Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline performance reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Baseline Performance Reference for Irradiance in PV System Applications

This report proposes the definition of a new baseline performance reference (BPR). The definition goes beyond existing standards pertaining to photovoltaic (PV) reference cells and devices to define the response under all possible operating conditions in the field. Field evaluations using BPR devices will be more sensitive to performance anomalies than pyranometers because they track PV system power output more closely. At the same time, they will be able to detect a broader range of performance anomalies than traditional matched reference devices, which might have matching defects. The BPR definition also opens the door to new practices in resource assessment and yield prediction. Solar resource data can be collected or modeled and validated directly as BPR irradiance, and PV system simulations based on BPR irradiance need fewer assumptions and less processing to obtain the effective irradiance on modules. As a result, lower uncertainty in yield assessments can be expected.

14 SOLAR ENERGY↗

Introducing the Baseline Performance Reference (BPR) for Irradiance in PV System Applications

Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).

baseline performance reference↗

CharIN Megawatt Charging System: 4 th Event Summary Report

Medium- and heavy-duty electric vehicles require higher charging power levels than are supported by present light-duty EV charging standards. The Charging Interface Initiative (CharIN) Megawatt Charging System (MCS) Task Force is undertaking efforts to develop a new high-power charging standard for medium- and heavy-duty vehicle electrification. The fourth MCS evaluation event at NREL focused on thermal and mechanical performance evaluations of high-power MCS electric vehicle charging connectors and inlets from several different manufacturers, at current levels up to 3000A. Additionally, the event evaluated the performance of a reference inlet design, which will provide a baseline level of thermal performance for use in future evaluation and certification efforts of MCS connectors.

33 ADVANCED PROPULSION SYSTEMS↗

Performance, Combustion and Emissions Evaluation of Liquid Phase Port-Injected LPG on a Single Cylinder Heavy-Duty Spark Ignited Engine

Liquefied petroleum gas (LPG), like many other alternative fuels, has witnessed increased adoption in the last decade, and its use is projected to rise as stricter emissions regulations continue to be applied. However, much of its use is limited to dual fuel applications, gaseous phase injection, light-duty passenger vehicle applications, or scenarios that require conversion from gasoline engines. Therefore, to address these limitations and discover the most efficient means of harnessing its full potential, more research is required in the development of optimized fuel injection equipment for liquid port and direct injection, along with the implementation of advanced combustion strategies that will improve its thermal efficiency to the levels of conventional fuels. This paper focuses on the development of a liquid phase port-injection system for LPG, the design of a reference piston, and the baseline evaluation of the performance, combustion, and emissions characteristics of a single cylinder research engine to establish a benchmark comparable to existing LPG engines. A sweep of start of injection (SOI) timing is performed by injecting liquid LPG at several closed and open intake valve timings, which demonstrates no significant variation in engine performance, but accounts for a 10% reduction in bsCO with the optimal SOI timing. Spark timing sweep demonstrates the 50% burn crank angle location related to maximum brake torque (MBT) point with a brake thermal efficiency (BTE) of ~34% for the tested load case. The effect of equivalence ratio is also presented with optimal SOI timing at MBT condition. The engine starts exhibiting knocking combustion at 140kPa intake manifold air pressure (IMAP) with a peak torque of 253Nm and a 5% reduction in brake specific fuel consumption compared to the naturally aspirated scenario.

Fosudo, Toluwalase↗

Bench-scale Development of a Transformational Graphene Oxide-based Membrane Process for Post-combustion CO 2 Capture

