Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

BEAM ACCELERATION WITH A Nb3Sn CRYOMODULE AT JLAB

We report on the electron beam acceleration experiment with a Nb3Sn cryomodule at Thomas Jefferson National Laboratory (JLAB). Two CEBAF-style 5-cell 1.5 GHz Nb3Sn cavities operated at 4 K, accelerating a 100 nA continuous-wave (CW) electron beam from 200 keV to 4 MeV at JLAB’s Upgraded Injector Test Facility (UITF). The acceleration gradients in each cavity reached 11 MV/m and 7 MV/m, respectively. No field emission was observed. The unloaded quality factors reached 2¿109 at low fields at 4 K.

Geng, R. [Thomas Jefferson National Accelerator Fa↗

Cooling plate assembly for plasma windows positioned in a beam accelerator system

A beam accelerator system operable to produce a medical isotope, including an ion accelerator that generates an ion beam; a low-pressure chamber; an anode adjacent and fluidly connected to the low-pressure chamber; a plasma window adjacent and fluidly connected to the anode; and a cathode housing adjacent and fluidly connected to the plasma window. The plasma window has a plurality of plates, each plate having an aperture that is aligned with an aperture in one or more adjacent plates to form a plasma channel. One or more plates in the plurality of plates includes a unitary plate having an aperture therein, and one or more cooling channels entering the unitary plate at a first side of the unitary plate and exiting the unitary plate at a second side of the unitary plate. The one or more cooling channels run through a thickness of the unitary plate.

Gribb, Tye↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.

Hull, Caleb James↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Characterization of High-Entropy Alloys for Accelerator Beam Window Applications

Particle production targets and accelerator beam windows receive millions of high-energy/intensity beam pulses throughout their service lifetime. For next-generation multi-MW accelerators, it is necessary for beam windows to be able to withstand higher levels of thermal shock and radiation damage, while also having good high-temperature mechanical properties. Novel High-Entropy Alloys (HEAs) that form a single-phase microstructure, have nanoscale precipitates, and are made from low-Z elements are good candidates for beam window materials. This is due to their high-temperature strength and high resistance to radiation-induced swelling and hardening, as well as their beam transparency, allowing for maximized particle production and a longer service lifetime.

Kidwell, Tristan [U. Chicago (main)] (ORCID:000900↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Graphite for Accelerator Beam Intercepting Devices

Nuclear grade fine-grain graphite has played a central role in particle accelerator Beam Intercepting Devices, BID (e.g. targets or beam dumps) for decades, especially for high beam power facilities, such as at Fermilab, CERN, PSI and JPARC. Operations of these facilities have demonstrated graphite’s reliable performance at beam powers up to about 1 MW and enduring over 10 million thermal shock cycles of over 3x10 7 K/s. Planned future accelerator facilities will push BID beam power capability into the multi-MW regime. The material challenges of such MW-class accelerator facilities, how graphite may meet those challenges, as well as an overview of recent and current research on graphite for high power accelerator BID will be presented.

Burleigh, Abe [Fermilab]↗

U.S. advanced and novel accelerator beam test facilities

Demonstrating the viability of Advanced Accelerator Concepts (AAC) relies on experimental validation. Over the last three decades, the U.S. has maintained a portfolio of advanced and novel accelerator test facilities to support research critical to AAC. The facilities have enabled pioneering developments in a wide variety of beam and accelerator physics, including plasma-wakefield and structure-wakefield acceleration. This work provides an overview of the current portfolio of U.S. facilities possessing charged particle drive beams with high energies, on the order of tens of joules per pulse, or drive lasers with high peak powers, on the order of a petawatt, and are actively conducting AAC research.

43 PARTICLE ACCELERATORS↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Charge lifetime improvement of the Continuous Electron Beam Accelerator Facility photogun with a biased anode

GaAs photocathodes in dc high-voltage photoguns are highly susceptible to ion back-bombardment, which reduces the photocathode quantum efficiency and limits the useful operating lifetime for producing polarized electron beams. This paper demonstrates that applying a small positive bias to the photogun anode can significantly suppress ion back-bombardment and increase charge lifetime. This technique was studied extensively using the Continuous Electron Beam Accelerator Facility photogun, where highly polarized electron beams created using a strained-superlattice GaAs / GaAsP photocathode were used and charge lifetimes improved by almost a factor of 2. A new simulation code was developed to model ion production and tracking in order to better understand and explain the factors that led to the performance improvement. Results of the experiments and simulations are discussed in detail. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

US Advanced and Novel Accelerator Beam Test Facilities

Demonstrating the viability of Advanced Accelerator Concepts (AAC) relies on experimental validation. Over the last three decades, the US has maintained a portfolio of advanced and novel accelerator test facilities to support research critical to AAC. The facilities have enabled pioneering developments in a wide variety of beam and accelerator physics, including plasma-wakefeld and structure-wakefeld acceleration. This paper provides an overview of the current portfolio of US facilities possessing charged particle drive beams with high energies, on the order of tens of joules per pulse, or drive lasers with high peak powers, on the order of a petawatt, and are actively conducting AAC research.

Clarke, Christine↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SRF e-beam accelerator for metal additive manufacturing

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

Thangaraj, Jayakar C.↗

SRF E - Beam Accelerator for Metal Additive Manufacturing [Patent]

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

43 PARTICLE ACCELERATORS↗

High-Entropy Alloy R&D for Accelerator Beam Window Applications

High-Entropy Alloys are a class of novel material that can offer improved resistance to beam-induced radiation damage and thermal shock. Development of these new alloys to serve as beam windows in multi-megawatt accelerator target applications is ongoing at Fermilab. Currently we are investigating AlCoCrMnTiV alloy systems of 4-6 components for service as beam windows; these compositions are predicted by CALPHAD simulation to have a low density and single-phase BCC crystal structure. The microstructures of these systems are being studied by electron microscopy techniques such as energy dispersive X-ray spectroscopy (EDS) to determine elemental homogeneity and composition, electron backscatter diffraction (EBSD) to quantify grain structure and orientation, and transmission electron microscopy (TEM) to observe defect structures and precipitate formation; nanoindentation is used to probe microstructural mechanical properties. Initial bulk property characterization utilizes differential scanning calorimetry to quantify specific heat capacity (cp), dilatometry to determine the coefficient of thermal expansion (CTE), and time-domain thermoreflectance (TDTR) to measure thermal conductivity (K). A miniature tensile testing apparatus is also being developed to test tensile properties. Post-irradiation examination is currently ongoing for several of these compositions that have been irradiated by low-energy ions to damage levels and at a temperature relevant to beam window applications at future next-generation accelerator facilities. This talk will briefly describe the alloy design and synthesis before going into more depth covering microstructural pre-characterization, and post-irradiation examination results from low-energy ion irradiated specimens. This will be followed by the plans for alloy down selection and future prototypic proton irradiations.

43 PARTICLE ACCELERATORS↗

Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al 11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al 11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