Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accurate mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tannic Acid: a Novel Calibrator for Facile and Accurate Mass Measurement of Electrospray Ionization Mass Spectrometry

Accurate mass calibration is beneficial to the identification of the unknown compounds quickly and accurately. The ESI mass spectrum of tannic acid (TA) tends to a normal distribution of the cluster ion peaks in m/z range from 371.0368 to 1739.1169. Based on the interesting result, we reported the use of TA, a natural plant polyphenol, as a novel calibrator for electrospray ionization mass spectrometry (ESI MS), which has the following three advantages, including (1) easy preparation, (2) the calibration range of m/z 200~2000, and (3) the calibration error is around 3.00 ppm in positive ion mode, which is less than the use of sodium formate (SF) and Prod #88323 calibrators. This TA calibrator has great potential for the wide applications in biological, chemical, and pharmacal analysis. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of the accurate mass and time tag approach in studies of the human blood lipidome

We report a preliminary demonstration of the accurate mass and time (AMT) tag approach for lipidomics. Initial data-dependent LC-MS/MS analyses of human plasma, erythrocyte, and lymphocyte lipids were performed in order to identify lipid molecular species in conjunction with complementary accurate mass and isotopic distribution information. Identified lipids were used to populate initial lipid AMT tag databases containing 250 and 45 entries for those species detected in positive and negative electrospray ionization (ESI) modes, respectively. The positive ESI database was then utilized to identify human plasma, erythrocyte, and lymphocyte lipids in high-throughput quantitative LC-MS analyses based on the AMT tag approach. We were able to define the lipid profiles of human plasma, erythrocytes, and lymphocytes based on qualitative and quantitative differences in lipid abundance. In addition, we also report on the optimization of a reversed-phase LC method for the separation of lipids in these sample types.

59 BASIC BIOLOGICAL SCIENCES↗

A Support Vector Machine model for the prediction of proteotypic peptides for accurate mass and time proteomics

Motivation: The standard approach to identifying peptides based on accurate mass and elution time (AMT) compares these profiles obtained from a high resolution mass spectrometer to a database of peptides previously identified from tandem mass spectrometry (MS/MS) studies. It would be advantageous, with respect to both accuracy and cost, to only search for those peptides that are detectable by MS (proteotypic). Results: We present a Support Vector Machine (SVM) model that uses a simple descriptor space based on 35 properties of amino acid content, charge, hydrophilicity, and polarity for the quantitative prediction of proteotypic peptides. Using three independently derived AMT databases (Shewanella oneidensis, Salmonella typhimurium, Yersinia pestis) for training and validation within and across species, the SVM resulted in an average accuracy measure of ~0.8 with a standard deviation of less than 0.025. Furthermore, we demonstrate that these results are achievable with a small set of 12 variables and can achieve high proteome coverage. Availability: http://omics.pnl.gov/software/STEPP.php

59 BASIC BIOLOGICAL SCIENCES↗

A Statistical Method for Assessing Peptide Identification Confidence in Accurate Mass and Time Tag Proteomics

High-throughput proteomics is rapidly evolving to require high mass measurement accuracy for a variety of different applications. Increased mass measurement accuracy in bottom-up proteomics specifically allows for an improved ability to distinguish and characterize detected MS features, which may in turn be identified by, e.g., matching to entries in a database for both precursor and fragmentation mass identification methods. Many tools exist with which to score the identification of peptides from LC-MS/MS measurements or to assess matches to an accurate mass and time (AMT) tag database, but these two calculations remain distinctly unrelated. Here we present a statistical method, Statistical Tools for AMT tag Confidence (STAC), which extends our previous work incorporating prior probabilities of correct sequence identification from LC-MS/MS, as well as the quality with which LC-MS features match AMT tags, to evaluate peptide identification confidence. Compared to existing tools, we are able to obtain significantly more high-confidence peptide identifications at a given false discovery rate and additionally assign confidence estimates to individual peptide identifications. Freely available software implementations of STAC are available in both command line and as a Windows graphical application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Accurate Mass Determination for Kepler-1655b, a Moderately Irradiated World with a Significant Volatile Envelope

We present the confirmation of a small, moderately irradiated (F = 155 ± 7 F {sub ⊕}) Neptune with a substantial gas envelope in a P = 11.8728787 ± 0.0000085 day orbit about a quiet, Sun-like G0V star Kepler-1655. Based on our analysis of the Kepler light curve, we determined Kepler-1655b’s radius to be 2.213 ± 0.082 R {sub ⊕}. We acquired 95 high-resolution spectra with Telescopio Nazionale Galileo/HARPS-N, enabling us to characterize the host star and determine an accurate mass for Kepler-1655b of 5.0±{sub 2.8}{sup 3.1} M{sub ⊕} via Gaussian-process regression. Our mass determination excludes an Earth-like composition with 98% confidence. Kepler-1655b falls on the upper edge of the evaporation valley, in the relatively sparsely occupied transition region between rocky and gas-rich planets. It is therefore part of a population of planets that we should actively seek to characterize further.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MEGAMASER COSMOLOGY PROJECT. III. ACCURATE MASSES OF SEVEN SUPERMASSIVE BLACK HOLES IN ACTIVE GALAXIES WITH CIRCUMNUCLEAR MEGAMASER DISKS

Observations of H{sub 2}O masers from circumnuclear disks in active galaxies for the Megamaser Cosmology Project (MCP) allow accurate measurement of the mass of supermassive black holes (BH) in these galaxies. We present the Very Long Baseline Interferometry images and kinematics of water maser emission in six active galaxies: NGC 1194, NGC 2273, NGC 2960 (Mrk 1419), NGC 4388, NGC 6264 and NGC 6323. We use the Keplerian rotation curves of these six megamaser galaxies, plus a seventh previously published, to determine accurate enclosed masses within the central {approx}0.3 pc of these galaxies, smaller than the radius of the sphere of influence of the central mass in all cases. We also set lower limits to the central mass densities of between 0.12 x 10{sup 10} and 61 x 10{sup 10} M{sub sun} pc{sup -3}. For six of the seven disks, the high central densities rule out clusters of stars or stellar remnants as the central objects, and this result further supports our assumption that the enclosed mass can be attributed predominantly to a supermassive BH. The seven BHs have masses ranging between 0.75 x 10{sup 7} and 6.5 x 10{sup 7} M{sub sun}, with the mass errors dominated by the uncertainty of the Hubble constant. We compare the megamaser BH mass determination with BH mass measured from the virial estimation method. The virial estimation BH mass in four galaxies is consistent with the megamaser BH mass, but the virial mass uncertainty is much greater. Circumnuclear megamaser disks allow the best mass determination of the central BH mass in external galaxies and significantly improve the observational basis at the low-mass end of the M-{sigma}{sub *} relation. The M-{sigma}{sub *} relation may not be a single, low-scatter power law as originally proposed. MCP observations continue and we expect to obtain more maser BH masses in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

ACCURATE MASSES FOR THE PRIMARY AND SECONDARY IN THE ECLIPSING WHITE DWARF BINARY NLTT 11748

We measure the radial velocity curve of the eclipsing detached white dwarf binary NLTT 11748. The primary exhibits velocity variations with a semi-amplitude of 273 km s{sup -1} and an orbital period of 5.641 hr. We do not detect any spectral features from the secondary star or any spectral changes during the secondary eclipse. We use our composite spectrum to constrain the temperature and surface gravity of the primary to be T {sub eff} = 8690 {+-} 140 K and log g = 6.54 {+-} 0.05, which correspond to a mass of 0.18 M {sub sun}. For an inclination angle of 89.{sup 0}9 derived from the eclipse modeling, the mass function requires a 0.76 M {sub sun} companion. The merger time for the system is 7.2 Gyr. However, due to the extreme mass ratio of 0.24, the binary will most likely create an AM CVn system instead of a merger.

