Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “absorption coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

TRACER-MAP_2022_absorption_coefficient

Absorption coefficient for PM2.5 measured by the Tri-color Absorption Photometer averaged every 2 minutes for July-August 2022. The location of the measurement is indicated by latitude and longitude coordinates; TRACER-MAP included time at the AMF site in La Porte and additional sites around Houston. Three wavelengths are reported: 365, 520 and 640 nm. The AAE is also reported using the three wavelengths. The data is reported as 2 minute averages.

54 ENVIRONMENTAL SCIENCES↗

Use of radial symmetry for the calculation of cylindrical absorption coefficients and optimal capillary loadings

The problem of numerically evaluating absorption correction factors for cylindrical samples has been revisited using a treatment that fully takes advantage of the sample symmetry. It is shown that the path lengths for all points within the sample at all possible diffraction angles can be trivially determined once the angle-dependent distance distribution for a single line of points is calculated. This provides advantages in both computational efficiency and in gaining an intuitive understanding of the effects of absorption on diffraction data. A matrix of absorption coefficients calculated for µR products between 0 and 20 for diffraction angles θ D of 0° to 90° were used to examine the influence of (1) capillary diameter and of (2) sample density on the overall scattered intensity as a function of diffraction angle, where µ is the linear absorption coefficient for the sample and R is the capillary radius. Based on this analysis, the optimal sample loading for a capillary experiment to maximize diffraction at angles of 0 – 50° is in general expected to be achieved when the maximum radius capillary compatible with the beam is used, and when the sample density is adjusted to be 3/(4µR) of its original density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absorption of laser radiation in a H-He plasma. II - Experimental measurement of the absorption coefficient

The absorption coefficients of 0.633-, 1.15-, and 3.39-micron laser radiation for a homogeneous H-He plasma have been measured in the temperature range from 12.2 to 21.7 (x 1000 K) and in the electron number density range 0.45 to 6.5 (x 10 to the 17th power per cu cm). Good agreement is found between the experimentally determined total absorption for each of the wavelengths and that calculated from theory. Furthermore, because the 3.39-micron absorption is dominated by inverse bremsstrahlung, while the 0.633-micron absorption is dominated by photoionization and resonance absorption, the experiment indicates a correct assessment by the theory of these individual absorption mechanisms.

Billman, K. W.↗

Effect of applied mechanical stress on absorption coefficient of compounds

The absorption coefficient of given materials is the parameter required for the basic information. The measurement of absorption coefficient of compounds Al{sub 2}O{sub 3}, CaCO{sub 3}, ZnO{sub 2}, SmO{sub 2} and PbO has been taken at different incident photon energies 26, 59.54, 112, 1173, 1332keV. The studies involve the measurements of absorption coefficient of the self supporting samples prepared under different mechanical stress. This mechanical stress is render in terms of pressure up to 0-6 ton by using hydraulic press. Measurements shows that absorption coefficient of a material is directly proportional to applied mechanical stress on it up to some extent then become independent. Experimentally measured results are in fairly good agreement with in theoretical values obtained from WinXCOM.

36 MATERIALS SCIENCE↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Absorption Coefficient of Paraformaldehyde and Metaldehyde with Terahertz Spectroscopy

