Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “auditing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration and Validation of a Virtual Energy Audit Tool for DoD Buildings

Electricity consumption has been in the spotlight as part of the battle for sustainability resulting in legislative measures to try and reduce the amount of energy used. EISA 432 and the Energy Act of 2020 are two examples that require federal facilities to investigate buildings and find saving opportunities through energy audits. EDIFES solves this problem by providing fully virtual audits. Only five inputs are needed (15-minute interval electricity consumption, location, square footage, number of stories, and building end use) to produce complete energy audits. The virtual audit is automated, making them inexpensive and the small number of inputs allows a large number of buildings to be entered quickly. During this project, EDIFES performed energy audits on hundreds of buildings to ensure proper functionality and workflow. Over 250 DoD buildings received energy audits that then had their results posted to an interactive dashboard with portfolio rankings. Several validation methods were employed. All confirmed that EDIFES's methods worked as expected and with a high degree of accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desktop Audits: Overview, Case Studies, Guidance

The Energy Independence and Security Act (EISA) of 2007 requires that federal agencies audit 25% of their 3.1 billion square feet of covered facilities each year. Several newer, advanced options such as monitoring-based commissioning, fault detection and diagnostics, and energy management systems can help support data collection and analysis to be used for EISA compliance. The Federal Energy Management Program's (FEMP’s) Audit Decision Tree, Audit Definitions, and FEMP Guidance can be used by Agencies to determine the best approaches to evaluate their facilities. FEMP continues to develop additional resources to support agencies in meeting EISA compliance. This presentation gives an overview of desktop audits, including case studies and guidance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FEMP Facility Evaluation (Audit) Decision Tree

This document is a resource to be used in concert with FEMP Audit Definitions, FEMP Consolidated Facility Management Guidance, and agency best practices and expert judgment—for agencies to use to determine the best approaches to evaluate their facilities. It features a decision tree that provides a framework for agencies to interpret gathered facility data to understand the existing conditions; benchmark the facility against others in the portfolio to determine whether an on-site or remote audit is appropriate for a facility; determine the best remote or on-site audit level of detail to meet agency facility auditing goals, such as meeting Energy Independence and Security Act of 2007 requirements and developing projects; and improve their energy and water management programs.

auditing↗

Scaling Building Energy Audits through Machine Learning Methods on Novel Drone Image Data

Building energy audits are time-consuming and labor-intensive. This paper describes a new method using machine learning (ML) techniques on novel data sources (drone images) to improve the identification of building characteristics and retrofit opportunities, and thereby reduce the effort for audits. The new ML method includes: (1) Building footprint extraction using line extraction, polygonization, and polygon-merging, (2) Building envelope extraction using PIX4d modeling software to reconstruct a building 3D model, (3) Visualization tool for viewing images from the 3D model, (4) Window-to-wall ratio (WWR) using state-of-art deep neural network semantic segmentation, (5) Envelope thermal anomaly detection using an unsupervised machine learning clustering algorithm, and (6) Rooftop energy equipment detection based on an object detection algorithm. The testing of this method involved a comparison of additional ML-generated information overlaid on current ‘state-of-practice’ audit and remote assessment baselines using evaluation metrics: labor time and associated cost, marginal benefits of using ML-generated information in workflows for audits and remote assessments, integration potential with existing processes and tools, and replicability/scalability of the method. In two test buildings in California that had comprehensive drawings and meter data available, the ML method effectively generated a building footprint, envelope, rooftop equipment, WWR, and locations of envelope thermal anomalies. Projected target segments of the ML method are sites with minimal drawings and energy data, and underserved sectors such as multistoried housing, disadvantaged communities, and schools for which the ML method can enable identification of building asset characteristics and prioritization of envelope retrofits and decentralized energy equipment retrofits.

Singh, Reshma↗

CY20 AIHA Internal Audit of ALAB and NIF-HPL and CY20 Management Review of ALAB

An internal audit was performed in ALAB to ISO 17025:2017; EPA LQST and AIHA requirements using the current AIHA Checklist. The scope of the internal audit was the annual review of AIHA-accredited industrial hygiene methods performer in both ALAB and NIF HPL. The Internal audit resulted in 3 deficiencies and 3 comments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Document Traceability Internal Audit of the Analytical Laboratory Report on 08-26-2021

