Limits: in curies, for each parent radionuclide, for each DU. • Estimated Dose to IHI: mrem (acute) and mrem/yr (chronic), for each DU, given its projected closure inventory without inventory biases applied. Most DU-specific IHI inventory limits are in the range of 10 3 to 10 7 curies per nuclide. The lowest inventory limits are associated with gamma-emitters such as Sn-126, Ra-226, Th-232, and Cm-248. Radionuclides with short half-lives such as Pu-241, and nuclides which are pure beta emitters or which decay by electron capture, such as Ni-59 and Ni-63, have the highest limits. For the 27 evaluated DUs, predicted IHI doses are shown in Table ES-1. The maximum acute dose is 1.18 mrem, at ST23, much less than the DOE performance measure of 500 mrem (USDOE, 2017). The highest chronic dose is 37.2 mrem/yr at ST02, below the DOE performance measure of 100 mrem/yr. Also shown are estimated inventory sums of fractions (SOFs) at closure in 2065, for groundwater (GW) and IHI pathways. For each DU, the inventory is constrained by the GW pathway. For most DUs, the IHI SOFs are approximately 1000 times lower than the GW SOF values, and the IHI pathway does not drive risk for any disposal unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