Liquid propellant densification

Super cooling the cryogenic liquid propellant in a vehicle propellant tank densities the propellant allowing the vehicle propellant tank to carry more fuel in the same volume tank while lowering the vapor pressure and thus the tank operating pressure. Lowering the tank operating pressure reduces the stress and therefore allows the walls of the tank to be thinner. Both the smaller tank volume and thinner tank wall results in an overall smaller and lighter vehicle with increased payload capability. The cryogenic propellant can be supercooled well below the normal boiling point temperature level by transporting the liquid propellant from the vehicle tanks to a ground based cooling unit which utilizes a combination of heat exchanger and compressor. The compressor lowers the coolant fluid bath pressure resulting in a low temperature boiling liquid which is subsequently used to cool the recirculating liquid. The cooled propellant is then returned to the vehicle propellant tank. In addition to reducing the vehicle size and weight the invention also allows location of the vent valve on the ground, elimination of on-board recirculation pumps or bleed systems, smaller and lighter engine pumps and valves, lighter and more stable ullage gas, and significant reduction in tank fill operation. All of these mentioned attributes provide lower vehicle weight and cost.

Lak, Tibor I.

Wire-break Ignition Testing of Materials for Spacesuit Fire Hazard Control

The input design constraints applied to the extravehicular activity (EVA) spacesuit pose a significant challenge for mitigation of fire hazards. To minimize fatigue and increase comfort of the crewmember operating the suit, the suit pressure is lowered below sea level conditions with typical EVA suit designs operating with 4.3 psia (29.7 kPa). With the lowered operating pressures and the use of closed-loop life support, the suit requires elevated concentrations of oxygen, typically >95%. At these oxygen concentrations, nearly the entirety of the suit internal materials are flammable. This leaves one remaining possible control leg of the fire triangle: ignition sources. Since the Gemini and Apollo programs, this has been a risk that has undergone constant reassessment, with a focus on improved mitigation. After the Apollo I fire, an arc ignition method was developed and used to quantify ignition thresholds for in-suit materials resulting in a current limit for powered in-suit devices applied to all subsequent suit designs. After the discovery of a frayed spacesuit biomed cable on STS-113 during the Shuttle Program, the previous arcing method was repeated with additional methods developed to extend the testing further. One of those methods was wire-break ignition testing, in which the current in a single strand of wire was progressively increased, preheating the material in proximity with a resultant break and the application of a reasonably repeatable arc to ignite the material, all while exposed in the selected environment. This method was used to test a suite of spacesuit materials providing relative performance with respect to ignition with this configuration for application of energy. This paper discusses extension of the current data set to address recent material additions, lowering of energy test levels for quantification of materials too low to measure in previous testing, as well as future plans to improve this method.

Colin Campbell

Cyrogenic Life Support Technology Development Project

KSC has used cryogenic life support (liquid air based) technology successfully for many years to support spaceflight operations. This technology has many benefits unique to cryogenics when compared to traditional compressed gas systems: passive cooling, lighter, longer duration, and lower operating pressure. However, there are also several limiting factors that have prevented the technology from being commercialized. The National Institute of Occupational Safety and Health, Office of Mine Safety and Health Research (NIOSH-OMSHR) has partnered with NASA to develop a complete liquid air based life support solution for emergency mine escape and rescue. The project will develop and demonstrate various prototype devices and incorporate new technological innovations that have to date prevented commercialization.

compressed gas systems: passive cooling

In situ CF3 Detection in Low Pressure Inductive Discharges by Fourier Transform Infrared Spectroscopy

The detection of CF(x) (x=1-3) radicals in low pressure discharges using source gases such as CF4 and CHF3 is of importance to the understanding of their chemical structure and relevance in plasma based etching processes. These radicals are known to contribute to the formation of fluorocarbon polymer films, which affect the selectivity and anisotropy of etching. In this study, we present preliminary results of the quantitative measurement of trifluoromethyl radicals, CF3, in low pressure discharges. The discharge studied here is an inductively (transformer) coupled plasma (ICP) source in the GEC reference cell, operating on pure CF4 at pressures ranging from 10 - 100 mTorr, This plasma source generates higher electron number densities at lower operating pressures than obtainable with the parallel-plate capacitively coupled version of the GEC reference cell. Also, this expanded operating regime is more relevant to new generations of industrial plasma reactors being used by the microelectronics industry. Fourier transform infrared (FTIR) spectroscopy is employed to observe the absorption band of CF3 radicals in the electronic ground state X2Al in the region of 1233-1270/cm. The spectrometer is equipped with a high sensitivity HgCdTe (MCT) detector and has a fixed resolution of 0.125/cm. The CF3 concentrations are measured for a range of operating pressures and discharge power levels.

Kim, J. S.

Design of a variable area diffuser for a 15-inch Mach 6 open-jet tunnel

The Langley 15-inch Mach 6 High Temperature Tunnel was recently converted from a Mach 10 Hypersonic Flow Apparatus. This conversion was effected to improve the capability of testing in Mach 6 air at relatively high reservoir temperatures not previously possible at Langley. Elevated temperatures allow the matching of the Mach numbers, Reynolds numbers, and ratio of wall-to-adiabatic-wall temperatures (TW/Taw) between this and the Langley 20-inch Mach 6 CF4 Tunnel. This ratio is also matched for Langley's 31-inch Mach 10 Tunnel and is an important parameter useful in the simulation of slender bodies such as National Aerospace Plane (NASP) configurations currently being studied. Having established the nozzle's operating characteristics, the decision was made to install another test section to provide model injection capability. This test section is an open-jet type, with an injection system capable of injecting a model from retracted position to nozzle centerline between 0.5 and 2 seconds. Preliminary calibrations with the new test section resulted in Tunnel blockage. This blockage phenomenon was eliminated when the conical center body in the diffuser was replaced. The issue then, is to provide a new and more efficient variable area diffuser configuration with the capability to withstand testing of larger models without sending the Tunnel into an unstart condition. Use of the 1-dimensional steady flow equation with due regard to friction and heat transfer was employed to estimate the required area ratios (exit area / throat area) in a variable area diffuser. Correlations between diffuser exit Mach number and area ratios, relative to the stagnation pressure ratios and diffuser inlet Mach number were derived. From these correlations, one can set upper and lower operating pressures and temperatures for a given diffuser throat area. In addition, they will provide appropriate input conditions for the full 3-dimensional computational fluid dynamics (CFD) code for further simulation studies.

Loney, Norman W.

Role of central command in carotid baroreflex resetting in humans during static exercise

The purpose of the experiments was to examine the role of central command in the exercise-induced resetting of the carotid baroreflex. Eight subjects performed 30 % maximal voluntary contraction (MVC) static knee extension and flexion with manipulation of central command (CC) by patellar tendon vibration (PTV). The same subjects also performed static knee extension and flexion exercise without PTV at a force development that elicited the same ratings of perceived exertion (RPE) as those observed during exercise with PTV in order to assess involvement of the exercise pressor reflex. Carotid baroreflex (CBR) function curves were modelled from the heart rate (HR) and mean arterial pressure (MAP) responses to rapid changes in neck pressure and suction during steady state static exercise. Knee extension exercise with PTV (decreased CC activation) reset the CBR-HR and CBR-MAP to a lower operating pressure (P < 0.05) and knee flexion exercise with PTV (increased CC activation) reset the CBR-HR and CBR-MAP to a higher operating pressure (P < 0.05). Comparison between knee extension and flexion exercise at the same RPE with and without PTV found no difference in the resetting of the CBR-HR function curves (P > 0.05) suggesting the response was determined primarily by CC activation. However, the CBR-MAP function curves were reset to operating pressures determined by both exercise pressor reflex (EPR) and central command activation. Thus the physiological response to exercise requires CC activation to reset the carotid-cardiac reflex but requires either CC or EPR to reset the carotid-vasomotor reflex.

Non-NASA Center

Membrane Separation of Gases From The Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.

Membrane Separation of Gases from the Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of: (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.

A novel negative-limited sealed nickel-cadmium cell

The use of negative-limited nickel-cadmium cells with adequate charge control is shown to provide an effective means for controlling internal pressure. Cycle test data show that negative-limited cells have somewhat higher ampere-hour degradation rates at higher operating temperatures. The most important advantages of these cells are: (1) lesser heat generation during operation; (2) longer separator life, as a result of operation at lower temperatures; (3) decreased stresses on cell seals due to lower operating pressures; and (4) significant weight savings.

Juvinall, G. L.

Research Activities at Plasma Research Laboratory at NASA Ames Research Center

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies are being developed at NASA-Ames Research Center using a multi-discipline approach. The first step is to understand the basic physics of the chemical reactions in the area of plasma reactors and processes. Low pressure glow discharges are indispensable in the fabrication of microelectronic circuits. These plasmas are used to deposit materials and also etch fine features in device fabrication. However, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Although a great deal of laboratory-scale research has been performed on many of these processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. Our present research involves the study of such plasmas. An inductively-coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics. This ICP source generates plasmas with higher electron densities and lower operating pressures than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The research goal is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas phase and surface reaction rates, species concentration, temperature, ion energy distribution, and electron number density.

Sharma, S. P.

