Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON 127”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 127

The 1996 evaluation for the A=127 mass chain (1996Ki01) has been revised. The experimental results from various decays and reactions for the A=127 mass chain have been compiled and evaluated. The nuclides covered in this evaluation are from {sup 127}Ag to {sup 127}Nd. The data are summarized and presented, together with adopted level schemes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Air and radon pathways screenings methodologies for the next revision of the E-area PA

The strategic plan for the next E-Area Low-Level Waste Facility Performance Assessment includes recommended changes to the screening criteria used to reduce the number of radioisotopes that are to be considered in the air and radon pathways incorporated into the GoldSim® atmospheric release model (ARM). For the air pathway, a revised screening methodology was developed based on refinement of previous E-Area PA screening approaches and consideration of the strategic plan recommendations. The revised methodology has three sequential screening steps for each radioisotope: (1) volatility test using the Periodic Table of the Elements, (2) stability test based on half-life, and (3) stability test based on volatility as measured by the Henry’s Law constant for the assumed dominant gaseous species or vapor pressure in the case of tritiated water. Of the 1252 radioisotopes listed in the International Commission on Radiological Protection Publication 107, only the 10 that satisfied all three steps of the revised screening methodology will be included in the ARM. They are: Ar-37, Ar-39, Ar-42, C-14, H-3, Hg-194, Hg-203, Kr-81, Kr-85, and Xe-127. For the radon pathway, a revised screening methodology was developed that also has three sequential steps: (1) identify all decay chains that terminate at Rn-222, (2) screen out parents that decay through U-238 because of its 4.5-billion-year primordial half-life, and (3) eliminate remaining parents whose half-life is shorter than one day. Of the 86 possible decay chains leading to Rn-222, six decay chains consist of 15 unique radioisotopes that will be incorporated into the ARM. The 15 radioisotopes are: U-238, Th-234, Pa-234m, Pu-238, U-234, Th-230, Ra-226, Cf-246, Cm-242, Am-242m, Am-242, Np-238, Np-234, Pa-230, and Rn-222.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of charge and light yields for 127 Xe L -shell electron captures in liquid xenon

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using β -decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner-shell electrons. Such events lead to emission of x rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from β -decay calibration. We present a cross-calibration of tritium β -decays and Xe 127 electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the Xe 127 L -shell electron-capture in liquid xenon. We observe a 6.9 σ ( 9.2 σ ) discrepancy in the L -shell capture response relative to tritium β decays, measured at a drift field of 363 ± 14 V / cm ( 258 ± 13 V / cm ), when compared to simulations tuned to reproduce the correct β -decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1 - σ experiment-to-experiment variation of the 90% C.L. upper limit on the interaction rate of a 50 GeV / c 2 dark matter particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The origin of the background radioactive isotope {sup 127}Xe in the sample of Xe enriched in {sup 124}Xe

The results of investigation of {sup 127}Xe radioactive isotope production in the xenon sample enriched in {sup 124}Xe, {sup 126}Xe, {sup 128}Xe are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of {sup 124}Xe. In this work we consider two channels of {sup 127}Xe production: the neutron knock-out from {sup 128}Xe nucleus by cosmogenic muons and the neutron capture by {sup 126}Xe nucleus. For the first channel the upper limit of the cross section of {sup 127}Xe production was found to be σ ≤ 0.007 × 10{sup −24} cm{sup 2} at 95% C.L. For the second channel the value obtained for the cross section was found to be equal to σ = (2.74 ± 0.4) × 10{sup −24} cm{sup 2}, which coincides well, within the statistical error, with reference value.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting 127 Xe in an atmospheric tracer experiment

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127 Xe in addition to 131m Xe, 133m Xe, 133 Xe, and 135 Xe. The algorithm was applied to 119 samples collected with a SAUNA Q B system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. Finally, the algorithm identified two samples with 127 Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127 Xe were observed in the other samples.

127Xe calibration↗

Ultralow energy calibration of LUX detector using Xe 127 electron capture

We report an absolute calibration of the ionization yields (Q y ) and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy 127 Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of weakly interacting massive particles. The sequence of gamma-ray and x-ray cascades associated with 127 I deexcitations produces clearly identified two-vertex events in the LUX detector. We observe the K-(binding energy, 33.2 keV), L-(5.2 keV), M-(1.1 keV), and N-(186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. In conclusion, the N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil in situ measurements that have been explored in liquid xenon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear model calculations on the production of {sup 125,123}Xe and {sup 133,131,129,128}Ba radioisotopes

In this study, production rates of {sup 125,123}Xe and {sup 133,131,129,128}Ba medical isotopes produced by {sup 127}I(p, 3n){sup 125}Xe, {sup 127}I(p, 5n){sup 123}Xe, {sup 133}Cs(p, n){sup 133mg}Ba, {sup 133}Cs(p, 3n){sup 131mg}Ba, {sup 133}Cs(p, 5n){sup 129}Ba, and {sup 133}Cs(p, 6n){sup 128}Ba reactions have been investigated up to 100 MeV incident proton energy. The preequilibrium calculations involve the hybrid model, the geometry-dependent hybrid model and the cascade exciton model. The calculated results are compared with the experimental data taken from the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