Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator mass spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

National User Resource for Biological Accelerator Mass Spectrometry

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science.

59 BASIC BIOLOGICAL SCIENCES↗

National User Resource for Biological Accelerator Mass Spectrometry (Annual Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH-funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation of Lipoproteins for Quantitative Analysis of 14 C-Labeled Lipid-Soluble Compounds by Accelerator Mass Spectrometry

To date, 14 C tracer studies using accelerator mass spectrometry (AMS) have not yet resolved lipid-soluble analytes into individual lipoprotein density subclasses. The objective of this work was to develop a reliable method for lipoprotein separation and quantitative recovery for biokinetic modeling purposes. The novel method developed provides the means for use of small volumes (10–200 µL) of frozen plasma as a starting material for continuous isopycnic lipoprotein separation within a carbon- and pH-stable analyte matrix, which, following post-separation fraction clean up, created samples suitable for highly accurate 14 C/ 12 C isotope ratio determinations by AMS. Manual aspiration achieved 99.2 ± 0.41% recovery of [5- 14 CH 3 ]-(2R, 4'R, 8'R)-α-tocopherol contained within 25 µL plasma recovered in triacylglycerol rich lipoproteins (TRL = Chylomicrons + VLDL), LDL, HDL, and infranatant (INF) from each of 10 different sampling times for one male and one female subject, n = 20 total samples. Small sample volumes of previously frozen plasma and high analyte recoveries make this an attractive method for AMS studies using newer, smaller footprint AMS equipment to develop genuine tracer analyses of lipophilic nutrients or compounds in all human age ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial tests of Accelerator Mass Spectrometry with the Argonne Gas-Filled Analyzer and the commissioning of the MONICA detector

As the scope of Accelerator Mass Spectrometry (AMS) expands, there is an increased need to extend the capability of isobaric separation to the medium-heavy mass region. Existing AMS facilities are limited in their ability to separate radioactive nuclei in the A = 100–200 range of interest from their neighboring stable isobars, as such measurements require higher energies than available in most facilities. ATLAS is one of the highest energy system used for AMS based experiments and has enabled isobaric discrimination for medium to heavy nuclides, notably via the Gas-Filled Magnet technique. Further, a preparatory experiment performed in November, 2019, successfully demonstrated isobaric separation of 92 Zr- 92 Mo using the Argonne Gas-Filled Analyzer (AGFA) with high magnetic rigidity. Since that time, MONICA, an eight-anode ionization chamber that measures both energy loss and position with two sets of split anodes, has been developed to aid in AMS experiments at AGFA and has undergone four commissioning runs at the Nuclear Science Laboratory at the University of Notre Dame utilizing Si, Fe/Ni, and Mn beams. This report presents the AGFA AMS run (November 2019) and the subsequent commissioning runs of the MONICA detector, including preliminary measurements on the long-lived isotopes 39 Ar (268 y) and for the first time on 42 Ar (33 y).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of phenanthrene co-administration on the toxicokinetics of benzo[a]pyrene in humans. UPLC-accelerator mass spectrometry following oral microdosing

Current risk assessments for environmental carcinogens rely on animal studies utilizing doses orders of magnitude higher than actual human exposures. Epidemiological studies of people with high exposures (e.g., occupational) are of value, but rely on uncertain exposure data. In addition, exposures are typically not to a single chemical but to mixtures, such as polycyclic aromatic hydrocarbons (PAHs). The extremely high sensitivity of accelerator mass spectrometry (AMS) allows for dosing humans with known carcinogens with de minimus risk. In this study UPLC-AMS was used to assess the toxicokinetics of [ 14 C]-benzo[a]pyrene ([ 14 C]-BaP) when dosed alone or in a binary mixture with phenanthrene (Phe). Plasma was collected for 48 h following a dose of [ 14 C]-BaP (50 ng, 5.4 nCi) or the same dose of [ 14 C]-BaP plus Phe (1250 ng). Following the binary mixture, C max of [ 14 C]-BaP significantly decreased (4.4-fold) whereas the volume of distribution (V d ) increased (2-fold). Further, the toxicokinetics of twelve [ 14 C]-BaP metabolites provided evidence of little change in the metabolite profile of [ 14 C]-BaP and the pattern was overall reduction consistent with reduced absorption (decrease in C max ). Although Phe was shown to be a competitive inhibitor of the major hepatic cytochrome P-450 (CYP) responsible for metabolism of [ 14 C]-BaP, CYP1A2, the high inhibition constant (K i ) and lack of any increase in unmetabolized [ 14 C]-BaP in plasma makes this mechanism unlikely to be responsible. Rather, co-administration of Phe reduces the absorption of [ 14 C]-BaP through a mechanism yet to be determined. Furthermore, this is the first study to provide evidence that, at actual environmental levels of exposure, the toxicokinetics of [ 14 C]-BaP in humans is markedly altered by the presence of a second PAH, Phe, a common component of environmental PAH mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiological Characterization of Hard to Measure Nuclides Using Accelerator Mass Spectrometry (AMS) - 20140

