Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “annual maintenance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cle Elum Supplementation and Research Facility : Monthly Progress Report : December 1, 2008 - December 31, 2008.

FISH PRODUCTION: Brood year 2008 production and experimental hatchery & supplemental crossed eggs continue to be incubated and chilled water at 380 Fahrenheit for the month. Temperature units are {approx}960 TU's at the end of the month. Hatching was observed at {approx}900 temperature units (TU's). The 2007 Brood year (BY) has approximately 773,477 juveniles on hand at the end of December, averaging 30.6 fish per pound. Fish tagging operations wrapped up on the 5th. Transportation of fish to acclimation sites is tentatively scheduled to begin January 12th. FISH CULTURE: Production pond cleaning continues on a weekly basis, and feeding continues to be performed two days per week due to the colder river water temperatures. Eggs in the incubation continue to be tempered in 38 degree water and temperature units recorded daily. On the 20th the river became too inclement for normal operations as the intake screens were covered with ice, at that time we shutdown two river pumps and turned on wells four and six to get 6,825 gallons of water. This was the operation at the facility for twenty-four hours at which point we were able to get back to normal operations. WATER PRODUCTION: The current combined well and river water supply to the complex is 14,756 gallons/min. The river pumps are supplying 13,571 gallons per minute. Well pumps No.2 and No.4 are operating and supplying 1,185 gallons/min. More on well pumps in the well field maintenance section of this report. ACCLIMATION SITES: Preparation of acclimation sites for fish transfer was the main focus for the month of December. Each week thermographs that record water temperature have the data disc changed at the acclimations sites. Ford Excavation with assistance from YKFP maintenance has started clearing snow out of the Easton acclimation site. VEHICLE MAINTENANCE: The snowmobiles were taken in to have annual maintenance performed. The full-size John Deere tractor needed and was taken to Barnet Implement in Yakima. The tractor needed a new clutch installed and was picked up on the 31st. SHOP BUILDING MAINTENANCE: On the 12th the facility domestic water hydro pneumatic tank and its system malfunctioned. The problem persisted and had to be dealt with multiple times; first it caused the tank to over flow and floods the shop. Wallace Electric was called and after extensive monitoring of the tank, compressor and electrical operations an electrical relay switch was replaced. Weekly cleaning and tool inventory continues to be a priority. The shop is home to our liberation truck along with fish transfer equipment, fish pump and seine nets. ELECTRICAL BUILDING MAINTENANCE: The large generator is located in the electrical building and is checked daily for routine inspections. HATCHERY BUILDING MAINTENANCE: The incubation building is being used to clean and repair isolation buckets, egg incubation baskets and troughs. An experiment involving remote site incubators (RSI's) continued through the month. Chad Stockton, WDFW, records flows and monitors emergence of fry on a daily basis. Chad is working with Steve S. and Curt K. on the RSI's research along with spawning channel fry emergence. RIVERWATER COOLING FACILITY: The one pump in operation in this building is checked daily during our routine inspections, the variable pump is supplying water to the artificial spawning channel. RIVER PUMP STATION MAINTENANCE: All four river pumps are in operation and pumping {approx}13,571 gallons/min to the facility. The building is cleaned monthly and the air burst system is cycled daily during the morning checks. The crew continued weekly changing of the graph paper on the river temperature thermograph throughout the month, continuing this activity as part of the daily checks routine. WELL FIELD MAINTENANCE: Wells No.1 and No.4 were in operation and supplying 1,185 gallons/minute to the facility and incubation building. Weekly test well readings are recorded and sent via fax to CH2MHILL. Also weekly well meter readings are recorded. Well No.5 had been determined to have a faulty drain valve while trying to operate the pump for emergency water usage. It was determined that water was not able to drain and began to flow out from the test hole (TH9). Charlie and Simon pumped out the remaining water from the test hole prior to replacing the valve. The valve was subsequently dug up, replaced and tested for operation. SAFETY AND TRAINING: The winter season has approached and conditions can be hazardous as Cle Elum staff stress safety while working and preparing acclimation sites for upcoming fish transfer. Some examples include wearing proper clothing, extra caution while driving and plowing snow. GROUNDS: Linda Lamebull of fisheries and personnel from Tribal Purchasing came to the hatchery to inventory two way radios.

13 HYDRO ENERGY↗

Effect of Power Plant Capacity on the CAPEX, OPEX, and LCOC of the CO2 Capture Process in Pre-Combustion Applications - Abstract

Aspen Plus v8.8 was used to simulate the pre-combustion CO2 capture process from a typical fuel gas stream at different power plant capacities ranging from 54.3 to 543 MW. Polyethylene glycol polydimethyl siloxane (PEGPDMS-1) was used as a physical solvent to capture CO2 in a countercurrent packed-bed absorber containing a structured packing (Mellapak 250Y). The process pressure was 51.4 bar and the solvent temperature was varied from 10 to 40 <sup>o</sup>C. The internal diameter of the absorber ranged from 1.9 to 7 m and the packing height from 13.9 to 45.5 m. The physico-chemical properties were obtained and modeled using the Perturbed Chain-Statistical Associating Fluid Theory (PC-SAFT) Equation-of-State (EOS).<p> Four process constraints were imposed in Aspen Plus: (1) no flooding in the absorber, (2) the absorber height to diameter ratio (H/D) is greater than or equal 6, (3) at least 90 mol% of the CO2 capture from the fuel gas stream, and (4) the CO2 stream destined to sequestration sites should contain less than 600 ppm water concentration and less than or equal 0.5 mol% of fuel gases (H2, CO, CH4). The plant lifetime was assumed to be 30 years with an annual discount rate of 10% and an annual maintenance cost of 4% of the total capital expenses.</p><p> Seven power plants with different capacities were used and for each plant, the corresponding CO2 capture process was simulated. The absorber flooding was checked using the generalized pressure drop correlation (GPDC) by Leva [1] and the capital expenditure (CAPEX), operating expenditure (OPEX), and levelized costs per ton of CO2 captured (LCOC) were calculated [2-5]. Normalized by the largest power plant capacity (543 MW) used in the simulation, the results indicated that the capital and operating expenditures increased, however, the LCOC decreased with increasing plant capacity. This behavior was due to the increased annual tonnage of the CO2 captured with plant capacity as shown in Figure 1. The calculated CAPEX, OPEX, LCOC and the tonnage of CO2 captured for the 543 MW power plant were about 52 MM$, 22 MM$/year, 7.46 $/ton and 4 MM ton/year.</p>

Ashkanani, Husain↗

Catalyst-Based Nonchemical Water Treatment System Frank E. Moss US Courthouse Salt Lake City, Utah

In 2012 and 2013, the US General Services Administration (GSA) and Oak Ridge National Laboratory conducted an evaluation of a novel nonchemical water treatment (NCWT) system at the Frank E. Moss US Courthouse in Salt Lake City, Utah. This system purports to use a proprietary metallic catalyst to change the water’s chemistry such that hard calcite does not form on surfaces that are in contact with the water. The catalyst-based NCWT system was installed on an electric domestic water heater in the courthouse. 1 This water heater had been experiencing severe calcite buildup on the heating elements. The calcite buildup impeded heat transfer from the heating elements into the domestic water, leading to the thermostat being set excessively high in an attempt to maintain the water temperature. This caused excess heat to build up on the elements, resulting in their premature failure which required frequent replacement. The buildup also required the elements to stay energized constantly to produce enough heat to maintain temperature in the domestic hot water system. After installing the catalyst-based NCWT system, calcite buildup was dramatically reduced and failure of the elements ceased. Labor and material savings from not having to replace the elements ($\$$1,060/year) allow for less than a two-year simple payback when compared to the installed cost of the system ($\$$1,692) plus minimal annual maintenance ($\$$100/year). The catalyst-based NCWT system should be considered for deployment in any heating system that is subject to calcification, including hydronic heating systems and boilers, condensing boilers, gas water heaters, and electric water heaters. Had the catalyst-based NCWT technology not been installed on the water heater, a conventional salt-based calcite prevention system would have provided the same prevention of calcite buildup. The budget installed cost of such a system would have been $\$$3,200 plus $\$$350/year in chemicals and $\$$1,500/year labor to service the chemicals. Comparing the conventional to the catalyst-based system, the latter has both a lower installed cost and annual operating cost. The original test plan was to install the technology on both the domestic water heating system and on the site’s cooling tower, which had faced calcite issues in its history. This tower has had a calcite buildup problem that is currently being addressed with a salt-based treatment system. The project’s timeline did not allow for installing a system and testing it on the tower during the initial phase of this project in 2012 and 2013. A preliminary economic analysis was performed to estimate the installed cost and potential savings on the cooling tower. If installed on the site’s cooling tower, the installed cost of the catalyst-based system would be more expensive than the salt-based system ($\$$32,380 vs. $\$$2,700 for the salt-based). However, the salt-based system requires $\$$900/year in chemicals and $\$$3,900/year in labor, neither of which is needed by the catalyst based system. This would give a simple payback of less than seven years using the technology on a cooling tower.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Wind Farm Recommendation Report

On April 21, 2011, an Idaho National Laboratory (INL) Land Use Committee meeting was convened to develop a wind farm recommendation for the Executive Council and a list of proposed actions for proceeding with the recommendation. In terms of land use, the INL Land Use Committee unanimously agrees that Site 6 is the preferred location of the alternatives presented for an INL wind farm. However, further studies and resolution to questions raised (stated in this report) by the INL Land Use Committee are needed for the preferred location. Studies include, but are not limited to, wind viability (6 months), bats (2 years), and the visual impact of the wind farm. In addition, cultural resource surveys and consultation (1 month) and the National Environmental Policy Act process (9 to 12 months) need to be completed. Furthermore, there is no documented evidence of developers expressing interest in constructing a small wind farm on INL, nor a specific list of expectations or concessions for which a developer might expect INL to cover the cost. To date, INL assumes the National Environmental Policy Act activities will be paid for by the Department of Energy and INL (the environmental assessment has only received partial funding). However, other concessions also may be expected by developers such as roads, fencing, power line installation, tie-ins to substations, annual maintenance, snow removal, access control, down-time, and remediation. These types of concessions have not been documented, as a request, from a developer and INL has not identified the short and long-term cost liabilities for such concessions should a developer expect INL to cover these costs. INL has not identified a go-no-go funding level or the priority this Wind Farm Project might have with respect to other nuclear-related projects, should the wind farm remain an unfunded mandate. The Land Use Committee recommends Legal be consulted to determine what, if any, liabilities exist with the Wind Farm Project and INL’s rights and responsibilities in regards to access to the wind farm once constructed. An expression of interest is expected to go out soon to developers. However, with the potential of 2 years of study remaining for Site 6, the expectation of obtaining meaningful interest from developers should be questioned.

99 GENERAL AND MISCELLANEOUS↗

Status report for aging studies of epdm o-ring material for the h1616 shipping package

This is an interim status report for tasks carried out per Task Technical Plan SRNL-STI-2011-00506. A series of tasks/experiments are being performed at the Savannah River National Laboratory to monitor the aging performance of ethylene propylene diene monomer (EPDM) Orings used in the H1616 shipping package. The data will support the technical basis to extend the annual maintenance of the EPDM O-rings in the H1616 shipping package and to predict the life of the seals at bounding service conditions.

99 GENERAL AND MISCELLANEOUS↗

Final Report for Aging Studies of EPDM O-Ring Material for the H1616 Shipping Package (U)

This is a final report for tasks carried out per Task Technical Plan SRNL-STI-2011-00506. A series of tasks/experiments were performed at the Savannah River National Laboratory (SRNL) to monitor the aging performance of ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package. The test data provide a technical basis to extend the annual maintenance of the EPDM O-rings in the H1616 shipping package to two years and to predict the life of the seals at bounding service conditions.

Stefek, T. M.↗

Aging Study Of EPDM O-Ring Material For The H1616 Shipping Package - Three Year Status

This is a 3-year status report for tasks carried out per Task Technical Plan SRNL-STI-2011-00506. A series of tasks/experiments were performed at the Savannah River National Laboratory (SRNL) to monitor the aging performance of ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package. The test data provide a technical basis to extend the annual maintenance of the H1616 shipping package to three years and to predict the life of the EPDM O-rings at the bounding service conditions.

42 ENGINEERING↗

Los Alamos County Battery Energy Storage System Use Review

The purpose of this study is to identify potential alternative uses for the LAC-owned BESS. One critical fact that must be considered in evaluating any profitable use of the BESS is the standby cost associated with keeping the NaS battery on-line, as it must be kept at 300 degrees Celsius at all times, regardless of whether it is being used or not. Standby for the NaS battery online requires approximately 80 MWh/month, costing approximately 28,000 dollars annually. Other relevant costs include a 22,000 dollar annual maintenance contract required for the NaS, and accounting for any losses due to inefficiencies during the operation of the battery. County operations personnel respond to all alarms and visit the BESS on a monthly basis to walk down the site. It estimated this cost approximately 10,000 dollars per year. The total cost of maintaining and keeping the NaS battery on-line for a year, then, is roughly 60,000 dollars.

25 ENERGY STORAGE↗

Demonstration of μCHP in Light Commercial Hot Water Applications

Internal combustion engine driven combined heat and power (CHP) systems produce power while the waste heat is recovered and used for another purpose. For µCHP systems (less than 50kWe output) overall efficiencies can reach over 90% for products currently on the market throughout the world. On a fuel basis this offers an advantage over using grid-based power and another fuel for heat. Additionally, the cost of natural gas on an energy unit basis is significantly less expensive than electric power. This difference can lead to substantial savings for the end user of a CHP system. In some parts of the world, particularly Germany and Japan, µCHP has become a common part of the heat and distributed generation equipment mix. Market analysis conducted in 2012 showed that in North America there is potential of a 5,300 units per year market for µCHP, resulting in an annual energy savings of approximately 13.5 TBtu and more than $84 million in annual customer savings. However, µCHP still has not seen much market penetration in North America. This study helps to identify some of the reasons why, address roadblocks that still need to be overcome and provide experience to established best practices. Nine commercial sites were initially identified (fitness club, surgical center, senior community, resort and spa, commercial laundry, two multi-family housing, restaurant and manufacturing facility). Systems from two different manufacturers were installed at five sites total, but due to unforeseen circumstances, only three of those sites were finally commissioned: test data were collected by Oak Ridge National Laboratory. While not all systems were installed as intended, the project resulted in the following key findings: Micro combined heat and power is an unfamiliar technology for building owners and plumbing and electrical contractors that serve the buildings most suited for µCHP. Manufacturers will need to be aggressive in providing training and providing broad support to successfully bring the technology to market.; The proper integration of µCHP into other building systems is the most critical part of a successful installation. Manufacturers will need to be able to provide the expertise to train, advise and support the mechanical contractors during the design and installation of the heat integration system.; Regulations governing µCHP varies across the country. There are a few UL standards (UL 2200 and UL 1741) that apply nationally. Emissions are governed by EPA except in California where the California Air Resources Board (CARB) has established their own standard. Requirements that dictate installation and interconnection are dependent on local building codes and local utility processes and requirements. Some out of date building codes do not offer clear guidance for these requirements, leading to confusion. This makes developing training and determining broadly applicable best practices difficult.; Installation costs of µCHP are a key factor in making an installation successful. It is critical that these costs and all national, state and local regulations be understood and accounted for by all parties involved in the installation before a project is undertaken.; A robust customer service organization is important to meet the needs of the customers. These systems require annual maintenance and service and local capability is needed to keep costs inline.

