Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer

Equivalent System Mass Comparison of ECLSS CO2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO2 Scrubber (4BCO2), CO2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO2 technologies best suited for a specific vehicle or mission.

Madeleine C Oliver

Equivalent System Mass Comparison of ECLSS CO 2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO 2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO 2 Scrubber (4BCO2), CO 2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO 2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO 2 technologies best suited for a specific vehicle or mission.

Madeleine Oliver

Behaviors of Lunar Regolith Simulant Under Varying Gravitational Conditions

Understanding the behavior of regolith in varying gravity conditions is critical for space exploration and future missions. In this work, the gravity-driven hopper flow of lunar regolith simulant in different gravitational accelerations (terrestrial, lunar) is first observed experimentally. Numerical simulations (DEM) are then developed to understand the role which cohesive inter-particle forces play in such gravity-driven flow, using the theoretical framework of granular Bond number. Qualitative comparison between a terrestrial experiment and numerical simulation validated this framework. Following that, we numerically studied the dynamic behavior under varying gravitational conditions (from terrestrial to lunar to asteroid gravitational accelerations). We find that this behavior is extremely sensitive to the interplay of the gravity conditions and the attractive/cohesive forces among particles. The numerical and experimental results show that the complex interaction of these forces can drastically change the dynamics of the material producing effects relevant for variable gravity applications.

Soft Matter

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch