Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alignment interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Graphene-Based Quantum Hall Interferometer with Self-Aligned Side Gates

The vanishing band gap of graphene has long presented challenges for fabricating high-quality quantum point contacts (QPCs)–the partially transparent p-n interfaces introduced by conventional split-gates tend to short the QPC. This complication has hindered the fabrication of graphene quantum Hall Fabry-P'erot interferometers, until recent advances have allowed split-gate QPCs to operate utilizing the highly resistive ν = 0 state. Here, we present a simple recipe to fabricate QPCs by etching a narrow trench in the graphene sheet to separate the conducting channel from self-aligned graphene side gates. Finally, we demonstrate operation of the individual QPCs in the quantum Hall regime, and further utilize these QPCs to create and study a quantum Hall interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Two-dimensional second harmonic dispersion interferometer

An interferometer having a fundamental beam generator, a first second harmonic generator, a waveplate, a second second harmonic generator, a harmonic separator, and a polarizing beam splitter, mounted uniaxially, (i.e., the components are aligned along one optical axis), wherein the interferometer is adapted to change a diameter of a beam to match a diameter of a sample, and to change the diameter of the beam back to its original diameter.

Wessel, Frank Joseph↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Two-dimensional phase cartography for high-harmonic spectroscopy

Extremely nonlinear spectroscopy based on high-order-harmonic generation has become a powerful investigation method for attosecond dynamics in gas and solid targets. In particular, the phase of harmonic emission was shown to carry profound insight into atomic and molecular structure and dynamics. However, current techniques offer phase measurements only along specific directions, thus providing partial characterization. Here we report on a new approach combining optical and quantum interferometers measuring along two dimensions the intensity and phase of harmonic emission from aligned molecules in the exact same experimental conditions. This two-dimensional cartography technique measures the phase with no arbitrary offset and no uncertainty on its sign. Measurements along different dimensions can be combined in two ways: either a single mapping or a redundant mapping allowing high-precision phase recovery using a Shack–Hartmann-like algorithm. We demonstrate both methods in a nitrogen test case, which allows disentangling structural and dynamical effects. Two-dimensional phase cartography paves the way to high-resolution high-harmonic spectroscopy for applications such as quantum orbital tomography and attosecond charge migration in molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

Best estimate of the planetary boundary layer height from multiple remote sensing measurements

Remote sensing measurements have been widely used to estimate the planetary boundary layer height (PBLHT). Each remote sensing approach offers unique strengths and faces different limitations. In this study, we use machine learning (ML) methods to produce a best-estimate PBLHT (PBLHT-BE-ML) by integrating four PBLHT estimates derived from remote sensing measurements at the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory. Three ML models – random forest (RF) classifier, RF regressor, and light gradient-boosting machine (LightGBM) – were trained on a dataset from 2017 to 2023 that included radiosonde, various remote sensing PBLHT estimates, and atmospheric meteorological conditions. Evaluations indicated that PBLHT-BE-ML from all three models improved alignment with the PBLHT derived from radiosonde data (PBLHT-SONDE), with LightGBM demonstrating the highest accuracy under both stable and unstable boundary layer conditions. Feature analysis revealed that the most influential input features at the SGP site were the PBLHT estimates derived from (a) potential temperature profiles retrieved using Raman lidar (RL) and atmospheric emitted radiance interferometer (AERI) measurements (PBLHT-THERMO), (b) vertical velocity variance profiles from Doppler lidar (PBLHT-DL), and (c) aerosol backscatter profiles from micropulse lidar (PBLHT-MPL). The trained models were then used to predict PBLHT-BE-ML at a temporal resolution of 10 min, effectively capturing the diurnal evolution of PBLHT and its significant seasonal variations, with the largest diurnal variation observed over summer at the SGP site. We applied these trained models to data from the ARM Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) field campaign (EPC), where the PBLHT-BE-ML, particularly with the LightGBM model, demonstrated improved accuracy against PBLHT-SONDE. Analyses of model performance at both the SGP and EPC sites suggest that expanding the training dataset to include various surface types, such as ocean and ice-covered areas, could further enhance ML model performance for PBLHT estimation across varied geographic regions.

Zhang, Damao [Pacific Northwest National Laborator↗

Automated tuning of a ring-assisted MZI-based interleaver for Kerr frequency combs

We demonstrate a compact ring-assisted Mach–Zehnder interferometer (RAMZI)-based silicon photonic interleaver with a 400 GHz free spectral range (FSR), featuring flat passbands exceeding a spectral range of 50 nm. Additionally, we introduce a novel, to the best of our knowledge, add-on structure and tuning method enabling automated compensation for fabrication imperfections, precise shaping of the RAMZI flat-top passbands, and alignment with Kerr comb lines. Experimental results have shown successful interleaving of eight channels of distributed-feedback (DFB) lasers as well as a 200 GHz Kerr comb, both achieving an extinction ratio of approximately 20 dB.