03 NATURAL GAS↗

Hydrogen for Maritime Applications

The maritime industry is investigating a number of fuel options for reducing emissions, including liquefied natural gas (LNG), biofuels, and electrical drive systems powered by batteries and/or hydrogen-fueled fuel cells. Hydrogen-fueled ships offer the potential to significantly reduce, if not eliminate, regulated and unregulated pollutants in maritime applications. Argonne National Laboratory conducted preliminary comparisons of the total cost of ownership (TCO) of several classes of ships to determine how fuel cell technology compares to the current diesel technology, what advancements are needed for hydrogen fuel cell technology to be competitive in the future, and what applications may be appropriate for introducing fuel cells into the maritime industry. These studies included feeder container ships, harbor tugboats, river pushboats, and auto/passenger ferries. For this study, TCO was defined to include the cost of fuel, propulsion system, and fuel storage system, the levelized cost of propulsion/auxiliary engines, and the cost of annual maintenance and consumables. It did not include the cost of the vessel frame or other components, aside from the propulsion system, that the fuel cell and diesel ships have in common. A 10% internal rate of return (IRR) was applied to the initial capital investment and an installation cost factor of 20% was applied to the capital cost. The capital cost of each component (e.g., engine, fuel tank, motor, etc.) was amortized over a period of 20 years, except for the fuel cell system, which was amortized over 6 or 10 years depending on ship class. The initial comparisons for container ships indicate that fuel costs are by far the dominant contributor to the TCO. With the current low cost of low-sulfur marine gasoil (LSMGO) and relatively high cost of hydrogen, it is difficult for hydrogen to compete with LSMGO in container ship applications. The large energy demand for container ships also favors the use of the higher volumetric energy density LSMGO fuel, especially for longer voyages. The space required to store enough hydrogen for the same journey is larger than that needed to store diesel fuels and can reduce the available cargo carrying and revenue generating space available on the ship.

08 HYDROGEN↗

Recertification of the DOE 9978 Type B Package: Lessons L

The history and limited use of the 9978 Type B package history represents a complex case story. Unprecedented delays (from Covid-19) caused the annual maintenance of nine loaded 9978 packages to expire before the actual shipments were initiated. Additionally, with the delays, the content amendment authorizing the Pu and Am standards as authorized content expired, hence additionally requiring a full SARP revision prior to making the shipments

Ketusky, Edward T. [Savannah River National Labora↗

Integrated Planning: Consolidating Annual Facility Planning - More Time for Execution

Previously, annual planning for Readiness in Technical Base and Facilities (RTBF) at the Nevada National Security Site (NNSS) was fragmented, disconnected, circular, and occurred constantly throughout the fiscal year (FY) comprising 9 of the 12 months, reducing the focus on implementation and execution. This required constant “looking back” instead of “looking forward.” In FY 2009, annual planning was consolidated into one comprehensive integrated plan (IP) for each facility/project, which comprised annual task planning/outyear budgeting, AMPs, and investment planning (i.e., TYIP). In FY 2010, the Risk Management Plans were added to the IPs. The integrated planning process achieved the following: 1) Eliminated fragmented, circular, planning and moved the plan to be more forward-looking; 2) Achieved a 90% reduction in schedule planning timeframe from 40 weeks (9 months) to 6 weeks; 3) Achieved an 80% reduction in cost from just under $1.0M to just over $200K, for a cost savings of nearly $800K (reduced combined effort from over 200 person-weeks to less than 40); 4) Reduced the number of plans generated from 21 plans (1 per facility per plan) per year to 8 plans per year (1 per facility plus 1 program-level IP); 5) Eliminated redundancy in common content between plans and improved consistency and overall quality; 6) Reduced the preparation time and cost of the FY 2010 SEP by 50% due to information provided in the IP; 7) Met the requirements for annual task planning, annual maintenance planning, ten-year investment planning, and risk management plans.

Nelson, J. G.↗

Aging Behavior of the EPDM O-Rings in the H1616 Shipping Package

The H1616 shipping package is used within the DOE complex for shipping tritium reservoirs. The annual recertification frequency can create logistical difficulties with other constraints on the timing of shipments; thus, a longer re-certification period is desirable. The ethylene propylene diene monomer (EPDM) O-rings used in the H1616 shipping package are being aged and tested at the Savannah River National Laboratory (SRNL) to provide a technical basis for extending the annual maintenance of the H1616 shipping package. H1616 EPDM O-rings are being aged at elevated temperature, and tested for degradation in mechanical properties, compression stress relaxation (CSR) behavior, and leak performance. Mechanical properties of aged O-rings show significant degradation can occur, but an inert atmosphere (argon backfill) greatly reduces the rate of degradation. The CSR behavior of O-rings was evaluated in air at 79 to 177 °C. These collective data were used to develop a predictive model for extrapolation of CSR behavior to relevant service temperatures (<67 °C). O-rings were also aged in H1616 Containment Vessels (CV) in an inert atmosphere at 71 to 149 °C. The vessels are helium leak tested periodically to determine if they continue to remain leak-tight. The vessel tests provide a solid demonstration that the H1616 O-rings will remain leak-tight at temperatures up to 113 °C for up to approximately 2.3 years. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in service. The predictive model developed from the CSR data conservatively indicates a service life of ~5 years at 67 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance. Based on the collective data developed to date, SRNL has recommended that the maintenance interval for the H1616 package be extended from 1 year to 2 years. Future recommendations in support of even longer maintenance intervals are expected, as additional aging data become available.

