Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “active plasma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnosing Field Strengths and Plasma Conditions in Magnetically Insulated Transmission Lines Using Active Dopant Spectroscopy

Experimental validation data is needed to inform simulations of large pulsed power devices which are in development to understand and improve existing accelerators and inform future pulsed power capabilities. Using current spectroscopic techniques on the Z-machine, we have been unable to reliably diagnose plasma conditions and electric and magnetic fields within power flow regions. Laser ablation of a material produces a low density plasma, resulting in narrow spectroscopic line widths. By introducing a laser ablated plasma to the anode cathode gap of the Mykonos accelerator, we can monitor how the line shapes change due the current pulse by comparing these line shapes to spectral measurements taken without power flow. In this report we show several examples of measurements conducted on Mykonos on various dopant materials. We also show a negligible effect on power flow due to the presence of the ablation plasma for a range of parameters.

43 PARTICLE ACCELERATORS↗

Observation and Characterization of Vibrationally Active Surface Species Accessed with Nonthermal Nitrogen Plasmas

Polycrystalline Ni, Pd, Cu, Ag, and Au foils exposed to nonthermal plasma (NTP)-activated N 2 are found to exhibit a vibrational feature near 2200 cm –1 in polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS) observations that are not present in the same materials exposed to N 2 under nonplasma conditions. The feature is similar to that reported elsewhere and is typically assigned to chemisorbed N 2 . We employ a combination of temperature-dependent experiments, sequential dosing, X-ray photoelectron spectroscopy, isotopic labeling, and density functional theory calculations to characterize the feature. Results are most consistent with a triatomic species, likely NCO, with the C and O likely originating from ppm-level impurities in the ultrahigh-purity (UHP) Ar and/or N 2 gas cylinders. Here, this work highlights the potential for nonthermal plasmas to access adsorbates inaccessible thermally as well as the potential contributions of ppm-level impurities to corrupt the interpretation of plasma catalytic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes↗

Elemental profiling and genome-wide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

The ionome represents elemental composition in plant tissues and can be an indicator of nutrient status as well as overall plant performance. Thus, identifying genetic determinants governing elemental uptake and storage is an important goal for breeding and engineering biomass feedstocks with improved performance. In this study, we coupled high-throughput ionome characterization of leaf tissues with high-resolution genome-wide association studies (GWAS) to uncover genetic loci that modulate ionomic composition in leaves of poplar ( Populus trichocarpa ). Significant agreement was observed across the three ionomic profiling platforms tested: inductively coupled plasma-mass spectrometry (ICP-MS), neutron activation analysis (NAA) and laser-induced breakdown spectroscopy (LIBS). Relative quantification of 20 elements using ICP-MS across a population of 584 genotypes, revealed larger variation in micro-nutrients and trace elements content than for macro-nutrients across genotypes. The GWAS performed using a set of high-density (>8.2 million) single nucleotide polymorphisms, identified over 600 loci significantly associated with variations in these mineral elements, pointing to numerous uncharacterized candidate genes. A significant enrichment for genes related to ion homeostasis and transport was observed, including several members of the cation-proton antiporters (CPA) family and MATE efflux transporters, previously reported to be critical for plant growth and fitness in other species. Our results also included a polymorphic copy of the high-affinity molybdenum transporter MOT1 found directly associated to molybdenum content. For the first time in a perennial plant, our results provide evidence of genetic control of mineral content in a model tree species.

59 BASIC BIOLOGICAL SCIENCES↗

Atomically Dispersed Copper Sites in a Metal–Organic Framework for Reduction of Nitrogen Dioxide

Metal-organic framework (MOF) materials provide an excellent platform to fabricate single-atom catalysts due to their structural diversity, intrinsic porosity, and designable functionality. However, the unambiguous identification of atomically dispersed metal sites and the elucidation of their role in catalysis are challenging due to limited methods of characterization and lack of direct structural information. Here, we report a comprehensive investigation of the structure and the role of atomically dispersed copper sites in UiO-66 for the catalytic reduction of NO 2 at ambient temperature. The atomic dispersion of copper sites on UiO-66 is confirmed by high-angle annular dark-field scanning transmission electron microscopy, electron paramagnetic resonance spectroscopy, and inelastic neutron scattering, and their location is identified by neutron powder diffraction and solid-state nuclear magnetic resonance spectroscopy. The Cu/UiO-66 catalyst exhibits superior catalytic performance for the reduction of NO 2 at 25 °C without the use of reductants. A selectivity of 88% for the formation of N2 at a 97% conversion of NO 2 with a lifetime of >50 h and an unprecedented turnover frequency of 6.1 h-1 is achieved under nonthermal plasma activation. In situ and operando infrared, solid-state NMR, and EPR spectroscopy reveal the critical role of copper sites in the adsorption and activation of NO 2 molecules, with the formation of {Cu(I)···NO} and {Cu···NO 2 } adducts promoting the conversion of NO 2 to N 2 . This study will inspire the further design and study of new efficient single-atom catalysts for NO 2 abatement via detailed unravelling of their role in catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Ni catalyst activation during plasma-assisted methane oxidation

Atmospheric pressure plasma has shown promise in improving thermally activated catalytic reactions through a process termed plasma-catalysis synergy. In this work, we investigated atmospheric pressure plasma jet (APPJ)-assisted CH 4 oxidation over a Ni/SiO 2 .Al 2 O 3 catalyst. Downstream gas-phase products from CH 4 conversion were quantified by Fourier transform infrared spectroscopy. The catalyst near-surface region was characterized by in-situ diffuse reflectance infrared Fourier transform spectroscopy. The catalyst was observed to be activated at elevated temperature (500 °C) if it was exposed to the APPJ operated at large plasma power. 'Catalyst activation' signifies that the purely thermal conversion of CH 4 using catalysts which had been pre-exposed to plasma became more intense and produced consistently CO product, even if the plasma was extinguished. Without the application of the APPJ to the Ni catalyst surface this was not observed at 500 °C. The study of different exposure conditions of the activated catalyst indicates that the reduction of the catalyst by the APPJ is likely the cause of the catalyst activation. We also observed a systematic shift of the vibrational frequency of adsorbed CO on Ni catalyst when plasma operating conditions and catalyst temperatures were varied and discussed possible explanations for the observed changes. Furthermore, this work provides insights into the plasma-catalyst interaction, especially catalyst modification in the plasma catalysis process, and potentially demonstrates the possibility of utilizing the surface CO as a local probe to understand the plasma-catalyst interaction and shed light on the complexity of plasma catalysis.

methane oxidation↗

Real time detection of multiple stable MHD eigenmode growth rates towards kink/tearing modes avoidance in DIII-D tokamak plasmas

Abstract Real time detection of time evolving growth rates of multiple stable magnetohydrodynamic (MHD) eigenmodes has been achieved in DIII-D tokamak experiments via multi-mode three-dimensional (3D) active MHD spectroscopy. The measured evolution of the multi-modes’ growth rates is in good accordance with the variation of the plasma β N . Using experimental equilibria, resistive MARS-F simulations found the two least stable modes to have comparable growth rates to those experimentally measured. Real time and offline calculations of the modes’ growth rates show comparable results and indicate that cleaner system input and output signals will improve the accuracy of the real time stability detection. Moreover, the shortest real time updating time window of multi-mode eigenvalues can be about 2 ms in DIII-D experiments. This real time monitoring of stable, macroscopic kink and tearing modes thus provides an effective tool for avoidance of the most common causes of tokamak disruption.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Examining Metal Identity and Proximity Effects on Acetylene Hydrogenation with Azolate-Based MOFs

Liquid organic hydrogen carriers (LOHCs) are an attractive fuel source due to their compatibility with existing transportation methods and ease of use. However, they suffer from sluggish (de)hydrogenation kinetics. One promising platform for developing next-generation catalysts is metal–organic frameworks (MOFs), which can enable systematic interrogation into the influence of metal identity and spatial arrangement. In this study, the effect of the coordination environment was investigated using Ni- and Co-based azolate MOFs: MFU-4l-OH (M x Zn 5–x (OH) 4 (BTDD) 3 ; x = 4 for M = Co and x = 3 for M = Ni, H 2 BTDD = bis(1H-1,2,3-triazolo[4,5-b][4′,5′-i])dibenzo[1,4]dioxin), composed of single-site nodes, and M(OH) 2 BBTA (M = Ni, Co; H 2 BBTA = 1H,5H-benzo(1,2-d:4,5-d’)bistriazole), composed of extended chain-type nodes. The catalysts were characterized by isotherms, powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), inductively coupled plasma-optical emission spectroscopy (ICP-OES), and X-ray photoelectron spectroscopy (XPS) analysis. Acetylene hydrogenation activity under steady state conditions (150 °C, 1:1 C 2 H 2 :H 2 ) revealed higher turnover frequencies (TOFs) up 1.17 × 10 –2 mol C 2 H 2 mol −1 Ni min −1 and 1.98 × 10 –3 mol C 2 H 2 mol −1 Co min −1 for Ni-MFU-4l-OH and Co-MFU-4l-OH, respectively, compared to their BBTA analogues. However, the Co-based MOFs, particularly Co 2 (OH) 2 -BBTA, exhibited greater selectivity (up to 19%) for the fully hydrogenated ethane product. Isosteric heat of adsorption (Q st ) measurements for ethylene and ethane revealed that the BBTA framework had stronger binding to the products than MFU-4l. Furthermore, these findings demonstrate that metal identity and coordination environment may modulate acetylene hydrogenation performance, leading to design principles for tuning LOHC hydrogenation catalysts.

