Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray polarization spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility of KTa(1-x)Nb(x)O3 as a dielectric or pyroelectric microcalorimeter

We are developing a dielectric microcalorimeter for X-ray spectroscopy. We will present the results of our measurement of the dielectric permittivity, the spontaneous polarization, and the pyroelectric coefficient of the mixed-crystal quantum ferroelectric KTa(1-x)Nb(x)O3 with a doping of x = 0.012, as a function of temperature and bias voltage across the device. The effects of surface layers on the permittivity and the pyroelectric coefficient are discussed. We also show the signal results from infrared LED and alpha-particle radiation.

Pfafman, T. E.↗

E2003 + 225 - A 3h 42m AM Herculis type binary system

The bright soft X-ray source E2003 + 225, originally discovered by the HEAO 1 low-energy detectors, has been found to be a new AM Herculis type binary. The optical counterpart shows a rich emission spectrum of He II, He I, and H as well as circular and linear polarization. Larger polarization in the near-infrared than in the ultraviolet argues for its origin as high harmonic cyclotron emission. Optical photometry, polarimetry, spectroscopy, and the X-ray light curves are all consistent with an orbital period of 222.51 m, the longest period known for AM Herculis systems, and only the second on the long side of the 2-3 hour cataclysmic variable period gap.

Takalo, L. O.↗

Data reduction and analysis for the graphite crystal X-ray spectrometer and polarimeter experiment flown aboard OSO-8 spacecraft

The documentation and software programs developed for the reception, initial processing (quickbook), and production analysis of data obtained by solar X-ray spectroscopy, stellar spectroscopy, and X-ray polarimetry experiments on OSO-8 are listed. The effectiveness and sensitivity of the Bragg crystal scattering instruments used are assessed. The polarization data polarimetric data obtained shows that some X-ray sources are polarized and that a larger polarimeter of this type is required to perform the measurements necessary to fully understand the physics of X-ray sources. The scanning Bragg crystal spectrometer was ideally suited for studying rapidly changing solar conditions. Observations of the Crab Nebula and pulsar, Cyg X-1, Cyg X-2, Cyg X-3, Sco X-1, Cen X-3, and Her X-1 are discussed as well as of 4U1656-53 and 4U1820-30. Evidence was obtained for iron line emission from Cyg X-3.

Novick, R.↗

Characterization of carbon fibers and fiber-matrix adhesion in composites

The effect of fiber/matrix interactions on the mechanical properties of thermoplastic carbon fiber composites was determined. The experimental approach was a multi-faceted one involving the following areas: characterization of the surface of carbon fibers using X-ray photoelectron spectroscopy (XPS), secondary ion mass spectroscopy (SIMS) and scanning transmission electron microcopy (STEM); determination of the functional groups on carbon fiber surfaces using an elemental tagging scheme - derivatization; determination of the polar and dispersion contribution to the surface energy of carbon fibers by measuring wetting forces in a series of liquids having known polar and dispersion components; and study of the interaction of thermoplastic polymers with carbon surfaces by solution adsorption, STEM and fiber critical length.

Wightman, J. P.↗

Changes in the high state of AM Herculis - A simultaneous X-ray, optical, polarimetric, and spectroscopic study

Simultaneous UBVR photometry, circular polarimetry, and high resolution spectroscopy observations (during May, 1979), coordinated with a monitor proportional counter and a solid state spectrometer, are reported for the cataclysmic variable AM Her, when it was in its normal 'high' state, where the mean visual magnitude was 12.5 mag versus 15 mag for the infrequent 'low' state. The circular polarization was always negative and had the smallest peak to peak amplitude yet reported. The emission lines He II 4686, H-beta, N III 4634, N III 4640-4641, C III 4650-4651, and He I 4713 present at least two components identified with the broad and sharp components of Greenstein at al. (1977). The radial velocity curve of the broad component shows a 50% reduction of amplitude in comparison to their values, and a third very broad component in 4686 is identified. No correlation between the optical photometry and 1-10 keV X-ray intensity was found on flickering time scales. Results of the observations are discussed within the framework of models with accretion onto one or both magnetic poles of the white dwarf.

Crosa, L.↗

Columbia University OSO-8 instrument for stellar and solar X-ray spectroscopy and polarimetry

A spectrometer and a polarimeter consisting of large-area panels of mosaic crystals have been constructed and prepared for use in the OSO-8 satellite. The instrumentation is planned for study of stellar and solar X-ray spectra between 1.8-8 keV and stellar X-ray polarization at 2.6 keV. Aspects of the design which enable the instrument to make measurements of the diverse range of stellar and solar phenomena are described. Some of the unique features, such as high sensitivity, high temporal resolution, and spectral range, are discussed. The applicability of the spectrometer and polarimeter to various current problems in X-ray astronomy is considered.

Wolff, R. S.↗

Galactic X-ray polarimetry and high-resolution X-ray spectroscopy.

Stellar X-ray spectroscopy and polarimetry are discussed in terms of the source parameters that can be determined through such studies and in terms of the constraints that these studies will place on theoretical models. The spectroscopic and polarimetric results that have been obtained to date are reviewed. These include the recent discovery of X-ray polarization in the Crab Nebula and the recent evidence for X-ray coronal line emission in the Cygnus Loop. Finally, the properties and predicted performance of a number of satellite-borne spectrometers and polarimeters are presented.

Novick, R.↗

The optical counterpart of the X-ray source H0253+193 - A distant, high-luminosity RS Canum Venaticorum system

Optical and near-infrared photometry in the VRIJHK and CO (2.35 microns) bands and optical spectroscopy and polarimetry reveal that the optical counterpart of the X-ray source H0253+193 is most likely a RS CVn binary system. The results show a visual extinction of 11.3 mag to the star, with an IR excess possibly due a cooler binary companion or circumstellar material. It is suggested that the I-band polarization of 8.1 + or - 1.8 may be induced in the starlight by passage through the molecular cloud. The lack of strong H-alpha emission in the optical spectrum argues against the possibility of a classical T Tauri star, and the IR excess argues against a naked T Tauri star. The wide energy spectrum found in the dereddened optical and near-infrared photometry supports the binary star model.

Clemens, Dan P.↗

Surface characterization and adhesion of oxygen plasma-modified LARC-TPI

LARC-TPI, an aromatic thermoplastic polyimide, was exposed to an oxygen plasma as a surface pretreatment for adhesive bonding. Chemical and physical changes which occurred in the polyimide surface as a result of the plasma treatment were investigated using X-ray photoelectron spectroscopy (XPS), infrared reflection-absorption spectroscopy (IR-RAS), contact-angle analysis, ellipsometry, and high resolution SEM. A 180-deg peel test with an acrylate-based pressure sensitive adhesive as a flexible adherent was utilized to study the interactions of the plasma-treated polyimide surface with other polymeric materials. The surface characterization and adhesion testing results showed that the oxygen plasma treatment, while creating a more hydrophilic, polar surface, also caused chain scission, resulting in the formation of a weak boundary layer which inhibited adhesion.

Chin, J. W.↗

Consequences of hot gas in the broad line region of active galactic nuclei

Models for hot gas in the broad line region of active galactic nuclei are discussed. The results of the two phase equilibrium models for confinement of broad line clouds by Compton heated gas are used to show that high luminosity quasars are expected to show Fe XXVI L alpha line absorption which will be observed with spectrometers such as those planned for the future X-ray spectroscopy experiments. Two phase equilibrium models also predict that the gas in the broad line clouds and the confining medium may be Compton thick. It is shown that the combined effects of Comptonization and photoabsorption can suppress both the broad emission lines and X-rays in the Einstein and HEAO-1 energy bands. The observed properties of such Compton thick active galaxies are expected to be similar to those of Seyfert 2 nuclei. The implications for polarization and variability are also discussed.