36 MATERIALS SCIENCE↗

Duck Valley Reservoirs Fish Stocking and Operation and Maintenance, 2005-2006 Annual Progress Report.

The Duck Valley Reservoirs Fish Stocking and Operations and Maintenance (DV Fisheries) project is an ongoing resident fish program designed to enhance both subsistence fishing, educational opportunities for Tribal members of the Shoshone-Paiute Tribes, and recreational fishing facilities for non-Tribal members. In addition to stocking rainbow trout (Oncorhynchus mykiss) in Mountain View, Lake Billy Shaw, and Sheep Creek Reservoirs, the program also intends to afford and maintain healthy aquatic conditions for fish growth and survival, to provide superior facilities with wilderness qualities to attract non-Tribal angler use, and to offer clear, consistent communication with the Tribal community about this project as well as outreach and education within the region and the local community. Tasks for this performance period are divided into operations and maintenance plus monitoring and evaluation. Operation and maintenance of the three reservoirs include fences, roads, dams and all reservoir structures, feeder canals, water troughs and stock ponds, educational signs, vehicles and equipment, and outhouses. Monitoring and evaluation activities included creel, gillnet, wildlife, and bird surveys, water quality and reservoir structures monitoring, native vegetation planting, photo point documentation, control of encroaching exotic vegetation, and community outreach and education. The three reservoirs are monitored in terms of water quality and fishery success. Sheep Creek Reservoir was the least productive as a result of high turbidity levels and constraining water quality parameters. Lake Billy Shaw trout were in poorer condition than in previous years potentially as a result of water quality or other factors. Mountain View Reservoir trout exhibit the best health of the three reservoirs and was the only reservoir to receive constant flows of water.

13 HYDRO ENERGY↗

Duck Valley Reservoirs Fish Stocking and Operation and Maintenance, 2006-2007 Annual Progress Report.

The Duck Valley Reservoirs Fish Stocking and Operations and Maintenance (DV Fisheries) project is an ongoing resident fish program that serves to partially mitigate the loss of anadromous fish that resulted from downstream construction of the hydropower system. The project's goals are to enhance subsistence fishing and educational opportunities for Tribal members of the Shoshone-Paiute Tribes and provide resident fishing opportunities for non-Tribal members. In addition to stocking rainbow trout (Oncorhynchus mykiss) in Mountain View, Lake Billy Shaw, and Sheep Creek Reservoirs, the program is also designed to maintain healthy aquatic conditions for fish growth and survival, to provide superior facilities with wilderness qualities to attract non-Tribal angler use, and to offer clear, consistent communication with the Tribal community about this project as well as outreach and education within the region and the local community. Tasks for this performance period are divided into operations and maintenance plus monitoring and evaluation. Operation and maintenance of the three reservoirs include fences, roads, dams and all reservoir structures, feeder canals, water troughs and stock ponds, educational signs, vehicles and equipment, and outhouses. Monitoring and evaluation activities included creel, gillnet, wildlife, and bird surveys, water quality and reservoir structures monitoring, native vegetation planting, photo point documentation, control of encroaching exotic vegetation, and community outreach and education. The three reservoirs are monitored in terms of water quality and fishery success. Sheep Creek Reservoir was very unproductive this year as a fishery. Fish morphometric and water quality data indicate that the turbidity is severely impacting trout survival. Lake Billy Shaw was very productive as a fishery and received good ratings from anglers. Mountain View was also productive and anglers reported a high number of quality sized fish. Water quality (specifically dissolved oxygen and temperature) is the main limiting factor in our fisheries.

13 HYDRO ENERGY↗