Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON 131”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Double-{beta}-decay Q values of {sup 130}Te, {sup 128}Te, and {sup 120}Te

The double-{beta}-decay Q values of {sup 130}Te, {sup 128}Te, and {sup 120}Te have been determined from parent-daughter mass differences measured with the Canadian Penning Trap mass spectrometer. The {sup 132}Xe-{sup 129}Xe mass difference, which is precisely known, was also determined to confirm the accuracy of these results. The {sup 130}Te Q value was found to be 2527.01{+-}0.32 keV, which is 3.3 keV lower than the 2003 Atomic Mass Evaluation recommended value and is consistent with another recent Penning trap measurement. The {sup 128}Te and {sup 120}Te Q values were found to be 865.87{+-}1.31 and 1714.81{+-}1.25 keV, respectively. For {sup 120}Te, this reduction in uncertainty of nearly a factor of 8 opens up the possibility of using this isotope for sensitive searches for neutrinoless double-electron capture and electron capture with {beta}{sup +}emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Figure-of-Merit for Beta Cell Detector Characterization

In order to decrease the minimum detectable activities (MDAs) of beta-gamma radioxenon detectors, it is important to increase the ability to resolve the individual isotopes. One proposed method for doing this is to increase the energy resolution of the beta cell through the use of silicon detectors. While silicon detectors can improve the energy resolution, it is accompanied with a decrease in detection efficiency compared to plastic scintillator beta cells. Due to the uncertainty on the impact of the competing variables, we have developed a figure-of-merit (FOM) capable of determining the impact of detector parameters on the MDAs. By utilizing the FOM to analyze different detectors, we are able to directly compare current and future detectors and estimate their impact on the radioxenon MDAs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2016 NIST (133Xe) and Transfer (131mXe, 133mXe, 135Xe) Calibration Report

A significantly improved calibration of the High Purity Germanium detectors used by the Idaho National Laboratory Noble Gas Laboratory was performed during the annual NIST calibration. New sample spacers provide reproducible and secure support of samples at distances of 4, 12, 24, 50 and 100 cm. Bean, 15mL and 50mL Schlenk tube geometries were calibrated. Also included in this year’s calibration was a correlation of detector dead-time with sample activity that can be used to predict the schedule of counting the samples at each distance for each geometry. This schedule prediction will help staff members set calendar reminders so that collection of calibration data at each geometry will not be missed. This report also correlates the counting efficiencies between detectors, so that if the counting efficiency on one detector is not known, it can be estimated from the same geometry on another detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nature of the Effect of Precession-Frequency Mismatch between {sup 129}Xe and {sup 131}Xe Nuclei under Spin-Exchange Pumping by Alkali-Metal Atoms

The effect of precession-frequency mismatch between {sup 129}Xe and {sup 131}Xe xenon-isotope nuclei, which arises under spin-exchange pumping by optically oriented alkali-metal (Cs) atoms and affects the characteristics of measuring and navigation devices based on balanced Schemes with spin-exchange pumping of xenon isotopes, has been investigated. An attempt to explain this effect has been made, and methods for its minimization and elimination have been proposed and experimentally verified.

74 ATOMIC AND MOLECULAR PHYSICS↗

A high resolution scanning electron microscope for in situ investigation of swift heavy ion induced modification of solid surfaces

A new in situ high resolution electron microscope (HRSEM) setup has been designed and integrated into the materials science beamline (M-branch) of the universal linear accelerator at Gesellschaft fuer Schwerionenforschung, Darmstadt for in situ investigations of swift heavy ion induced surface modifications. Special ports for in situ experiments are installed at the HRSEM chamber to connect it to the high vacuum beamline, which is equipped with suitable beam control and shaping devices. In order to demonstrate the feasibility and power of this new instrument, first experiments were performed on a 50-nm-thick Fe{sub 2}O{sub 3} film on Si substrate, which exhibited submicrometer size holes due to irradiation induced dewetting in a previous experiment. We have demonstrated that with our new instrument, the development of individual dewetting holes as a function of the ion fluence can be investigated and even the interaction between them can be studied. To illustrate pattern formation during grazing incidence, 3.6 MeV/u {sup 131}Xe ion irradiation was carried out on a 25-nm-thick NiO film on SiO{sub 2}/Si at a tilt angle of 75 deg. The SEM image sequence recorded during the experiment reveals the development of a lamellaelike structure also seen before in ex situ experiments. With our new in situ setup, however, we are able to not only investigate the overall average pattern formation, but also to track the formation and decay of individual linking structures, which would be hardly possible in a standard ex situ experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limits on Spin-Dependent WIMP-Nucleon Cross Sections from the XENON10 Experiment

XENON10 is an experiment to directly detect weakly interacting massive particles (WIMPs), which may comprise the bulk of the nonbaryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with {sup 129}Xe and {sup 131}Xe from 58.6 live days of operation at the Laboratori Nazionali del Gran Sasso. Based on the nonobservation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of {approx}10 GeV/c{sup 2}-2 TeV/c{sup 2} as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale shell-model calculations of elastic and inelastic scattering rates of lightest supersymmetric particles (LSP) on {sup 127}I, {sup 129}Xe, {sup 131}Xe, and {sup 133}Cs nuclei

We discuss the dark-matter detection rates for the elastic and inelastic scattering of the lightest supersymmetric particle (LSP) off nuclei. For this we use an easily accessible formalism where the underlying nuclear physics is condensed in structure coefficients multiplying the key parameters of supersymmetric theories. In this work we compute these coefficients for the stable iodine, xenon, and cesium nuclei by application of the nuclear shell model in a model space involving the 2s, 1d, 0g{sub 7/2}, and 0h{sub 11/2} single-particle orbitals. As an interaction we use the renormalized Bonn-CD G matrix. By using fitted nuclear gyromagnetic factors we have successfully reproduced the relevant spectroscopic data on magnetic moments and M1 decays in the discussed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Communication: Nuclear quadrupole moment-induced Cotton-Mouton effect in noble gas atoms

New, high-sensitivity and high-resolution spectroscopic and imaging methods may be developed by exploiting nuclear magneto-optic effects. A first-principles electronic structure formulation of nuclear electric quadrupole moment-induced Cotton-Mouton effect (NQCME) is presented for closed-shell atoms. In NQCME, aligned quadrupole moments alter the index of refraction of the medium along with and perpendicular to the direction of nuclear alignment. The roles of basis-set convergence, electron correlation, and relativistic effects are investigated for three quadrupolar noble gas isotopes: {sup 21}Ne, {sup 83}Kr, and {sup 131}Xe. The magnitude of the resulting ellipticities is predicted to be 10{sup −4}–10{sup −6} rad/(M cm) for fully spin-polarized nuclei. These should be detectable in the Voigt setup. Particularly interesting is the case of {sup 131}Xe, in which a high degree of spin polarization can be achieved via spin-exchange optical hyperpolarization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution laser spectroscopy between 0.9 and 14.3 THz in a supersonic beam: Rydberg-Rydberg transitions of atomic Xe at intermediate n values

A laser-based, pulsed, narrow-band source of submillimeter-wave radiation has been developed that is continuously tunable from 0.1 THz to 14.3 THz. The source is based on difference-frequency mixing in the nonlinear crystal trans-4{sup Prime }-(dimethylamino)-N-methyl-4-stilbazolium tosylate. By varying the pulse length, the bandwidth of the submillimeter-wave radiation can be adjusted between 85 MHz and 2.8 MHz. This new radiation source has been integrated in a vacuum-ultraviolet-submillimeter-ware double-resonance spectrometer, with which low-frequency transitions of atoms and molecules in supersonic beams can be detected mass-selectively by photoionization and time-of-flight mass spectrometry. The properties of the radiation source and spectrometer are demonstrated in a study of 33f Leftwards-Arrow nd Rydberg-Rydberg transitions in Xe with n in the range 16-31. The frequency calibration of the submillimeter-wave radiation was performed with an accuracy of 2.8 MHz. The narrowest lines observed experimentally have a full-width at half-maximum of {approx}3 MHz, which is sufficient to fully resolve the hyperfine structure of the Rydberg-Rydberg transitions of {sup 129}Xe and {sup 131}Xe. A total of 72 transitions were measured in the range between 0.937 THz and 14.245 THz and their frequencies are compared with frequencies calculated by multichannel quantum defect theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical simulation of a signal for a scheme of an atomic spin gyroscope with optical detection