Graphene-based materials, such as graphene and graphene oxide (GO), have been considered as next-generation membrane materials. GTI Energy and The State University of New York at Buffalo (UB) have been developing a transformational GO-based membrane process (designated as GO2) that integrates a high CO 2 /N 2 selectivity membrane (GO-1) and a high CO 2 flux membrane (GO-2) for post-combustion CO 2 capture. An innovative membrane structure, consisting of GO nanochannels intercalated by single-walled carbon nanotube (SWCNT), was developed. The membrane prepared on hollow fiber substrate showed CO 2 permeance as high as 1,300 GPU with CO 2 /N 2 selectivity >200. The membranes were successfully scaled up to effective area of 50-100 cm 2 . The 50-100 cm 2 membranes showed CO 2 /N 2 selectivity ≥200 and CO 2 permeance ≥1,000 GPU for the GO-1 type, and CO 2 /N 2 selectivity ≥20 and CO 2 permeance ≥2,500 GPU for the GO-2 type. The CO 2 capture performance of the GO-based membranes was tested using a simulated flue gas. The testing results indicate that the GO-based membranes are stable in the presence of flue gas contaminants. The GO-based membranes were then further scaled up to a surface area of 1,000 cm 2 . Good stability was achieved during an integrated testing with GO-1 and GO-2 membranes using simulated flue gas. A bench-scale system was designed, constructed, and tested at the National Carbon Capture Center (NCCC). Good stability was achieved during testing of a single-stage process with >10 shutdowns/startups at NCCC. During the integrated testing, the membranes showed good stability at 50°C and 57°C. 70-90% CO 2 removal efficiencies and ≥95% CO 2 purity were validated during the steady state operation at NCCC. Techno-economic analysis indicates the GO2 membrane-based process technology provides a reduction in both the levelized cost of electricity (LCOE) and cost of capture when compared to the reference B12B case presented in the Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity study prepared by the National Energy Technology Laboratory (NETL), before considering any system optimization or improvement opportunities. The benefits are primarily driven by a reduction in the equipment costs of the CO 2 capture process vs. the solvent-based reference process in NETL Case B12B as well as a decrease in the base plant size.

20 FOSSIL-FUELED POWER PLANTS↗

Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

As the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of RMI Ejecta Sourcing from Reconstructed Interfaces in 2D FLAG Flyer-Plate Simulations

This study investigates the performance of RMI ejecta sourcing from a reconstructed interface in two-dimensional FLAG ejecta flyer-plate simulations. Enabling the RMI ejecta model to operate on reconstructed interfaces has been a longstanding challenge in FLAG, limiting its applicability to experiments in which interface reconstruction is not required. Addressing this limitation is therefore an important step toward expanding the model’s predictive capability. The first phase of this effort focused on identifying a flyer-plate/target configuration that produces large ejecta clouds from two distinct shocks using the standard RMI ejecta model. A series of simulations examined the effects of flyer composition, layer thickness, and mesh resolution on shock structure and ejecta formation. VISAR traces were used to evaluate shock timing and identify configurations that produced a clear double-shock response. A copper middle-layer flyer with a doubled tin layer yielded the most favorable shock characteristics and was selected as the baseline configuration. After confirming this configuration performed as expected when running a reference FLAG version, it became the basis for three simulations: (1) a standard two-dimensional ejecta flyer-plate calculation using a reference FLAG version, (2) the same calculation with the reconstructed interface option enabled, and (3) a calculation employing ALE strategies to force the ejecta model to operate on the reconstructed interface. While the baseline simulation produced the expected ejecta response, the reconstructed interface approach did not result in measurable ejecta, indicating that this capability remains under development. These results highlight both the progress made and the remaining challenges in extending the RMI ejecta model to reconstructed interfaces.

36 MATERIALS SCIENCE↗

Bituminous Coal and Natural Gas to Electricity: >90% Capture Cases Technical Note

This technical note provides cost and performance estimates for post combustion carbon capture (PCCC) systems designed for greater than 90 percent capture on conventional PC- and NG-fueled power plants. The cost and performance estimates provided here were developed using the National Energy Technology Laboratory’s (NETL’s) well-documented methodology for conducting technoeconomic analysis of fossil energy conversion systems and leveraging published performance and cost projections for higher capture rate systems. Included in this technical note is a brief description of the method used to adjust select 90 percent capture cases from NETL’s Cost and Performance Baselines for Fossil Energy Systems Volume 1: Bituminous Coal and Natural Gas to Electricity, hereafter referred to as the Baseline Study. This technical note is intended to serve as an interim update to NETL’s Baseline Study cases by providing cost and performance estimates for high capture PCCC technology that can be deployed in the near-term at fossil-fueled electricity generating units.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Microgrid Design Toolkit (MDT) Simple Use Case Example for Islanded Mode Optimization (Software v1.3)

This simple Microgrid Design Toolkit (MDT) use case will provide you an example of a basic microgrid design. It will introduce basic principles of using the MDT islanded mode optimization by modifying a baseline microgrid design and performing an analysis of the results. Please reference the MDT User Guide (SAND2020-4550) for detailed instructions on how to use the tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Throughput Source-less Plasma Deposition of Structured Silicon Anodes for Lithium-Ion Batteries

Amprius developed a manufacturing solution for silicon nanowire anode that relies on an inexpensive, high throughput, and high gas precursor utilization plasma deposition method that uses the anode foils as electrodes for plasma generation. The capacitively couple plasma (CCP) method is used in semiconductor and photovoltaic industry and Amprius modified existing high throughput equipment to use anode foils and to deposit amorphous silicon. The equipment was installed ahead of the program at Amprius site. The rest of the tasks included foil handling and process development. The equipment passed site acceptance tests (SAT) and the process parameter mapping was completed, indicating that the target process window limits produce output materials at the rate and with yield and specifications that meet the manufacturing target criteria. Amprius has hired supporting personnel to optimize processes and run the equipment. A parallel task verified the baseline performance of the silicon anode material, to be used as reference for the new manufacturing method.

25 ENERGY STORAGE↗

Species Transport Framework Development in SAM for System-Level Tritium Source Term Analysis

The SAM code is under development as a modern system-level modeling and simulation tool for advanced non–light water reactor safety analyses, with recent efforts to add capabilities to evaluate radiological source term risks in these novel reactor concepts. By leveraging the established system-level multiphysics thermal-hydraulic models in SAM, a framework for tightly coupled species transport modeling has been integrated into the code for engineering-scale source term evaluation. This species transport framework was first applied to the simulation of tritium, which is a well-known source term in conventional light water reactors. Tritium poses a unique risk in salt-cooled reactors, especially those with lithium-bearing salts such as the fluoride salt–cooled high-temperature reactor (FHR) concept, as tritium is generated in the salt coolant in significant quantities due to neutron interactions. A compounding factor is the increased mobility of tritium at high temperatures, which is able to permeate through metals while also potentially being retained in graphite pebbles and structures. Engineering-scale models for the tritium transport pathways in a FHR have been developed using the new species transport framework in SAM. The capabilities are assessed through analytical verification problems and validated with data from a graphite retention experiment. In conclusion, the system-level model is demonstrated by performing an initial estimate of baseline tritium generation and flows in a generic reference SAM FHR model, setting a foundation for future studies of source term transient analysis with the potential for further multiscale and multiphysics integration.

SAM↗

A Systematic Framework for Projecting the Future Cost of Offshore Wind Energy

Offshore wind costs are expected to decline rapidly in the short and medium term future as the industry grows and gains experience in manufacturing, installing, and operating commercial scale projects. Estimating the future costs of offshore wind energy is critical for evaluating the technology's economic performance, how it can fit into a broader clean energy economy, and how R&D investment can be allocated to advance the technology. We present a newly developed approach for forecasting these costs which focuses on an empirically-derived learning rate for capital costs and prescribed cost and performance improvements for operational costs and capacity factor. We establish baseline costs for a series of reference fixed-bottom and floating projects in 2021 and project cost trajectories to 2035, presenting both an average cost trajectory as well as describing the range of potential future costs associated with site-specific cost variations and uncertainty in the estimate of the learning rate. We also conduct sensitivity analyses showing the impact of different global deployments by 2035 and variations in the prescribed operational costs and capacity factors. The results show that fixed-bottom and floating offshore wind capital costs could decrease to around $\$$2,400/kW and $\$$3,300/kW by 2035, respectively, with ranges of $\$$2,100/kW - $\$$2,750/kW for fixed-bottom projects and $\$$2,850/kW - $\$$5,500/kW for floating projects. The levelized cost of energy of fixed-bottom and floating wind projects could decrease to $\$$53.1/MWh and $\$$63.9/MWh by 2035, with ranges of $\$$48.4/MWh - $\$$59.7/MWh for fixed-bottom projects and $\$$46.5/MWh - $\$$99.9/MWh for floating projects. By presenting the uncertainty associated with the forecast we provide a transparent description of the spectrum of potential cost trajectories for offshore wind.

17 WIND ENERGY↗

Creep and Fatigue Characterization of High Strength Alloy Thin Sections in Advanced CO2 Heat Exchangers

The objective of this work was to characterize and model elevated temperature creep and fatigue behavior for thin sheet and foil forms of gamma-prime strengthened alloys in wrought form and as-processed folded and brazed constructions. This work was motivated by the demanding temperature and pressure service conditions of the GEN3 Concentrated Solar Power (CSP) and supercritical CO2 (sCO2) power cycle working fluid. More specifically, the possibility of leveraging the superior creep strength of gamma-prime alloys in folded-fin and brazed-plate heat exchanger constructions. Gamma-prime alloys represent a step-change in raw-material strength over solid-solution strengthened alloys. And the folded-fin and brazed-plate heat exchanger architecture is lightweight and leverages cost-effective material stock forms. The investigation contained two parallel paths. (1) The first is referred to as a fundamental investigation where Oak Ridge National Laboratory conducts uniaxial creep testing on thin sheet and foil in wrought form. This effort aimed to serve as a benchmark against a relatively sparse existing database and a baseline comparison for path number 2. (2) The second path is referred to as the practical investigation where Brayton Energy manufactures plate-fin heat exchangers and performs pressurized creep and fatigue testing. This effort aimed to de-risk heat exchanger manufacturing process for service under sCO2 CSP conditions. A total of 14 uniaxial creep tests were completed using Haynes 282 thin sheet and foil. A variety of heat treatments were specified to coincide with path number 2. Baseline metallography of test samples and creep strength performance are contained. Benchmarks relatively to existing thick-form Haynes 282 are made, as well as to other thin-form Nickel-based superalloys. Description of a wrought-form modeling approach for thin gamma-prime alloys is also discussed. A total of 11 pressurized creep and fatigue tests were completed successfully with Haynes 282 heat exchanger prototypes. Manufacturing processing details, testing details, testing results, and failure analysis are discussed. Additionally, creep modeling techniques to predict failure are discussed, and modeling to support technological-to-market. In conclusion, Haynes 282 foils were demonstrated to yield rupture two-to-three orders of magnitude higher than Haynes 230 foils under similar conditions. And the manufactured heat exchanger prototypes demonstrated strength similar to the wrought constituents. Both of which contribute to elevated performance potential or cost savings in practice. Discussion is included.

14 SOLAR ENERGY↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Synoptic VLBI Technique for Localizing Nonrepeating Fast Radio Bursts with CHIME/FRB

We demonstrate the blind interferometric detection and localization of two fast radio bursts (FRBs) with subarcminute precision on the 400 m baseline between the Canadian Hydrogen Intensity Mapping Experiment (CHIME) and the CHIME Pathfinder. In the same spirit as Very Long Baseline Interferometry (VLBI), the telescopes were synchronized to separate clocks, and the channelized voltage (herein referred to as baseband) data were saved to a disk with correlation performed offline. The simultaneous wide field of view and high sensitivity required for blind FRB searches implies a high data rate—6.5 terabits per second (Tb/s) for CHIME and 0.8 Tb s{sup −1} for the Pathfinder. Since such high data rates cannot be continuously saved, we buffer data from both telescopes locally in memory for ≈40 s, and write to the disk upon receipt of a low-latency trigger from the CHIME Fast Radio Burst Instrument (CHIME/FRB). The ≈200 deg{sup 2} field of view of the two telescopes allows us to use in-field calibrators to synchronize the two telescopes without needing either separate calibrator observations or an atomic timing standard. In addition to our FRB observations, we analyze bright single pulses from the pulsars B0329+54 and B0355+54 to characterize systematic localization errors. Our results demonstrate the successful implementation of key software, triggering, and calibration challenges for CHIME/FRB Outriggers: cylindrical VLBI outrigger telescopes which, along with the CHIME telescope, will localize thousands of single FRB events with sufficient precision to unambiguously associate a host galaxy with each burst.

47 OTHER INSTRUMENTATION↗