Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography

X-ray characterization of fully-depleted p-channel Skipper-CCDs for the DarkNESS mission

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) mission is a 6U CubeSat designed to search for X-ray lines from decaying dark matter using Skipper-CCDs. Thick, fully-depleted p-channel Skipper-CCDs provide low readout noise and high quantum efficiency for 1-10 keV X-rays, but their X-ray performance has not yet been demonstrated in the space environment. DarkNESS will operate in low-Earth orbit, where trapped protons induce displacement damage in the sensor that increases charge-transfer inefficiency and degrades the X-ray energy resolution. This work measures the X-ray line response of Skipper-CCDs before and after proton irradiation and quantifies the associated degradation. A sensor was exposed to 217 MeV protons at a fluence of 8.4 x 10^10 protons cm^-2, corresponding to a displacement-damage dose more than an order of magnitude above the three-year expectation for representative mid-inclination and Sun-synchronous low-Earth orbits. A 55Fe source was used to compare the energy resolution of the beam-exposed quadrant to adjacent unexposed quadrants and a non-irradiated reference sensor. These measurements provide a quantitative assessment of radiation-induced spectral degradation in Skipper-CCDs and enable an estimate of the end-of-life X-ray energy resolution expected for DarkNESS operation in low-Earth orbit.

Alpine, Phoenix [Illinois U., Urbana] (ORCID:00090

On the Necessity of Adopting Irradiation Protocols Recommended by the Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER) in Published Research and Why It Matters to Health Physicists

The National Nuclear Security Administration (NNSA) seeks to assist and support all partners in the fields of radiobiology, health physics, radiation physics, and related areas to transition from cesium-137 chloride-based technologies that can potentially be used in an act of terrorism to X-ray technologies. The absence of information on experimental procedures, equipment, and irradiation parameters directly and negatively impacts the reproducibility and translatability of a sizable portion of radiation biology studies. It also discourages researchers from adopting new tools that eliminate the risks of a radiological dispersal device.

Stern, Warren [Brookhaven National Laboratory (BNL

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION

MPEX AI Digital Twins

All magnetically confined plasma fusion power plant concepts (Tokamak, Spherical Tokamak, Stellarator, Mirror, ...) must exhaust the heat and plasma from the core confinement region to the material walls. The primary channel for this exhaust is through a plasma divertor which directs plasma along open magnetic field lines to a material target. The Material Plasma Exposure eXperiment (MPEX) illustrated in Figure 1, is a high-power, steady-state linear plasma device designed to produce the plasma material interaction (PMI) conditions of the divertor of future magnetic confinement fusion power plants: energy flux 20MW/m 2 , ion fluence 1031/m 2 , pulse duration 106 sec. These goals of plasma exposure in MPEX are well beyond those achieved in magnetic fusion experimental devices. Successfully achieving these high power steady state conditions for long pulses requires operational control of the heating and particle sources and the plasma flux to the walls and target. The MPEX AI Hot Spot Controller, proposed in this project, will help achieve the operational milestones of MPEX. The MPEX device will begin commissioning at the end of FY26. A smaller proto-MPEX was operated for 14,666 plasma discharges and will resume operation in September of 2025 as proto-MPEX-lite, with reduced capability, to test a new window for the Helicon plasma source. The proto-MPEX data has undergone surrogate modeling with machine learning methods (R. Archibald, 2022 IEEE International Conference on Big Data). This proto-MPEX data will be used to begin development of the AI digital twins described in this white paper. The scientific mission of MPEX is to qualify materials of different composition for use in the high energy and plasma flux conditions of a fusion power plant. The materials exposed in MPEX will in some cases be exposed to high neutron fluxes at other ORNL facilities to measure the changes to their PMI properties. The targets exposed in MPEX will be transported under vacuum to a Surface Analysis Station (SAS). The SAS will be equipped with the following diagnostics: Focused Ion Beam (FIB) for trench milling, 100-400 angstrom resolution scanning electron microscope (SEM), surface mapping x-ray spectrometer, high resolution camera, and a future upgrade to a laser induced breakdown spectroscopy quadruple mass spectrometer (LIBS-QMS). The MPEX experiments will generate diverse pre- and post-exposure measurement data of detailed material properties down to the crystal grain level in 3D for post-exposure assessment of PMI damage (e.g. cracking, melting, erosion and redeposition of the material). Physics models for the PMI, and how the material composition and manufacturing impact its performance under high energy plasma exposure, need to be validated with MPEX data to guide the selection of new candidate materials. Our vision for the MPEX AI Digital Twins project is to supply experimental and physics model simulation data to train Artificial Intelligence (AI) models for data processing, analysis, operational control, PMI and materials simulation to maximize the scientific output of the MPEX device. Ultimately, an AI digital twin of MPEX material assessment metrics for tested and synthetic material types with simulated PMI will be trained by the AI Modeling Teams on the experimental and physics simulation data submitted to the American Science Cloud by this project. A purely empirical search for the best material is inefficient given the finite number of samples that can be tested on MPEX. In order to expand the material properties database for training the MPEX Material Assessment AI Digital Twin, and to gain physics understanding of the PMI processes, physics models of the material properties and PMI processes are required. The physics simulations provide detailed simulation data, like impact angles for plasma ions, sputtering yields, transport of the ionized sputtered target material in the plasma, and redeposition locations. This simulation data expands the measurement data for deeper physics understanding. The experimental data is essential to validate the PMI and material structure simulation models. The validated models can then be used to generate new simulation data of MPEX material assessments for synthetic material compositions that have not been exposed in MPEX. These predictive simulations, plus the whole experimental dataset, will be used to train the MPEX Material Assessment AI Digital Twin allowing a rapid generative AI search for new materials with reduced PMI damage by interpolating the domain of the training set. These new optimum materials can be simulated with the physics codes and/or tested in MPEX. The ability of AI neural networks to interpolate multi-dimensional parameter spaces and generate virtual data is exploited for a more efficient search for optimum materials. The advent of the Transformational AI Models Consortium (TAIMC) is an opportunity to engage with state of the art private and public AI developers to achieve the goals of the AI digital twins and AI accelerated physics models proposed in this project. Our partners at ORNL from the Advance Scientific Computing Research (ASCR) organization will collaborate in accelerating the integrated plasma material interaction simulation framework. This simulation framework will provide a platform for generating simulation data across a range of physical fidelities, including hybrid methods that produce multi-fidelity results. This data will be leveraged for AI model development, both for generation of surrogates and the automation of simulation campaigns. A part of the research below will include collaborative efforts with the TAIMC to (i) adapt data storage approaches to ensure AI-readiness, (ii) provide a protypical exemplar to inform and exercise constructed workflows, and (iii) generate and share data, using the TAIMC unified AI data standard, for foundational models that will be trained from multiple sources across the DOE complex. We will also collaborate with the TAIMC, as well as the planned AI modeling teams, to develop approaches for reducing the cost of data generation. These include tailored multi-fidelity approaches as well as fine-tuning strategies to augment general, large-scale foundational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED

DarkNESS: A skipper-CCD nanosatellite for dark matter searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace’s DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). As a result, this will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

Alpine, Phoenix [University of Illinois, Urbana-Ch

Effect of moisture ingression on material performance and particle generation in molten salts

This report summarizes activities conducted to understand and mitigate the negative consequences that moisture ingressions have upon the operations of pyroprocessing equipment. The objectives of the work conducted in FY25 were to characterize (1) the physicochemical properties of particles generated as a result of moisture ingressions, and (2) the corrosion of relevant structural materials with the introduction of moisture. Compositional and morphological analyses of the generated particles were conducted through a suite of characterization technologies, including X-ray diffraction, microscopy, and particle size analysis. The results gathered this year were compared to those obtained in FY24 when studies with oxygen ingressions were conducted on CeCl 3 -LiCl-KCl and UCl 3 -LiCl-KCl systems. Investigations involving performance evaluations of industrially relevant structural alloys were also conducted under moisture ingress conditions. In-line electrochemical monitoring of the bulk salt was augmented with microscopy of alloy samples to quantify the concentration and accumulation of corrosion products in the bulk salt. The results reported in this work provide a more holistic understanding of the effects of atmospheric ingressions on molten chloride salt chemistry such that effective redox control strategies may be implemented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development of PNNL’s Plutonium Metallography Capability

The goal of this project was to develop plutonium metallography capabilities and establish workflows for characterization at PNNL’s Radiological Processing Facility (RPL). Developing and expanding on this capability opens more opportunities for PNNL to better support science through collaborations with other labs, plants, and sites withing the Department of Energy Complex and through programs within the National Nuclear Security Administration. This project established metallography equipment in an air glovebox, polishing protocols, as well as radiological and facility controls and procedures so that gram quantities of plutonium metal could be analyzed on multiple characterization tools. Data was collected and analyzed on two different delta phase plutonium - Gallium samples and a calciothermically reduced alpha plutonium metal using a combination of optical and electron microscopy, powder X-ray diffraction, and atom probe tomography. This report highlights the metallography capabilities, some preliminary data collections, and plans at PNNL to support plutonium material science.

36 MATERIALS SCIENCE