Engineering PapersSearch

SEARCH · Engineering Papers

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY

Characterizing Absolute Orientations in DNA Self-Assembly of Single Molecules

DNA self-assembly of single molecules (i.e., dyes) with deterministic orientations is a powerful approach for engineering mo-lecular excitons. However, current determination methods of the dye orientation relative to DNA do not account for the orien-tation of the dye plane, which is a missing degree of freedom needed to define absolute three-dimensional orientations. In this work, we combine fluorescence-detected linear dichroism, defocused dipole imaging, and DNA points accumulation for imaging in nanoscale topography (DNA-PAINT) super-resolution microscopy to determine the absolute three-dimensional orientations of single Cy5 dyes relative to host DNA duplexes which includes the dye plane orientation. The data revealed that the absorption and emission dipoles are perpendicular to the DNA duplex, and the mean dye plane is parallel to the DNA bases, which supports the notion that Cy5 dyes intercalate between DNA base pairs. The presented methodology will inspire the investigation of the dye plane orientation for controlling dye arrangement configurations beyond spontaneous π-stacking between dyes as well as achieving novel dye-DNA arrangements.

36 MATERIALS SCIENCE

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N

Absolute nuclear charge radius by Na-like spectral line separation in high-Z elements

Abstract We describe a novel technique to determine absolute nuclear radii of high- Z nuclides. Utilizing accurate theoretical atomic structure calculations together with precise measurements of extreme ultraviolet transitions in highly charged ions this method allows for precise determinations of absolute nuclear charge radii based upon the well-known nuclear radii of their neighboring elements. This method can work for elements without stable isotopes, and its accuracy may be competitive with current methods (electron scattering and muonic x-ray spectroscopy).

Hosier, A. (ORCID:0000000328366605)

Absolute Efficiency Characterization of Neutron Detectors within Radioisotope Identification Devices [Slides]

Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.

Nuclear Criticality Safety Program (NCSP)

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS

Beyond $Δm^2$: Absolute Mass Sensitivity in Neutrino Oscillations

Conventional wisdom says that neutrino oscillations measure only mass-squared differences and not the absolute neutrino mass scale. This is true, however, only at leading order in the expansion parameters $m_i/E$, the ratios of the neutrino masses $m_i$ ($i=1,2,3$) to the neutrino energy $E$. At next-to-leading order, the oscillation phase includes terms proportional to $m_i^4-m_j^4 = Δm^2_{ij}(m_i^2+m_j^2)$, and is therefore sensitive to the absolute mass scale. In this paper, we derive the next-to-leading-order corrections using a wave-packet treatment and taking into account the neutrino-production kinematics. We then apply this result to reactor antineutrinos and find that the JUNO experiment is sensitive to neutrino masses of a few hundred keV. While not competitive with existing bounds from beta decay, electron capture, and cosmology, neutrino oscillations provide a novel, complementary probe of the neutrino mass scale, with sensitivity to a different combination of neutrino masses.

Alves, Gustavo F.S. [Fermilab; Argonne; Northweste

Two-dimensional mapping of absolute OH densities in an atmospheric pressure plasma effluent via planar laser-induced fluorescence: effects of He/H 2 O and He/O 2 mixtures in N 2 and air, with and without solid targets

Planar laser-induced fluorescence (LIF) was employed to measure the absolute density of hydroxyl radicals (OH) in the effluent of the COST Reference Microplasma Jet for two feed gas mixtures: He/H 2 O and He/O 2 . Experiments were conducted with the effluent propagating into air and N 2 environments. For the He/H 2 O case, measurements were also performed with the effluent impinging on a solid target at varying distances from the jet nozzle. Calibration of the OH-LIF signal from the COST-Jet was achieved by comparing it to a reference signal generated by the photofragmentation of H 2 O 2 . Results demonstrated that OH densities were sustained longer when the effluent propagates in a nitrogen environment compared to air, particularly with water added to the feed gas. The broader OH distribution in N 2 suggests slower consumption due to the absence of oxygen, which accelerates OH depletion in air via reactions involving O 2 and HO 2 . Even when water was not added to the feed, as in the He/O 2 case, appreciable OH densities were observed, due to gas impurities and reactive species interactions with atmospheric humidity, forming reaction fronts that delineate the gas flow. Two-dimensional fluid dynamics simulations elucidated the influence of atmospheric gas entrainment and solid targets on the OH distribution. Experimental trends were further compared with a zero-dimensional chemistry model to explore OH production and consumption mechanisms in air and nitrogen environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Absolute photoionization cross sections of brominated organics and determination of an effective C—Br bond cross section

For this work, absolute photoionization cross sections for five brominated species were measured using multiplexed synchrotron photoionization mass spectrometry at the Advanced Light Source (Lawrence Berkeley National Laboratory). These data enable reliable detection of bromine-containing compounds and estimation of C—Br bond photoionization cross sections. Complementary electronic-structure calculations provided adiabatic ionization energies in good agreement with experiment, while thermochemical appearance energies were measured directly. Bond dissociation energies for key fragmentation pathways of the neutral parent molecules were also analyzed. At 11 eV, cross sections were 53.8 ± 7.50 Mb (sp 2 C—Br) and 48.8 ± 7.70 Mb (sp 3 C—Br).

Brominated compounds

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy

Helium metastable density determination in the COST reference source by absolutely calibrated optical emission spectroscopy

Helium metastable densities in the COST Reference Microplasma Jet are estimated for a variety of He/N2 admixtures and dissipated powers by applying a collisional-radiative model to absolutely calibrated optical emission spectroscopy measurements. This is accomplished by delineating the excitation mechanisms that result in the N2(C–B) and N2+(B–X) emission bands, the latter of which is strongly coupled to the presence of helium metastables. A number of other plasma parameters are established and discussed for each operating condition including the electron energy distribution function, reduced electric field, rate constants, and electron density. With these parameters, the reaction rates for the primary ionization pathways are also calculated, emphasizing the importance of helium metastables for discharge sustainment. Good agreement with the existing literature is found for most plasma parameters and for helium metastable densities, in particular. A clear [N2]−1 relationship between the nitrogen concentration and density of helium metastables is demonstrated, as has been identified in previous studies in analogous atmospheric pressure plasma jets. This validates the efficacy of this optical technique for determining helium metastable densities and establishes it as a viable, and in many cases, more accessible alternative to other means of quantifying helium metastables in low-temperature plasmas.

Physics

Absolute Hugoniot measurements in low-density plastic foams on the NIKE shock compression platform

The propagation of Mbar-range shock waves in low-density foam materials is of interest to target design in all approaches to inertial confinement fusion, high energy density physics, and laboratory astrophysics. We report absolute Hugoniot measurements for CH 1.72 N 0.086 O 0.37 plastic foams with 73 and 94 mg/cm 3 densities in the 32–107 km/s shock velocity range. The experiments were performed on the shock compression platform developed on the NIKE KrF laser facility at the U.S. Naval Research Laboratory. NIKE's 4 or 8-ns long flat-top laser pulses drive steady shock waves into foam targets at the ablative pressures of 1–7 Mbar. The propagation of the ablation and shock fronts is tracked continuously in time using streaked side-on monochromatic x-ray imaging radiography. The straight x−t trajectories of the shock and ablation fronts in the recorded streak images confirmed their steadiness. The SESAME tabulated equation of state predictions generally agrees with our Hugoniot data within a 95% confidence band. The experimental uncertainty of the evaluated shock density compression ratios remains large, indicating the need for more experiments and improved theoretical understanding of the strong shock propagation mechanisms in dry foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

On the origins of the continuum radiation of an underwater nanosecond pulsed discharge: an absolute-intensity optical emission spectroscopy study

