At least 19 records

Investigating late-stage particle production in pp collisions with balance functions

Balance functions have been regarded in the past as a method of investigating the late-stage hadronization found in the presence of a strongly-coupled medium. They are also used to constrain mechanisms of particle production in large and small collision systems. Charge balance functions for inclusive and identified particle pairs are reported as a function of charged particle multiplicity in proton–proton collisions simulated with the PYTHIA8 and the EPOS4 models. The charge balance functions of inclusive, pion, kaon, and proton pairs exhibit amplitudes and shapes that depend on particle species and differ significantly in the two models due to the different particle production mechanisms implemented in PYTHIA and EPOS. The shapes and amplitudes also evolve with multiplicity in both models. In addition, the evolution of the longitudinal rms width and that of balance functions integrals with multiplicity (and average transverse momentum) feature significant differences in the two models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed-species charge and baryon balance functions studies with PYTHIA

Mixed species charge and baryon balance functions are computed based on proton-proton ( p p ) collisions simulated with the PYTHIA8 model. Simulations are performed with selected values of the collision energy s and the Monash tune and the ropes and shoving modes of PYTHIA8 to explore whether such measurements provide useful new information and constraints on mechanisms of particle production in p p collisions. Charge balance functions are studied based on mixed pairs of pions, kaons, and protons, whereas baryon balance functions are computed for mixed low mass strange and nonstrange baryons. Both charge and baryon balance functions of mixed particle pairs feature shapes and amplitudes that sensitively depend on the particle considered owing largely to the particle production mechanisms implemented in PYTHIA. The evolution of balance functions integrals with the longitudinal width of the acceptance are presented and one finds that sums of such integrals for a given reference particle obey expected sum rules for both charge and baryon balance functions. Additionally, both types of balance functions are found to evolve in shape and amplitude with increasing collision energy s and the PYTHIA tunes considered. Published by the American Physical Society 2024

Physics↗

Balance Function Disorders

Researchers at the Balance Function Laboratory and Clinic at the Minneapolis (MN) Neuroscience Institute on the Abbot Northwestern Hospital Campus are using a rotational chair (technically a "sinusoidal harmonic acceleration system") originally developed by NASA to investigate vestibular (inner ear) function in weightlessness to diagnose and treat patients with balance function disorders. Manufactured by ICS Medical Corporation, Schaumberg, IL, the chair system turns a patient and monitors his or her responses to rotational stimulation.

Source record↗

Multiplicity and transverse momentum dependence of charge-balance functions in pPb and PbPb collisions at LHC energies

Measurements of the charge-dependent two-particle angular correlation function in proton-lead (pPb) collisions at a nucleon-nucleon center-of-mass energy of $\sqrt{s_{NN}}$ = 8.16 TeV and lead-lead (PbPb) collisions at $\sqrt{s_{NN}}$ = 5.02 TeV are reported. The pPb and PbPb data sets correspond to integrated luminosities of 186 nb -1 and 0.607 nb -1 , respectively, and were collected using the CMS detector at the CERN LHC. The charge-dependent correlations are characterized by balance functions of same- and opposite-sign particle pairs. The balance functions, which contain information about the creation time of charged particle pairs and the development of collectivity, are studied as functions of relative pseudorapidity (Δη) and relative azimuthal angle (Δφ), for various multiplicity and transverse momentum (p T ) intervals. A multiplicity dependence of the balance function is observed in Δη and Δφ for both systems. The width of the balance functions decreases towards high-multiplicity collisions in the momentum region < 2 GeV, for pPb and PbPb results. Integrals of the balance functions are presented in both systems, and a mild dependence of the charge-balancing fractions on multiplicity is observed. No multiplicity dependence is observed at higher transverse momentum. The data are compared with HYDJET, HIJING, and AMPT generator predictions, none of which capture completely the multiplicity dependence seen in the data. The comparison of results with different center-of-mass energies suggests that the balance functions become narrower at higher energies, which is consistent with the idea of delayed hadronization and the effect of radial flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/ sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain s ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable providing imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles.

Bloomberg, Jacob↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗

Using baryonic charge balance functions to resolve questions about the baryo-chemistry of the quark gluon plasma

Baryon annihilations during the hadronic stage of heavy-ion collisions affects final-state baryon and antibaryon yields and final-state correlations of baryons and antibaryons. Understanding annihilation is important for addressing questions about the chemistry at the beginning of the hadronic stage and for interpreting charge-balance correlations involving baryons. Here, charge balance functions, using protons and antiprotons binned by relative momentum, rapidity, and azimuthal angle are shown to clarify the amount of annihilation in the hadronic stage. This enables a more accurate extraction of the baryo-chemistry at the beginning of the hadronic stage. Understanding annihilation is also crucial if charge balance correlations are to be used to infer the chemistry of the earliest stages of a heavy-ion collision. Furthermore, calculations are presented based on microscopic simulations of the hadronic stage coupled to a hydrodynamic description of the earlier stage, along with a detailed modeling of correlations of protons and antiprotons, known as charge-balance functions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge balance functions for heavy-ion collisions at energies available at the CERN Large Hadron Collider

Heavy-ion collisions at the Large Hadron Collider provide the conditions to investigate regions of quark-gluon plasma that reach higher temperatures and that persist for longer periods of time compared with collisions at the Relativistic Heavy Ion Collider. This extended duration allows correlations from charge conservation to better separate during the quark-gluon plasma phase, and thus be better distinguished from correlations that develop during the hadron phase or during hadronization. Here, charge balance functions binned by relative rapidity and azimuthal angle and indexed by species are considered. A detailed theoretical model that evolves charge correlations throughout the entirety of an event is compared with preliminary results from the ALICE Collaboration. The comparison with experiment provides insight into the evolution of the chemistry and diffusivity during the collision. A ratio of balance functions is proposed to better isolate the effects of diffusion and thus better constrain the diffusivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probe Chiral Magnetic Effect with Signed Balance Function

In this paper a pair of observables are proposed as alternative ways, by examining the fluctuation of net momentum-ordering of charged pairs, to study the charge separation induced by the Chiral Magnetic Effect (CME) in relativistic heavy ion collisions. They are, the out-of-plane to in-plane ratio of fluctuation of the difference between signed balance functions measured in pair’s rest frame, and the ratio of it to similar measurement made in the laboratory frame. In this work, both observables have been studied with simulations including flow-related backgrounds, and for the first time, backgrounds that are related to resonance's global spin alignment. The two observables have similar positive responses to signal, and opposite, limited responses to identifiable backgrounds arising from resonance flow and spin alignment. Both observables have also been tested with two realistic models, namely, a multi-phase transport (AMPT) model and the anomalous-viscous fluid dynamics (AVFD) model. These two observables, when cross examined, will provide useful insights in the study of CME-induced charge separation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

General balance functions of identified charged hadron pairs of (π, Κ, ρ) in Pb-Pb collisions at $\sqrt{s_{NN}}$ = 2.76 TeV

First measurements of balance functions (BFs) of all combinations of identified charged hadron (π, Κ, ρ) pairs in Pb–Pb collisions at $\sqrt{s_{NN}}$ = 2.76 TeV recorded by the ALICE detector are presented. The BF measurements are carried out as two-dimensional differential correlators versus the relative rapidity (Δy) and azimuthal angle (Δφ) of hadron pairs, and studied as a function of collision centrality. The Δφ dependence of BFs is expected to be sensitive to the light quark diffusivity in the quark–gluon plasma. While the BF azimuthal widths of all pairs substantially decrease from peripheral to central collisions, the longitudinal widths exhibit mixed behaviors: BFs of ππ and cross-species pairs narrow significantly in more central collisions, whereas those of KK and pp are found to be independent of collision centrality. This dichotomy is qualitatively consistent with the presence of strong radial flow effects and the existence of two stages of quark production in relativistic heavy-ion collisions. Finally, the first measurements of the collision centrality evolution of BF integrals are presented, with the observation that charge balancing fractions are nearly independent of collision centrality in Pb–Pb collisions. Overall, the results presented provide new and challenging constraints for theoretical models of hadron production and transport in relativistic heavy-ion collisions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Test of Functional Balance Theory for Wetland Biomass Allocation in a Global Change Experiment

Abstract Forecasts of root growth and carbon sequestration under global change are compromised by uncertainty in how plants will allocate biomass between above and belowground pools. Here, we develop a simple model to assess whether functional balance theory can explain a complex biomass allocation response observed in a brackish marsh under experimental warming and elevated CO 2 . Our model shows how treatment‐driven changes in nitrogen supply and demand can explain divergent observations of root growth (i.e., maximum responses under intermediate warming and elevated CO 2 ). The model also reveals a surprising interaction between warming and eutrophication, where enhanced N loading to coastal marshes may reduce adverse impacts of warming on root growth. Our findings provide a mechanistic basis for incorporating biomass allocation into forecast models of marsh evolution. They also provide a general example of using ecological theory to decompose complex net responses observed in multi‐factor global change experiments into constituent processes.

54 ENVIRONMENTAL SCIENCES↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗

Stimulus Characteristics for Vestibular Stochastic Resonance to Improve Balance Function

Stochastic resonance (SR) is a mechanism by which noise can enhance the response of neural systems to relevant sensory signals. Studies have shown that imperceptible stochastic vestibular electrical stimulation, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the amplitude characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standard balance task of standing on a block of foam with their eyes closed. Bipolar stochastic electrical stimulation was applied to the vestibular system using constant current stimulation through electrodes placed over the mastoid process behind the ears. Amplitude of the signals varied in the range of 0-700 microamperes. Balance performance was measured using a force plate under the foam block, and inertial motion sensors were placed on the torso and head. Balance performance with stimulation was significantly greater (10%-25%) than with no stimulation. The signal amplitude at which performance was maximized was in the range of 100-300 microamperes. Optimization of the amplitude of the stochastic signals for maximizing balance performance will have a significant impact on development of vestibular SR as a unique system to aid recovery of function in astronauts after long-duration space flight or in patients with balance disorders.

Mulavara, Ajitkumar↗

Optimization of Stimulus Characteristics for Vestibular Stochastic Resonance to Improve Balance Function

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Recent studies have shown that applying imperceptible stochastic noise electrical stimulation to the vestibular system significantly improved balance and ocular motor responses. The goal of this study was to optimize the amplitude of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10-cm-thick medium-density foam with their eyes closed. Balance performance was measured using a force plate under the foam block and using inertial motion sensors placed on the torso and head segments. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process. Subjects were tested at seven amplitudes in the 0.01-30Hz frequency range. The root mean square of the signal increased by 30 microamperes for each +/-100 microampere increment in the current range of 0 - +/-700 microampere. Six balance parameters were calculated to characterize the performance of subjects during the baseline and the stimulus periods for all seven amplitudes. Optimal stimulus amplitude was determined as the one at which the ratio of parameters from the stimulus period to the baseline period for any amplitude range was less than that for the no stimulus condition on a minimum of four of six parameters. Results from this study showed that balance performance at the optimal stimulus amplitude showed significant improvement with the application of the vestibular SR stimulation. The amplitude of optimal stimulus for improving balance performance in normal subjects was in the range of +/-100 - +/-300 microamps.

Mulavara, Ajitkumar↗

Determine Optimal Stimulus Amplitude for Using Vestibular Stochastic Stimulation to Improve Balance Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface [1]. This technique to improve detection of vestibular signals uses a stimulus delivery system that provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for sensorimotor adaptability (SA) training applications customized to each crewmember. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds [2]. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s long sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower. In the balance task, subjects stood on an unstable surface and had to maintain balance, and the stimulation was administered from 20-400% of subjects' vestibular threshold. Optimal stimulation amplitude was determined at which the balance performance was best compared to control (no stimulation). Preliminary results show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold significantly improved the balance performance. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination may help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.