catalysts↗

Simultaneous stabilization and control of the n = 1 and n = 2 resistive wall mode

Abstract DIII-D experiments demonstrate simultaneous stability measurements and control of resistive wall modes (RWMs) with toroidal mode numbers n = 1 and n = 2. RWMs with n > 1 are sometimes observed on DIII-D following the successful feedback stabilization of the n = 1 mode, motivating the development of multi- n control. A new model-based multi-mode feedback algorithm based on the VALEN physics code has been implemented on the DIII-D tokamak using a real-time GPU installed directly into the DIII-D plasma control system. In addition to stabilizing RWMs, the feedback seeks to control the stable plasma error field response, enabling compensation of the typically unaddressed DIII-D n = 2 error field component. Experiments recently demonstrated this algorithm’s ability to simultaneously control n = 1 and n = 2 perturbed fields for the first time in a tokamak, using reactor relevant external coils. Control was maintained for hundreds of wall-times above the n = 1 no-wall pressure limit and approaching the n = 1 and n = 2 ideal-wall limits. Furthermore, a rotating non-zero target was set for the feedback, allowing stability to be assessed by monitoring the rotating plasma response (PR) while maintaining control. This novel technique can be viewed as a closed-loop extension of active MHD spectroscopy, which has been used to validate stability models through comparisons of the PR to applied, open-loop perturbations. The closed-loop response measurements are consistent with open-loop MHD spectroscopy data over a wide range of β N approaching the n = 1 ideal-wall limit. These PR measurements were then fit to produce both VALEN and single-mode stability models. These models allowed for important plasma stability information to be determined and have been shown to agree with experimentally observed RWM growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elemental profiling and genomewide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

Samples were collected from a population of 1,089 black cottonwood genotypes (P. trichocarpa) assembled from native stands to encompass the central portion of the natural range of the species, stretching from 38.8° to 54.3° N Q13 latitude from California, USA, to British Columbia, Canada. Establishment of the common garden, growth conditions, and site maintenance have been described by Muchero et al (2015). In this study, leaf samples for ionomic profiling were collected from 4-year-old trees, during the growing season, in July 2012, from a field located in Clatskanie, Oregon, USA (46°6′11″N 123°12′13″W). The field site was located in a protected alluvial floodplain containing a uniform Wauna-Locoda silt loam soil area characterized by an acidic pH, in Columbia County, Oregon. A subset of 584 out of the 1,089 P. trichocarpa genotypes were represented in this sampling. These genotypes were randomly selected to represent the geographical distribution of the population. A single fully mature (LPI 7-9) leaf on the south side of the tree exposed to full sunlight conditions was removed from the tree within a 6-hour window centering on solar noon and immediately frozen under dry ice before processing. Leaf samples of 584 P. trichocarpa genotypes were finely ground to 40 mm particle size using a mortar and pestle, and ionomic composition was analyzed using ICP-MS. In total, 20 elements were profiled, including aluminum (Al27), arsenic (As75), boron (B11), cadmium (Cd111), calcium (Ca43), cobalt (Co), copper (Cu), iron (Fe57), magnesium (Mg25), manganese (Mn55), molybdenum (Mo), nickel (Ni60), phosphorus (P31), potassium (K39), rubidium (Rb85), selenium (Se82), sodium (Na23), strontium (Sr88), sulfur (S34), and zinc (Zn66), following a protocol established by Ziegler et al. (2013). For each sample, 75mg of powder was digested overnight in 2.5 mL HNO3 containing 20 parts per billion (ppb) indium as an internal standard, following the protocol described in Ziegler et al. (2013). Following a dilution, concentration of the 20 elements was measured using an Elan 6000 DRC-e mass spectrometer (Perkin-Elmer SCIEX) connected to a PFA microflow nebulizer (Elemental Scientific) and Apex HF desolvator (Elemental Scientific). One measurement per sample per genotype was done. For subsequent analyses, the quantifications were converted to total element concentration.

CBI ionomics, GWAS, plasma-mass spectrometry, neut↗