The plasma properties of an underwater nanosecond pulsed discharge remain not fully understood despite being extensively studied for several decades. In this work, we focus on the continuum radiation generated in such discharges. The discharge is characterized by power measurements as well as by absolute emission spectroscopy. When observed, Stark broadenings of H α , H β and O (777 nm) are employed for electron number densities measurements. The discharge was generated by a 10 ns main voltage pulse followed by multiple secondary pulses, which last up to 4 μs after the primary pulse. It is shown that a peak power of 3.5 MW and energy of 35 mJ is coupled during the main voltage pulse. A quantitative estimation of the different possible continuum radiation sources is performed through analytical calculations. This includes emission (blackbody, free–bound and free–free bremsstrahlung radiations) and absorption (electron–ion and electron–neutral free–free inverse bremsstrahlung) mechanisms. Our results suggest that electron–neutral free–free bremsstrahlung is the principal mechanism responsible for the strong continuum radiation observed experimentally during the primary pulse. We also show that self-absorption through electron–neutral (and electron–ion) inverse bremsstrahlung plays an important role in the main discharge pulse. Further, our results indicate the non-negligible additional contribution of the H 2 continuum during the first reflected pulse which is likely ignited in bubbles generated by the first discharge pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Calibrating the absolute magnitude of type Ia supernovae in nearby galaxies using [O II ] and implications for H 0

The present state of cosmology is facing a crisis where there is a fundamental disagreement in measurements of the Hubble constant ($H_{0}$), with significant tension between the early and late Universe methods. Type Ia supernovae (SNe Ia) are important to measuring $H_{0}$ through the astronomical distance ladder. However, there remains potential to better standardize SN Ia light curves by using known dependencies on host galaxy properties after the standard light curve width and colour corrections have been applied to the peak SN Ia luminosities. To explore this, we use the 5-yr photometrically identified SNe Ia sample obtained by the Dark Energy Survey, along with host galaxy spectra obtained by the Australian Dark Energy Survey. Using host galaxy spectroscopy, we find a significant trend with the equivalent width (EW) of the [O II ] $\lambda \lambda$ 3727, 29 doublet, a proxy for specific star formation rate, and Hubble residuals. We find that the correlation with [O II ] EW is a powerful alternative to the commonly used mass step after initial light-curve corrections. Applying this [O II ] EW correction to 20 SNe Ia in calibrator galaxies observed with WiFeS, we examined the impact on SN Ia absolute magnitudes and $H_{0}$. Our [O II ] EW corrections result in $H_{0}$ values ranging between 73.04 and 73.51 $km$ $s^{-1} \, Mpc^{-1}$, with a combined statistical and systematic uncertainty of $\sim 1.31$ $km$ $s^{-1} \, Mpc^{-1}$. However, even with this additional correction, the impact of host galaxy properties in standardizing SNe Ia appears limited in reducing the current tension ($\sim 5\sigma$) with the cosmic microwave background result for $H_{0}$.

79 ASTRONOMY AND ASTROPHYSICS

Towards absolutely stable ergodicity breaking in two and three dimensions

We propose physically reasonable systems capable of avoiding ergodicity at infinite time in the thermodynamic limit, even with generic perturbations and when coupled to a heat bath. In two dimensions, the rainbow loop soup has (stretched) exponentially numerous absolutely stable nonergodic states with diverging energy but vanishing energy density. In three dimensions the rainbow membrane soup has (stretched) exponentially numerous nonergodic states with diverging energy barriers, leading to infinite-time robust ergodicity breaking that even survives coupling to a nonzero temperature heat bath. We describe our results in the language of exact emergent symmetries and demonstrate how the systems avoid common instabilities. Furthermore, our construction naturally connects to quantum dimer models, topologically ordered systems, the group word construction, and Hamiltonians whose low-energy eigenstates exhibit anomalous entanglement entropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics