Engineering PapersSearch

SEARCH · Engineering Papers

Results for “annealed importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flow annealed importance sampling bootstrap meets differentiable particle physics

High-energy physics requires the generation of large numbers of simulated data samples from complex but analytically tractable distributions called matrix elements. Surrogate models, such as normalizing flows, are gaining popularity for this task due to their computational efficiency. We adopt an approach based on flow annealed importance sampling bootstrap (FAB) that evaluates the differentiable target density during training and helps avoid the costly generation of training data in advance. We show that FAB reaches higher sampling efficiency with fewer target evaluations in high dimensions in comparison to other methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Multi-fidelity is the new annealing: Gradient-free learning of posterior densities via transport maps

To tackle concentrated, multi-modal Bayesian inference problems, we propose using an annealed importance sampling procedure. To do this, we form a sequence of annealed distributions and employ transport maps to act as a surrogate of each distribution. This process is demonstrated on a few examples, favorably showing its potential for efficiently parallelizing the process of PDE evaluations and allowing for surrogates that we can sample from exactly.

van Bloemen Waanders, Bart G [Sandia National Labo

Effects of Melt Processing on Evolution of Structure in PEEK

We report on the effects of melt processing temperature on structure formation in Poly(ether-ether-ketone), PEEK. Real time Small Angle X-ray Scattering, SAXS, and thermal analysis are used to follow the melting behavior after various stages of processing. Assignment of peaks to structural entities within the material, the relative perfection of the crystals, and the possibility of their reorganization, are all influenced by the melt processing history. With the advent of high intensity synchrotron sources of X-radiation, polymer scientists gain a research tool which, when used along with thermal analysis, provides additional structural information about the crystals during growth and subsequent melting. PEEK is an engineering thermoplastic polymer with a very high glass transition temperature (145 C) and crystal melting point (337 C). PEEK has been the subject of recent studies by X-ray scattering in which melt and cold crystallization were followed in real-time. X-ray scattering and thermal studies have been used to address the formation of dual endothermic response which has been variously ascribed to lamellar insertion, dual crystal populations, or melting followed by re-crystallization. Another important issue is whether all of the amorphous phase is located in interlamellar regions, or alternatively whether some is located in "pockets" away from the crystalline lamellar stacks. The interpretation of scattering from lamellar stacks varies depending upon whether such amorphous pockets are formed. Some groups believe all of the amorphous phase is interlamellar. This leads to selection of a smaller thickness for the crystals. Other groups suggest that most amorphous phase is not interlamellar, and this leads to the suggestion that the crystal thickness is larger than the amorphous layer within the stacks. To investigate these ideas, we used SAXS and Differential Scanning Calorimetry to compare results of single and dual stage melt crystallization of PEEK using a treatment scheme involving annealing/crystallization at T(sub a1) followed by annealing at T(sub a2) where either T(sub a1) < T(sub a2) or T(sub a1) > T(sub a2). We proposed a model to explain multiple melting endotherms in PPS, treated according to one or two-stage melt or cold crystallization. Key features of this model are that multiple endotherms: (1) are due to reorganization/recrystallization after cold crystallization; and, (2) are dominated by crystal morphology after melt crystallization at high T. In other words, multiple distinct crystal populations are formed by the latter treatment, leading to observation of multiple melting. PEEK 45OG pellets (ICI Americas) were the starting material for this study. Films were compression molded at 400 C, then quenched to ice water. Samples were heated to 375 C in a Mettler FP80 hot stage and held for three min. to erase crystal seeds before cooling them to T(sub a1) = 280 C . Samples were held at T(sub a2) for a period of time, then immediately heated to 360 C. In the second treatment samples were held at T(sub a1) = 31 C for different crystallization times t(sub c) then cooled to 295 C and held 15 min. In situ (SAXS) experiments were performed at the Brookhaven National Synchrotron Light Source with the sample located inside the Mettler hot stage. The system was equipped with a two-dimensional position sensitive detector. The sample to detector distance was 172.7 cm and the X-ray wavelength was 1.54 Angstroms. SAXS data were taken continuously during the isothermal periods and during the heating to 360 C at 5 C/min. Each SAXS scan was collected for 30 sec. Since the samples were isotropic, circular integration was used to increase the signal to noise ratio. After dual stage melt crystallization with T(sub a1) < T(sub a2) the lower melting endotherm arises from holding at T(sub a1). During cooling a broad distribution of crystals forms, and the low-melting tail is perfected during T(sub al). Heating to T(sub a2) melts these imperfect crystals and allows others with greater average long spacing to form in their place. After dual stage crystallization with T(sub a1) > T(sub a2), the amount of space remaining for additional growth at T(sub a2) depends upon the holding time at T(sub a1). The long period of crystals formed at T(sub a2) is smaller than that formed at T(sub a1) due to growth in a now-restricted geometry. Perfection of crystals is seen as an increase of the intensity of the population scattering at higher s, while the intensity of the population scattering at lower s stays constant. During heating from below to above the minor endotherm, we see rapid decrease of the intensity of the X-ray scattering corresponding to the population of crystals scattering in the shoulder. Another important observation is that after the sample is annealed at 295 C, the shoulder intensity is restored once again. The population scattering at higher s remains longer before it disappears in the sample treated to the second stage of melt crystallization, compared to the sample crystallized with a single stage. This could be interpreted as an effect of continued perfection of the less perfect population, which is also reflected in the increased melting temperature of the smaller endotherm as the holding time at 295 C increases. In the corresponding DSC scans we see a shift in the area and the peak temperature of the lower melting endotherm with an increase of the annealing time.

Georgiev, Georgi

Mechanical properties and morphology of poly(etheretherKetone)

Mechanical properties and morphology of poly(etheretherketone) (PEEK) were studied for samples having different thermal histories. Isothermal and rate-dependent crystallization were studied to ascertain the relationship between crystallinity/morphology and processing condition. Degree of crystallinity and microstructure were controlled by cooling the melt at different rates, ranging from quenching to slowly cooling, and by annealing amorphous material above the glass transition temperature Tg. It is found that degree of crystallinity was not as important as processing history in determining the room temperature mechanical properties. Samples with the same degree of crystallinity had very different tensile properties, depending on rate of cooling from the melt. All samples yielded by shear band formation and necked down. Quenched films had the largest breaking strains, drawing to 270 percent. Slowly cooled films exhibited ductile failure at relatively low strains. Best combined mechanical properties were obtained from semicrystalline films cooled at intermediate rates from the melt.

Cebe, Peggy

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.

Role of washing solvents in defining the magnetic performance of Sm 2 Fe 17 N 3 obtained by reduction diffusion

Calciothermic reduction-diffusion (RD) is one of the leading synthesis methods for Sm 2 Fe 17 N 3 (SmFeN), but sintering of such RD-derived powders is hampered by oxidation and CaO byproducts. Here, we systematically evaluate how post-synthesis washing solvents govern powder chemistry and magnetic performance. RD-synthesized SmFeN powder was washed with several aqueous and non-aqueous solvents using identical washing protocols. This was followed by an assessment of both the as-washed powder as well as after annealing at 425 °C. Phase content was quantified by synchrotron PXRD and Rietveld refinement and SEM/EDS. The oxygen content of the powders was determined via inert gas fusion and the magnetization by DC magnetometry. While all aqueous-based solutions were able to remove CaO, the non-aqueous solutions were only effective with extended washing times. Prior to annealing, the crystalline phases and magnetic properties of the as-washed powders were largely the same regardless of washing solvent. However, differences emerge after annealing, where water-based washing markedly lowers the coercivity (H c ~3.8-4.3 kOe). In contrast, non-aqueous NH 4 Cl-methanol washing protocols were more effective in preserving coercivity (H c ~4.9-5.9 kOe). We attribute this to lower oxygen content in the non-aqueous samples (~9,400 ppm v ~6,400 ppm, respectively) which in turn reduced the formation of α-Fe during annealing. These results highlight the importance of solvent choice in washing RD-synthesized SmFeN and demonstrate that non-aqueous protocols, which better limit oxidation, outperform aqueous solvents despite the need for longer washing times.

36 MATERIALS SCIENCE

Improved Manufacturability and Throughput of Ultra- Transparent, Super-Insulating Aerogels

AeroShield Materials produces a novel silica aerogel material with exemplary thermal performance and unprecedented optical clarity, offering the potential for super-insulating fenestration and insulated glass to reduce thermal losses in the built environment by billions of dollars every year. One of the most significant challenges facing AeroShield today is the total amount of time that is required to produce large monolithic aerogel samples. This overall process can require as much as 144 hours total, which can significantly hinder scale-up to an economically viable product. The purpose of this Phase 1 research was to continue development of our novel aerogel manufacturing process to reduce material processing time by up to 10x, greatly improving product throughput and reducing cost. AeroShield’s manufacturing process can be divided into 4 major stages, each with their own distinct set of parameters and time requirements. Under this Phase 1 award, AeroShield was able to identify and optimize a number of these parameters, including molding materials, solvent rinse conditions, critical point drying time, and annealing conditions. AeroShield also performed thorough analyses on how these optimized parameters affected important final characteristics of the gels, including optical clarity, thermal conductivity, and dimensional stability. This campaign culminated in the production of laboratory scale aerogel samples using significantly lower process times of both 36 and 18 total hours, which represent Phase 1 Target and Stretch goals. In order to achieve widespread market adoption, monolithic sheets of the aerogel material must be made to industry-standard sizes (8’ x 12’) at a cost that provides 5-7 year or less breakeven energy savings for consumers (<$2 sq/ft). The work performed under this Phase 1 award shows that time and materials required to make aerogel samples, which make up a significant portion of their overall cost, can be greatly reduced without sacrificing quality. AeroShield plans to use these optimized processes to produce larger, product-relevant sized aerogels in order to achieve target final material costs.

Wilke, Kyle

The effect of anti-phase domain size on the ductility of a rapidly solidified Ni3Al-Cr alloy

Tensile tests on splat-quenched Ni3Al-Cr alloys showed a sharp decrease in ductility with long-time annealing. The growth of the initially very-fine-size anti-phase domains showed a tenuous correlation with ductility up to a critical size, where ductility was lost. The grain size was relatively unaffected by these annealing treatments, but the grain-boundary curvature decreased, implying less toughness. An important observation was that, for the longest annealing time, a chromium-rich precipitate formed, which the data indicate could be a boride. Miniaturized tensile tests were performed on samples which were all obtained from the same splat-quenched foil, and the various domain sizes were controlled by subsequent annealing treatments.

Carro, G.

A comparison of FeO-rich, porphyritic olivine chondrules in unequilibrated chondrites and experimental analogues

Experimentally produced analogues of porphyritic olivine (PO) chondrules in ordinary chondrites provide an important insight into chondrule formation processes. We have studied experimental samples with PO textures grown at three different cooling rates (2, 5 and 100 C/h), and samples that have been annealed at high temperatures (1000-1200 C) subsequent to cooling. These are compared with natural chondrules of similar composition and texture from the ordinary chondrites Semarkona (LL3.0) and ALH 81251 (LL3.3). Zoning properties of olivine grains indicate that the Semarkona chondrules cooled at comparable rates to the experiments. Zoning in olivine from chondrules in ALH 81251 is not consistent with cooling alone but indicates that the chondrules underwent an annealing process. Chromium loss from olivine is very rapid during annealing and calculated diffusion coefficients for Cr in olivine are very similar to those of Fe-Mg interdiffusion coefficients under the same conditions. Annealed experimental samples contain an aluminous, low-Ca pyroxene which forms by reaction of olivine and liquid. No similar reaction texture is observed in ALH 81251 chondrules, and this may be evidence that annealing of the natural samples took place at considerably lower temperatures than the experimental analogues. The study supports the model of chondrule formation in a cool nebula and metamorphism of partly equilibrated chondrites during reheating episodes on the chondrite parent bodies.

Jones, Rhian H.

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A Comparison of Techniques for Scheduling Fleets of Earth-Observing Satellites

Earth observing satellite (EOS) scheduling is a complex real-world domain representative of a broad class of over-subscription scheduling problems. Over-subscription problems are those where requests for a facility exceed its capacity. These problems arise in a wide variety of NASA and terrestrial domains and are .XI important class of scheduling problems because such facilities often represent large capital investments. We have run experiments comparing multiple variants of the genetic algorithm, hill climbing, simulated annealing, squeaky wheel optimization and iterated sampling on two variants of a realistically-sized model of the EOS scheduling problem. These are implemented as permutation-based methods; methods that search in the space of priority orderings of observation requests and evaluate each permutation by using it to drive a greedy scheduler. Simulated annealing performs best and random mutation operators outperform our squeaky (more intelligent) operator. Furthermore, taking smaller steps towards the end of the search improves performance.

Globus, Al

Xenon diffusion following ion implantation into feldspar - Dependence on implantation dose

The diffusion properties of xenon implanted into feldspar, a major mineral in meteorites and lunar samples, are investigated in light of the importance of xenon diffusion in the interpretation of early solar system chronologies and the retention time of solar-wind-implanted Xe. Known doses of Xe ions were implanted at an energy of 200 keV into single-crystal plagioclase targets, and depth profiles were measured by alpha particle backscattering before and after annealing for one hour at 900 or 1000 C. The fraction of Xe retained following annealing is found to be strongly dependent on implantation dose, being greatest at a dose of 3 x 10 to the 15th ions/sq cm and decreasing at higher and lower doses. Xe retention is also observed to be unaffected by two-step anneals, or by implantation with He or Ar. Three models of the dose-dependent diffusion properties are considered, including epitaxial crystal regrowth during annealing controlled by the extent of radiation damage, the creation of trapping sites by radiation damage, and the inhibition of recrystallization by Xe during annealing

Melcher, C. L.

Magnetic Anisotropy and Stress Dependent Epoxy Wetting in FeNi-based Metal Amorphous Nanocomposite

Recently developed FeNi-based metal amorphous nanocomposites (MANCs) used in high-speed motors (HSMs) exhibit reduced eddy current losses while maintaining good mechanical properties and glass-forming abilities. Magnetic anisotropy in (Fe 70 Ni 30 ) 80 Nb 4 B 14 Si 2 amorphous magnetic ribbon (AMR) in the as-cast state and upon conventional (T CA ) and strain (T SA ) annealing heat treatment is investigated. From ribbon samples in as-cast condition, quenched in stress from planar flow casting (PFC) induced as-cast curvature derived uniaxial magnetic anisotropy. Stress relief by conventional furnace annealing at T CA > 350 °C achieved isotropic properties in the bulk. Annealing about the primary crystallization temperature, T CA ~ 450 °C, resulted in the formation of both FCC and BCC nanocrystallites and evolution to isotropic bulk magnetic properties confirming the random anisotropy model. In samples strain annealed at T SA = 440 °C at various tensions, relatively large controlled induced uniaxial anisotropy is achieved. The largest magnetic anisotropy occurs in annealing under the stress of 250 MPa yielding an anisotropy field of 7.1 x 10 4 A/m. Surface anisotropy observed by MOKE differs from bulk anisotropy due to image contrast from closure domains. Epoxy coatings are important for improved bonding, mechanical properties, and resistivity in tape-wound MANC cores for HSMs. Using a sessile droplet method, the equilibrium contact angle of an epoxy droplet on a tensile stress annealed MANC exhibits stress dependent surface energies. Anisotropic wetting in FeNi-based MANC heat treated at T CA = 440 °C mimics surface magnetic anisotropy observed by MOKE.

soft magnetic materials

Classical combinatorial optimization scaling for random Ising models on 2D heavy-hex graphs

Motivated by near term quantum computing hardware limitations, combinatorial optimization problems that can be addressed by current quantum algorithms and noisy hardware with little or no overhead are used to probe capabilities of quantum algorithms such as the quantum approximate optimization algorithm. In this study, a specific class of near term quantum computing hardware defined combinatorial optimization problems, Ising models on heavy-hex graphs both with and without geometrically local cubic terms, are examined for their classical computational hardness via empirical computation time scaling quantification. Specifically the time-to-solution (TTS) metric using the classical heuristic simulated annealing is measured for finding optimal variable assignments (ground states), as well as the time required for the optimization software Gurobi to find an optimal variable assignment. Because of the sparsity of these Ising models, the classical algorithms are able to find optimal solutions efficiently even for large instances (i.e. 100 000 spin variables). The Ising models both with and without geometrically local cubic terms exhibit average-case linear-time or weakly quadratic scaling when solved exactly using Gurobi, and the Ising models with no cubic terms show evidence of exponential-time TTS scaling when sampled using simulated annealing. These findings point to the necessity of developing and testing more complex, namely more densely connected, optimization problems in order for quantum computing to ever have a practical advantage over classical computing. Our results are another illustration that different classical algorithms can indeed have exponentially different running times, thus making the identification of the best practical classical technique important in any quantum computing vs. classical computing comparison.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

The effects of space radiation on thin films of YBa2Cu3O(sub 7-x)

This investigation had two objectives: (1) to determine the effects of space radiation on superconductor parameters that are most important in space applications; and (2) to determine whether this effect can be simulated with Co-60 gamma rays, the standard test method for space materials. Thin films of yttrium barium copper oxide (YBCO) were formed by coevaporation of Y, BaF2, and Cu and post-annealing in wet oxygen at 850 C for 3.5 h. The substrate used was (100) silicon with an evaporated zirconia buffer layer. The samples were characterized by four point probe electrical measurements as a function of temperature. The parameters measured were the zero resistance transition temperature (T sub c) and the room temperature resistance. The samples were then exposed to Co-60 gamma-rays in air and in pure nitrogen, and to 780 keV electrons, in air. The parameters were then remeasured. The results are summarized. The results indicate little or no degradation in the parameters measured for samples exposed up to 10 Mrads of gamma-rays in nitrogen. However, complete degradation of samples exposed to 10-Mrad in air was observed. This degradation is preliminarily attributed to the high level of ozone generated in the chamber by the gamma-ray interaction with air. It can be concluded that: (1) the electron component of space radiation does not degrade the critical temperature of the YBCO films described, at least for energies around 800 keV and doses similar to those received by surface materials on spacecraft in typical remote sensing missions; and (2) for qualifying this and other superconducting materials against the space-radiation threat the standard test method in the aerospace industry, namely, exposure to Co-60 gamma-rays in air, may require some further investigation. As a minimum, the sample must be either in vacuum or in positive nitrogen pressure.

Herschitz, R.

The effects of space radiation on thin films of YBa2Cu3O(7-x)

This investigation had two objectives: (1) to determine the effects of space radiation on superconductor parameters that are most important in space applications; and (2) to determine whether this effect can be simulated with Co-60 gamma rays, the standard test method for space materials. Thin films of yttrium barium copper oxide (YBCO) were formed by coevaporation of Y, BaF2, and Cu and post-annealing in wet oxygen at 850 C for 3.5 h. The substrate used was (100) silicon with an evaporated zirconia buffer layer. The samples were characterized by four point probe electrical measurements as a function of temperature. The parameters measured were the zero resistance transition temperature T(sub c) and the room temperature resistance. The samples were then exposed to Co-60 gamma-rays in air and in pure nitrogen, and to 780 keV electrons, in air. The parameters were then remeasured. The results are summarized. The results indicate little or no degradation in the parameters measured for samples exposed up to 10 Mrads of gamma-rays in nitrogen. However, complete degradation is preliminarily attributed to the high level of ozone generated in the chamber by the gamma-ray interaction with air. It can be concluded that: (1) the electron component of space radiation does not degrade the critical temperature of the YBCO films described, at least for energies around 800 keV and doses similar to those received by surface materials on spacecraft in typical remote sensing missions; and (2) for qualifying this and other superconducting materials against the space-radiation threat the standard test method used in the aerospace industry, namely, exposure to Co-60 gamma-rays in air, may require some further investigation. As a minimum, the sample must be either in vacuum or in positive nitrogen pressure.

Herschitz, R.

Radiation effects on p+n InP junctions grown by MOCVD

The superior radiation resistance of InP over other solar cell materials such as Si or GaAs has prompted the development of InP cells for space applications. The early research on radiation effects in InP was performed by Yamaguchi and co-workers who showed that, in diffused p-InP junctions, radiation-induced defects were readily annealed both thermally and by injection, which was accompanied by significant cell recovery. More recent research efforts have been made using p-InP grown by metalorganic chemical vapor deposition (MOCVD). While similar deep level transient spectroscopy (DLTS) results were found for radiation induced defects in these cells and in diffused junctions, significant differences existed in the annealing characteristics. After injection annealing at room temperature, Yamaguchi noticed an almost complete recovery of the photovoltaic parameters, while the MOCVD samples showed only minimal annealing. In searching for an explanation of the different annealing behavior of diffused junctions and those grown by MOCVD, several possibilities have been considered. One possibility is the difference in the emitter structure. The diffused junctions have S-doped graded emitters with widths of approximately 0.3 micrometers, while the MOCVD emitters are often doped with Si and have widths of approximately 300A (0.03 micrometers). The difference in the emitter thickness can have important effects, e.g. a larger fraction of the total photocurrent is generated in the n-type material for thicker emitters. Therefore the properties of the n-InP material may explain the difference in the observed overall annealing behavior of the cells.

Messenger, Scott R.