Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic load balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Asynchronous distributed-memory task-parallel algorithm for compressible flows on unstructured 3D Eulerian grids

Here, we discuss the implementation of a finite element method, used to numerically solve the Euler equations of compressible flows, using an asynchronous runtime system (RTS). The algorithm is implemented for distributed-memory machines, using stationary unstructured 3D meshes, combining data-, and task-parallelism on top of the Charm++ RTS. Charm++’s execution model is asynchronous by default, allowing arbitrary overlap of computation and communication. Task-parallelism allows scheduling parts of an algorithm independently of, or dependent on, each other. Built-in automatic load balancing enables continuous redistribution of computational load by migration of work units based on real-time CPU load measurement. The RTS also features automatic checkpointing, fault tolerance, resilience against hardware failure, and supports power-, and energy-aware computation. We demonstrate scalability up to 25 x 10 9 cells at $\mathscr{O}$10 4 compute cores and the benefits of automatic load balancing for irregular workloads. The full source code with documentation is available at https://quinoacomputing.org.

42 ENGINEERING↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

pnnl/mcl-runtime

The Minos Computing Library (MCL) is a task-based programming language and runtime for extremely heterogeneous systems. MCL facilitates writing program for heterogeneous devices and porting applications across different systems and devices. MCL supports asynchronous execution of computing tasks on all available heterogeneous devices, including GPUs, FGPAs, fixed-point accelerators, and AI accelerators. MCL provides a high-level programming interface and automatically and autonomously performs resource management, load balancing, and locality-aware scheduling.

Central, PNNL Developer↗

Multi-Segment Decentralized Control Strategies for Renewables-Rich Microgrids in Extreme Conditions

Microgrids provide a promising approach to accommodating various distributed energy resources (DERs), while requiring significant communication infrastructures that may be affected by extreme conditions such as natural disasters and cyber-attacks. In this paper, a fully decentralized control strategy without the need for communication is proposed for islanded microgrids with high renewables penetration. First, special multi-segment power/frequency characteristic curves are designed, so that different DERs can be automatically coordinated in a prioritized manner such as renewables first to maintain power balance while DER frequencies are regulated at their reference values. Second, piecewise linear served load versus frequency models are designed to prioritize loads according to their significance, so that only noncritical loads will be curtailed as needed while critical loads are supplied without any interruptions during power deficiency. The proposed strategy can effectively deal with various normal and extreme system conditions including 100% renewables penetration, loads and renewables variations, power deficiencies requiring load curtailments, disconnection of existing DERs, connection of new DERs as well as network sectionalization and reconfiguration. As a result, the proposed control strategy is validated in the real-time digital simulator (RTDS) model of the IIT Campus Microgrid to demonstrate its effectiveness in enhancing the resiliency of renewables-rich microgrids in extreme conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DISTRI: Distributed Multi-Facility HPC Simulator (DISTRI) v2.1

DISTRI is an advanced network simulator designed for multi-facility computational infrastructures with agentic behavior. It simulates HPC facilities where computational resources act as autonomous agents, making intelligent decisions about job scheduling, load balancing, and resource allocation. The simulator focuses on developing and testing decentralized algorithms that promote resilience and efficiency in multi-facility environments. Key Features: - Agentic Resource Behavior: Processors and DTNs act as autonomous agents with decision-making capabilities - Pheromone-Based Load Balancing: Decentralized load balancing inspired by ant colony optimization - Dual Topology Support: Mesh (normal operations) and Dumbell (network testing) topologies - Comprehensive TCP Simulation: Realistic TCP implementations with multiple congestion control algorithms - Failure Resilience Testing: Processor failure simulation with automatic job reassignment - Extensive Visualization: Detailed performance analysis and metrics collection - Research-Ready: Designed for algorithm development and benchmarking