An operation scheme of an atomic spin gyroscope with optical detection is described, in which two noble gas isotopes, {sup 129} Xe and {sup 131} Xe, are used as carriers of the spin of an atomic nucleus. Based on this scheme, we construct a theoretical model of the dynamics of the spin polarisation of an alkali metal and the magnetisation of a noble gas under conditions of spin-exchange interaction and optical pumping. This model allows one to simulate the pumping and signal readout in the gyroscope scheme. The time dependences of this signal are plotted, the analysis of which shows that the signal has a sophisticated complex structure. Thus, the problem arises of demodulating this signal based on the improvement of demodulation methods and algorithms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Millimeter-wave spectroscopy and multichannel quantum-defect-theory analysis of high Rydberg states of xenon: The hyperfine structure of {sup 129}Xe{sup +} and {sup 131}Xe{sup +}

Millimeter-wave transitions between high-n Rydberg states of several isotopes of xenon have been recorded at sub-megahertz resolution. The fine and, for {sup 129}Xe and {sup 131}Xe, hyperfine structures of s, p, d, and f Rydberg states with principal quantum number in the range 52{<=}n{<=}64 have been determined from combination differences and analyzed using multichannel quantum defect theory. Improved eigenquantum defects and channel interaction parameters for the odd- and even-parity Rydberg states of xenon and the hyperfine structure of the {sup 2}P{sub 3/2} ground state of {sup 129}Xe{sup +} and {sup 131}Xe{sup +} have been obtained. Nearly degenerate p and d fine or hyperfine levels are very easily mixed by even weak stray electric fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Limits on the Spin-Dependent WIMP-Nucleon Cross Sections from the First Science Run of the ZEPLIN-III Experiment

We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter weakly interacting massive particles based at the Boulby mine. Analysis of approx450 kgcentre dotdays fiducial exposure allow us to place a 90%-confidence upper limit on the pure WIMP-neutron cross section of sigma{sub n}=1.9x10{sup -2} pb at 55 GeV/c{sup 2} WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn charge-dependent nucleon-nucleon potential were used for the odd-neutron isotopes {sup 129}Xe and {sup 131}Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction could be much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of approx2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a Commercial Scale Accelerator Driven Subcritical Aqueous Assembly

SHINE Medical Technologies is working towards producing a reliable, domestic supply of medical isotopes, including molybdenum-99 (Mo-99), xenon-133, and iodine 131, without using highly enriched uranium. Approximately 88% of Mo-99 decays to technetium-99m, which is the most widely used medical isotope in the world, accounting for approximately 80% of all nuclear medicine procedures. A novel aqueous, subcritical nuclear assembly has been designed by SHINE Medical Technologies. The assembly can produce medical radioisotopes in significant quantities for U.S. and foreign needs. The assembly produces isotopes without using a reactor, instead using a fusion-based neutron source coupled to a fission-based aqueous assembly. The subcritical nature of the aqueous assembly has safety and licensing benefits, including the elimination of the reactor control system and elimination of high level waste. SHINE plans to construct eight subcritical assemblies with a plant capacity of greater than 3000 6-day Curies, which is more than one-quarter of the world's Mo-99 requirements. From a nuclear design standpoint, the aqueous subcritical assembly needs to be able to generate sufficient fission power to meet the production capacity requirements while remaining subcritical at all times with an acceptable margin. To address these conflicting design goals, a simple nuclear design and reactivity control philosophy has been developed that allows for high power operation with a high degree of safety. A fusion-driven subcritical fission assembly has been designed by SHINE Medical Technologies to provide a reliable, domestic supply of medical isotopes. Nuclear models have been created and show that the assembly can be started up, operated, and shutdown in a safe manner without active reactivity control systems. A unique reactivity control strategy allows SHINE to operate the aqueous subcritical assembly at much higher power levels than would otherwise be practical, while still retaining the benefits of subcritical operation and avoiding the need for complex subcritical measurement techniques. Based on the current design, the subcritical target is capable of generating significant fission power (on the order of 100 kW) when being driven by a simple, low-cost deuterium-tritium accelerator, enabling the SHINE facility to supply over one-fourth of the worldwide demand of Mo- 99. SHINE has recently been issued a construction permit by the U.S. Nuclear Regulatory Commission to build the commercial facility in Janesville, WI, with eight subcritical assemblies and the associated production equipment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