The characteristic absorption spectra of paraformaldehyde and metaldehyde in the terahertz frequency region are obtained by terahertz time-domain spectroscopy (THz-TDS). In order to reduce the absorption of terahertz (THz) wave by water vapor in the air and the background noise, the measurement system was filled with dry air and the measurements were conducted at the temperature of 24°C. Meanwhile, the humidity was controlled within 10% RH. The THz frequency domain spectra of samples and their references from 0 to 2.5 THz were analyzed via Fourier transform. The refractive index and absorption coefficients of the two aldehydes were calculated by the model formulas. From 0.1 to 2.5 THz, there appear two weak absorption peaks at 1.20 and 1.66 THz in the absorption spectra of paraformaldehyde. Only one distinct absorption peak emerges at 1.83 THz for metaldehyde. There are significant differences between the terahertz absorption coefficients of paraformaldehyde and metaldehyde, which can be used as 'fingerprints' to identify these substances. Furthermore, the relationship between the average absorption coefficients and mass concentrations was investigated and the average absorption coefficient–mass concentration diagrams of paraformaldehyde and metaldehyde were shown. For paraformaldehyde, there is a linear relationship between the average absorption coefficient and the natural logarithm of mass concentration. For metaldehyde, there exists a simpler linear relationship between the average absorption coefficient and the mass concentration. Because of the characteristics of THz absorption of paraformaldehyde and metaldehyde, the THz-TDS can be applied to the qualitative and quantitative detection of the two aldehydes to reduce the unpredictable hazards due to these substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of HCl absorption coefficients with a DF laser

Absorption coefficients in the fundamental P-branch of HCl at several DF laser transitions from 2439.02/cm to 2862.87/cm have been measured experimentally. The 2-1 P(3) DF laser transition has been shown to overlap the P(6) HCl-37 absorption line within the halfwidth of an atmospherically broadened line. The absorption coefficient k was measured to be 5.64 plus or minus 0.28/(atm-cm) for a 0.27% mixture of HCl in N2 at a total pressure of 760 torr. A theoretical and experimental comparison of the pressure dependence of k showed that the 2-1 P(3) DF transition lies 1.32 plus or minus 0.15 GHz from the center of the P(6) HCl absorption line. Applications of these results to differential absorption lidar and to heterodyne detection are discussed.

Bair, C. H.↗

Effect of quantum dot size and size distribution on the intersublevel transitions and absorption coefficients of III-V semiconductor quantum dot

The intersublevel absorption peak energy and absorption coefficient of non-uniform quantum dot (QD) ensembles are calculated analytically. The effect of size variations and size distribution of QDs on their energy states is analyzed. The dots are considered as a quantum box with finite potential at the barriers and the size distribution described by a Gaussian function. The influence of the aspect ratio (base to height ratio) of the QDs on the optical transitions is studied. Our model predicts the dot size (height and base) accurately to determine the absorption peaks and corresponding absorption coefficient. We also compute the absorption coefficient of the QD with different size distributions to verify the results calculated using this model with the reported experimental and other theoretical results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the absorption coefficient of acoustical materials using the sound intensity method

In this study the possibility of using the two-microphone sound intensity technique to measure the normal incidence and the random incidence sound absorption coefficient was investigated. The normal incidence absorption coefficient was determined by measuring the intensity incidence on the sample and the intensity reflected by the sample placed in an anechoic chamber. The random incidence absorption coefficient was determined by measuring the intensity incident on the sample and the intensity reflected by the sample placed in a reverberation chamber. Absorption coefficient results obtained by the sound intensity technique were compared with standard techniques, namely the reverberation chamber and the standing wave tube. The major advantages of using the sound intensity technique are that it permits 'in situ' measurements and the absorption coefficient for a large range of frequencies can be obtained from a single measurement.

Atwal, Mahabir S.↗

Mass energy-absorption coefficients and average atomic energy-absorption cross-sections for amino acids in the energy range 0.122-1.330 MeV

Mass attenuation coefficients of amino acids such as n-acetyl-l-tryptophan, n-acetyl-l-tyrosine and d-tryptophan were measured in the energy range 0.122-1.330 MeV. NaI (Tl) scintillation detection system was used to detect gamma rays with a resolution of 8.2% at 0.662 MeV. The measured attenuation coefficient values were then used to determine the mass energy-absorption coefficients (σ{sub a,en}) and average atomic energy-absorption cross sections (μ{sub en}/ρ) of the amino acids. Theoretical values were calculated based on XCOM data. Theoretical and experimental values are found to be in good agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of NH3 absorption coefficients with a C-13/O-16/2 laser

Measurements of NH3 absorption coefficients are presented for several transitions of a C-13(O-16)2 laser for small concentrations of NH3(p less than 1 torr) for absorption lines broadened to 1 atm with N2. NH3 absorption coefficients were determined for laser transitions R(8)(920.2194 wavelengths/cm) to R(28)(933.8808 wavelengths/cm) of the 00 1 - (10 0,02 0)I band. The strongest absorption coefficient K = 36.09 + or - 1.43 per (atm-cm) was measured for the R(18) transition for the NH3 line, aQ(6,6), and is larger than has been found in any previous measurements with a CO2 laser. The dependence of K on total pressure was also obtained for select transitions, and the frequency separation between the R(18) laser transition and the neighboring NH3 line aQ(6,6) was determined to be 550 + or - 50 MHz. These results are significant for long path absorption monitoring of NH3 with CO2 lasers since the path length can be reduced by approximately 40% and for heterodyne detection of NH3 since the relative position of the laser transition to the NH3 absorption line is well within the bandpass of Hg-Cd-Te photomixers.

Allario, F.↗

Temperature and pressure dependence of dichloro-difluoromethane (CF2C12) absorption coefficients for CO2 waveguide laser radiation

Measurements were performed to determine the pressure and temperature dependence of CFM-12 absorption coefficients for CO2 waveguide laser radiation. The absorption coefficients of CFM-12 for CO2 waveguide laser radiation were found to have no spectral structure within small spectral bandwidths around the CO2 waveguide laser lines in the CO2 spectral band for pressures above 20 torr. All of the absorption coefficients for the CO2 laser lines studied are independent of pressure above 100 torr, except for the P(36) laser CO2 spectral band. The absorption coefficients associated with the P(42) line in the same band showed the greatest change with temperature, and it also has the largest value of all the lines studied.

Harward, C. N.↗

IPN Absorption Coefficients

The dataset contains aerosol light absorption and scattering coefficients measured by three single-wavelength Integrated Photoacoustic Nephelometers (IPN). The absorption coefficients were measured at 405, 721, and 1047 nm, while the scattering coefficients were measured at 405 and 721 nm. The single scattering albedo (SSA) at 405 and 721 nm were also calculated from the IPN measurements. The three IPNs shared a common inlet without impactor/cyclone in July; in August, a PM2.5 cyclone inlet was installed to reduce measurement noise and improve data quality. The 721-nm IPN experienced laser shutdown issues, causing missing of a large fraction of the 721-nm measurements, especially in July. As described before, the 721-nm laser issue was less frequent in August after the cyclone installation, improving the data completeness and quality. The IPN raw data were noisy, making identifying patterns and trends difficult; therefore, the hourly average data are recommended over the raw data. The hourly average data were cross-checked with the filter-based TAP and PSAP measurements, which showed that their patterns, trends, and peaks matched. However, due to the differences in working mechanisms and principles of the filter-based and photoacoustic particle-phase instruments, the IPN measurements are lower than the filter-based measurements despite that they have consistent patterns, trends, and peaks.

54 ENVIRONMENTAL SCIENCES↗

Measurements of the absorption coefficient of stratospheric aerosols

The absorption coefficients of stratospheric aerosols are measured using a variation on the integrating plate method. The technique is based on the decrease in the transparency of a substrate when an absorbing aerosol is deposited on it. A Lambert scatterer is placed behind the substrate to integrate forward scattered light and minimize the effect of scattering on the measurement. The low pressure in the stratosphere is used for the direct impaction of particles onto a narrow strip of opal glass. The eight samples collected had a median value of 4 x 10 to the -9th m with an uncertainty of + or - 5 x 10 to the -9th m. If this absorption is due to graphitic carbon, then its concentration is estimated at about 0.4 ng/cu m, or about 0.25% of the total aerosol mass concentration. Estimates of the aerosol scattering coefficients based on satellite extinction inversions result in an aerosol single-scattering albedo in the range of 0.96-1.0.

Ogren, J. A.↗