Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Zernike phase-contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Large-field high-contrast hard x-ray Zernike phase-contrast nano-imaging beamline at Pohang Light Source

We developed an off-axis-illuminated zone-plate-based hard x-ray Zernike phase-contrast microscope beamline at Pohang Light Source. Owing to condenser optics-free and off-axis illumination, a large field of view was achieved. The pinhole-type Zernike phase plate affords high-contrast images of a cell with minimal artifacts such as the shade-off and halo effects. The setup, including the optics and the alignment, is simple and easy, and allows faster and easier imaging of large bio-samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/diameter) of the PSF which is intermediate between the input and output plane. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective, and second the phase shift in the central core of the PSF is dynamic and can be made arbitrarily large. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument.

Zernike phase-contrast↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique1,2,3,4 transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/D) of the PSF which is intermediate between the input and output planes. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective. Second, the phase shift in the central core of the PSF is dynamic and or arbitrary size. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument

wavefront sensing↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Analysis of the process of visualisation of transparent objects using the phase-contrast method with a photothermal Zernike cell

Basic characteristics of the process of visualisation of transparent objects using the phase-contrast method with a photothermal Zernike cell are analysed and evaluated. It is shown that, in spite of nonlocality of the process, visualisation is accomplished with the resolution close to the diffraction limit. The results of the visualisation process analysis in the scheme with a photothermal sell are compared with those obtained in a similar scheme with a Zernike cell based on the local Kerr nonlinearity. (optical image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-imaging of transparent objects and structures in focusing of spatially phase-modulated laser radiation into a weakly absorbing medium

Self-imaging of transparent objects and structures in focusing of a spatially phase-modulated laser beam into an extended weakly absorbing medium is described. The laser power level that is necessary for effective imaging corresponds to the illuminating beam power when thermal self-defocusing starts evolving in the medium. The effect can be described in terms of the ideology of Zernike's classical phase-contrast method. Edge enhancement in visualised images of transparent objects is experimentally demonstrated. Self-imaging of a microscopic object in the form of transparent letters and long-lived refractive-index fluctuations in liquid glycerol is shown. Due to the adaptivity of the process under consideration, unlike the classical case, self-imaging occurs also in the situations where a beam is displaced (undergoes random walk) as a whole in the Fourier plane, for example, in the presence of thermal flows. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Simple Interferometer for Obtaining Quantitatively Evaluable Flow Patterns

The method described in the present report makes it possible to obtain interferometer records with the aid of any one of the available Schlieren optics by the addition of very simple expedients, which fundamentally need not to be inferior to those obtained by other methods, such as the Mach-Zehnder interferometer, for example. The method is based on the fundamental concept of the phase-contrast process developed by Zernike, but which in principle has been enlarged to such an extent that it practically represents an independent interference method for general applications. Moreover, the method offers the possibility, in case of necessity, of superposing any apparent wedge field on the density field to be gauged. The theory is explained on a purely physical basis and illustrated and proved by experimental data. A number of typical cases are cited and some quantitative results reported.

INSTRUMENTS - INTERFEROMETERS↗

Reflective Phase-Contrast for High-Contrast Imaging of van der Waals Heterostructure

Optical microscopy plays a critical role in the fabrication of two-dimensional (2D) van der Waals heterostructures. An outstanding challenge in conventional microscopy is to visualize transparent 2D layers as well as embedded monolayers in a stacked heterostructure with high optical contrast. Phase-contrast microscopy, first developed by Frits Zernike in the 1930s, leverages the interference effect between specimen scattered light and background light to increase the contrast of transparent specimens. Such phase-contrast microscopy, always in a transmission configuration, revolutionized the study of transparent cellular structures in biology. Here, we develop a versatile reflective phase-contrast microscopy for imaging 2D heterostructures. We employ two spatial light modulators to flexibly control the intensity and phase of the illumination and the reflected light. This reflective phase-contrast microscopy achieves unprecedented high contrast for imaging a transparent 2D monolayer. In conclusion, it also enables direct observation of 2D monolayers embedded inside a thick heterostructure that are "invisible" in conventional microscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Holographic Imaging of Evolving Laser-Plasma Structures

In the 1870s, English photographer Eadweard Muybridge captured motion pictures within one cycle of a horse’s gallop, which settled a hotly debated question of his time by showing that the horse became temporarily airborne. In the 1940s, Manhattan project photographer Berlin Brixner captured a nuclear blast at a million frames per second, and resolved a dispute about the explosion’s shape and speed. In this project, we developed methods to capture detailed motion pictures of evolving, light-velocity objects created by a laser pulse propagating through matter. These objects include electron density waves used to accelerate charged particles, laser-induced refractive index changes used for micromachining, and ionization tracks used for atmospheric chemical analysis, guide star creation and ranging. Our “movies”, like Muybridge’s and Brixner’s, are obtained in one shot, since the laser-created objects of interest are insufficiently repeatable for accurate stroboscopic imaging. Our high-speed photographs have begun to resolve controversies about how laser-created objects form and evolve, questions that previously could be addressed only by intensive computer simulations based on estimated initial conditions. Resolving such questions helps develop better tabletop particle accelerators, atmospheric ranging devices and many other applications of laser-matter interactions. Our photographic methods all begin by splitting one or more “probe” pulses from the laser pulse that creates the light-speed object. A probe illuminates the object and obtains information about its structure without altering it. We developed three single-shot visualization methods that differ in how the probes interact with the object of interest or are recorded. (1) Frequency-Domain Holography (FDH). In FDH, there are 2 probes, like “object” and “reference” beams in conventional holography. Our “object” probe surrounds the light-speed object, like a fleas swarming around a sprinting animal. The object modifies the probe, imprinting information about its structure. Meanwhile, our “reference” probe co-propagates ahead of the object, free of its influence. After the interaction, object and reference combine to record a hologram. For technical reasons, our recording device is a spectrometer (a frequency-measuring device), hence the name “frequency-domain” holography. We read the hologram electronically to obtain a “snapshot” of the object’s average structure as it transits the medium. Our published work shows numerous snapshots of electron density waves (“laser wakes”) in ionized gas (“plasma”), analogous to a water wake behind a boat. Such waves are the basis of tabletop particle accelerators, in which charged particles surf on the light-speed wave, gaining energy. Comparing our snapshots to computer simulations deepens understanding of laser wakes. FDH takes snapshots of objects that are quasi-static --- i.e. like Muybridge’s horse standing still on a treadmill. If the object changes shape, FDH images blur, as when a subject moves while a camera shutter is open. Many laser-generated objects of interest do evolve as they propagate. To overcome this limit of FDH, we developed .... (2) Frequency-Domain Tomography (FDT). In FDT, 5 to 10 probe pulses are fired simultaneously across the object’s path at different angles, like a crossfire of bullets. The object imprints a “streaked” record of its evolution on each probe, which we record as in FDH, then recover a multi-frame “movie” of the object’s evolving structure using algorithms of computerized tomography. When propagation distance exceeds a few millimeters, reconstructed FDT images distort. This is because the lenses that image probes to detector have limited depth of field, like cameras that cannot focus simultaneously on both nearby and distant objects. But some laser-generated objects of interest propagate over meters. For these applications we developed … (3) Multi-Object-Plane Phase-Contrast Imaging (MOP-PCI). In MOP-PCI, we image FDT-like probes to the detector from multiple “object planes” --- like recording an event simultaneously with several cameras, some focused on nearby, others on distant, objects. To increase sensitivity, we exploit a phase-contrast imaging technique developed by Dutch Nobel laureate Fritz Zernike in the 1930s. Using MOP-PCI we recorded single-shot movies of laser pulse tracks through more than 10 cm of air. We plan to record images of meter-long tracks of electron bunches propagating through plasma in an experiment at the Stanford Linear Accelerator Center (SLAC). This will help SLAC scientists understand, optimize and scale small plasma-based particle accelerators that have applications in medicine, industry, materials science and high-energy physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zernike Wavefront Sensor Modeling Development for LOWFS on WFIRST-AFTA

WFIRST-AFTA design makes use of an existing 2.4m telescope for direct imaging of exoplanets. To maintain the high contrast needed for the coronagraph, wavefront error (WFE) of the optical system needs to be continuously sensed and controlled. Low Order Wavefront Sensing (LOWFS) uses the rejected starlight from an immediate focal plane to sense wavefront changes (mostly thermally induced low order WFE) by combining the LOWFS mask (a phase plate located at the small center region with reflective layer) with the starlight rejection masks, i.e. Hybrid Lyot Coronagraph (HLC)'s occulter or Shaped Pupil Coronagraph (SPC)'s field stop. Zernike wavefront sensor (ZWFS) measures phase via the phase-contrast method and is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIST/AFTA for its good sensitivity, accuracy, and its easy integration with the starlight rejection mask. In this paper, we review the theory of ZWFS operation, describe the ZWFS algorithm development, and summarize various numerical sensitivity studies on the sensor performance. In the end, the predicted sensor performance on SPC and HLC configurations are presented.

Zernike phase contrast↗

RESTORATION OF WEAK PHASE-CONTRAST IMAGES RECORDED WITH A HIGH DEGREE OF DEFOCUS: THE"TWIN IMAGE" PROBLEM ASSOCIATED WITH CTF CORRECTION

Relatively large values of objective-lens defocus must normally be used to produce detectable levels of image contrast for unstained biological specimens, which are generally weak phase objects. As a result, a subsequent restoration operation must be used to correct for oscillations in the contrast transfer function (CTF) at higher resolution. Currently used methods of CTF-correction assume the ideal case in which Friedel mates in the scattered wave have contributed pairs of Fourier components that overlap with one another in the image plane. This"ideal" situation may be only poorly satisfied, or not satisfied at all, as the particle size gets smaller, the defocus value gets larger, and the resolution gets higher. We have therefore investigated whether currently used methods of CTF correction are also effective in restoring the single-sideband image information that becomes displaced (delocalized) by half (or more) the diameter of a particle of finite size. Computer simulations are used to show that restoration either by"phase flipping" or by multiplying by the CTF recovers only about half of the delocalized information. The other half of the delocalized information goes into a doubly defocused"twin" image of the type produced during optical reconstruction of an in-line hologram. Restoration with a Wiener filter is effective in recovering the delocalized information only when the signal-to-noise ratio (S/N) is orders of magnitude higher than that which exists in low-dose images of biological specimens, in which case the Wiener filter approaches division by the CTF (i.e. the formal inverse). For realistic values of the S/N, however, the"twin image" problem seenwith a Wiener filter is very similar to that seen when either phase flipping or multiplying by the CTF are used for restoration. The results of these simulations suggest that CTF correction is a poor alternative to using a Zernike-type phase plate when imaging biological specimens, in which case the images can be recorded in a close-to-focus condition, and delocalization of high-resolution information is thus minimized.

59 BASIC BIOLOGICAL SCIENCES↗

A method for measuring the nonlinear refractive index from the contrast of an amplitude object image in the optical scheme with phase Zernike filters based on electronic Kerr nonlinearity

We propose a method for determining the nonlinear refractive index from the image contrast of amplitude objects in the phase-contrast scheme with a sample acting as a phase Zernike filter based on the electronic Kerr nonlinearity. This method implies the measurement of the calibration dependence of the contrast of an amplitude object image on the laser pulse energy for a test sample with a known nonlinearity and makes it possible to find the nonlinear refractive index of samples under study using a single laser pulse. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