Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser-induced fluorescence measurements of argon and xenon ion velocities near the sheath boundary in 3 ion species plasmas

The Bohm sheath criterion is studied with laser-induced fluorescence in three ion species plasmas using two tunable diode lasers. Krypton is added to a low pressure unmagnetized DC hot filament discharge in a mixture of argon and xenon gas confined by surface multi-dipole magnetic fields. The argon and xenon ion velocity distribution functions are measured at the sheath-presheath boundary near a negatively biased boundary plate. The potential structures of the plasma sheath and presheath are measured by an emissive probe. Results are compared with previous experiments with Ar–Xe plasmas, where the two ion species were observed to reach the sheath edge at nearly the same speed. This speed was the ion sound speed of the system, which is consistent with the generalized Bohm criterion. In such two ion species plasmas, instability enhanced collisional friction was demonstrated [Hershkowitz et al., Phys. Plasmas 18(5), 057102 (2011).] to exist which accounted for the observed results. When three ion species are present, it is demonstrated under most circumstances the ions do not fall out of the plasma at their individual Bohm velocities. It is also shown that under most circumstances the ions do not fall out of the plasma at the system sound speed. These observations are also consistent with the presence of the instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the Charge State of Xenon Ions on the Depth Distribution Profile Upon Implantation into Silicon

Experimental depth distributions of the concentration of implanted xenon ions depending on their charge state and irradiation energy are presented. Xenon ions in charge states q = 1–20 and energies in the range from 50 to 400 keV are incorporated into single-crystal silicon. Irradiation is performed in the direction not coinciding with the crystallographic axes of the crystal to avoid the channeling effect. The ion fluence varies in the range of 5 × (10{sup 14}–10{sup 15}) ion/cm{sup 2}. The irradiation by singly charged ions and investigation of the samples by Rutherford backscattering spectroscopy is performed using an HVEE acceleration complex at Moscow State University. Multiply charged ions are implanted using a FAMA acceleration complex at the Vinća Institute of Nuclear Sciences. The depth distribution profiles of the incorporated ions are found using Rutherford backscattering spectroscopy. Experimental results are correlated with computer calculations. It is shown that the average projective path of multiply charged ions in most cases is shorter when compared with the average projected path of singly charged ions and the results of computer modeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence for an Ultrafast Breakdown of the BeO Band Structure Due to Swift Argon and Xenon Ions

Auger-electron spectra associated with Be atoms in the pure metal lattice and in the stoichiometric oxide have been investigated for different incident charged particles. For fast incident electrons, for Ar{sup 7+} and Ar{sup 15+} ions as well as Xe{sup 15+} and Xe{sup 31+} ions at velocities of 6% to 10% the speed of light, there are strong differences in the corresponding spectral distributions of Be-K Auger lines. These differences are related to changes in the local electronic band structure of BeO on a femtosecond time scale after the passage of highly charged heavy ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

KLL dielectronic recombination resonant strengths of He-like up to O-like xenon ions

In this work, the KLL dielectronic recombination (DR) resonant strengths of He- through to O-like Xe ions were studied, both through experiment and calculation. The experiments were done using a fast electron beam-energy scanning technique at the Shanghai electron beam ion trap. The calculations were done by using the flexible atomic code (FAC), in which the relativistic configuration interaction (RCI) method was employed. For the total resonant strengths, the present experimental and theoretical results for He-, Be-, B-, C-, N-, and O-like Xe ions agree within experimental uncertainties (about 9%). But the experimental result for Li-like Xe is 14% higher than the calculation. The present FAC calculations of the total DR strengths were compared with the available previous calculations, using RCI or multiconfiguration Dirac-Fock (MCDF) methods, and the agreement was very good. In this work, some intermediate-state resolved KLL DR strengths were also obtained and compared with theoretical results, and more discrepancies were revealed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single-Ion Tracks in Gd2Zr2-xTixO7 Pyrochlores Irradiated with Swift Heavy Ions

Swift xenon ions (1.43 GeV) were used to systematically investigate the radiation response of pyrochlores in the Gd2Zr2-xTixO7 binary in the electronic energy loss regime. Ion-induced structural modifications were characterized by synchrotron x-ray diffraction, Raman spectroscopy and transmission electron microscopy. In general, individual ion tracks consist of amorphous domains (in the core of the track) and are surrounded by a crystalline, but disordered structure (track shell), and finally, by a defect-rich region (track halo). The size and structure of these concentric regions, which form dynamically in single ion tracks, depend on the chemical composition. The overall extent of the radiation damage strongly increases with Ti-content, and this confirms the enhanced radiation stability of Zr-rich pyrochlore, even within single swift heavy ion tracks.

