Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atmospheric dilution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Changes in soluble sugar, starch, and alcohol dehydrogenase in Arabidopsis thaliana exposed to N2 diluted atmospheres

Proper exchange of atmospheric gases is important for normal root and shoot metabolism in plants. This study was conducted to determine how restricted air supply affects foliar carbohydrates, while using the marker enzyme alcohol dehydrogenase (ADH) to report on the oxygenation status of the rootzone. Fourteen-day-old Arabidopsis thaliana (L.) Heynh. plants grown singly in 7-ml tubes containing agarified nutrient medium were placed in coupled Magenta vessels and exposed for six days to either ambient air or one of six different air/nitrogen dilutions. Redox potential of the agar medium was measured immediately after harvesting and freezing leaf tissue, and then root systems were quickly extracted from the agar and frozen for subsequent analyses. Redox potential measurements indicated that this series of gas mixtures produced a transition from hypoxia to anoxia in the root zones. Root ADH activity increased at higher rates as the redox potential neared anoxic levels. In contrast, ADH mRNA expression quickly neared its maximum as the medium became hypoxic and showed little further increase as it became anoxic. Foliar carbohydrate levels increased 1.5- to 2-fold with decreased availability of metabolic gases, with starch increasing at higher concentrations of air than soluble carbohydrate. The results serve as a model for plant performance under microgravity conditions, where absence of convective air movement prevents replenishment of metabolic gases.

NASA Discipline Plant Biology↗

Limestone calcination with CO{sub 2} capture (II): decomposition in CO{sub 2}/steam and CO{sub 2}/N{sub 2} atmospheres

Decomposition of limestone particles (0.25-0.5 mm) in a steam dilution atmosphere (20-100% steam in CO{sub 2}) was investigated by using a continuously operating fluidized bed reactor for CO{sub 2} capture. The decomposition conversion of limestone increased as the steam dilution percentage in the CO{sub 2} supply gas increased. At a bed temperature of 1193 K, the conversions were 72% without dilution (100% CO{sub 2}) and 98% with 60% steam dilution. The decomposition conversions obtained with steam dilution and N{sub 2} dilution differed significantly, and this result is explained in terms of the difference between the heat transfer to particle in steam and N{sub 2} dilution atmosphere. The reactivities of the CaO produced from limestone decomposition with steam dilution and without dilution (100% CO{sub 2}) were tested by means of hydration and carbonation reactions. In the hydration test, the time required for complete conversion (CaO{yields}Ca(OH){sub 2}) of the CaO produced by steam dilution was approximately half that required for the CaO produced without dilution. In the carbonation test, carbonation conversion (CaO{yields}CaCO{sub 3}) of the CaO produced by steam dilution was approximately 70%, whereas the conversion was approximately 40% for the CaO produced without dilution. 17 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Breakthrough Zn(II) Catalyst for Direct Air Capture Employing CO 2 Hydration

Direct air capture (DAC) represents a vital technology for atmospheric CO₂ remediation, but few studies have tested catalysts at dilute atmospheric CO₂ concentrations. Inspired by the carbonic anhydrase metalloenzyme, we report a catalytic DAC strategy employing robust zinc(II) enzyme mimics that enable efficient CO₂ sequestration pathways. A catalyst-mediated CO₂ hydration cycle in aqueous sorbents facilitates accelerated capture from dilute atmospheric air, thereby addressing the kinetic limitations observed in carbonate-based systems. Our developed complexes [ZnC1] and [ZnC2] enhance capture rates up to two-fold at millimolar concentrations and improve CO₂ mass transfer by 40-60% in 1 M K₂CO₃ sorbent under ambient conditions. These bench-stable, earth-abundant zinc catalysts operate effectively under dilute CO₂ concentrations, overcoming the kinetic limitations of conventional carbonate-based sorbents. As a result, mechanistic studies support a biomimetic catalytic cycle that facilitates rapid CO₂ conversion, demonstrating that catalyst-assisted DAC can enable energy-efficient, scalable carbon capture technologies.

Atmospheric chemistry↗

Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Contributions of microgravity test results to the design of spacecraft fire-safety systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Droplet Combustion Experiment (DCE)

The first space-based experiments were performed on the combustion of free, individual liquid fuel droplets in oxidizing atmospheres. The fuel was heptane, with initial droplet diameters ranging about from 1 mm to 4 mm. The atmospheres were mixtures of helium and oxygen, at pressures of 1.00, 0.50 and 0.25 bar, with oxygen mole fractions between 20% and 40%, as well as normal Spacelab cabin air. The temperatures of the atmospheres and of the initial liquid fuel were nominally 300 K. A total of 44 droplets were burned successfully on the two flights, 8 on the shortened STS-83 mission and 36 on STS-94. The results spanned the full range of heptane droplet combustion behavior, from radiative flame extinction at larger droplet diameters in the more dilute atmospheres to diffusive extinction in the less dilute atmospheres, with the droplet disappearing prior to flame extinction at the highest oxygen concentrations. Quasisteady histories of droplet diameters were observed along with unsteady histories of flame diameters. New and detailed information was obtained on burning rates, flame characteristics and soot behavior. The results have motivated new computational and theoretical investigations of droplet combustion, improving knowledge of the chemical kinetics, fluid mechanics and heat and mass transfer processes involved in burning liquid fuels.

Haggard, John B., Jr.↗

Estimates of Radioxenon Released from Southern Hemisphere Medical isotope Production Facilities Using Measured Air Concentrations and Atmospheric Transport Modeling

Abstract The International Monitoring System (IMS) of the Comprehensive-Nuclear-Test-Ban-Treaty monitors the atmosphere for radioactive xenon leaking from underground nuclear explosions. Emissions from medical isotope production represent a challenging background signal when determining whether measured radioxenon in the atmosphere is associated with a nuclear explosion prohibited by the treaty. The Australian Nuclear Science and Technology Organisation (ANSTO) operates a reactor and medical isotope production facility in Lucas Heights, Australia. This study uses two years of release data from the ANSTO medical isotope production facility and Xe-133 data from three IMS sampling locations to estimate the annual releases of Xe-133 from medical isotope production facilities in Argentina, South Africa, and Indonesia. Atmospheric dilution factors derived from a global atmospheric transport model were used in an optimization scheme to estimate annual release values by facility. The annual releases of about 6.8×1014 Bq from the ANSTO medical isotope production facility are in good agreement with the sampled concentrations at these three IMS sampling locations. Annual release estimates for the facility in South Africa vary from 1.2×1016 to 2.5×1016 Bq and estimates for the facility in Indonesia vary from 6.1×1013 to 3.6×1014 Bq. Although some releases from the facility in Argentina may reach these IMS sampling locations, the solution to the objective function is insensitive to the magnitude of those releases.

07 ISOTOPE AND RADIATION SOURCES↗

Representative Atmospheric Plume Development for Elevated Releases

An atmospheric explosion of a low-yield nuclear device will produce a large number of radioactive isotopes, some of which can be measured with airborne detection systems. However, properly equipped aircraft may not arrive in the region where an explosion occurred for a number of hours after the event. Atmospheric conditions will have caused the radioactive plume to move and diffuse before the aircraft arrives. The science behind predicting atmospheric plume movement has advanced enough that the location of the maximum concentrations in the plume can be determined reasonably accurately in real time, or near real time. Given the assumption that an aircraft can follow a plume, this study addresses the amount of atmospheric dilution expected to occur in a representative plume as a function of time past the release event. The approach models atmospheric transport of hypothetical releases from a single location for every day in a year using the publically available HYSPLIT code. The effective dilution factors for the point of maximum concentration in an elevated plume based on a release of a non-decaying, non-depositing tracer can vary by orders of magnitude depending on the day of the release, even for the same number of hours after the release event. However, the median of the dilution factors based on releases for 365 consecutive days at one site follows a power law relationship in time, as shown in Figure S-1. The relationship is good enough to provide a general rule of thumb for estimating typical future dilution factors in a plume starting at the same point. However, the coefficients of the power law function may vary for different release point locations. Radioactive decay causes the effective dilution factors to decrease more quickly with the time past the release event than the dilution factors based on a non-decaying tracer. An analytical expression for the dilution factors of isotopes with different half-lives can be developed given the power law expression for the non-decaying tracer. If the power-law equation for the median dilution factor, Df, based on a non-decaying tracer has the general form Df=a(×t)^(-b) for time t after the release event, then the equation has the form Df=e^(-λt)×a×t^(-b) for a radioactive isotope, where λ is the decay constant for the isotope.

54 ENVIRONMENTAL SCIENCES↗

Soot surface temperature measurements in pure and diluted flames at atmospheric and elevated pressures

Soot surface temperature was measured in laminar jet diffusion flames at atmospheric and elevated pressures. The soot surface temperature was measured in flames at one, two, four, and eight atmospheres with both pure and diluted (using helium, argon, nitrogen, or carbon dioxide individually) ethylene fuels with a calibrated two-color soot pyrometry technique. These two dimensional temperature profiles of the soot aid in the analysis and understanding of soot production, leading to possible methods for reducing soot emission. Each flame investigated was at its smoke point, i.e., at the fuel flow rate where the overall soot production and oxidation rates are equal. The smoke point was chosen because it was desirable to have similar soot loadings for each flame. A second set of measurements were also taken where the fuel flow rate was held constant to compare with earlier work. These measurements show that overall flame temperature decreases with increasing pressure, with increasing pressure the position of peak temperature shifts to the tip of the flame, and the temperatures measured were approximately 10% lower than those calculated assuming equilibrium and neglecting radiation. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric plume progression as a function of time and distance from the release point for radioactive isotopes

The International Monitoring System contains up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear tests. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point.

atmospheric plume progression↗

DEPOSITION VELOCITY ESTIMATION WITH THE GENII V2 SOFTWARE

In 2010, the Department of Energy (DOE) Chief of Nuclear Safety and Office of Health, Safety and Security (HSS), with the support of industry experts in atmospheric sciences and accident dose consequences analysis, performed detailed analyses of the basis for the dry deposition velocity (DV) values used in the MACCS2 computer code. As a result of these analyses, DOE concluded that the historically used default DV values of 1 centimeter/second (cm/s) for unfiltered/unmitigated releases and 0.1 cm/s for filtered/mitigated releases may not be reasonably conservative for all DOE sites and accident scenarios. HSS recently issued Safety Bulletin 2011-02, Accident Analysis Parameter Update, recommending the use of the newly developed default DV, 0.1 cm/s for an unmitigated/unfiltered release. Alternatively site specific DV values can be developed using GENII version 2 (GENII v2) computer code. Key input parameters for calculating DV values include surface roughness, maximum wind speed for calm, particle size, particle density and meteorological data (wind speed and stability class). This paper will include reasonably conservative inputs, and a truncated parametric study. In lieu of the highly-conservative recommended DV value (0.1cm/s) for unmitigated/unfiltered release, GENII v2 has been used to justify estimated 95th percentile DV values. Also presented here are atmospheric dilution factors ({chi}/Q values) calculated with the MACCS2 code using the DV values form GENII v2, {chi}/Q values calculated directly with GENII v2, and a discussion of these results compare with one another. This paper will give an overview of the process of calculating DV with GENII v2 including a discussion of the sensitivity of input parameters.

99 GENERAL AND MISCELLANEOUS↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Limestone calcination with CO{sub 2} capture (III): characteristics of coal combustion during limestone decomposition

In this study, the combustion characteristics of coal in CO{sub 2}/O{sub 2} and steam/CO{sub 2}/O{sub 2} atmospheres were investigated during limestone decomposition in a continuously operating fluidized bed reactor for CO{sub 2} capture. The results show that the variations and concentrations of CO, CH{sub 4}, and H{sub 2} in the exhaust gas of the reactor in the steam/CO{sub 2}/O{sub 2} atmosphere were smaller than those in the CO{sub 2}/O{sub 2} atmosphere. Because of steam dilution, the CO{sub 2} concentration in the bed was lower in the steam/CO{sub 2}/O{sub 2} atmosphere than that in the CO{sub 2}/O{sub 2} atmosphere, and the effect of differential pressure variation on limestone decomposition in the fluidized bed was less pronounced in the steam/CO{sub 2}/O{sub 2} atmosphere than that in the CO{sub 2}/O{sub 2} atmosphere. Additionally, N{sub 2}O emission was detected only in the CO{sub 2}/O{sub 2} atmosphere, and the conversion of N to NO in the steam dilution atmosphere was of a smaller magnitude than that observed in the CO{sub 2}/O{sub 2} atmosphere. We also found that the conversion of S to SO{sub 2} in the steam/CO{sub 2}/O{sub 2} atmosphere was lower than that observed in the CO{sub 2}/O{sub 2} atmosphere. The contents of sulfur, SiO{sub 2}, and Al{sub 2}O{sub 3} were much higher in solid samples located in the cyclone than in the overflow holder in both steam/CO{sub 2}/O{sub 2} and CO{sub 2}/O{sub 2} atmospheres. Finally, the hydration and carbonation reactivities of CaO produced in the steam/CO{sub 2}/O{sub 2} atmosphere were better than those produced in the CO{sub 2}/O{sub 2} atmosphere. 13 refs., 14 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