Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YTTRIUM 82”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=82☆

The evaluators present in this publication spectroscopic data and level schemes from radioactive decay and nuclear reactions studies for all isobars, Z=28(Ni) to Z=42(Mo), with mass number A=82. For {sup 82}Ni not much is known other than its identification. Most of the new data, i.e., after the last NDS (2003Tu03), are based on compilations included in XUNDL. Contributions of the various compilers in XUNDL are gratefully acknowledged.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms

Purpose: Positron emission tomography (PET) plays an important role in the diagnosis, staging, treatment, and surveillance of clinically localized diseases. Combined PET/CT imaging exhibits significantly higher sensitivity, specificity, and accuracy than conventional imaging when it comes to detecting malignant tumors in children. However, the radiation dose from positron-emitting radionuclide to the pediatric population is a matter of concern since children are at a particularly high risk when exposed to ionizing radiation.Methods: The authors evaluate the absorbed fractions and specific absorbed fractions (SAFs) of monoenergy photons/electrons as well as S-values of 9 positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124) in 48 source regions for 10 anthropomorphic pediatric hybrid models, including the reference newborn, 1-, 5-, 10-, and 15-yr-old male and female models, using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code.Results: The self-absorbed SAFs and S-values for most organs were inversely related to the age and body weight, whereas the cross-dose terms presented less correlation with body weight. For most source/target organ pairs, Rb-82 and Y-86 produce the highest self-absorbed and cross-absorbed S-values, respectively, while Cu-64 produces the lowest S-values because of the low-energy and high-frequency of electron emissions. Most of the total self-absorbed S-values are contributed from nonpenetrating particles (electrons and positrons), which have a linear relationship with body weight. The dependence of self-absorbed S-values of the two annihilation photons varies to the reciprocal of 0.76 power of the mass, whereas the self-absorbed S-values of positrons vary according to the reciprocal mass.Conclusions: The produced S-values for common positron-emitting radionuclides can be exploited for the assessment of radiation dose delivered to the pediatric population from various PET radiotracers used in clinical and research settings. The mass scaling method for positron-emitters can be used to derive patient-specific S-values from data of reference phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

{gamma}-ray spectroscopy of the neutron-rich nuclei {sup 89}Rb, {sup 92}Y, and {sup 93}Y with multinucleon transfer reactions

The positive-parity yrast states in the {sup 89}Rb, {sup 92}Y, and {sup 93}Y nuclei were studied using {gamma}-ray spectroscopy with heavy-ion induced reactions. In the multinucleon transfer reactions {sup 208}Pb+{sup 90}Zr (590 MeV) and {sup 238}U+{sup 82}Se (505 MeV), several {gamma}-ray transitions were identified in these nuclei by means of coincidences between recoiling ions identified with the PRISMA spectrometer and {gamma} rays detected with the CLARA {gamma}-ray array in thin target experiments. Level schemes were subsequently determined from triple-{gamma} coincidences recorded with the GASP array in a thick target experiment, in the reactions produced by a 470 MeV {sup 82}Se beam with a {sup 192}Os target. The observed level schemes are compared to shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of respiratory motion on internal radiation dosimetry

Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences the absorbed dose for external exposure to radiation. However, to their knowledge, the effect of respiratory motion on internal radiation dosimetry has never been reported before. Methods: Thirteen computational models representing the adult male at different respiratory phases corresponding to the normal respiratory cycle were generated from the 4D dynamic XCAT phantom. Monte Carlo calculations were performed using the MCNP transport code to estimate the specific absorbed fractions (SAFs) of monoenergetic photons/electrons, the S-values of common positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124), and the absorbed dose of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) in 28 target regions for both the static (average of dynamic frames) and dynamic phantoms. Results: The self-absorbed dose for most organs/tissues is only slightly influenced by respiratory motion. However, for the lung, the self-absorbed SAF is about 11.5% higher at the peak exhale phase than the peak inhale phase for photon energies above 50 keV. The cross-absorbed dose is obviously affected by respiratory motion for many combinations of source-target pairs. The cross-absorbed S-values for the heart contents irradiating the lung are about 7.5% higher in the peak exhale phase than the peak inhale phase for different positron-emitting radionuclides. For {sup 18}F-FDG, organ absorbed doses are less influenced by respiratory motion. Conclusions: Respiration-induced volume variations of the lungs and the repositioning of internal organs affect the self-absorbed dose of the lungs and cross-absorbed dose between organs in internal radiation dosimetry. The dynamic anatomical model provides more accurate internal radiation dosimetry estimates for the lungs and abdominal organs based on realistic modeling of respiratory motion. This work also contributes to a better understanding of model-induced uncertainties in internal radiation dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A trid(alkyl)yttrium compound cotaining six beta-agostic Si-H interactions

The new homoleptic rare earth compound [Y(C(SiHMe{sub 2}){sub 3}){sub 3}] ( 2) is prepared in 82% yield by salt metathesis of YCl{sub 3} and 3 equivalents of [KC(SiHMe{sub 2}){sub 3}] (1); two {beta}-agostic Y...(H-Si) interactions are observed for each C(SiHMe{sub 2}){sub 3} ligand in 2, giving six agostic interactions per yttrium(III) center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE UBIQUITY OF THE RAPID NEUTRON-CAPTURE PROCESS

To better characterize the abundance patterns produced by the r-process, we have derived new abundances or upper limits for the heavy elements zinc (Zn, Z= 30), yttrium (Y, Z= 39), lanthanum (La, Z= 57), europium (Eu, Z= 63), and lead (Pb, Z= 82). Our sample of 161 metal-poor stars includes new measurements from 88 high-resolution and high signal-to-noise spectra obtained with the Tull Spectrograph on the 2.7 m Smith Telescope at the McDonald Observatory, and other abundances are adopted from the literature. We use models of the s-process in asymptotic giant branch stars to characterize the high Pb/Eu ratios produced in the s-process at low metallicity, and our new observations then allow us to identify a sample of stars with no detectable s-process material. In these stars, we find no significant increase in the Pb/Eu ratios with increasing metallicity. This suggests that s-process material was not widely dispersed until the overall Galactic metallicity grew considerably, perhaps even as high as [Fe/H] =-1.4, in contrast with earlier studies that suggested a much lower mean metallicity. We identify a dispersion of at least 0.5 dex in [La/Eu] in metal-poor stars with [Eu/Fe] <+0.6 attributable to the r-process, suggesting that there is no unique 'pure' r-process elemental ratio among pairs of rare earth elements. We confirm earlier detections of an anti-correlation between Y/Eu and Eu/Fe bookended by stars strongly enriched in the r-process (e.g., CS 22892-052) and those with deficiencies of the heavy elements (e.g., HD 122563). We can reproduce the range of Y/Eu ratios using simulations of high-entropy neutrino winds of core-collapse supernovae that include charged-particle and neutron-capture components of r-process nucleosynthesis. The heavy element abundance patterns in most metal-poor stars do not resemble that of CS 22892-052, but the presence of heavy elements such as Ba in nearly all metal-poor stars without s-process enrichment suggests that the r-process is a common phenomenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 93

Nuclear structure data pertaining to all nuclei with mass number A=93 (Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru, Rh, Pd, Ag) have been compiled and evaluated and incorporated into the ENSDF data file. This publication for A=93 supersedes the previous publication by C.M. Baglin, Nuclear Data Sheets80, 1 (1997) (literature cutoff date November 1996) and subsequent revisions by C.M. Baglin of the ENSDF files for 93Br and {sup 93}Kr (literature cutoff 26 February 2001) and for {sup 93}Rh (literature cutoff 27 February 2001); it includes all data available prior to 15 December 2010. Significant changes since prior evaluations include the following: 2010Hw03 identified several high-spin states in {sup 93}Kr in {sup 252}Cf SF decay; in addition to the many low-spin levels already known in {sup 93}Rb from {beta}{sup -} decay, several higher-spin states have now been identified in a {sup 252}Cf SF decay study (2009Hw03); this SF decay has also been used to identify additional states in {sup 93}Sr (2003Hw01) and the {sup 238}U({sup 82}Se,X{gamma}) reaction (2007Bu35) has provided new information on {sup 93}Y. (HI,xn{gamma}) reaction studies have expanded our knowledge of the structure of {sup 93}Zr (2002Fo03, 2005Pa48), {sup 93}Nb (2007Wa45), {sup 93}Mo (2005Fu01), {sup 93}Tc (2003Ha22) and {sup 93}Pd (2004So04,2004Ru02). Considerable information on {sup 93}Nb was provided by a (p,2n{gamma}) study (2010Or01, 2006Or09, 2007Or01). The level schemes of {sup 93}Ru, {sup 93}Rh and {sup 93}Pd have undergone the most extensive revision thanks to studies of {sup 93}Rh {epsilon} decay (2004De40), {sup 94}Ag {epsilon}p decay (2004Mu30) and {sup 94}Ag p decay (2005Mu15, 2005Mu30), respectively. The half-life of the Zr member of this chain is of particular interest because of {sup 93}Zr's large contribution to long-term activity of nuclear reactor waste and also due to its potential as a supernova chronometer. During 2010, two new well-documented measurements of T{sub 1/2}({sup 93}Zr) were published (2010Ya01 and 2010Ca01); one agrees well with an earlier, undocumented measurement but, unfortunately, the other is many standard deviations lower for reasons which are not immediately apparent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Cone-Beam Tomography and Cross-Sectional Imaging for Volumetric and Dosimetric Calculations in Resin Yttrium-90 Radioembolization

PurposeTo compare the use of cone-beam computed tomography versus contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) in the calculation of liver volume and planned dose for yttrium-90 radioembolization.Materials and MethodsThe study retrospectively assessed 47 consecutive patients who underwent resin Y-90 radioembolization consecutively over a 2-year period at a single center. Volume calculation software was used to determine perfused lobar liver volumes from cone-beam CT (CBCT) images obtained during mapping angiography. CBCT-derived volumes were compared with perfused lobar volume derived from contrast-enhanced CT and MRI. Nominal activities as determined by the SIR-Spheres Microspheres Activity Calculator were similarly calculated and compared using both CBCT and conventionally acquired volumes.ResultsA total of 82 hepatic lobes were assessed in 47 patients. The mean percentage difference between combined CT-MRI- and CBCT-derived calculated lobar volumes was 25.3% (p = 0.994). The mean percentage difference in calculated dose between the two methods was 21.8 ± 24.6% (p = 0.42). Combined left and right lobar CT-derived dose difference was less than 10% in 22 lobes, between 10 and 25% in 20 lobes, between 25 and 50% in 13 lobes and greater than 50% in 5 lobes. Combined left and right lobar MRI-derived dose difference was less than 10% in 11 lobes, between 10 and 25% in 7 lobes, between 25 and 50% in 2 lobes and greater than 50% in 1 lobe.ConclusionsAlthough volume measurements derived from CT/MRI did not differ significantly from those derived from CBCT, variability between the two methods led to large and unexpected differences in calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of CdTe Addition on the Electrical Properties and AC Susceptibility of YBa{sub 2}Cu{sub 3}O{sub 7−δ} Superconductor

The effect of CdTe addition on YBa{sub 2}Cu{sub 3}O{sub 7−δ}(CdTe){sub x} (x = 0–0.10) has been studied. XRD patterns showed the presence of impurities including CdTe for x ≥ 0.05 wt%. The resistance versus temperature curves showed metallic behavior for all samples. The onset temperature T{sub c onset} for all samples is between 90 and 92 K. The superconducting transition width, ΔT{sub c} = 4 K for all samples except for x = 0.1 wt% where ΔT{sub c} = 6 K. The superconducting transition determined by AC susceptibility measurement also showed little change in T{sub cχ{sup ′}} (between 89 and 92 K). However, the peak temperature T{sub p} of the imaginary part of the susceptibility χ″, showed a drastic decrease for samples with x > 0.05 wt%. This indicated that the superconducting grains were strongly decoupled for x > 0.05 wt% due to the impurities as observed in the XRD pattern. The intergrain critical current density, J{sub c} at T{sub p} for the x = 0 sample is J{sub c} (82 K) = 17 A cm{sup −2}. These results can be useful in the fabrication of semiconductor/YBCO superconductor hybrid systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AC Susceptibility and Superconducting Properties of Graphene Added YBa{sub 2}Cu{sub 3}O{sub 7−d}

The effect of graphene (G) addition on YBa{sub 2}Cu{sub 3}O{sub 7−δ}(G){sub x} (x = 0 − 0.03 wt%) has been studied using the X-ray diffraction method, scanning electron microscopy, electrical resistance versus temperature, transport critical current density J{sub c}, and AC susceptibility measurements. XRD patterns showed single-phase YBa{sub 2}Cu{sub 3}O{sub 7−δ} (YBCO) for all samples. SEM micrographs showed filling of the voids between YBa{sub 2}Cu{sub 3}O{sub 7−δ} grains as graphene was added. The temperature-dependent electrical resistance curves showed metallic normal state behavior and onset transition temperature T{sub conset} between 90 and 92 K for all samples. AC susceptibility measurement showed transition temperature T{sub cχ{sup ′}} between 90 and 93 K. T{sub cχ{sup ′}} was maintained or improved slightly as graphene was added. The x = 0.001 wt% showed the highest J{sub c}, i.e., 2750 A cm{sup −2} at 77 K and 5570 mA cm{sup −2} at 30 K which was 13 and 40 times higher than that of the non-added YBCO, respectively. The peak temperature T{sub p} of the imaginary part of the susceptibility χ{sup ″} was around 78–82 K for all samples indicating grain coupling was not weakened as graphene was added.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

YBa{sub 2}Cu{sub 3}O{sub 7} microwave resonators for strong collective coupling with spin ensembles

Coplanar microwave resonators made of 330 nm-thick superconducting YBa{sub 2}Cu{sub 3}O{sub 7} have been realized and characterized in a wide temperature (T, 2–100 K) and magnetic field (B, 0–7 T) range. The quality factor (Q{sub L}) exceeds 10{sup 4} below 55 K and it slightly decreases for increasing fields, remaining 90% of Q{sub L}(B=0) for B = 7 T and T = 2 K. These features allow the coherent coupling of resonant photons with a spin ensemble at finite temperature and magnetic field. To demonstrate this, collective strong coupling was achieved by using di(phenyl)-(2,4,6-trinitrophenyl)iminoazanium organic radical placed at the magnetic antinode of the fundamental mode: the in-plane magnetic field is used to tune the spin frequency gap splitting across the single-mode cavity resonance at 7.75 GHz, where clear anticrossings are observed with a splitting as large as ∼82 MHz at T = 2 K. The spin-cavity collective coupling rate is shown to scale as the square root of the number of active spins in the ensemble.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safety and Efficacy of Transarterial Radioembolization Combined with Chemoembolization for Bilobar Hepatocellular Carcinoma: A Single-Center Retrospective Study

BackgroundRadioembolization induced liver disease (REILD) is a possible sequela of transarterial radioembolization (TARE), particularly in cases of whole-liver treatment. To mitigate this problem, the safety and efficacy of combined transarterial chemoembolization (TACE) and TARE were evaluated for patients with bilobar hepatocellular carcinoma (HCC).Materials and MethodsNineteen patients (mean age 60 years; range 27–82 years) treated for HCC between June 2012 and September 2014 were included in the analysis. Each patient was treated with combined TARE and TACE for bilobar HCC, with or without portal vein thrombosis. The hepatic lobe with large HCC was treated with TARE, and the other lobe with small HCC(s) was treated with TACE. Laboratory and clinical data were investigated to determine REILD occurrence. Survival data were analyzed to compare the treatment efficacy of alternative treatment modalities, including TACE and sequential TARE.ResultsAll patients underwent TARE for a dominant tumor in one lobe and TACE for small nodule(s) in the other lobe of the liver. The mean yttrium-90 microspheres used in TARE were 2.8 GBq (range; 1.0-3.5 GBq), and the mean doses of doxorubicin and iodized oil were 24.5 mg and 5.2 mL, respectively, for TACE. No statistical differences were noted between laboratory data measured before and after treatment, and no procedure-related major clinical complications occurred. The median time-to-progression of patients was 10.0 months, and the median overall survival was 27.3 months.ConclusionCombined radioembolization and chemoembolization appears to be a safe and effective treatment modality for bilobar HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Temperature Fracture Characteristics of a Nanostructured Ferritic Alloy (NFA)

High temperature fracture behavior has been investigated for the nanostructured ferritic alloy 14YWT (SM10). The fracture toughness of the alloy was above 140 MPa m at low temperatures, room temperature (RT) and 200 C, but decreased to a low fracture toughness range of 52 82 MPa m at higher temperatures up to 700 C. This behavior was explained by the fractography results indicating that the unique nanostructure of 14YWT alloy produced shallow plasticity layers at high temperatures and a low-ductility grain boundary debonding occurred at 700 C.

36 MATERIALS SCIENCE↗

Calculations of single crystal elastic constants for yttria partially stabilised zirconia from powder diffraction data

Yttria Stabilised Zirconia (YSZ) is a tough, phase-transforming ceramic that finds use in a wide range of commercial applications from dental prostheses to thermal barrier coatings. Micromechanical modelling of phase transformation can deliver reliable predictions in terms of the influence of temperature and stress. However, models must rely on the accurate knowledge of single crystal elastic stiffness constants. Some techniques for elastic stiffness determination are well-established. The most popular of these involve exploiting frequency shifts and phase velocities of acoustic waves. However, the application of these techniques to YSZ can be problematic due to the micro-twinning observed in larger crystals. Here, we propose an alternative approach based on selective elastic strain sampling (e.g., by diffraction) of grain ensembles sharing certain orientation, and the prediction of the same quantities by polycrystalline modelling, for example, the Reuss or Voigt average. The inverse problem arises consisting of adjusting the single crystal stiffness matrix to match the polycrystal predictions to observations. In the present model-matching study, we sought to determine the single crystal stiffness matrix of tetragonal YSZ using the results of time-of-flight neutron diffraction obtained from an in situ compression experiment and Finite Element modelling of the deformation of polycrystalline tetragonal YSZ. The best match between the model predictions and observations was obtained for the optimized stiffness values of C11 = 451, C33 = 302, C44 = 39, C66 = 82, C12 = 240, and C13 = 50 (units: GPa). Considering the significant amount of scatter in the published literature data, our result appears reasonably consistent.

36 MATERIALS SCIENCE↗

Spectral and lasing characteristics of 1% Ho:YAG ceramics under intracavity pumping

High-transparency 1% Ho:YAG ceramics with the transmission coefficient of 82% in the IR range at the sample thickness of 1 mm are synthesised from a mixture of the Ho:Y{sub 2}O{sub 3} and Al{sub 2}O{sub 3} nanopowders obtained by the laser method. Results of investigations of spectral and lasing characteristics of 1 % Ho:YAG ceramics under intracavity pumping by radiation of a 5% Tm:KLuW disk element are presented. Based on spectral intensity analysis of generation in the 1.8 – 2.1 mm range and on cavity parameters, the estimated lasing slope efficiency for 1% Ho:YAG ceramics is about 40%. (lasers)

36 MATERIALS SCIENCE↗

Studies of Neutron-Deficient Nuclei Near the Z = 82 Shell Closure via Cold Fusion Reactions

Over the last decade, we have performed in-beam experiments using Gammasphere+FMA to measure excited states in proton-rich Au, Hg, Tl and Pb isotopes. In these studies, the use of the FMA is essential in order to differentiate evaporation residues from the large fission background which dominates the reaction cross-section. In addition, we have found that using near-symmetric reactions at bombarding energies near the Coloumb barrier is beneficial in performing these studies. By keeping the bombarding energy low, fission is minimized and the reaction products are concentrated in only a few channels. New results have recently been obtained using the {sup 90}Zr+{sup 92}Mo reaction to study shape co-existence in {sup 181}Tl via the lp evaporation channel. In addition, we have measured the total {gamma}-ray energy and multiplicity associated with the surviving compound system, {sup 179}Au, following the fusion reaction, {sup 90}Zr+{sup 89}Y.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation of contact angles at triple phase boundary in solid oxide fuel cell anode using the level set method

A level set method is applied to characterize the three dimensional structures of nickel, yttria stabilized zirconia and pore phases in solid oxide fuel cell anode reconstructed by focused ion beam-scanning electron microscope. A numerical algorithm is developed to evaluate the contact angles at the triple phase boundary based on interfacial normal vectors which can be calculated from the signed distance functions defined for each of the three phases. Furthermore, surface tension force is estimated from the contact angles by assuming the interfacial force balance at the triple phase boundary. The average contact angle values of nickel, yttria stabilized zirconia and pore are found to be 143°–156°, 83°–138° and 82°–123°, respectively. The mean contact angles remained nearly unchanged after 100 hour operation. However, the contact angles just after reduction are different for the cells with different sintering temperatures. In addition, standard deviations of the contact angles are very large especially for yttria stabilized zirconia and pore phases. The calculated surface tension forces from mean contact angles were close to the experimental values found in the literature. Slight increase of surface tensions of nickel/pore and nickel/yttria stabilized zirconia were observed after operation. Present data are expected to be used not only for the understanding of the degradation mechanism, but also for the quantitative prediction of the microstructural temporal evolution of solid oxide fuel cell anode. - Highlights: • A level set method is applied to characterize the 3D structures of SOFC anode. • A numerical algorithm is developed to evaluate the contact angles at the TPB. • Surface tension force is estimated from the contact angles. • The average contact angle values are found to be 143o-156o, 83o-138o and 82o-123o. • Present data are expected to understand degradation and predict evolution of SOFC.

36 MATERIALS SCIENCE↗