In this project irradiated heavy concrete was characterized regarding hard to measure nuclides like Ca-41 using Accelerator Mass Spectrometry (AMS). Concrete samples were irradiated with a known neutron flux and the Ca-41 content was investigated via AMS measurements. The comparison of the results with calculations shows a very good agreement in the Ca-41 content. The project revealed that AMS can be used to characterize irradiated concrete and contributes to improve the methodological basis of the radiological characterization and to extending the validation of nuclide vectors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Producing 236 U reference standards for Accelerator Mass Spectrometry at the University of Notre Dame

36 U is a rare isotope of uranium, naturally occurring in ores with an abundance of 236 U/ 238 U$<$ 1 x 10 -9 . The ability to detect it and make isotopic ratio measurements has applications ranging from nuclear forensics and nonproliferation to energy production and environmental protection. Currently, Accelerator Mass Spectrometry (AMS) is the only technique sensitive enough to accurately measure 236 U/ 238 U isotopic ratios as they exist in naturally occurring ores in the range of 236 U/ 238 U = 10 -12 $-$ 10 -9 . Some AMS facilities have demonstrated their capabilities to make these measurements. Historically, the lack of commercially available reference standards covering the range of naturally occurring 236 U/ 238 U abundances has necessitated the use of absolute measurements, notoriously difficult to do using AMS, resulting in increased uncertainties in measurements and a reliance on knowledge of systematic effects. To mitigate these issues, various AMS facilities have sought to develop their own reference standards. Using a reference standard prepared for other forms of mass spectrometry, a series of AMS suitable standards was created through dilution with low-background natural uranium. The techniques used to produce and characterize these materials as well as analysis of them using AMS will be discussed.

236U↗

Pharmacokinetics, Metabolite Measurement, and Biomarker Identification of Dermal Exposure to Permethrin Using Accelerator Mass Spectrometry

Impregnating military uniforms and outdoor clothing with the insecticide permethrin is an approach to reduce exposure to insect borne diseases and to repel pests and disease vectors such as mosquitos and sandflies, but the practice exposes wearers to prolonged dermal exposure to the pesticide. Key metabolite(s) from a low dose dermal exposure of permethrin were identified using accelerator mass spectrometry. Metabolite standards were synthesized and a high performance liquide chromatography (HPLC) elution protocol to separate individual metabolites in urine was developed. Six human subjects were exposed dermally on the forearm to 25 mg of permethrin containing 1.0 µCi of 14 C for 8 h. Blood, saliva and urine samples were taken for 7d. Absorption/elimination rates and metabolite concentrations varied by individual. Average absorption was 0.2% of the dose. Serum concentrations rose until 12–24 h postdermal application then rapidly declined reaching predose levels by 72 h. Maximum saliva excretion occurred 6 h postdosing. The maximum urinary excretion rate occurred during 12–24 h; average elimination half-life was 56 h. 3-Phenoxybenzyl alcohol glucuronide was the most abundant metabolite identified when analyzing elution fractions, but most of the radioactivity was in still more polar fractions suggesting extensive degradative metabolism and for which there were no standards. Finally, analyses of archived urine samples with the ultra performance liquid chromatography-accelerator mass spectrometry-mass spectrometry (UPLC-AMS-MS) system isolated a distinct polar metabolite but it was much diminished from the previous analyses a decade earlier.

59 BASIC BIOLOGICAL SCIENCES↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials

Here, we present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post-detonation nuclear forensics. The glasses were generated by melting and then quenching SiO 2 , Al 2 O 3 and CaCO 3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235 U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g -1 . Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry-single stage accelerator mass spectrometry [SIMS-SSAMS], large geometry [LG] - SIMS, and laser ablation-inductively coupled plasma-mass spectrometry [LA-ICP-MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.

36 MATERIALS SCIENCE↗

HPLC-Parallel accelerator and molecular mass spectrometry analysis of 14 C-labeled amino acids

Accelerator mass spectrometry (AMS) is the method of choice for quantitation of low amounts of 14 C-labeled biomolecules. Despite exquisite sensitivity, an important limitation of AMS is its inability to provide structural information about the analyte. This limitation is not critical when the labeled compounds are well-characterized prior to AMS analysis. However, analyte identity is important in other experiments where, for example, a compound is metabolized and the structures of its metabolites are not known. We previously described a moving wire interface that enables direct AMS measurement of liquid sample in the form of discrete drops or HPLC eluent without the need for individual fraction collection, termed liquid sample-AMS (LS-AMS). Here, we now report the coupling of LS-AMS with a molecular mass spectrometer, providing parallel accelerator and molecular mass spectrometry (PAMMS) detection of analytes separated by liquid chromatography. The repeatability of the method was examined by performing repeated injections of 14 C-labeled tryptophan, and relative standard deviations of the 14 C peak areas were ≤10.57% after applying a normalization factor based on a standard. Five 14 C-labeled amino acids were separated and detected to provide simultaneous quantitative AMS and structural MS data, and AMS results were compared with solid sample-AMS (SS-AMS) data using Bland-Altman plots. To demonstrate the utility of the workflow, yeast cells were grown in a medium with 14 C-labeled tryptophan. The cell extracts were analyzed by PAMMS, and 14 C was detected in tryptophan and its metabolite kynurenine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

Quantitative Determination of Biomass-derived Renewable Carbon in Fuels from Coprocessing of Bio-oils in Refinery Using a Stable Carbon Isotopic Approach

Increasing renewable carbon incorporation into conventional fuels through coprocessing with vacuum gas oil (VGO, a petroleum refining feedstock) is a critical step in biofuels development, scaling-up, adoption and associated GHG reduction. Optimization of the co-processing parameters maximizes incorporation of the renewable carbon in the fuel products. Quantitative determination of the renewable carbon content in the co-processed products provides direct evaluation of the parameters. The co-processing bio-oil with VGO through hydrocracking (HC) or fluid catalytic cracking (FCC) system resulted in carbon isotopic fractionation that prevented the direct use of the isotope mixing model for quantifying the renewable carbon. Here, we report an algorithm of using a stable carbon isotope approach to quantify the renewable carbon content in co-processing biofuel products through high-precision ?13C analysis. A controlled experiment carried out by blending a fossil diesel (-29.013‰) with a bio-diesel (-30.099‰) at various blending levels up to 98.0/2.0 wt% is presented and has demonstrated the applicability of this approach. The carbon isotope fractionation factors for the bio-oil co-processing were obtained by using a 14C-derived isotope-mixing model. The ?13C method was tested by co-processing 13C-labeled bio-crude and natural woody biomass-derived fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils with VGO. The results were verified by 14C accelerator mass spectrometry (AMS) method (ASTM-D6866) and compared with the yield mass balance (YMB) method. Strong agreement between d13C and 14C AMS methods demonstrated the applicability of the ?13C method to quantify renewable carbon content in co-processing fuel products and guide the co-processing optimization

Li, Zhenghua↗

Bio-distribution and deposition of wildfire smoke chemicals into olfactory bulb and brain of rats after intranasal instillation

Epidemiological and experimental studies suggest wildfire smoke is a potential contributor to neurological dysfunction and associated with neuroinflammation. Using doses comparable to those encountered during intense wildfire events (200-300 μg/m 3 ), we explore the absorption, distribution, metabolism, and elimination (ADME) and pharmacokinetics of representative members of major chemical classes (acid, phenol, PAH, aldehyde) in inhaled wood smoke condensates. Male Sprague Dawley rats were intranasally instilled with smoldering eucalyptus woodsmoke extract (WSE) reconstituted in saline spiked with 14 C-labeled palmitic acid (PA), benzo[a]pyrene (B[a]P), catechol (CAT) or benzaldehyde (BZ). Serum was collected from 5 min to 2 weeks after exposure and tissues were collected at 0.5, 2, 4, 24 h and 2 weeks after exposure. Urine was collected over the 24 h exposure. Tissues were collected, rinsed in PBS and analyzed by accelerator mass spectrometry (AMS) for 14C-labeled chemicals. PA and B[a]P entered circulation slowly, reached maximum concentration (C max ) near 15 ng/mL at 2 h, and had circulating concentrations near 1/3 C max 24 h after exposure. CAT and BZ rapidly entered circulation and were mostly cleared at 2 h. Excess 14 C from all four chemicals was detected in olfactory bulb and brain over the first 24 h but only PA (or its metabolites) was retained in olfactory bulb, brain and kidney at 2 weeks post exposure. All excess 14 C was cleared from the lung at 2 weeks. Metabolite analysis of urine (CAT, BZ and B(a)P) dosed samples did not detect any parent compound. CAT and BZ were rapidly cleared. The slower uptake and clearance of PA or B[a]P or their reactive metabolites when dosed with WSE in brain and olfactory bulb potentially provide greater opportunity for inflammatory response. This study suggests that wildfire smoke chemicals can enter the brain directly from the nasal cavity to the olfactory bulb and via systemic circulation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