Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

An Iterative Bidirectional Gradient Boosting Algorithm for CVR Baseline Estimation

This paper presents a novel iterative, bidirectional, gradient boosting (bidirectional-GB) algorithm for estimating the baseline of the Conservation Voltage Reduction (CVR) program. We define the CVR baseline as the load profile during the CVR period if the substation voltage is not lowered. The proposed algorithm consists of two key steps: selection of similar days and iterative bidirectional-GB training. In the first step, preand post-event temperature profiles of the targeted CVR day are used to select similar days from historical non-CVR days. In the second step, the pre-event and post-event similar days are used to train two GBMs iteratively: a forward-GBM and a backwardGBM. After each iteration, the two generated CVR baselines are reconciled and only the first and the last points on the reconciled baseline are kept. The iteration repeats until all CVR baseline points are generated. We tested two gradient boosting methods (i.e., GBM and LighGBM) with two data resolutions (i.e., 15and 30-minute). The results demonstrate that both the accuracy and performance of the algorithm are satisfactory.

Lee, Han Pyo↗

Irrigation Infrastructure and Modernization – Setting a Baseline: Estimates of Irrigation Water Conveyance Infrastructure Extents and Composition and the Potential Water, Energy, and Economic Benefits of Modernization in the Western U.S.

In the Western United States (U.S.), water delivery for irrigation is still largely managed using century-old equipment and designs. Modernization of this vital water conveyance infrastructure, such as piping of earthen canals, is known to improve water availability and water quality for farmers, while saving energy and enabling new hydropower. However, there is sparse information about the extent of irrigation water delivery infrastructure, which makes it challenging to estimate the cost of upgrades at scale and the potential benefits of accelerating modernization work. This report estimates a variety of previously unquantified data points related to irrigation water delivery infrastructure in the Western U.S. to support stakeholders interested in nationwide modernization planning. The findings should be considered approximations, useful for understanding the scale, range, or variability of these indicators. Taken together, the findings of this report illustrate some of the challenges and opportunities involved in modernizing the agricultural water delivery infrastructure in the Western U.S. Accelerating the pace of modernization could strengthen the long-term resilience of U.S. food systems while providing significant economic, energy, water, and environmental benefits.

13 HYDRO ENERGY↗

Continental United States may lose 1.8 petagrams of soil organic carbon under climate change by 2100

Abstract Aims High‐resolution information on soils’ vulnerability to climate‐induced soil organic carbon (SOC) loss can enable environmental scientists, land managers, and policy makers to develop targeted mitigation strategies. This study aims to estimate baseline and decadal changes in continental US surface SOC stocks under future emission scenarios. Location Continental United States. Time period 2014–2100. Methods We used recent SOC field observations ( n = 6,213 sites), environmental factors ( n = 32), and an ensemble machine learning (ML) approach to estimate baseline SOC stocks in surface soils across the continental United States at 100‐m spatial resolution, and decadal changes under the projected climate scenarios of Coupled Model Intercomparison Project Phase Six (CMIP6) earth system models (ESMs). Results Baseline SOC projections from ML approaches captured more than 50% of variability in SOC observations, whereas ESMs represented only 6–16% of observed SOC variability. ML estimates showed a mean total loss of 1.8 Pg C from US surface soils under the high‐emission scenario by 2100, whereas ESMs showed no significant change in SOC stocks with wide variation among ESMs. Both ML and ESM predictions agree on the direction of SOC change (net emissions or sequestration) across 46–51% of continental US land area. These differences are attributable to the high‐resolution site‐specific data used in the ML models compared to the relatively coarse grid represented in CMIP6 ESMs. Main conclusions Our high‐resolution estimates of baseline SOC stocks, identification of key environmental controllers, and projection of SOC changes from US land cover types under future climate scenarios suggest the need for high‐resolution simulations of SOC in ESMs to represent the heterogeneity of SOC. We found that the SOC change is sensitive to key soil related factors (e.g. soil drainage and soil order) that have not been historically considered as input parameters in ESMs, because currently more than 95% variability in the SOC of CMIP6 ESMs is controlled by net primary productivity, temperature, and precipitation. Using additional environmental factors to estimate the baseline SOC stocks and predict the future trajectory of SOC change can provide more accurate results.