Bez, Jean Luca [Lawrence Berkeley National Laborat↗

GreenThrift: Optimizing Carbon and Cost for Flexible Residential Loads

Reducing buildings’ carbon emissions is an important sustainability challenge. While scheduling flexible building loads has been previously used for a variety of grid and energy optimizations, carbon footprint reduction using such flexible loads poses new challenges since such methods need to balance both energy and carbon costs while also reducing user inconvenience from delaying such loads. This paper highlights the potential conflict between electricity prices and carbon emissions and the resulting trade-offs in carbon-aware and cost-aware load scheduling. To address this trade-off, we propose GreenThrift, a home automation system that leverages the scheduling capabilities of smart appliances and knowledge of future carbon intensity and cost to reduce both the carbon emissions and costs of flexible energy loads. At the heart of GreenThrift is an optimization technique that automatically computes schedules based on user configurations and preferences. We evaluate the effectiveness of GreenThrift using real-world carbon intensity data, electricity prices, and load traces from multiple locations and across different scenarios and objectives. Our results show that GreenThrift can replicate the offline optimal and retains 97% of the savings when optimizing the carbon emissions. Moreover, we show how GreenThrift can balance the conflict between carbon and cost and retain 95.3% and 85.5% of the potential carbon and cost savings, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tri-Level Linear Programming Model for Automatic Load Shedding Using Spectral Clustering

Traditional load shedding schemes can be inadequate in grids with high renewable penetration, leading to unstable events and unnecessary grid islanding. Although for both manual and automatic operating modes load shedding areas have been predefined by grid operators, they have remained fixed, and may be sub-optimal due to dynamic operating conditions. In this work, a distributed tri-level linear programming model for automatic load shedding to avoid system islanding is presented. Preventing islanding is preferred because it reduces the need for additional load shedding besides the disconnection of transmission lines between islands. This is crucial as maintaining the local generation-demand balance is necessary to preserve frequency stability. Furthermore, uneven distribution of generation resources among islands can lead to increased load shedding, causing economic and reliability challenges. This issue is further compounded in modern power systems heavily dependent on non-dispatchable resources like wind and solar. The upper-level model uses complex power flow measurements to determine the system areas to shed load depending on actual operating conditions using a spectral clustering approach. The mid-level model estimates the area system state, while the lower-level model determines the locations and load values to be shed. The solution is practical and promising for real-world applications.

Baquedano-Aguilar, Mario D.↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peridynamic neural operators: A data-driven nonlocal constitutive model for complex material responses

Neural operators, which can act as implicit solution operators of hidden governing equations, have recently become popular tools for learning the responses of complex real-world physical systems. Nevertheless, most neural operator applications have thus far been data-driven and neglect the intrinsic preservation of fundamental physical laws in data. Here, in this work, we introduce a novel integral neural operator architecture called the Peridynamic Neural Operator (PNO) that learns a nonlocal constitutive law from data. This neural operator provides a forward model in the form of state-based peridynamics, with objectivity and momentum balance laws automatically guaranteed. As applications, we demonstrate the expressivity and efficacy of our model in learning complex material behaviors from both synthetic and experimental data sets. We also compare the performances with baseline models that use predefined constitutive laws. We show that, owing to its ability to capture complex responses, our learned neural operator achieves improved accuracy and efficiency. Moreover, by preserving the essential physical laws within the neural network architecture, the PNO is robust in treating noisy data. The method shows generalizability to different domain configurations, external loadings, and discretizations.

42 ENGINEERING↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Economic Dispatch Considering Transmission–Distribution Coordination and Automatic Regulation Effect

With the rapid increase of renewable energy sources, the variability and uncertainty in power systems are significantly increased, and the power system operation is facing more and more challenges. In the traditional dynamic economic dispatch (DED) of transmission systems, the frequency and voltage regulation effects are not actively utilized. In addition, the transmission systems and distribution systems are optimized separately; the transmission–distribution coordination effect is not considered. In this article, a new DED is proposed. The optimal scheduling results are obtained by making a balance between operating cost and reliability cost. Both the automatic regulation effect and transmission–distribution coordination effect are explored and exploited in terms of the equivalent reserve, which can reduce the reserve provided by generating units, and can further enhance the security and economics of power system operation. The validity and effectiveness of the proposed model are illustrated by case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