43 PARTICLE ACCELERATORS↗

Ion Generation Using Frozen Xenon Target for Laser Ion Source

A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. Here, the results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.

43 PARTICLE ACCELERATORS↗

Study of the characteristics of a piezoelectric lead zirconate titanate radiation detector using a pulsed xenon source

The detector characteristics of piezoelectric lead zirconate titanate (PZT) were studied by directly irradiating a multilayered PZT detector with 400 MeV/n xenon ions. An extracted beam was processed with a rotating slit. Thus, passed through {approx}10{sup 3} xenon ions were available for 50 to 250 {mu}s. The effect of polarization on the output signal was discussed, and the optimal electrode configuration was determined. The output signal appeared as an isolated pulse whose amplitude was qualitatively understood by the Bethe-Bloch formula. However, the calculated and the observed values differed depending on the rotation speed of the slit. A process that can explain the differences is presented here. The output signal appearing beyond the range of 400 MeV/n xenon ion beam was discussed. The sensitivity was compared with that obtained with hypervelocity collision of dust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Beam Ionization at High Gas Densities

In this simulation, an electron beam (blue circles) passes through a mixture of hydrogen and xenon gases that it ionizes, transforming the mixture into a plasma of protons, xenon ions, and electrons. The electron beam’s self-field expels the plasma electrons radially. The ions then undergo a Coulomb explosion under their own self-fields: first the lighter hydrogen ions and later the heavier xenon ions. An external extraction field that is applied between the top and bottom electrodes, and under the right conditions it can move both types of ions through the aperture in the top plate before they expand to a diameter larger than the aperture size. In this case, though, the initial gas densities are too high and the Coulomb field dominates the external field, so the ions are not captured by the aperture in the top plate. (Credit: Jean-Luc Vay and Rémi Lehe, WARP code)

43 PARTICLE ACCELERATORS↗

Multiconfiguration Dirac–Hartree–Fock energy levels, weighted oscillator strengths, transitions probabilities, lifetimes, hyperfine constants, Landé g-factors and isotope shifts of Xe LIII

Energy levels, weighted oscillator strengths and transition probabilities, lifetimes, hyperfine interaction constants, Landé g{sub J} factors and isotope shifts are calculated for all levels of 1s{sup 2} and 1snl (n=2−7) configurations of He-like xenon ion (Xe LIII). Multiconfigurational Dirac–Hartree–Fock (MCDHF) method is adopted for calculating these spectroscopic data. Comparisons are made with similar data obtained with FAC (Flexible Atomic Code) to assess the accuracy of the results. Transition probabilities are reported for all E1, E2, M1 and M2 transitions from the ground level. Breit interactions and quantum electrodynamics effects are estimated in extensive Relativistic Configuration Interaction (RCI) calculations. Comparisons were made with the available data in the literature and good agreement was found which confirms the reliability of our results. The accuracy of the present calculations is high enough to facilitate identification of many observed spectral lines. Almost all atomic data of He-like xenon ion presented in this paper are calculated for the first time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of amorphous alloys and amorphous-crystalline composites in the Cu-Nb-Hf system by ion beam mixing

Seven sets of Cu-Nb-Hf multilayered films were designed and prepared with the overall compositions of Cu{sub 21}Nb{sub 65}Hf{sub 14}, Cu{sub 33}Nb{sub 49}Hf{sub 18}, Cu{sub 34}Nb{sub 34}Hf{sub 32}, Cu{sub 34}Nb{sub 10}Hf{sub 56}, Cu{sub 50}Nb{sub 23}Hf{sub 27}, Cu{sub 58}Nb{sub 10}Hf{sub 32}, and Cu{sub 70}Nb{sub 8}Hf{sub 22}, and an ion beam mixing experiment was then conducted using 200 keV xenon ions. It is found that the Cu-Nb-Hf system is a metallic glass forming one, and the single amorphous alloys could be synthesized in the Cu-Nb-based alloys with less than 18 at.% of Hf as a third addition. Also, when the Hf concentration is greater than 18 at.%, i.e., at the compositions of Cu{sub 34}Nb{sub 34}Hf{sub 32}, Cu{sub 34}Nb{sub 10}Hf{sub 56}, Cu{sub 50}Nb{sub 23}Hf{sub 27}, Cu{sub 58}Nb{sub 10}Hf{sub 32}, and Cu{sub 70}Nb{sub 8}Hf{sub 22}, ion beam mixing resulted in the formation of amorphous-crystalline composites, which might have better mechanical properties than single-phase glassy alloys. In addition, a detailed discussion was presented for the formation mechanism of the amorphous alloys and amorphous-crystalline composites.

36 MATERIALS SCIENCE↗

High efficiency noble gas electron impact ion source for isotope separation

An electron impact ion source has been designed for generation of noble gas ions in a compact isotope separator. The source utilizes a circular filament that surrounds an ionization chamber, enabling multiple passes of electrons through the ionization chamber. This report presents ion optical design and the results of efficiency and sensitivity measurements performed in an ion source test chamber and in the compact isotope separator. The cylindrical design produced xenon ions at an efficiency of 0.37% with a sensitivity of ~24 µA /Pa at 300 µA of electron current.

07 ISOTOPE AND RADIATION SOURCES↗

Subpicosecond 41.8-nm X-ray laser in the plasma produced by femtosecond laser irradiation of a xenon cluster jet

Model calculations are performed of the radiation gain for the 4d5d (J = 0) - 4d5p (J = 1) transition with a wavelength of 41.8 nm in Pd-like xenon ions in the plasma produced by femtosecond laser irradiation of a xenon cluster jet. Conditions for the excitation of an ultrashort-pulse ({approx}1 ps) X-ray laser are discussed. (lasers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision Measurement of the K-Shell Spectrum from Highly Charged Xenon with an Array of X-Ray Calorimeters

We present a measurement of the K-shell spectrum from highly charged xenon ions recorded with a high-energy x-ray calorimeter spectrometer array that can distinguish between various theories for the atomic structure of the two electron system. The array was designed to provide high resolution with high quantum efficiency in the 10-60 keV x-ray range which allows us to resolve blends that afflicted previous measurements. A precision of better than 2 eV was achieved in the measurement of the Xe{sup 52+} and Xe{sup 53+} K-shell transitions located near 31 keV, which is an order of magnitude better than previously reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission electron microscopy of the amorphization of copper indium diselenide by in situ ion irradiation

Copper indium diselenide (CIS), along with its derivatives Cu(In,Ga)(Se,S){sub 2}, is a prime candidate for use in the absorber layers of photovoltaic devices. Due to its ability to resist radiation damage, it is particularly well suited for use in extraterrestrial and other irradiating environments. However, the nature of its radiation hardness is not well understood. In this study, transmission electron microscopy (TEM) with in situ ion irradiation was used to monitor the dynamic microstructural effects of radiation damage on CIS. Samples were bombarded with 400 keV xenon ions to create large numbers of atomic displacements within the thickness of the TEM samples and thus explore the conditions under which, if any, CIS could be amorphized. By observing the impact of heavily damaging radiation in situ--rather than merely the end-state possible in ex situ experiments--at the magnifications allowed by TEM, it was possible to gain an understanding of the atomistic processes at work and the underlying mechanism that give rise to the radiation hardness of CIS. At 200 K and below, it was found that copper-poor samples could be amorphized and copper-rich samples could not. This difference in behavior is linked to the crystallographic phases that are present at different compositions. Amorphization was found to progress via a combination of one- and two-hit processes. The radiation hardness of CIS is discussed in terms of crystallographic structures/defects and the consequences these have for the ability of the material to recover from the effects of displacing radiation.

36 MATERIALS SCIENCE↗

Unexpected transverse velocity component of Xe{sup +} ions near the exit plane of a Hall thruster

The velocity component of singly charged xenon ions in a plane perpendicular to the thrust axis of the 1 kW-class PPS100-ML Hall effect thruster is deduced from laser induced fluorescence measurements on the 5d {sup 2}F{sub 7/2}{yields}6p {sup 2}D{sub 5/2}{sup 0} electronic transition at 834.72 nm. Measurements are carried out at several locations in the near field of the channel exhaust. Thruster operating parameters, such as magnetic field strength, discharge voltage, and xenon mass flow rate, are varied over a wide range. The initial aim of this work was to measure the azimuthal velocity of the ions due to their weak magnetic deflection. Surprisingly, experimental results cannot be explained by the one and only Lorentz force acting on Xe{sup +} ions. A realistic picture of the ion trajectory in the ExB drift plane is obtained when adding a velocity component directed toward the external cathode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