54 ENVIRONMENTAL SCIENCES↗

Modeling spatial patterns in soil arsenic to estimate natural baseline concentrations

ABSTRACT Arsenic in soil is an important public health concern. Toxicity guidelines and models based on laboratory studies (i.e., U.S. EPA’s Integrated Risk Information System) should consider natural soil As concentrations to avoid unnecessary remediation burdens on society. We used soil and stream sediment samples from the USGS National Geochemical Survey database to assess the spatial distribution of natural As in a 1.16E+5 km2 area. Samples were collected at 348 soil and 144 stream locations, providing approximately one sample for every 290 km2. Sample sites were selected to minimize the potential influence of anthropogenic inputs. Samples were processed using acid digestion of whole samples (concentrated HCl and ascorbic acid) and concentrations were measured using hydride-generation atomic absorption spectrometry. Soil As ranged from 2.0 to 45.6 mg kg-1. Geostatistical techniques were used to model and map the spatial variability of As. The mean and variance at unsampled locations were estimated using sequential Gaussian simulation. Five areas of elevated concentration (> the median of 10 mg kg-1) were identified and the relationships to geologic parent materials, glacial sedimentation patterns, and soil conditions interpreted. Our results showed As concentrations >10 mg kg-1 were common, and >20 mg kg-1 were not unusual for the central and west central portions of Ohio (USA). In contrast, concentrations <4 mg kg-1 were rare. Measured concentrations typically exceeded the soil As human generic screening levels of 0.39 mg/kg (1); the calculated value that corresponds to a cancer risk level of 1 in 1,000,000 for soil ingestion. Because the As content of Ohio soils is similar to many world soils, the USEPA generic soil screening level of 0.39 mg/kg is of little utility. A more useful and practical approach would be the uses of natural background levels. Regional soil As patterns based on geology and biogeochemistry and not political boundaries should be used for soil screening and other risk assessment determinations.

arsenic, background, mapping, geostatistics, toxic↗

Myriad World Baseline: Global Geodemographic Estimates

The LandScan Myriad World Baseline (MWB) method produces global, residential (nighttime/home-location) gridded geodemographic estimates based on 5-year age/gender cohorts—at 30-arcsecond (≈1 km) resolution. MWB is designed to fill gaps where detailed, georeferenced survey data (e.g., Demographic and Health Surveys (DHS)) are missing or outdated, and to provide a baseline that can support human security analysis, including consequence assessment, “patterns of life” modeling, and scenario-based population futures. MWB’s workflow spatializes household-level age/gender characteristics from the GLOPOP-S dataset by conflating household and gridded expected relative wealth adapted from Global Gridded Relative Deprivation Index (GRDI), then adjusts them to a target year of interest. Age/gender estimates are then applied to harmonize lowest-administrative-level statistics with LandScan residential counts, yielding final geodemographic estimates. Two validation case studies are presented: Ghana (2021) and Tokyo/Kanagawa, Japan (2020), illustrating spatial variability in demographic cohorts and comparing MWB outputs to official gridded statistics. Results show close overall alignment relative to validation criteria including population pyramids and age-dependency ratios.

Tuccillo, Joe [ORNL] (ORCID:0000000259300943)↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Estimating the Benefits of Sustainable Aviation Fuel Usage at Chicago O’Hare International Airport on Ultrafine Particle Exposure and Mortalities Reductions

