Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION

A Method for Estimation and Suppression of Quasi-Periodic Noise

Electromagnetic interference, particularly from sources such as light fixtures and power supplies, negatively affects the function and performance of electronic systems. This noise, often quasi-periodic in nature, contains harmonic structure that can be used for noise estimation and suppression. This work proposes a novel method for tracking and filtering such noise signals that reduces the comb filter bandwidth required for noise estimation and suppression by tracking the instantaneous frequency of the fundamental component.

42 ENGINEERING

GalaxyFlow: upsampling hydrodynamical simulations for realistic mock stellar catalogues

ABSTRACT Cosmological N-body simulations of galaxies operate at the level of ‘star particles’ with a mass resolution on the scale of thousands of solar masses. Turning these simulations into stellar mock catalogues requires ‘upsampling’ the star particles into individual stars following the same phase-space density. In this paper, we introduce two new upsampling methods. First, we describe GalaxyFlow, a sophisticated upsampling method that utilizes normalizing flows to both estimate the stellar phase-space density and sample from it. Secondly, we improve on existing upsamplers based on adaptive kernel density estimation (KDE), using maximum likelihood estimation to fine-tune the bandwidth for such algorithms in a way that improves both the density estimation accuracy and upsampling results. We demonstrate our upsampling techniques on a neighbourhood of the Solar location in two simulated galaxies: Auriga 6 and h277. Both yield smooth stellar distributions that closely resemble the stellar densities seen in the Gaia DR3 catalogue. Furthermore, we introduce a novel multimodel classifier test to compare the accuracy of different upsampling methods quantitatively. This test confirms that GalaxyFlow more accurately estimates the density of the underlying star particles than methods based on KDE, at the cost of being more computationally intensive.

Lim, Sung Hak (ORCID:0000000330981092)

A Measurement of Atmospheric Circular Polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 yr of observational data with the POLARBEAR project. Nonidealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While POLARBEAR detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is 0.92 ± 0.01(stat) ± 0.07(sys). This ratio corresponds to a brightness temperature of 3.8 mK at the effective band center of 121.8 GHz and bandwidth of 3.5 GHz estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measure circular polarization in such experiments.

79 ASTRONOMY AND ASTROPHYSICS

A Vibrational Energy Harvesting Sensor Based on Linear and Rotational Electromechanical Effects

In this investigation, a magnetically coupled double-spring design is presented for harvesting low-level non-stationary random vibrational energy. The sensor relies on multimodal coupling between the translation and rotation of a two-spring magnet and coil system to widen the harvesting bandwidth. Energy methods are used to develop a model to characterize the electromechanical response of the system, the solution of which is obtained using stochastic techniques based on a particle swarm algorithm. This approach provides an efficient method to estimate system parameters that otherwise are difficult or impossible to determine with independent measurements. The experimental results demonstrate agreement with the theoretical predictions over a limited bandwidth. The sensor can effectively harvest non-stationary vibration energy down to 10 -4 g within a limited bandwidth of 130–150 Hz. The sensor prototype has an operational volume of 2.6 cm 3 with a calculated power density of 0.2 W/cm 3 . The sensor’s small size results in a coupling efficiency of approximately 6% across the tested bandwidth.

42 ENGINEERING

Multitaper Magnitude‐Squared Coherence for Time Series With Missing Data: Understanding Oscillatory Processes Traced by Multiple Observables

To explore the hypothesis of a common source of variability in two time series, observers may estimate the magnitude-squared coherence (MSC), which is a frequency-domain view of the cross correlation. For time series that do not have uniform observing cadence, MSC can be estimated using Welch's overlapping segment averaging. However, multitaper has superior statistical properties to Welch's method in terms of the tradeoff between bias, variance, and bandwidth. The classical multitaper technique has recently been extended to accommodate time series with underlying uniform observing cadence from which some observations are missing. This situation is common for solar and geomagnetic data sets, which may have gaps due to breaks in satellite coverage, instrument downtime, or poor observing conditions. We demonstrate the scientific use of missing-data multitaper magnitude-squared coherence by detecting known solar mid-term oscillations in simultaneous, missing-data time series of solar Lyman α flux and geomagnetic Disturbance Storm Time index. Due to their superior statistical properties, we recommend that multitaper methods be used for all heliospheric time series with underlying uniform observing cadence.

Astro-statistics techniques (1886)

HPC Network Simulation Tuning via Automatic Extraction of Hardware Parameters

Popular HPC network interconnection simulators such as SST/macro provide a variety of configurable parameters to explore the design space of hardware components such as network interface cards (NIC), switches, and links among them. While such knobs provide flexibility to explore design trade-offs for novel hardware, manually configuring simulations for matching configurations of the existing hardware to focus on topology exploration can be cumbersome and error-prone, leading to widely inaccurate simulations. This challenge is compounded when specifications of various (proprietary) technologies are not readily available or intentionally omitted. In this work, we propose a framework to autotune the multiple network models’ simulation configurations within SST/macro using Tree-structured Parzen Estimator-based Bayesian optimization to observe the effect on simulation accuracy across different message regimes. These regimes consist of small to large message sizes and latency to bandwidth-bound messages. We provide a detailed analysis of the simulation error for four representative HPC systems. Our Bayesian optimization based autotuning framework for network models achieves a maximum of 5x improvement in accuracy over best-effort manual configurations based on available hardware specifications.