79 ASTRONOMY AND ASTROPHYSICS↗

ACCURATE MASS ESTIMATORS FOR NAVARRO-FRENK-WHITE HALOS

We consider the problem of estimating the virial mass of a dark halo from the positions and velocities of a tracer population. Although a number of general tools are available, more progress can be made if we are able to specify the functional form of the halo potential (although not its normalization). Here, we consider the Navarro-Frenk-White halo and develop two simple estimators. We demonstrate their effectiveness against numerical simulations and use them to provide new mass estimates of Carina, Fornax, Sculptor, and Sextans dwarf spheroidal galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate mass determinations in decay chains with missing energy: II

We discuss kinematic methods for determining the masses of the particles in events at a hadron collider in which a pair of identical particles is produced with each decaying via a series of on shell intermediate beyond-the-standard model (BSM) particles to visible standard model (SM) particles and an invisible particle (schematically, pp{yields}ZZ+jets with Z{yields}Aa{yields}Bba{yields}Ccba{yields}...{yields}cba...+N where a,b,c,... are visible SM particles or groups of SM particles, A,B,C,... are on shell BSM particles, and N is invisible). This topology arises in many models including supersymmetry (SUSY) processes such as squark and gluino pair production and decay. We present the detailed procedure for the case of Z{yields}3 visible particles+N and demonstrate that the masses obtained from the kinematic procedure are independent of the model by comparing SUSY to universal extra dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate Mass Determinations in Decay Chains with Missing Energy

Many beyond the standard model theories include a stable dark matter candidate that yields missing or invisible energy in collider detectors. If observed at the CERN Large Hadron Collider, we must determine if its mass and other properties (and those of its partners) predict the correct dark matter relic density. We give a new procedure for determining its mass with small error.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Application of a Triple Bubbler System in Molten Salt for Accurate Mass and Volume Determination

Ongoing testing of the triple bubbler system has been applied to molten salt systems. The instrumentation was developed at Idaho National Laboratory for continuous monitoring of special nuclear materials in molten salt; and the instrument utilizes three dip tubes for determining the mass and volume of a liquid in a vessel. This paper will discuss the important design criteria of the bubbler probe for molten salt systems; and will describe lessons learned from using the system in a molten salt environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Evaluation of Preprocessing Freeware on Chromatography/Mass Spectrometry Data for Signature Discovery

Preprocessing software is crucial for the discovery of chemical signatures in metabolomics, chemical forensics, and other signature-focused disciplines that involve analyzing large data sets from chemical instruments. Here, four freely available and published preprocessing tools known as metAlign, MZmine, SpectConnect, and XCMS were evaluated for impurity profiling using nominal mass GC/MS data and accurate mass LC/MS data. Both data sets were previously collected from the analysis of replicate samples from multiple stocks of a nerve-agent precursor. Each of the four tools had their parameters set for the untargeted detection of chromatographic peaks from impurities present in the stocks. The peak table generated by each preprocessing tool was analyzed to determine the number of impurity components detected in all replicate samples per stock. A cumulative set of impurity components was then generated using all available peak tables and used as a reference to calculate the percent of component detections for each tool, in which 100% indicated the detection of every component. For the nominal mass GC/MS data, metAlign performed the best followed by MZmine, SpectConnect, and XCMS with detection percentages of 83, 60, 47, and 42%, respectively. For the accurate mass LC/MS data, the order was metAlign, XCMS, and MZmine with detection percentages of 80, 45, and 35%, respectively. SpectConnect did not function for the accurate mass LC/MS data. Larger detection percentages were obtained by combining the top performer with at least one of the other tools such as 96% by combining metAlign with MZmine for the GC/MS data and 93% by combining metAlign with XCMS for the LC/MS data. In terms of quantitative performance, the reported peak intensities had average absolute biases of 41, 4.4, 1.3 and 1.3% for SpectConnect, metAlign, XCMS, and MZmine, respectively, for the GC/MS data. For the LC/MS data, the average absolute biases were 22, 4.5, and 3.1% for metAlign, MZmine, and XCMS, respectively. In summary, metAlign performed the best in terms of peak discovery; however, more than one preprocessing tool should be considered to avoid missing potential chemical signatures.