Kallman, T.↗

Consequences of hot gas in the broad-line region of active galactic nuclei

Models for hot gas in the broad line region of active galactic nuclei are discussed. The results of the two phase equilibrium models for confinement of broad line clouds by Compton heated gas are used to show that high luminosity quasars are expected to show Fe XXVI L alpha line absorption which will be observed with spectrometers such as those planned for the future X-ray spectroscopy experiments. Two phase equilibrium models also predict that the gas in the broad line clouds and the confining medium may be Compton thick. It is shown that the combined effects of Comptonization and photoabsorption can suppress both the broad emission lines and X-rays in the Einstein and HEAO-1 energy bands. The observed properties of such Compton thick active galaxies are expected to be similar to those of Seyfert 2 nuclei. The implications for polarization and variability are also discussed.

Kallman, T.↗

Nuclear techniques in studies of condensed matter

Nuclear techniques have played an important role in the studies of materials over the past several decades. For example, X-ray diffraction, neutron diffraction, neutron activation, and particle- or photon-induced X-ray emission techniques have been used extensively for the elucidation of structural and compositional details of materials. Several new techniques have been developed recently. Four such techniques are briefly reviewed which have great potential in the study and development of new materials. Of these four, Mossbauer spectroscopy, muon spin rotation, and positron annihilation spectroscopy techniques exploit their great sensitivity to the local atomic environments in the test materials. Interest in synchrotron radiation, on the other hand, stems from its special properties, such as high intensity, high degree of polarization, and high monochromaticity. It is hoped that this brief review will stimulate interest in the exploitation of these newer techniques for the development of improved materials.

Singh, Jag J.↗

Transmission X-ray diffraction grating alignment using a photoelastic modulator

A high-resolution alignment technique which utilizes the partial polarization property of fine period transmission gratings has been developed. It is especially useful when the grating period is sufficiently small so that there are no visible diffracted orders. This technique uses a photoelastic modulator (PEM) to produce an intensity signal that is proportional to the sine of twice the angle between the grating lines and the PEM crystal axis. The experimentally demonstrated resolution of this technique on 200-nm period gold transmission gratings is better than 1 arc sec. This technique was developed to align X-ray transmission gratings for spectroscopy and interferometry applications.

Anderson, Erik H.↗

Two X-ray-selected BL Lacertae objects observed with the HEAO 1 scanning modulation collimator

Two 16th magnitude BL Lac objects, H1101 - 232 and H1426 + 428, have been discovered. Each is a persistent and relatively bright X-ray source. A 2.7 percent linear polarization is measured in the optical emission or H101 - 232. The X-ray identification of H1426 + 428 is confirmed in an Exosat observation. The X-ray spectrum is well-modeled by a power law with an energy index of 1.19. Both BL Lac objects exhibit high f(x)/f(opt) ratios and they show a distinct resemblance to other X-ray selected BL Lac objects. The host galaxies are about 18th mag with angular diameters of about 20 arcsec and each may be the dominant member of a cluster of galaxies. Additional wide-slit spectroscopy reveals faint absorption features with redshifts of 0.129 for H1426 + 428 and 0.186 for H1101 - 232. The implied X-ray and optical luminosities exceed 10 to the 45th ergs/s for both BL Lac nuclei, assuming isotropic emission.

Remillard, R. A.↗

Determination of physical and chemical states of lubricants in concentrated contacts, part 2

Infrared emission spectroscopy through a window in an operating bearing continued to provide most of the information gathered on the state of lubricants subjected to elastohydrodynamic (EHD) conditions. Other measurements were traction, scanning electron microscopy and elemental surface analysis X-rays. A very significant finding was the decomposition of a naphthenic oil lubricant in the presence of small concentrations of an organic chloride. Olefins and aromatics were formed in ever increasing amounts prior to total lubricant failure. An aromatic fluid also failed in the presence of chloride. A correlation was found between changes of the alignment of lubricant molecules evidence by infrared polarization and changes of traction under varying EHD stresses.