Wang, Songli (ORCID:0009000626380795)↗

Monolithic Spatial Heterodyne Raman Spectrometers (mSHRS): Toward highly miniature chemical sensors for deployment on moving platforms (Final Report, Phase I)

This report covers phase 1 (year 1) of the mSHRS project. Our ultimate long-term goal is to develop highly miniature Raman analyzers, known as spatial heterodyne Raman spectrometers (SHRS), that are deployable as in-situ chemical sensors on moving platforms. During Phase I (FY19/20) funding, our team focused our efforts solely on the key innovation needed toward realizing that goal: the development of the monolithic interferometer comprising the beam splitter and gratings with the appropriate design parameters and tolerances to enable Raman interferometry. We successfully developed and characterized the performance of the first monolithic SHRS devices including a monolithic version that incorporates field-widened optics. Our solid-state design approach integrated all optical components as a single monolithic unit for maintaining precise optical alignment during sensor operation, a requirement for operating in a vibration prone environment. This project has two principle activities: (1) Design and fabricate monolithic SHRS devices (i.e. monolithic device task) and (2) characterize the mSHRS devices in terms of performance (i.e. the Monolithic SHRS characterization task).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D radiation, density, and MHD structures following neon shattered pellet injection into stable DIII-D Super H-mode discharges

Six nominally repeat neon shattered pellet injection (SPI) shutdowns of stable DIII-D Super H-modes are studied to understand the 3D properties of the radiation and impurity transport. The radiation efficiency and radiation peaking determine whether first wall melting is expected following disruption mitigation in ITER. Previous studies make use of axisymmetric approximations to infer radiation efficiencies, but validating the high efficiency required by ITER necessitates improved accuracy, and this work contributes by exploring the 3D radiation and density structures that will inform forward modeling. When the neon shatter plume produced by the SPI reaches the plasma edge, m/n = 3/1 and 2/1 island O-points are observed to align with the injection trajectory in five out of six cases, suggesting that the injected material seeds the island O-points. Field aligned neon structures emitting Ne-I line radiation drift at 1 km/s in the ion diamagnetic drift direction during the pre-TQ, tracking the motion of the m/n = 2/1 island O-point. Neon fragments penetrate to the q = 2 surface by the time of the TQ. Techniques to constrain the 3D emissivity are explored, and one method constrains a 3D flux tube that is consistent with the radiation data, and when mapped to the interferometers, intersects the lasers that measure the highest density. The resulting structure derived from the radiation measurements exists near the 2/1 island X-point. In five repeatable discharges, the peak of the radiation in the toroidal direction exists in a 120° toroidal sector where the injection occurs, in contrast with the outlier discharge where the toroidal peak exists in the complementary 240° toroidal sector far from the injector, and where a 50% lower density rise is observed. In conclusion, the n = 1 phase behavior is markedly different in the outlier discharge, suggesting a possible dependence of the radiation structure and the assimilation efficiency on MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Ammonia in northeast Colorado is increasing, rising most quickly in regions close to confined animal feeding operations

The Colorado Front Range urban corridor and nearby agricultural operations are important source regions of atmospheric ammonia (NH 3 ). Upslope flows periodically transport these emissions into Rocky Mountain National Park (RMNP), located 50 km west of the urban corridor, where wet and dry deposition of excess reactive nitrogen (N) impacts ecosystems. Here, we use a combination of in situ passive NH 3 measurements and NH 3 vertical column density retrievals from the Infrared Atmospheric Sounding Interferometer (IASI) to assess variability and changes in NH 3 across three land use categories in the northeast Colorado source region (agricultural, urban, and remote) during the period 2013-2023. A strong seasonal cycle is present across the region with increased NH 3 during summer months. Elevated NH 3 is spatially correlated with the number of permitted animal units in confined animal feeding operations (CAFOs) within 12 km. Ground-level NH 3 concentrations are strongly positively correlated with monthly gridded IASI satellite column densities. Satellite retrievals reveal an increasing trend in NH 3 column amounts of ∼3% per year in agricultural and ∼2% per year in urban sub-regions. The magnitude of the trend observed in NH 3 columns averaged over the agricultural sub-region is > 3 times larger than observed near and over Denver. The largest increases in NH 3 are closely aligned with the distribution of CAFOs. Reductions in particle sulfate associated with declining sulfur dioxide (SO 2 ) emissions could account for only ∼0.1% per year increase in gaseous NH 3 . Wildfire smoke across the region has increased but appears unlikely to explain the majority of the observed NH 3 increase.

54 ENVIRONMENTAL SCIENCES↗