Diagnostic for Plasma Enhanced Chemical Vapor Deposition and Etch Systems

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies ion the processing of semiconductor materials arising from understanding etch chemistries are being developed through a research collaboration between Stanford University and NASA-Ames Research Center, Although a great deal of laboratory-scale research has been performed on many of materials processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. In addition, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. The research described involves the study of plasmas used in semiconductor processes. An inductively coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics and chemistries. This ICP source generates plasmas with higher electron densities (approximately 10(exp 12)/cu cm) and lower operating pressures (approximately 7 mTorr) than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The motivation for this study is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas-phase and surface reaction rates. species concentration, temperature, ion energy distribution, and electron number density. A wide variety of diagnostic techniques are under development through this consortium grant to measure these parameters. including molecular beam mass spectrometry (MBMS). Fourier transform infrared (FTIR) spectroscopy, broadband ultraviolet (UV) absorption spectroscopy, a compensated Langmuir probe. Additional diagnostics. Such as microwave interferometry and microwave absorption for measurements of plasma density and radical concentrations are also planned.

Cappelli, Mark A.

Recent Advances in Synthesis and Characterization of SWCNTs Produced by Laser Oven Process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics. Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. In-situ diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Aepalli, Sivaram

Recent Advances in Synthesis and Characterization of SWCNTs produced by laser oven process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics (ref. 1). Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. Insitu diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Arepalli, Sivaram

Design considerations for future planetary space suits

Manned extravehicular activity (EVA) operations will be major mission elements of planned future U.S. space operations. Whether designed for orbital operations or planetary surface exploration, the EVA system must be safe and reliable, and must provide a high degree of performance capabilities. An extravehicular mobility unit (EMU) consisting of a space suit, EVA gloves, and a portable life support system (PLSS) is central to the EVA system. A rugged, highly reliable, mobile, reusable, and easily maintained EVA suit and compact PLSS must meet the specific requirements of the intended mission. Additional requirements imposed by exposure to surface and gravitational environments are the need for lightweight, high-strength materials for fabricating EMUs to prevent astronaut fatigue and the need for dust protection measures and removal techniques to prevent contamination. Also, operational pressure for habitats should be chosen so as to maintain zero-prebreathe conditions while allowing for lower EMU operating pressure.

Kosmo, Joseph J.

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Iodine Propellant Feed System Flow Modeling

The use of solid iodine as a propellant in Hall-effect thrusters (HETs) is currently being investigated for small-satellite applications. CubeSats offer an inexpensive mode of access to space; however, they currently lack significant propulsion capability. A high specific impulse (I (sub sp)) propulsion system would permit a significant change in velocity, delta v, to be imparted for orbital maintenance, transfers, or de-orbit maneuvers. An electric propulsion system that uses iodine as a propellant has a number of advantages. It has an exceptionally high rho times I (sub sp) figure of merit (density multiplied by the specific impulse), meaning that it can achieve a large total delta v with a relatively low combination of propellant mass and propellant tank volume. Also, the propellant feed system operates at low pressures (a few psia at most), as opposed to the use of super-critical xenon stored at very high pressure. Low pressure operation can lower system mass while greatly reducing the risk of propellant tank rupture, making low pressure a vitally important property for propellants on secondary payloads like CubeSats, where risks must be minimized. The iSAT mission aims to demonstrate iodine-fed HET technology, flying it in space onboard a 12U 912-unit) CubeSat. In the iSAT propellant feed system (PFS), solid iodine is sublimed through heating to produce gaseous propellant that is conducted through tubing to the thruster and cathode. The sublimation process is governed by the iodine (I2) vapor pressure, which is shown as a function of temperature in figure 1. As gaseous I2 flows out of the tank, the gas pressure in the volume containing the solid iodine propellant is reduced until a balance between the flow of iodine out of the tank and the sublimation rate of solid iodine at the equilibrium gas pressure and chosen tank temperature is reached.

Martin, A. K.

Effect of Reactant Pressure on Proton Exchange Membrane Fuel Cell Performance

It is an objective of the National Aeronautics and Space Administration (NASA) to return to the moon and to create sustained lunar operations. Since many applicable lander and upper stage vehicles utilize cryogenic hydrogen and oxygen propellants, it is appealing to incorporate fuel cells into potential mission concepts. A fuel cell could generate electricity, heat, and water from the residual hydrogen and oxygen propellants. Such a concept depends on the capability of the fuel cell to utilize dry, propellant-grade reactants at reduced pressures compared to typical fuel cell operating conditions. This report describes a NASA evaluation of two passive water removal, non-flow-through proton exchange membrane (PEM) fuel cells: a twelve-cell 50 sq. cm active area stack and a seven-cell 150 sq. cm active area stack. Both stacks operated on research grade hydrogen and oxygen reactants supplied at pressures ranging from 20 psia up to the 45-48 psia design operating point, reliably supporting current densities of at least 450 mA/sq. cm at reduced pressures. Polarization curves, fitted with a semi-empirical equation for overpotential, show an increase in effective ohmic resistance and decrease in reversible cell potential, hydrogen crossover current, and Tafel slope when operating at lower pressures, resulting in a reduction in cell voltage at all current densities. Fitted parameters are compared to published values and rationalized with first principles explanations.

fuel cells

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION