Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Y(CO2)4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Phase compatibilities of YBa2Cu3O(9-delta) type structure in quintenary systems Y-Ba-Cu-O-X (impurity)

Electrical transport properties of the oxidic high T(sub c) superconductors are significantly affected by the presence of minor amounts of various elements adventing as impurities, e.g., from the chemical environment during manufacturing. YBa2Cu3O(9-delta) is prone to an extinction of the superconductivity on (partial) substitution of all four elemental components. E.g., Pr (for Y), La (for Ba), Zn (for Cu) or peroxygroup (for O) substituents will alter some of the superconductivity preconditions, like mixed valence state in Cu3O7/O(9-delta) network or structural distortion of the network. Although various pseudoternary chemical equilibrium phase diagrams of the Y(O)-Ba(O)-Cu(O) system now are available, no consensus is generally shown, however, this is partly due to lack of compatible definitions of the equilibrium conditions. Less information is available about the phase compatibilities in the appropriate quaternary phase diagram (including oxygen) and virtually no information exists about any pentenary phase diagrams (including one impurity). Unfortunately, complexity of such systems, stemming both from number of quaternary or pentenary compounds and from visualizing the five-component phase system, limits this presentation to more or less close surroundings of the YBa2Cu3O(9-delta) type phase in appropriate pseudoquaternary or pseudopseudoternary diagrams, involving Y-Ba-Cu and O, O-CO2, alkaline metals, Mg and alkaline earths, and Sc and most of the 3-d and 4-f elements. The systems were investigated by means of x ray diffraction, neutron diffraction and chemical analytical methods on samples prepared by sol-gel technique from citrates. The superconductivity was characterized by measuring the diamagnetic susceptibility by SQUID.

Karen, P.↗

Compatibilities of YBa2Cu3O(9-delta) type phase in quintenary systems Y-Ba-Cu-O-X (impurity)

Isothermal phase diagrams at various oxygen pressures were studied by powder diffraction and chemical analytical methods. The components, Y, Ba, Cu, and O (specifically O2, O2-, and O2 sup 2-) are treated, together with C (specifically CO2 and CO2 sup 2-), alkaline metals, Mg, alkaline earths, Sc, 3-d and 4-f elements. Effects of the substitutions at the structural sites of YBa2Cu3O(9-delta) on T sub c are discussed with respect to changes in crystallochemical characteristics of the substituted phase and to the nature of the substituents.

Karen, P.↗

In situ observations in aircraft exhaust plumes in the lower stratosphere at midlatitudes

Instrumentation on the NASA ER-2 high-altitude aircraft has been used to observe engine exhaust from the same aircraft while operating in the lower stratosphere. Encounters with the exhaust plume occurred approximately 10 min after emission with spatial scales near 2 km and durations of up to 10 s. Measurements include total reactive nitrogen, NO(y), the component species NO and NO2, CO2, H2O, CO, N2O, condensation nuclei, and meteorological parameters. The integrated amounts of CO2 and H2O during the encounters are consistent with the stoichiometry of fuel combustion (1:1 molar). Emission indices (EI) for NO(x) (= NO + NO2), CO, and N2O are calculated using simultaneous measurements of CO2. EI values for NO(x) near 4 g/(kg fuel) are in good agreement with values scaled from limited ground-based tests of the ER-2 engine. Non-NO(x) species comprise less than about 20% of emitted reactive nitrogen, consistent with model evaluations. In addition to demonstrating the feasibility of aircraft plume detection, these results increase confidence in the projection of emissions from current and proposed supersonic aircraft fleets and hence in the assessment of potential long-term changes in the atmosphere.

Fahey, D. W.↗

Effects of temperature, CO2/O2 concentrations and light intensity on cellular multiplication of microalgae, Euglena gracilis

Microalgae culture is likely to play an important role in aquatic food production modules in bioregenerative systems for producing feeds for fish, converting CO2 to O2 and remedying water quality as well as aquatic higher plants. In the present study, the effects of culture conditions on the cellular multiplication of microalgae, Euglena gracilis, was investigated as a fundamental study to determine the optimum culture conditions for microalgae production in aquatic food production modules including both microalgae culture and fish culture systems. E. gracilis was cultured under conditions with five levels of temperatures (25-33 degrees C), three levels of CO2 concentrations (2-6%), five levels of O2 concentrations (10-30%), and six levels of photosynthetic photon flux (20-200 micromoles m-2 s-1). The number of Euglena cells in a certain volume of solution was monitored with a microscope under each environmental condition. The multiplication rate of the cells was highest at temperatures of 27-31 degrees C, CO2 concentration of 4%, O2 concentration of 20% and photosynthetic photon flux of about 100 micromoles m-2 s-1. The results demonstrate that E. gracilis could efficiently produce biomass and convert CO2 to O2 under relatively low light intensities in aquatic food production modules. c2005 Published by Elsevier Ltd on behalf of COSPAR.

Euglena gracilis/drug effects/growth & development↗

Description of SAFIRE for ISES

The SAFIRE (Spectroscopy of the Atmosphere using Far Infrared Emission) is a limb emission experiment using a far-IR Fourier transform spectrometer (FTS) and a mid-IR broadband multispectral radiometer covering the range 80 to 1600/cm. The purpose of this experiment is to obtain vertical distributions of temperature and key constituents of O(y), HO(y), NO(y), ClO(y), and BrO(y) families in the stratosphere, mesosphere, and thermosphere. The spectral channels and gases within each channel are summarized. The instrument includes a 48 element (6 x 8) Ge:GA detector array operating at 4 K in the far-IR and a 105 element (7 x 15) HgCdTe array operating at 80 K in the mid-IR. The SAFIRE uses four different scan modes for vertical coverage and resolution to address various scientific requirements. The SAFIRE data reduction will start with the retrieval of temperature profile as a function of pressure using two CO2 channel data. Constituent distributions then are obtained from other channel data using the retrieved temperature profile. The SAFIRE measurements are limited to the region above the tropopause because of radiance saturation by H2O and clouds. The computational capability necessary to process at the instrument data rate is estimated to be 19 MFLOPS for FTS data and 0.02 MFLOPS for radiometer data. It seems, therefore, that the real-time applications of SAFIRE data using an onboard processing device is not feasible. Although a temperature anomaly may be detected from the two CO2 radiometer channels using an onboard processor for the stratosphere, it is not possible to distinguish between CO2 outflux and temperature anomaly. Temperature anomaly does not, therefore, offer tropospheric information useful for real-time application.

Park, Jae H.↗

Abundance and chemistry of interstellar HOCO(+)

Column densities of 10 to the 15th/sq cm toward the Galactic center and not more than 10 to the 12th/sq cm for cold dark clouds are derived from observations using an LVG model, and the chemical implications are discussed. The HOCO(+) 4(04)-3(03) line toward Sgr A is mapped. The fractional abundance of HOCO(+) in the Galactic center region was found to be three orders of magnitude larger than predicted by quiescent ion-molecule chemistry and an order of magnitude larger than predicted by an MHD shock model. It is suggested that the possibly high CO2 abundance, and consequently the observed HOCO(+) abundance in the Galactic center, may result from UV photolysis of grain mantles.

Minh, Y. C.↗

Increasing CO2 Coupled with Other Anthropogenic Perturbations: Effects on Ozone and Other Trace Gases

The GSFC 2D interactive chemistry-radiation-dynamics model has been used to study the effects on stratospheric trace gases of past and future CO2 increases coupled with changes in CFC'S, methane, and nitrous oxide. Previous simulations with the GSFC model showed that the stratospheric cooling calculated to result from doubling atmospheric CO2 would lead, in the absence of a growth of other anthropogenic gases, to a decrease in upper stratospheric NO(y) of roughly 15%. This work has been extended to simulate changes in stratospheric chemistry and dynamics occurring between the years 1960 and 2050. The simulations have been carried out with and without changes in CO2. In the low latitude upper stratosphere ozone is predicted to be 10% greater in 2050 than in 1990 when increased CO2 is included, compared with an increase of only 2% without the inclusion of CO2. In the low latitude lower stratosphere, ozone is predicted to decrease by about 1% between 1990 and 2050 when CO2 changes are taken into account, in contrast to an approximate 3% increase when they are not. The simulated behavior of water vapor is another example of the coupled responses. Between 1990 and 2050 low latitude water vapor is predicted to increase by 4% and 2% in the upper and lower stratosphere, respectively, without the inclusion of CO2 increases. with the inclusion of CO2 changes, the water vapor increases are predicted to be roughly 12% and 8%, for the upper and lower stratosphere, respectively.

Rosenfield, J. E.↗

Observations of interstellar HOCO(+) - Abundance enhancements toward the Galactic center

The 4(04)-3(03) and 1(01)-0(00) transitions of HOCO(+) toward several molecular clouds have been monitored. Of the molecular clouds considered, the HOCO(+) molecule has been detected only in Sgr B2 and Sgr A. The results suggest that gas phase CO2 is not a major carbon reservoir in typical molecular clouds. For Sgr B2, the column density of HOCO(+) at the northern peak is found to be about 3 x 10 to the 14th/sq cm, and a fractional abundance relative to H2 is obtained which is about 2 orders of magnitude greater than recent theoretical predictions.

Minh, Y. C.↗

The Atmospheres of Saturn and Titan in the Near-Infrared: First Results of Cassini/VIMS

The wide spectral coverage and extensive spatial, temporal, and phase-angle mapping capabilities of the Visual Infrared Mapping Spectrometer (VIMS) onboard the Cassini-Huygens Orbiter are producing fundamental new insights into the nature of the atmospheres of Saturn and Titan. For both bodies, VIMS maps over time and solar phase angles provide information for a multitude of atmospheric constituents and aerosol layers, providing new insights into atmospheric structure and dynamical and chemical processes. For Saturn, salient early results include evidence for phosphine depletion in relatively dark and less cloudy belts at temperate and mid-latitudes compared to the relatively bright and cloudier Equatorial Region, consistent with traditional theories of belts being regions of relative downwelling. Additional Saturn results include (1) the mapping of enhanced trace gas absorptions at the south pole, and (2) the first high phase-angle, high-spatial-resolution imagery of CH4 fluorescence. An additional fundamental new result is the first nighttime near-infrared mapping of Saturn, clearly showing discrete meteorological features relatively deep in the atmosphere beneath the planet's sunlit haze and cloud layers, thus revealing a new dynamical regime at depth where vertical dynamics is relatively more important than zonal dynamics in determining cloud morphology. Zonal wind measurements at deeper levels than previously available are achieved by tracking these features over multiple days, thereby providing measurements of zonal wind shears within Saturn's troposphere when compared to cloudtop movements measured in reflected sunlight. For Titan, initial results include (1) the first detection and mapping of thermal emission spectra of CO, CO2, and CH3D on Titan's nightside limb, (2) the mapping of CH4 fluorescence over the dayside bright limb, extending to approximately 750 km altitude, (3) wind measurements of approximately 0.5 ms(exp -1), favoring prograde, from the movement of a persistent (multiple months) south polar cloud near 88 deg S latitude, and (4) the imaging of two transient mid-southern-latitude cloud features.

Cassini Mission↗

Cyanobacterial mats: Microanalysis of community metabolism

The microbial communities in two sites were studied using several approaches: (1) light microscopy; (2) the measurement of microprofiles of oxygen and sulfide at the surface of the microbial mat; (3) the study of diurnal variation of oxygen and sulfides; (4) in situ measurement of photosynthesis and sulfate reduction and study of the coupling of these two processes; (5) measurement of glutathione in the upper layers of the microbial mat as a possible oxygen quencher; (6) measurement of reduced iron as a possible intermediate electron donor along the established redoxcline in the mats; (7) measurement of dissolved phosphate as an indicator of processes of break down of organic matter in these systems; and (8) measurement of carbon dioxide in the interstitial water and its delta C-13 in an attempt to understand the flow of CO2 through the systems. Microbial processes of primary production and initial degradation at the most active zone of the microbial mat were analyzed.

Cohen, Y.↗

Lunar surface mining for automated acquisition of helium-3: Methods, processes, and equipment

In this paper, several techniques considered for mining and processing the regolith on the lunar surface are presented. These techniques have been proposed and evaluated based primarily on the following criteria: (1) mining operations should be relatively simple; (2) procedures of mineral processing should be few and relatively easy; (3) transferring tonnages of regolith on the Moon should be minimized; (4) operations outside the lunar base should be readily automated; (5) all equipment should be maintainable; and (6) economic benefit should be sufficient for commercial exploitation. The economic benefits are not addressed in this paper; however, the energy benefits have been estimated to be between 250 and 350 times the mining energy. A mobile mining scheme is proposed that meets most of the mining objectives. This concept uses a bucket-wheel excavator for excavating the regolith, several mechanical electrostatic separators for beneficiation of the regolith, a fast-moving fluidized bed reactor to heat the particles, and a palladium diffuser to separate H2 from the other solar wind gases. At the final stage of the miner, the regolith 'tailings' are deposited directly into the ditch behind the miner and cylinders of the valuable solar wind gases are transported to a central gas processing facility. During the production of He-3, large quantities of valuable H2, H2O, CO, CO2, and N2 are produced for utilization at the lunar base. For larger production of He-3 the utilization of multiple-miners is recommended rather than increasing their size. Multiple miners permit operations at more sites and provide redundancy in case of equipment failure.

Li, Y. T.↗

Intensity and Self-Broadening Measurements of the 01(exp 1)21-00(exp 0)01 CO2 Perpendicular Band at 5315/cm

The near-infrared thermal emission windows in the spectrum of the night-side of Venus have stimulated new determinations of the intensities of weak CO2 bands which are prominent absorption features in Venus spectra. Parameters for many unmeasured bands have been recomputed for the HITRAN compilation using direct numerical diagonalization (DND) [Wattson and Rothman, J.Q.S.R.T. 48, 763 (1992)]. To assess these HITRAN values, we have been measuring several of these bands on spectra which were obtained using the Kitt Peak McMath FTS and 6-meter White cell. Last year we presented preliminary intensity measurements of the 01(exp 1)21-00(exp 0)01 perpendicular band and 4 associated hot bands, Five additional McMath FTS spectra have now been obtained covering the region 3800 to 8400/cm. This permits us to finalize our intensity measurements, and to make an assessment of their uncertainties. We anticipate that these measured values will help improve further DND calculations of many weak unmeasureable bands. In addition, self-broadening parameters were determined for some lines of the 01(exp 1)21-00(exp 0)01 perpendicular band on spectra obtained with 65 and 80 torr of CO2. Because of the large spectral range, these measurements could be compared directly to self-broadening parameters of corresponding parallel. band lines measured on the same spectra. This procedure eliminates several possible sources of systematic errors that are important when attempting to determine whether or not corresponding rotational lines in different overtone-combination bands have significant differences. Our measurements thus far have found self-broadening parameters for the 01(exp 1)21-00(exp 0)01 perpendicular band to be slightly larger than similar measurements for the 30(exp 0)14-00(exp 0)01 parallel band at 6076/cm.

Giver, Lawrence P.↗

One-Carbon Metabolism and SANS 2022 Update

Spaceflight Associated Neuro-ocular Syndrome, or SANS, affects a subset of astronauts (1, 2), and biochemical evidence has documented differences in those astronauts (3). Specifically, they had higher circulating concentrations of metabolites of the one-carbon metabolic pathway (1C), including homocysteine, and these concentrations were higher before flight (3). After ruling out many potential confounding factors in these otherwise healthy individuals (e.g., sex, kidney function, vitamin status, coffee consumption), a study of genetics was warranted. In an initial pilot effort, we documented a genetic predisposition to develop ophthalmic changes after long-duration space flight (4). That is, from a limited study of 5 single-nucleotide polymorphisms (SNPs), we found that the G allele for the MTRR A66G SNP was associated with a greater risk of choroidal folds and cotton-wool spots after flight, and the C allele for SHMT1 C1420T was protective against optic disc edema (4). These data provide a potential pathway for understanding why some individuals develop SANS, while others do not. The initial pilot study of 5 SNPs yielded striking findings, but the 1C pathway is far more complex. An effort was undertaken to examine more than 500 1C SNPs to see if a broader examination could help illuminate this association. That work is ongoing. The astronaut findings led us to advocate for the inclusion of 1C pathway genetic and biochemistry testing on other SANS-related projects, noting that genetics might help identify responders, non-responders, or outliers. The first such effort yielded evidence of an association of specific forms of the MTRR and SHMT-1 SNPs and vitamin B12 status with end-tidal CO2 after acute carbon dioxide exposure (5). The second such effort led to the identification that individuals exposed to strict head-down tilt and CO2 for 30-d who developed optic disc edema also had risk alleles for the two SNPs described above (6). Additionally, we identified a clinical population with many characteristics either attributed or purported to be involved in the ocular changes seen in affected astronauts: women with polycystic ovary syndrome (PCOS). PCOS is a condition of androgen excess and anovulatory menstrual cycles. The shared characteristics and clinical findings between SANS and PCOS generally include higher circulating homocysteine concentrations, increased retinal nerve fiber layer thickness, increased androgen concentrations (or responses), and altered carbohydrate metabolism. To our knowledge, no study has examined whether women with PCOS have asymptomatic ophthalmic anomalies observed in astronauts with SANS. While researchers have evaluated the one-carbon metabolism pathway polymorphisms of PCOS patients, and initial studies show an association with certain one-carbon polymorphisms, none have looked at the set of SNPs identified in our studies that are associated with ophthalmic changes in astronauts. Accordingly, we designed a study to evaluate the association of one-carbon pathway SNPs and ophthalmic findings in patients with PCOS and/or IIH compared to controls. Subjects provided blood samples for vitamin and one carbon biochemistry analyses, an extensive analysis of >500 SNPs associated with one carbon metabolism and had eye examinations and ocular imaging. Data analysis are underway. The data collected to date have shown associations between one carbon pathway biochemistry and genetics and incidence of SANS. The mechanisms for SANS has yet to be identified, although many hypotheses exist. Based on our data, we have developed (8, 9) and expanded (6) a multi-hit hypothesis for how these seemingly disparate findings could be linked. While intriguing, the hypothesis represents the starting point for further research. We aim to clarify the relationship between B-vitamin status and genetics with regard to the risk of SANS. Ultimately, understanding the mechanism(s) behind this will provide a means to predict, prevent, or treat these ophthalmologic pathologies in astronauts, and terrestrial populations.

S M Smith↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