Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics

The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.

Yadav, M. [University of California, Los Angeles, ↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Scorpius Accelerator Emittance Diagnostic Design

The 14th International Particle Accelerator Conference (IPAC’23) will be held in Venice, Italy from 7 to 12 May 2023 at the Venice Convention Centre. Website: https://www.ipac23.org/ Presenter: Mark Raphaelian Dear Mark, we acknowledge reception of your abstract #1268 for IPAC'23 - 14th International Particle Accelerator Conference. Here follow the details: Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator Classification: MC6.T03: Beam Diagnostics and Instrumentation Type of presentation: Poster Presentation Submitter: Mark Raphaelian Authors: Mark Raphaelian Co-Authors: Daniel Dzenitis, Franz Weber, Nathaniel Pogue, Sean Littleton, Steven Falabella, Patrick Duffy, William Stem

47 OTHER INSTRUMENTATION↗

Model-driven prediction for accelerator magnet diagnostics to improve operation reliability

Reliability is one of the most critical metrics for accelerator operation, especially in user facilities. To reduce costly facility downtime and provide an operational environment where system performance can be reliably predicted in support of scientific studies, we are developing a model-driven approach for prediction and anomaly detection. Here, in this study, we present the application of a model-driven method that employs a linear regression model to predict the future temperature, in real time, of accelerator magnets at the NSLS-II light source. This approach enables proactive identification of magnet-heating issues, facilitating magnet flushing prior to the occurrence of permanent damage without interrupting machine operation. The implementation of this method in the NSLS-II control room is described and the analysis of the online results is presented. The results demonstrate the model’s effectiveness in providing early alerts to engineers and improving the reliability of accelerator operations.

36 MATERIALS SCIENCE↗

Application of the portable diagnostic package to the Wisconsin high-temperature-superconducting axisymmetric mirror (WHAM)

We present an application of the Portable Diagnostic Package (PDP) on the Wisconsin High-temperature-superconducting Axisymmetric Mirror (WHAM), which integrates an optical emission spectroscopy (OES) system and an active Thomson scattering (TS) system. The OES system facilitates a comprehensive impurity line survey and enables flow measurements through the Doppler effect observed on impurity lines. Plasma rotation profiles were successfully derived from doubly charged carbon lines. The TS system enabled the first measurements of the electron temperature in commissioning plasmas on WHAM. Notably, the PDP was installed, commissioned, and used to obtain OES and TS data within ∼6 months from project start, enabled by its designed portability and standardized interfaces. These results demonstrate the PDP’s potential to accelerate diagnostic readiness and advance experimental plasma studies.

Doppler effect↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CryoET reveals organelle phenotypes in huntington disease patient iPSC-derived and mouse primary neurons

Huntington’s disease (HD) is caused by an expanded CAG repeat in the huntingtin gene, yielding a Huntingtin protein with an expanded polyglutamine tract. While experiments with patient-derived induced pluripotent stem cells (iPSCs) can help understand disease, defining pathological biomarkers remains challenging. Here, we used cryogenic electron tomography to visualize neurites in HD patient iPSC-derived neurons with varying CAG repeats, and primary cortical neurons from BACHD, deltaN17-BACHD, and wild-type mice. In HD models, we discovered sheet aggregates in double membrane-bound organelles, and mitochondria with distorted cristae and enlarged granules, likely mitochondrial RNA granules. We used artificial intelligence to quantify mitochondrial granules, and proteomics experiments reveal differential protein content in isolated HD mitochondria. Knockdown of Protein Inhibitor of Activated STAT1 ameliorated aberrant phenotypes in iPSC- and BACHD neurons. We show that integrated ultrastructural and proteomic approaches may uncover early HD phenotypes to accelerate diagnostics and the development of targeted therapeutics for HD.

59 BASIC BIOLOGICAL SCIENCES↗

Computational diagnostics for flame acceleration and transition to detonation in a hydrogen/air mixture

A new computational diagnostic method for pressure-induced compressibility is proposed by projecting its local contribution to the chemical explosive mode (CEM) in the chemical explosive mode analysis (CEMA) framework. The new method is validated for the study of detonation development during the deflagration-to-detonation transition (DDT) process. The flame characteristics are identified through the quantification of individual CEM contributions of chemical reaction, diffusion, and pressure-induced compressibility. Numerical simulations are performed to investigate the DDT processes in a stoichiometric hydrogen-air mixture. A Godunov algorithm, fifth-order in space, and third-order in time are used to solve the fully compressible Navier-Stokes equations on a dynamically adapting mesh. A single-step, calibrated chemical diffusive model (CDM) described by Arrhenius kinetics is used for energy release and conservation between the fuel and the product. The new diagnostic method is first applied to onedimensional (1D) canonical flame configurations followed by two-dimensional (2D) simulations of DDT in an obstructed channel where different detonation initiation scenarios are examined using the new CEMA projection formulation. Detailed examinations of the idealized configuration of detonation initiation through shock focusing mechanism at a flame front are also studied using the new formulation. A comparison of the currently proposed CEMA projection and the original formulation by the authors suggests that including the pressure-induced compressibility is essential for the use of CEMA in DDT process. The results also show that the new formulation of CEMA projection can successively capture the detonation initiation through either a gradient mechanism or a direct initiation mechanism, and therefore can be used as an effective local analytical tool for the computational diagnostics of detonation initiation in a DDT process. It was found that detonation development is characterized by a strong contribution of chemistry role to the CEM which is pivotal to the initiation of detonation. The role of compressibility is found enhanced at the edge of the detonation front where diffusion was found to have minimal effects on detonation development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