An internal audit was performed in ALAB 8/25/21 to the NELAC 2016 Standard requirements using the NELAC 2016 checklist (TNI 2016 CSDP-Volume1Checklist-Master-2-15-18-v9). The scope of the internal audit was a document traceability of the environmental testing in LRF-00118, LRF00095, and LRF 00133 performed in ALAB. The internal audit resulted in five deficiencies and two comments. The deficiencies were addressed using the ALAB non-conformance reporting system, see ALAB NCRs 10002742-10002746. FRM-5100 Management Observation and NCRs are attached.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analyzing the Multiscale Impacts of Implementing Energy-Efficient HVAC Improvements Through Energy Audits and Economic Input–Output Analysis

Abstract Heating, ventilation, and air-conditioning (HVAC) systems are usually an industry’s highest consumer of energy, most of which goes toward space cooling in buildings. Industrial energy-efficiency audits not only benefit manufacturers but also generate significant economic and environmental benefits to localities, states, and the nation. This article analyzes the micro- and macro scale impacts of implementing energy-efficient HVAC systems by integrating the industrial building energy data with the macroeconomic regional economic flow model. Micro-scale data include 10 years of historical energy, cost, and carbon dioxide savings achieved from energy-efficient HVAC implementation offered to manufacturers through industrial energy audits. The data were integrated into the macroeconomic modeling framework to illuminate the cascading regional economic impacts of implementing energy-efficient HVAC recommendations in manufacturing facilities. Results show that if recommendations had been implemented throughout all manufacturers in the region, $656 M energy costs would have been directly saved, 7.8 million metric tons of carbon dioxide emissions would have been avoided, and 4387 jobs could have been created, resulting in a total annual economic impact of $899 M stemming from direct, indirect, and induced impacts. The results offer insight into how industrial energy systems can be designed and provide models for how communities can accomplish a net-zero society.

Energy & Fuels↗

MFVI Energy Efficiency Audit Training - Module 1.1: Introduction to Efficient Lighting [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing lighting systems. As such, it will assist its user in determining the optimal lighting for a given space and then identifying the most efficient means of delivering that lighting.

21CPP↗

MFVI Energy Efficiency Audit Training - Module 1.2: Lighting Analysis [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing lighting systems. As such, it will assist its user in determining the optimal lighting for a given space and then identifying the most efficient means of delivering that lighting.

21CPP↗

MFVI Energy Efficiency Audit Training Module 2.2: Plug Loads Analysis [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

MFVI Energy Efficiency Audit Training Module 2.1: Plug Loads [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

Los Alamos National Laboratory Internal Audit Strategic Plan

Los Alamos National Laboratory (LANL or the Laboratory) is managed under a management and operations (M&O) contract by Triad National Security, LLC (Triad), a nonprofit, public-focused consortium that includes Battelle Memorial Institute, the Texas A&M University System, and the University of California. The Internal Audit Group (IA) at LANL creates a formal strategic plan every five years in order to establish longer-range goals and initiatives to ensure the group fulfills its purpose as established in the Audit Charter, conforms with relevant standards, and is focused on continuous improvement. This document establishes the five-year strategic plan for fiscal year’s (FY) 2024 - 2028.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Blockchain cybersecurity audit platform

A cybersecurity distributed ledger is provided herein for managing, tracking, auditing, and securing assets in a power infrastructure. The cybersecurity distributed ledger may include a blockchain, and may combine with smart contract or smart negotiation technology, such as in a permissioned proof of authority blockchain. The cybersecurity distributed ledger may manage the complete life cycle of a grid asset, from asset requirement and specification, through production, testing, deployment, maintenance, and retirement. The cybersecurity distributed ledger may create an immutable record of the grid asset, which may be audited for regulatory compliance or build or development compliance. Further, the cybersecurity distributed ledger may store unique identifying information for a grid asset, which may be used to detect a security breach or other tampering with a grid asset. The cybersecurity distributed ledger may also track control or ownership of the grid asset, as well as changes or updates to the grid asset.

Mylrea, Michael E.↗

Toward the Neutrino Discovery Platform: An Auditable, Uncertainty-Bearing Toolchain for MINERvA Open-Data Cross-Section Analysis

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

GHG Emissions Reduction Audit: A Checklist for Owners

This guidance and accompanying checklist detail recommended services and deliverables for a building-level greenhouse gas (GHG) emissions reduction audit focused on Scope 1 and 2 GHG emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Audits and Energy Efficiency in Support of Resilience

Presentation provides an overview of how facility energy and water efficiency audits can provide resilience benefits, how NREL's REopt Lite web tool optimizes the economic and resilience benefits of distributed energy resources, and how FEMP's Technical Resilience Navigator assesses risk to a site's critical functions and prioritizes solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