Simulation, autotuning

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES

Resonant inelastic x-ray scattering in warm-dense Fe compounds beyond the SASE FEL resolution limit

Resonant inelastic x-ray scattering (RIXS) is a widely used spectroscopic technique, providing access to the electronic structure and dynamics of atoms, molecules, and solids. However, RIXS requires a narrow bandwidth x-ray probe to achieve high spectral resolution. The challenges in delivering an energetic monochromated beam from an x-ray free electron laser (XFEL) thus limit its use in few-shot experiments, including for the study of high energy density systems. Here we demonstrate that by correlating the measurements of the self-amplified spontaneous emission (SASE) spectrum of an XFEL with the RIXS signal, using a dynamic kernel deconvolution with a neural surrogate, we can achieve electronic structure resolutions substantially higher than those normally afforded by the bandwidth of the incoming x-ray beam. We further show how this technique allows us to discriminate between the valence structures of Fe and Fe2O3, and provides access to temperature measurements as well as M-shell binding energies estimates in warm-dense Fe compounds.

74 ATOMIC AND MOLECULAR PHYSICS

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background

Search for electroweak-scale dijet resonances using trigger-level analysis with the ATLAS detector in 132 fb −1 of 𝑝⁢𝑝 collisions at $\sqrt{𝑠}$ = 13 TeV

This article reports on a search for dijet resonances using 132 fb −1 of 𝑝⁢𝑝 collision data recorded at $\sqrt{𝑠}$ = 13 TeV by the ATLAS detector at the Large Hadron Collider. The search is performed solely on jets reconstructed within the ATLAS trigger to overcome bandwidth limitations imposed on conventional single-jet triggers, which would otherwise reject data from decays of sub-TeV dijet resonances. Collision events with two jets satisfying transverse momentum thresholds of 𝑝 T ≥ 85 GeV and jet rapidity separation of |𝑦*| <0.6 are analysed for dijet resonances with invariant masses from 375 to 1800 GeV. A data-driven background estimate is used to model the dijet mass distribution from multijet processes. No significant excess above the expected background is observed. Upper limits are set at 95% confidence level on coupling values for a benchmark leptophobic axial-vector 𝑍′ model and on the production cross section for a new resonance contributing a Gaussian-distributed line-shape to the dijet mass distribution.

hadron colliders

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Entanglement-enhanced ac magnetometry in the presence of Markovian noise

Entanglement is a resource to improve the sensitivity of quantum sensors. In an ideal case, using an entangled state as a probe to detect target fields, we can beat the standard quantum limit by which all classical sensors are bounded. However, since entanglement is fragile against decoherence, it is unclear whether entanglement-enhanced metrology is useful in a noisy environment. Its benefit is indeed limited when estimating the amplitude of dc magnetic fields under the effect of parallel Markovian decoherence, where the noise operator is parallel to the target field. In this paper, on the contrary, we show an advantage to using an entanglement over the classical strategy under the effect of parallel Markovian decoherence when we try to detect ac magnetic fields. We consider a scenario to induce a Rabi oscillation of the qubits with the target ac magnetic fields. Although we can, in principle, estimate the amplitude of the ac magnetic fields from the Rabi oscillation, the signal becomes weak if the qubit frequency is significantly detuned from the frequency of the ac magnetic field. We show that, by using the Greenberger-Horne-Zeilinger (GHZ) states, we can significantly enhance the signal of the detuned Rabi oscillation even under the effect of parallel Markovian decoherence. Further, our method is based on the fact that the interaction time between the GHZ states and ac magnetic fields scales as 1/L to mitigate the decoherence effect, where L is the number of qubits, which contributes to improving the bandwidth of the detectable frequencies of the ac magnetic fields. Our results pave the way for new applications of entanglement-enhanced ac magnetometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

The effective number of parameters in kernel density estimation

We devise a new formula for measuring the effective degrees of freedom (EDoF) in kernel density estimation (KDE). Starting from the orthogonal polynomial sequence (OPS) expansion for the ratio of the empirical to the oracle density, we show how convolution with the kernel leads to a new OPS with respect to which one may express the resulting KDE. The expansion coefficients of the two OPS systems can then be related via a kernel sensitivity matrix, which leads to a natural oracle definition of EDoF through the trace operator. Asymptotic properties of the (empirical) plug-in EDoF are worked out through influence functions, and connections with other empirical EDoFs are established. Minimization of Kullback-Leibler divergence is investigated as an alternative to integrated squared error based bandwidth selection rules, yielding a new normal scale rule. The methodology, which arises from a proper oracle formulation and is not restricted to convolution kernels, suggests the possibility of a new bandwidth selection rule based on an information criterion such as AIC.

bandwidth selection