chemical forensics, chemometrics↗

THE IMPACT OF CLUSTER STRUCTURE AND DYNAMICAL STATE ON SCATTER IN THE SUNYAEV-ZEL'DOVICH FLUX-MASS RELATION

Cosmological constraints from cluster surveys rely on accurate mass estimates from the mass-observable relations. In order to avoid systematic biases and reduce uncertainties, we study the form and physical origin of the intrinsic scatter about the mean Sunyaev-Zel'dovich (SZ) flux-mass relation using a hydrodynamical simulation of galaxy cluster formation. We examine the assumption of lognormal scatter and detect non-negligible positive skewness and kurtosis (>0.5) for a wide range of limiting masses and redshifts. These higher order moments should be included in the parameterization of scatter in order not to bias cosmological constraints. We investigate the sources of the scatter by correlating it with measures of cluster morphology, halo concentration, and dynamical state, and quantify the individual contribution from each source. We find that statistically the impact of the dynamical state is weak, so the selection bias due to mergers is negligible. On the other hand, there is a strong correlation between the scatter and halo concentration, which can be used to reduce the scatter significantly (from 12.07% to 7.34% or by {approx}40% for clusters at z = 0). We also show that a cross-calibration by combining information from X-ray follow-ups can be used to reduce the scatter in the flux-mass relation and also identify outliers in both X-ray and SZ cluster surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Gas-Phase Chemistry in the GC Orbitrap Mass Spectrometer

Gas-phase reactions of temporally stored ions play a significant role in trapped ion mass spectrometry. Especially highly labile ion species generated through electron ionization (EI) are prone to undergo gas-phase reactions after relaxation to a low vibrational state. Here, we show that in the C-Trap of the Q Exactive GC Orbitrap mass spectrometer, gaseous water reacts with radical cations of various compound classes. High-resolution accurate mass spectrometry of the resulting ions provides a key to the mechanistic understanding of the chemistry of high energetic species generated during EI. We systematically addressed water adduct formation by use of H{sub 2}O and D{sub 2}{sup 18}O in the C-Trap. Mass spectra of halogen cyanides XCN (X=Cl, Br, I) showed the formation of HXCN{sup +} species, indicating hydrogen atomic transfer reactions. Relative ratios of HXCN{sup +}/XCN{sup +•} increased as the electronegativity of the halide increased. The common internal calibrant perfluorotributylamine forms oxygenated products from water reactive fragment ions. These can be explained by the addition of water to an initial cation followed by elimination of two HF molecules. This addition/elimination chemistry can also explain [M+2]{sup +} and [M+3]{sup +} ions that commonly occur in mass spectra of silylated analytes. High-resolution accurate mass spectra of trimethylsilyl (TMS) derivatives revealed these as [M−CH{sub 3}{sup •}+H{sub 2}O]{sup +} and [M−CH{sub 4}+H{sub 2}O]{sup •+}, respectively. This study explains common fragment ions in ion trap mass spectrometry. It also opens up perspectives for the systematic mechanistic and kinetic investigation of high-energy ion reactivity. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Molecular Characterization of Biomass Burning Aerosols Using High Resolution Mass Spectrometry

Chemical characterizations of atmospheric aerosols is a serious analytical challenge because of the complexity of particulate matter analyte composed of a large number of compounds with a wide range of molecular structures, physico-chemical properties, and reactivity. In this study chemical composition of biomass burning organic aerosol (BBOA) samples is characterized by high resolution electrospray ionization mass spectrometry (ESI/MS). Accurate mass measurement combined with Kendrick analysis allowed us to assign elemental composition for hundreds of compounds in the range of m/z values of 50-1000. ESI/MS spectra of different BBOA samples contain a variety of distinct, sample specific, characteristic peaks that can be used as unique markers for different types of biofuels. Our results indicate that a significant number of high-MW organic compounds in BBOA samples are highly oxidized polar species that can be efficiently detected using ESI/MS but are difficult to observe using the conventional GCMS analysis of aerosol samples. The average O:C ratios obtained for each of the BBOA samples studied in this work are in a strikingly good agreement with the previously reported values obtained using STXM/NEXAFS. The degree of unsaturation of detected organic compounds shows a clear decrease with increase in the molecular weight of the anyalyte molecules. The decrease is particularly pronounced for the samples containing a large number of CH2-based homologous series.

09 BIOMASS FUELS↗

Molecular Characterization of Nitrogen Containing Organic Compounds in Biomass Burning Aerosols Using High Resolution Mass Spectrometry

Although nitrogen-containing organic compounds (NOC) are important components of atmospheric aerosols, little is known about their chemical compositions. Here we present detailed characterization of the NOC constituents of biomass burning aerosol (BBA) samples using high resolution electrospray ionization mass spectrometry (ESI/MS). Accurate mass measurements combined with MS/MS fragmentation experiments of selected ions were used to assign molecular structures to individual NOC species. Our results indicate that N-heterocyclic alkaloid compounds - species naturally produced by plants and living organisms - comprise a substantial fraction of NOC in BBA samples collected from test burns of five biomass fuels. High abundance of alkaloids in test burns of ponderosa pine - a widespread tree in the western U.S. areas frequently affected by large scale fires - suggests that N-heterocyclic alkaloids in BBA can play a significant role in dry and wet deposition of fixed nitrogen in this region.

09 BIOMASS FUELS↗

193 nm Ultraviolet Photodissociation for the Characterization of Singly Charged Proteoforms Generated by MALDI

MALDI imaging allows for the near-cellular profiling of proteoforms directly from microbial, plant, and mammalian samples. Despite detecting hundreds of proteoforms, identification of unknowns with only intact mass information remains a distinct challenge, even with high mass resolving power and mass accuracy. To this end, many supplementary methods have been used to create experimental databases for accurate mass matching, including bulk or spatially resolved bottom-up and/or top-down proteomics. Herein, we describe the application of 193 nm ultraviolet photodissociation (UVPD) for fragmentation of quadrupole isolated singly charged ubiquitin (m/z 8565) by MALDI-UVPD on a UHMR HF Orbitrap. This platform permitted the high-resolution accurate mass measurement of not just terminal fragments but also large internal fragments. Finally, the outlined workflow demonstrates the feasibility of top-down analyses of isolated MALDI protein ions and the potential toward more comprehensive characterization of proteoforms in MALDI imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cluster abundance in chameleon f ( R ) gravity I: toward an accurate halo mass function prediction

We refine the mass and environment dependent spherical collapse model of chameleon f ( R ) gravity by calibrating a phenomenological correction inspired by the parameterized post-Friedmann framework against high-resolution N -body simulations. We employ our method to predict the corresponding modified halo mass function, and provide fitting formulas to calculate the enhancement of the f ( R ) halo abundance with respect to that of General Relativity (GR) within a precision of ∼< 5% from the results obtained in the simulations. Similar accuracy can be achieved for the full f ( R ) mass function on the condition that the modeling of the reference GR abundance of halos is accurate at the percent level. We use our fits to forecast constraints on the additional scalar degree of freedom of the theory, finding that upper bounds competitive with current Solar System tests are within reach of cluster number count analyses from ongoing and upcoming surveys at much larger scales. Importantly, the flexibility of our method allows also for this to be applied to other scalar-tensor theories characterized by a mass and environment dependent spherical collapse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