At least 19 records

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers↗

Microstructurally informed synchrotron x-ray analysis revealing helium defect transitions in ultrafine grained tungsten

The formation of insoluble gaseous defects in materials due to nuclear transmutation or ion implantation involves the diffusion of impurity atoms to form atomic defect clusters that coalesce into bubbles or cavities and ultimately degrade the material properties. Transmission electron microscopy (TEM) is limited in its ability to resolve sub-nanometer gas clusters whereas X-ray diffraction (XRD) provides information pertaining to local atomic changes. Here, in this study, helium (He) implanted ultrafine grained tungsten is explored through a multimodal defect characterization campaign combining TEM-informed Small Angle X-ray Scattering (SAXS) analysis, XRD lattice parameter measurements, and nanoscale He cluster quantification from a region of reciprocal space accessible via Wide Angle X-ray Scattering (WAXS). Moderate elevated temperature implantations are shown to produce high concentrations of sub-nanoscale He clusters and small, homogeneously distributed cavities, which collectively are linked to lattice expansion and further substantiated through complementary atomistic simulations. Increased implantation temperatures encourage the diffusion of these defects to the grain boundaries (GBs), leading to lattice relaxation and the growth of large GB cavities manifesting as bimodal size distributions in the SAXS analysis. Overall, our results demonstrate the utility of multimodal synchrotron X-ray analysis in bridging the gap between microscale He cavity quantification and atomic-scale defect analysis.

36 MATERIALS SCIENCE↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Corrosion susceptibility and chromium loss in Austenitic steels and Nickel-based alloys in molten FLiNaK at 700 °C

A comparative study was conducted to evaluate the corrosion susceptibility of 316L, 316H, Ni 200, Inconel 625, and Hastelloy N in molten FLiNaK at 700 °C for 100 h. Top-view and cross-sectional scanning electron microscopy (SEM) imaging, combined with energy-dispersive X-ray spectroscopy (EDS) mapping, was performed to investigate microstructural and compositional changes. SEM images were further processed by introducing a contrast threshold to map cavity distribution. Using EDS mapping, intergranular and intragranular Cr loss were separately characterized. The ranking of mass loss after corrosion, from highest to lowest, is as follows: 316H > 316L > Inconel 625 > Hastelloy N > Ni 200. Cr loss was found to be correlated with Mo concentration, in agreement with many previous studies, with higher Mo content resulting in reduced Cr loss. On the other hand, there is no evidence that the high carbon content in 316H enhances corrosion resistance. The relatively low solubility of carbon in austenite at the testing temperature limits the amount of dissolved carbon. Therefore, the carbon-retarded vacancy diffusion, and consequently the reduced Cr diffusion, were not observed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

APS upgrade: Commissioning the world’s first light source based on swap-out injection

The Advanced Photon Source (APS) has recently completed a major upgrade, replacing its 25-year-old storage ring with a cutting-edge hybrid seven-bend achromat lattice enhanced by six additional reverse bends. The new design achieves a natural emittance of 42 pm-rad, enabling the production of X-rays up to 500 times brighter than those generated by the original APS. A key innovation of the upgrade is the implementation of a swap-out injection scheme, which replaces entire depleted bunches instead of performing traditional top-up injection. This approach enables on-axis injection to accommodate for the reduced dynamic aperture resulting from strong focusing. This paper outlines the commissioning process, shares initial operating experience with swap-out injection, and presents performance data for new systems such as the bunch-lengthening cavity.

Sajaev, Vadim [Argonne, PHY]↗

Irradiation Driven Restructuring of Nanocrystalline ThO 2 and Th 1–x U x O 2 Thin Films

Irradiation induced structural changes of actinide oxide materials is a key consideration in their development and use as nuclear fuels. This study reported on the synthesis of ThO 2 and Th 1–x U x O 2 (x = 0.15, 0.50) thin films, fabricated using electrospray-assisted solution combustion synthesis, and their responses to ion irradiation. Krypton ion irradiations, up to a fluence of 1 × 10 16 ions/cm 2 , were carried out to simulate radiation damage induced by fission products in a reactor environment. Structural and chemical changes induced by irradiation were analyzed using high-resolution scanning transmission electron microscopy (STEM), energy-dispersive X-ray spectroscopy (EDS), and electron energy-loss spectroscopy (EELS). It was determined that the extent and nature of irradiation-induced damage are strongly correlated with the uranium content. ThO 2 films were most susceptible to radiation-induced damage, with significant cavity formation and delamination from the substrate at high fluence. Of the compositions studied, Th 0.85 U 0.15 O 2 films showed the highest stability, characterized by moderate grain growth and the absence of voids or severe defect structures. In contrast, Th 0.5 U 0.5 O 2 films accumulated extensive damage, including the formation of a nanocrystalline central region. EELS analysis indicated that oxygen displacement is the primary driver of structural degradation in Th 0.5 U 0.5 O 2 films. α-particle spectroscopy confirmed minimal actinide loss across all compositions, underscoring the mechanical robustness of the films. These findings provide insight into the irradiation-induced damage mechanisms in Th O2 and Th 1–x U x O 2 systems, supporting their development as potential materials for nuclear fuels and irradiation-tolerant thin film targets in nuclear physics measurements.

Th1−xUxO2↗

Comparative neutron-irradiation effects on thermal conductivity degradation and dimensional stability of TiC, TiB 2 , and ZrB 2 at 200–1000 °C

Ultra-high-temperature ceramics (UHTCs), including TiC, Ti 11 B₂, and Zr 11 B₂, show great potential for plasma-facing components due to their excellent high-temperature properties prior to irradiation. However, their response to neutron irradiation remains insufficiently understood, limiting robust assessment of their viability for fusion energy applications. Here, this study examines the thermal conductivity, dimensional stability and microstructure of TiC, TiB₂, and ZrB₂ following neutron irradiation at temperatures of 200–1000 °C and fast neutron fluences of 2.0 × 10 25 to 1.1 × 10 26 n/m 2 (E > 0.1 MeV). Lattice swelling measured by synchrotron X-ray diffraction in all three UHTCs was maximized at 200 °C and decreased with increasing irradiation temperature, with no evidence of amorphization observed at 200 °C. Above 600 °C, significant macroscopic volume swelling was observed in irradiated Ti 11 B₂ and Zr 11 B₂, but not in TiC, likely due to cavity formation in the diborides. The post-irradiation thermal conductivity, measured at the irradiation temperature, ranged from 28 to 45 W/m·K, representing a 34–45% reduction relative to the unirradiated material. Notably, neutron-irradiated UHTCs exhibit recoverable thermal conductivity at elevated temperatures, comparable to ferritic–martensitic steels and potentially superior to W when transmutation effects are considered, highlighting promise for shielding or armor plasma-facing components. At 600 °C, both thermal conductivity degradation and lattice swelling saturated at doses exceeding 2–4 dpa.

fusion materials↗

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]↗

Ta–Zr carbides: Synthesis advances via carbothermal reduction and defect evolution observed through transmission electron microscopy ion irradiation

The thermodynamic stability of six distinct compositions within the Zr—Ta—C ternary system is investigated in this study, marking the first report of their synthesis through carbothermic reduction in vacuum. A prolonged annealing process at 2200°C enabled high densification and phase equilibrium. Detailed phase identification and microstructural characterization through microscopy and X-ray diffraction techniques revealed clear compositional trends and stable phase formations. Two compositions ((Ta 0.2 Zr 0.8 )C 0.6 and (Ta 0.5 Zr 0.5 )C 1 ) were selected for ion irradiation experiments using 200 keV Kr + at 600°C—representing the first-ever irradiation study on the Zr—Ta—C system. The findings indicated defect accumulation and nanoscale cavity formation without any evidence of amorphization, highlighting the system's structural stability under irradiation. Together, the synthesis and irradiation results provide a basis for further investigation of the system and suggest its relevance for applications under extreme environments.

36 MATERIALS SCIENCE↗

Correlating Surface Processing of Nb Superconducting RF Cavities with the Evolution of Surface Electronic States

Superconducting-radio frequency (RF) cavities provide an efficient way to accelerate particle beams with extremely high acceleration gradients while generating very small power dissipation. The few nanometers of the surface play a critical role in defining the RF performance of superconducting Nb based cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in superconducting cavity performance by simultaneously achieving high quality factors with increasing maximum acceleration gradients. These processing approaches include chemical polishing, distinct multi-step thermal treatments under ultra-high vacuum (UHV) conditions over low to high temperature regimes, as well as high-temperature treatments under controlled nitrogen atmospheres. Beyond their macroscopic impact on RF performance, these methods produce distinct surface oxide configurations characterized by different valence states, oxide thicknesses, chemical uniformity, and oxygen concentration profiles extending into the near-surface bulk of niobium. In this work, we are trying to understand how the surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity. Using a combination of X-ray photoemission and X-ray absorption spectroscopies, we investigate how the valence-band structure and the electronic density of states (DoS) near the Fermi level evolve under different surface treatments. By employing tunable photon energies across multiple elemental absorption edges, we use resonant photoemission to disentangle and identify the elemental contributions to specific valence-band features. Our observations show that different surface-processing methods lead to distinct temperature evolutions of the DoS and valence-band states near the Fermi level. Our results suggest variations in different Nb-O orbital hybridizations in distinct processes and point towards the possibility of different underlying mechanisms of superconductivity governed by surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in superconducting RF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of superconducting RF cavities.

Tripathi, Malvika [Fermilab] (ORCID:00000001989251↗

Structural Investigation of Six Quinary Sulfides Synthesized via the Flux-Assisted Boron-Chalcogen Mixture (BCM) Method: Eu 2+ Containing Members of the RE 3 MTQ 7 (M and T = Transition or Main Group Metals, Q = Chalcogens) Family

For this work, a series of six quinary rare-earth sulfides Ce 4+ 1.85 Eu 2+ 1.15 Na 0.30 SiS 7 , Ce 4+ 1.91 Eu 2+ 1.09 K 0.18 SiS 7 , Ce 4+ 1.96 Eu 2+ 1.04 Rb 0.08 SiS 7 , Ce 4+ 1.98 Eu 2+ 1.02 Cs 0.05 SiS 7 , Ce 4+ 1.97 Eu 2+ 1.03 Ag 0.06 SiS 7 , and Ce 4+ 1.50 Eu 2+ 1.50 CuSiS 7 were obtained in an alkali iodide flux using the boron-chalcogen mixture (BCM) method. Single crystal X-ray diffraction was used to determine the structures of the high quality single crystals that were grown; their elemental compositions were confirmed by energy-dispersive spectroscopy (EDS). The compounds crystallize in the hexagonal crystal system in the noncentrosymmetric space group P63. The crystal structure consists of a three-dimensional network composed of mixed cerium and europium bicapped trigonal prisms, isolated SiS4 tetrahedra, and monovalent metals (Na, K, Rb, Cs, Ag, and Cu) located in cavities created by linked Ce/EuS 8 polyhedra. The structures are charge-balanced when Ce and Eu are in their +4 and +2 oxidation states, respectively. The effective magnetic moment of Ce 1.50 4+ Eu 1.50 2+ CuSiS 7 determined from the temperature dependence of the magnetic susceptibility data is consistent with the presence of Ce 4+ and Eu 2+ . Clear correlations between the alkali ion site occupancy, the ionic radius of the alkali cations, and the average bond length of Ce 4+ /Eu 2+ –S, were established. UV–vis diffuse reflectance data were collected for Ce 1.50 4+ Eu 1.50 2+ CuSiS 7 and a band gap of 1.9(1) eV was established.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN↗

Controlling Oxidation of Nb in Oxygen Abundant Environments

Modern particle accelerators depend on Superconducting Radio Frequency (SRF) cavities made from high-purity niobium (Nb) to achieve optimal performance, including high quality factors and strong accelerating gradients. However, when exposed to air, niobium naturally forms a complex oxide layer that can introduce surface imperfections and carbon contamination. This work examines an alternative oxidation strategy under oxygen-rich conditions to better regulate the oxide formation process. The ultimate objective is to improve surface uniformity and cleanliness, thereby reducing defect density and enhancing performance. We used Confocal Microscopy, Scanning Electron Microscopy (SEM), and X-Ray Photoelectron Spectroscopy (XPS) to analyze surface changes. We used standard metrics, like Arithmetic Average Roughness (Ra) and Root Mean Square (Rq). Three oxidation methods were applied: short, extended, and a repeated HF and H₂O₂ oxidation process. Preliminary results show promising reductions in carbon contamination and surface defects.

Romero, Juan [Fermilab]↗

Controlling Oxidation of Nb in Oxygen Abundant Environments.

Superconducting Radio Frequency (SRF) cavities, the core of modern particle accelerators, rely on high-purity niobium (Nb) to achieve high quality factors and accelerating gradients. However, native oxidation in ambient conditions introduces a complex oxide layer with increased surface defects and contamination, particularly from carbon. This research explores a controlled oxidation processes in an oxygen-abundant environment to try to control this complex oxide stack, with the goal of improving surface purity and uniformity. Using standard surface preparation techniques—including electropolishing, vacuum baking, and sonication—followed by a custom oxidation protocol, we compared structural and chemical changes through Confocal Microscopy, Scanning Electron Microscopy (SEM), and X-Ray Photoelectron Spectroscopy (XPS). Results show that iterative oxidation cycles can significantly reduce carbon-related defects, even without baking. Aditionally, baked samples with a specific oxidation technique demonstrated a measurable 25\% decrease in carbide formation.

Romero, Juan [Fermilab]↗

Kinematic Evidence for Bipolar Ejecta Flows in the Galactic Supernova Remnant W49B

W49B is a unique Galactic supernova remnant with centrally peaked, “bar”-like ejecta distribution, which was once considered evidence for a hypernova origin that resulted in a bipolar ejection of the stellar core. However, chemical abundance measurements contradict this interpretation. Closely connected to the morphology of the ejecta is its velocity distribution, which provides critical details for understanding the explosion mechanism. We report the first ever observational constraint on the kinematics of the ejecta in W49B using the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Using XRISM/Resolve, we measured the line-of-sight velocity traced by the Fe Heα emission, which is the brightest feature in the Resolve spectrum, to vary by ±300 km s −1 with a smooth east-to-west gradient of a few tens of kilometers per second per parsec along the major axis. Similar trends in the line-of-sight velocity structure were found for other Fe-group elements Cr and Mn, traced by the Heα emission, and also for intermediate-mass elements Si, S, Ar, and Ca, traced by the Lyα emission. The discovery of the east–west gradient in the line-of-sight velocity, together with the absence of a twin-peaked line profile or enhanced broadening in the central region, clearly rejects the equatorially expanding disk model. In contrast, the observed velocity structure suggests bipolar flows reminiscent of a bipolar explosion scenario. An alternative scenario would be a collimation of the ejecta by an elongated cavity sculpted by bipolar stellar winds.

High resolution spectroscopy↗