The expanding commercial aviation sector necessitates diverse energy sources, and sustainable aviation fuels (SAFs) have emerged as a promising option. Widespread SAF adoption can help meet transportation fuel demand and offer health benefits for people residing near airports or along airport landing and takeoff (LTO) pathways, where elevated levels of aircraft-derived air pollution often exist. Blending SAF with traditional jet fuels can reduce ultrafine particle (UFP) emissions, which may improve health of near airport population. We analyzed a population of about 8 million people in 1925 census tracts around the Chicago O’Hare International Airport (ORD). We conducted a risk assessment to estimate anticipated UFP reductions for three adoption scenarios using blends of traditional jet fuels with 5, 25, and 50% SAF across all flights landing and taking off from ORD. We calculated baseline estimates of UFP emissions using ORD flight data, a dispersion model, and a calibration function derived from mobile monitoring data. We used this baseline UFP emission profile across the study area to estimate population-weighted UFP, as well as the attributable case reductions (ACRs) and attributable mortality rate reductions (AMRRs) across the demographic distribution around the airport, based on the SAF blending scenarios. We found a positive association of SAF blending with UFP reductions, particularly near the airport and along LTO flight pathways. Our study showed that the population-weighted UFP across different demographics was similar. ACRs were largely dependent on individual demographic populations, while AMRRs for all populations were relatively similar, with an estimated 0.3 (95% range: 0.2−0.3), 1.1 (0.9−1.4), and 1.8 (1.5−2.2) fewer mortalities per 100,000 people per year expected with the adoption of 5, 25, and 50% SAF blends, respectively. This study indicates that communities near ORD, across a range of demographics, may benefit similarly from SAF adoption, thus highlighting how SAF adoption may offer an opportunity to improve health outcomes like aviation UFP-related mortalities around airports.

10 SYNTHETIC FUELS↗

The Realistic Potential of Soil Carbon Sequestration in U.S. Croplands for Climate Mitigation

Existing estimates of the climate mitigation potential from cropland carbon sequestration (C-sequestration) are limited because they tend to assume constant rates of soil organic carbon change over all available cropland area, use relatively coarse land delineations, and often fail to adequately consider the agronomic and socioeconomic dimensions of agricultural land use. This results in an inflated estimate of the C-sequestration potential. We address this gap by defining a more appropriate land base for cover cropping in the United States for C-sequestration purposes: stable croplands in annual production systems that can integrate cover cropping without irrigation. Our baseline estimate of this suitable stable cropland area is 32% of current U.S. cropland extent. Even an alternative, less restrictive definition of stability results in a large reduction in area (44% of current U.S. croplands). Focusing cover crop implementation to this constrained land base would increase durability of associated C-sequestration and limit soil carbon loss from land conversion to qualify for carbon-specific incentives. Applying spatially-variable C-sequestration rates from the literature to our baseline area yields a technical potential of 19.4 Tg CO 2 e yr –1 annually, about one-fifth of previous estimates. We also find the cost of realizing about half (10 Tg CO 2 e yr –1 ) of this potential could exceed 100 USD Mg CO 2 e –1 , an order of magnitude higher than previously thought. While our economic analyses suggest that financial incentives are necessary for large-scale adoption of cover cropping in the U.S., they also imply any C-sequestration realized under such incentives is likely to be additional.

54 ENVIRONMENTAL SCIENCES↗

Effect Of Ventilation On Chronic Health Risks In Schools And Offices

This study provides a risk assessment for chronic health risks from inhalation exposure to indoor air pollutants in offices and schools with a focus how ventilation impacts exposures to, and risks from, volatile organic compounds (VOCs) and particulate matter (PM2.5). We estimate how much health risks could change with varying ventilation rates under two scenarios: (i) halving the measured ventilation rates and (ii) doubling the measured ventilation rates. For the hazard characterization we draw upon prior papers that identified pollutants potentially affecting health with indoor air concentrations responsive to changes in ventilation rates. For exposure assessment we determine representative concentrations of pollutants using data available in current literature and model changes in exposures with changes in ventilation rates. As a metric of disease burden, we use disability adjusted life years (DALYs) to address both cancer and non-cancer effects. We also compare exposures to guidelines published by regulatory agencies to assess chronic health risks. Chronic health risks are driven primarily by particulate matter exposure, with an estimated baseline disease burden of 150 DALYs per 100,000 people in offices and 140 DALYs per 100,000 people in schools. Study results show that PM2.5-related DALYs are not very sensitive to changes in ventilation rates. Filtration is more effective at controlling PM2.5 concentrations and health effects. Non-cancer health effects contribute only a small fraction of the overall chronic health burden of populations in offices and schools (<1 DALY per 100,000 people). Cancer health effects dominate the disease burden in schools (3 DALYs per 100,000) and offices (5 DALYs per 100,000), with formaldehyde being the primary risk driver. In spite of large uncertainties in toxicological data and dose-response modeling, our results support the finding that ventilation rate changes do not have significant impacts on estimated chronic disease burdens. Median estimates of DALYs are approximately doubled when the ventilation rates are halved and there is little reduction in health risks associated with doubling ventilation rates, but the very low baseline disease burden from the indoor exposures we considered makes this unremarkable. In exploring the full range of exposure concentrations, to find the fraction exceeding the Office of Environmental Health and Hazard Assessment’s (OEHHAs) chronic reference exposure levels (cRELs) and United States Environmental Protection Agency’s (USEPA) chronic reference dose (RfD) we found only minor shifts in exposure safety margins when ventilation was doubled or halved. We combined our exposure estimates with cancer potency factors published by OEHHA and USEPA to determine that the annual excess cancer risk per capita are below 1 in a million under all ventilation rate scenarios for individual pollutants. The results indicate that chronic health risks (cancer and non-cancer) associated with VOC and PM2.5 exposure in offices and schools are low and thus the chronic disease burden or health benefits of ventilation changes are likely to be well below both the level of detection by health surveillance studies and the level of regulatory thresholds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at INL. Additionally, INL has a desire to see how its emissions compare with similar institutions, including other DOE national laboratories. Executive Order 13514 requires that federal agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL's FY08 GHG inventory was calculated according to methodologies identified in federal GHG guidance documents using operational control boundaries. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL's organizational boundaries but are a consequence of INL's activities). This inventory found that INL generated a total of 113,049 MT of CO2-equivalent emissions during FY08. The following conclusions were made from looking at the results of the individual contributors to INL's baseline GHG inventory: (1) Electricity (including the associated transmission and distribution losses) is the largest contributor to INL's GHG inventory, with over 50% of the CO2e emissions; (2) Other sources with high emissions were stationary combustion (facility fuels), waste disposal (including fugitive emissions from the onsite landfill and contracted disposal), mobile combustion (fleet fuels), employee commuting, and business air travel; and (3) Sources with low emissions were wastewater treatment (onsite and contracted), fugitive emissions from refrigerants, and business ground travel (in personal and rental vehicles). This report details the methods behind quantifying INL's GHG inventory and discusses lessons learned on better practices by which information important to tracking GHGs can be tracked and recorded. It is important to note that because this report differentiates between those portions of INL that are managed and operated by the Battelle Energy Alliance (BEA) and those managed by other contractors, it includes only that large proportion of Laboratory activities overseen by BEA. It is assumed that other contractors will provide similar reporting for those activities they manage, where appropriate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at the INL. Additionally, the INL has a desire to see how its emissions compare with similar institutions, including other DOE-sponsored national laboratories. Executive Order 13514 requires that federally-sponsored agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL’s FY08 GHG inventory was calculated according to methodologies identified in Federal recommendations and an as-yet-unpublished Technical and Support Document (TSD) using operational control boundary. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL’s organizational boundaries but are a consequence of INL’s activities). This inventory found that INL generated a total of 114,256 MT of CO2-equivalent emissions during fiscal year 2008 (FY08). The following conclusions were made from looking at the results of the individual contributors to INL’s baseline GHG inventory: • Electricity is the largest contributor to INL’s GHG inventory, with over 50% of the net anthropogenic CO2e emissions • Other sources with high emissions were stationary combustion, fugitive emissions from the onsite landfill, mobile combustion (fleet fuels) and the employee commute • Sources with low emissions were contracted waste disposal, wastewater treatment (onsite and contracted) and fugitive emissions from refrigerants. This report details the methods behind quantifying INL’s GHG inventory and discusses lessons learned on better practices by which information important to tracking GHGs can be tracked and recorded. It is important to stress that the methodology behind this inventory followed guidelines that have not yet been formally adopted. Thus, some modification of the conclusions may be necessary as additional guidance is received. Further, because this report differentiates between those portions of the INL that are managed and operated by the Battelle Energy Alliance (BEA) and those managed by other contractors, it includes only that large proportion of Laboratory activities overseen by BEA. It is assumed that other contractors will provide similar reporting for those activities they manage, where appropriate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodological Approaches for Estimating the Benefits and Costs of Smart Grid Demonstration Projects

