Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “argon-37”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Novel Methods to Produce an Argon-37 Standard

The purpose of this research was to produce a measurable quantity of radioactive argon-37 through photonuclear production methods. The detection of argon-37, above background levels, uniquely and clearly indicates the underground detonation of a nuclear device.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Methods to Produce an Argon-37 Standard

This poster describes details of a Laboratory Directed Research and Development project to produce and measure argon-37 for nuclear explosion detection.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Photonuclear Methods to Produce an Argon-37 Standard

The mission of this research is to explore novel photonuclear-based pathways into the production of 37Ar. Above-background detection levels of 37Ar uniquely indicates the occurrence of an underground nuclear explosion, produced from fission neutrons interacting in the surrounding environment through the 40Ca(n,a)37Ar reaction. The half-life of 35 days allows on-site inspectors (OSI) adequate time following the nuclear event to detect 37Ar and verify compliance or defiance of non-proliferation treaties such as the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An 37Ar standard would give OSI the ability to calibrate their detectors and measure detector efficiency allowing for the quantification of detected activity, give OSI authentic samples to test detectors in field exercises, and improve models predicting diffusion pathways of 37Ar through the underground environment.

43 PARTICLE ACCELERATORS↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a Low-Level Ar-37 Calibration Standard

Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiate powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

Absolute radiation measurement↗

Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty

On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,α)37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.

CTBT On-site Inspection↗

Subsurface Noble Gas Sampling Manual

The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

58 GEOSCIENCES↗

A New Shallow Underground Gas-Proportional Counting Lab - First Results and Ar-37 Sensitivity

Abstract A new ultra-low-background proportional counter was recently developed with an internal volume of 100 ml and has been characterized at pressures from 1-10 atmospheres with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 meters water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for Ar-37 has been calculated.

argon-37↗