Lauer, J. L.↗

Finding the rarest objects in the universe: A new, efficient method for discovering BL Lacertae objects

We present a new, efficient method for discovering new BL Lac Objects based upon the results of the Einstein Extended Medium Sensitivity Survey (EMSS). We have found that all x-ray selected BL Lacs are radio emitters, and further, that in a 'color-color' diagram (radio/optical and optical/x-ray) the BL Lac Objects occupy an area distinct from both radio loud quasars and the radio quiet QSOs and Seyferts which dominate x-ray selected samples. After obtaining radio counterparts via VLA 'snapshot' observations of a large sample of unidentified x-ray sources, the list of candidates is reduced. These candidates then can be confirmed with optical spectroscopy and/or polarimetry. Since greater than 70 percent of these sources are expected to be BL Lacs, the optical observations are very efficient. We have tested this method using unidentified sources found in the Einstein Slew Survey. The 162 Slew Survey x-ray source positions were observed with the VLA in a mixed B/C configuration at 6 cm resulting in 60 detections within 1.5 position error circle radii. These x-ray/optical/radio sources were then plotted, and 40 BL Lac candidates were identified. To date, 10 candidates have been spectroscopically observed resulting in 10 new BL Lac objects! Radio flux, optical magnitude, and polarization statistics (obtained in white light with the Steward Observatory 2.3 m CCD polarimeter) for each are given.

Stocke, John↗

Use of high L.E.T. radiation to improve adhesion of metals to polytetrafluoroethylene

MgK alpha X-rays (1254 eV) and 2 keV electrons irradiate the surface of polytetrafluoro ethylene (PTFE). The damage is confined to a few tenths of a micron below the surface, and the doses exceed 10 to the eight power rad. X-ray Photoelectron Spectroscopy (XPS) of the irradiated surfaces and mass spectroscopy of the gaseous products of irradiation indicate that the damaged layer is crosslinked or branched PTFE. After either type of irradiation, the surface has enhanced affinity for metals and a lower contact angle with hexadecane. Tape pull tests show that evaporated Ni and Au films adhere better to the irradiated surface. XPS shows the Ni interacts chemically with PTFE forming NiF2 and possibly NiC. However, the gold adhesion and contact angle results indicate that the interaction is, at least in part, chemically nonspecific. Decreased contact angles on FEP Teflon crystallized against gold were attributed to either the presence of a polar oxygen layer or increased physical forces due to greater density. In the case of irradiated PTFE, no oxygen on the surface was observed. The crosslinked structure might, however, have a greater density, thus accounting for the observed increase in adhesion and wettability.

Wheeler, D. R.↗

Use of particle beams for lunar prospecting

A key issue in choosing the appropriate site for a manned lunar base is the availability of resources, particularly oxygen and hydrogen for the production of water, and ores for the production of fuels and building materials. NASA has proposed two Lunar Scout missions that would orbit the Moon and use, among other instruments, a hard X-ray spectrometer, a neutron spectrometer, and a Ge gamma ray spectrometer to map the lunar surface. This passive instrumentation will have low resolution (tens of kilometers) due to the low signal levels produced by natural radioactivity and the interaction of cosmic rays and the solar wind with the lunar surface. This paper presents the results of a concept definition effort for a neutral particle beam lunar mapper probe. The idea of using particle beam probes to survey asteroids was first proposed by Sagdeev et al., and an ion beam device was fielded on the 1988 Soviet probe to the Mars moon Phobos. During the past five years, significant advances in the technology of neutral particle beams (NPB) have led to a suborbital flight of a neutral hydrogen beam device in the SDIO-sponsored BEAR experiment. An orbital experiment, the Neutral Particle Beam Far Field Optics Experiment (NPB-FOX) is presently in the preliminary design phase. The development of NPB accelerators that are space-operable leads one to consider the utility of these devices for probing the surface of the Moon using gamma ray, X-ray, and optical/UV spectroscopy to locate various elements and compounds. We consider the utility of the NPB-FOX satellite containing a 5-MeV particle beam accelerator as a probe in lunar orbit. Irradiation of the lunar surface by the particle beam will induce secondary and back scattered radiation from the lunar surface to be detected by a sensor that may be co-orbital with or on the particle beam satellite platform, or may be in a separate orbit. The secondary radiation is characteristic of the make-up of the lunar surface. The size of the spot irradiated by the beam is less than 1 km wide along the ground track of the satellite, resulting in the potential for high resolution. The fact that the probe could be placed in polar orbit would result in global coverage of the lunar surface. The orbital particle beam probe could provide the basis for selection of sites for more detailed prospecting by surface rovers.

Toepfer, A. J.↗