This report presents a comprehensive framework for estimating the benefits and costs of Smart Grid projects and a step-by-step approach for making these estimates. The framework identifies the basic categories of benefits, the beneficiaries of these benefits, and the Smart Grid functionalities that lead to different benefits and proposes ways to estimate these benefits, including their monetization. The report covers cost-effectiveness evaluation, uncertainty, and issues in estimating baseline conditions against which a project would be compared. The report also suggests metrics suitable for describing principal characteristics of a modern Smart Grid to which a project can contribute. This first section of the report presents background information on the motivation for the report and its purpose. Section 2 introduces the methodological framework, focusing on the definition of benefits and a sequential, logical process for estimating them. Beginning with the Smart Grid technologies and functions of a project, it maps these functions to the benefits they produce. Section 3 provides a hypothetical example to illustrate the approach. Section 4 describes each of the 10 steps in the approach. Section 5 covers issues related to estimating benefits of the Smart Grid. Section 6 summarizes the next steps. The methods developed in this study will help improve future estimates - both retrospective and prospective - of the benefits of Smart Grid investments. These benefits, including those to consumers, society in general, and utilities, can then be weighed against the investments. Such methods would be useful in total resource cost tests and in societal versions of such tests. As such, the report will be of interest not only to electric utilities, but also to a broad constituency of stakeholders. Significant aspects of the methodology were used by the U.S. Department of Energy (DOE) to develop its methods for estimating the benefits and costs of its renewable and distributed systems integration demonstration projects as well as its Smart Grid Investment Grant projects and demonstration projects funded under the American Recovery and Reinvestment Act (ARRA). The goal of this report, which was cofunded by the Electric Power Research Institute (EPRI) and DOE, is to present a comprehensive set of methods for estimating the benefits and costs of Smart Grid projects. By publishing this report, EPRI seeks to contribute to the development of methods that will establish the benefits associated with investments in Smart Grid technologies. EPRI does not endorse the contents of this report or make any representations as to the accuracy and appropriateness of its contents. The purpose of this report is to present a methodological framework that will provide a standardized approach for estimating the benefits and costs of Smart Grid demonstration projects. The framework also has broader application to larger projects, such as those funded under the ARRA. Moreover, with additional development, it will provide the means for extrapolating the results of pilots and trials to at-scale investments in Smart Grid technologies. The framework was developed by a panel whose members provided a broad range of expertise.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial and Temporal Correlates of Greenhouse Gas Diffusion from a Hydropower Reservoir in the Southern United States

Emissions of CO 2 and CH 4 from freshwater reservoirs constitute a globally significant source of atmospheric greenhouse gases (GHGs), but knowledge gaps remain with regard to spatiotemporal drivers of emissions. We document the spatial and seasonal variation in surface diffusion of CO 2 and CH 4 from Douglas Lake, a hydropower reservoir in Tennessee, USA. Monthly estimates across 13 reservoir sites from January to November 2010 indicated that surface diffusions ranged from 236 to 18,806 mg m -2 day -1 for CO 2 and 0 to 0.95 mg m -2 day -1 for CH 4 . Next, we developed statistical models using spatial and physicochemical variables to predict surface diffusions of CO 2 and CH 4 . Models explained 22.7 and 20.9% of the variation in CO 2 and CH4 diffusions, respectively, and identified pH, temperature, dissolved oxygen, and Julian day as the most informative important predictors. These findings provide baseline estimates of GHG emissions from a reservoir in eastern temperate North America a region for which estimates of reservoir GHGs emissions are limited. Our statistical models effectively characterized non-linear and threshold relationships between physicochemical predictors and GHG emissions. Further refinement of such models will aid in predicting current GHG emissions in unsampled reservoirs and forecasting future GHG emissions.

54 ENVIRONMENTAL SCIENCES↗