Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tree-based solvers for adaptive mesh refinement code $\scriptsize{FLASH}$ – IV. An X-ray radiation scheme to couple discrete and diffuse X-ray emission sources to the thermochemistry of the interstellar medium

X-ray radiation, in particular radiation between 0.1 and 10 keV, is evident from both point-like sources, such as compact objects and T-Tauri young stellar objects, and extended emission from hot, cooling gas, such as in supernova remnants. The X-ray radiation is absorbed by nearby gas, providing a source of both heating and ionization. While protoplanetary chemistry models now often include X-ray emission from the central young stellar object, simulations of star-forming regions have yet to include X-ray emission coupled to the chemo-dynamical evolution of the gas. We present an extension of the $\scriptsize{TREERAY}$ reverse ray trace algorithm implemented in the flash magnetohydrodynamic code which enables the inclusion of X-ray radiation from 0.1 keV < E γ < 100 keV, dubbed $\scriptsize{XRAYTHESPOT}$. $\scriptsize{XRAYTHESPOT}$ allows for the use of an arbitrary number of bins, minimum and maximum energies, and both temperature-independent and temperature-dependent user-defined cross-sections, along with the ability to include both point and extended diffuse emission and is coupled to the thermochemical evolution. We demonstrate the method with several multibin benchmarks testing the radiation transfer solution and coupling to the thermochemistry. Finally, we show two example star formation science cases for this module: X-ray emission from protostellar accretion irradiating an accretion disc and simulations of molecular clouds with active chemistry, radiation pressure, and protostellar radiation feedback from infrared to X-ray radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Modification of ZIF‐8 Membranes for Gas Separation Using X‐ray Radiation

Abstract We report an X‐ray radiation‐induced modification of the structure and gas permeation behavior of ZIF‐8 membranes. With 300 min irradiation time, CO 2 permeance decreases by only 9 %, while N 2 and CH 4 permeances reduce by 75 and 65 %, respectively, leading to 3.7‐ and 2.6‐fold enhancements in ideal selectivity for CO 2 /N 2 and CO 2 /CH 4 .

Lee, Dennis T.↗

Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

47 OTHER INSTRUMENTATION↗

Modification of ZIF‐8 Membranes for Gas Separation Using X‐ray Radiation

Here, we report an X-ray radiation-induced modification of the structure and gas permeation behavior of ZIF-8 membranes. With 300 min irradiation time, CO 2 permeance decreases by only 9 %, while N 2 and CH 4 permeances reduce by 75 and 65 %, respectively, leading to 3.7- and 2.6-fold enhancements in ideal selectivity for CO 2 /N 2 and CO 2 /CH 4 .

ZIF-8 membranes↗

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

Transverse oscillating bubble enhanced laser-driven betatron X-ray radiation generation

Abstract Ultrafast high-brightness X-ray pulses have proven invaluable for a broad range of research. Such pulses are typically generated via synchrotron emission from relativistic electron bunches using large-scale facilities. Recently, significantly more compact X-ray sources based on laser-wakefield accelerated (LWFA) electron beams have been demonstrated. In particular, laser-driven sources, where the radiation is generated by transverse oscillations of electrons within the plasma accelerator structure (so-called betatron oscillations) can generate highly-brilliant ultrashort X-ray pulses using a comparably simple setup. Here, we experimentally demonstrate a method to markedly enhance the parameters of LWFA-driven betatron X-ray emission in a proof-of-principle experiment. We show a significant increase in the number of generated photons by specifically manipulating the amplitude of the betatron oscillations by using our novel Transverse Oscillating Bubble Enhanced Betatron Radiation scheme. We realize this through an orchestrated evolution of the temporal laser pulse shape and the accelerating plasma structure. This leads to controlled off-axis injection of electrons that perform large-amplitude collective transverse betatron oscillations, resulting in increased radiation emission. Our concept holds the promise for a method to optimize the X-ray parameters for specific applications, such as time-resolved investigations with spatial and temporal atomic resolution or advanced high-resolution imaging modalities, and the generation of X-ray beams with even higher peak and average brightness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bifurcation-like transition of divertor conditions induced by X-point radiation in KSTAR L-mode plasmas *

Abstract Density ramps with ion grad B drift directed into lower single null KSTAR L-mode plasmas are associated with a simultaneous and abrupt reduction of the divertor particle flux on both low- and high-field-side targets when the mid-plane line averaged electron density reaches a given level. Target embedded Langmuir probe signals show a clear ‘cliff edge’ behavior similar to that observed in the divertor target electron temperature in DIII-D H-mode plasmas (Eldon et al 2017 Nucl. Fusion 57 066039; McLean et al 2015 J. Nucl. Mater. 463 533–6). The collapse of the particle flux is observed along the whole divertor target area (from private flux region to the far scrape-off layer (SOL)). The critical upstream density of this target flux cliff is invariant under fuel gas throughput modulation. The transition along the cliff occurs in tens of milliseconds. With the cliff, carbon impurities and deuterium neutrals transported through the X-point to the core produce a strong radiation spot near the X-point, seen on bolometric signals, and increase the upstream density. The experimental observations are consistent with time-dependent SOLPS-ITER simulations, which also demonstrate an abrupt transition of the target flux and upstream density with the increase in X-point radiation. The timescale of the cliff predicted by SOLPS-ITER is consistent with the experiment, although, it is influenced by gas throughput or time-dependent numerical methods. In the L-mode phase space of separatrix electron density and temperature, branches are divided based on target temperature, because the latter is strongly coupled to the radiation front and ionization front due to the monotonic characteristic of the parallel electron temperature distribution. Since the H-mode condition operates at a much higher upstream density and electron temperature in phase space, dissipation from sputtered carbon alone leads to the density limit before reaching the X-point radiation condition. This is therefore consistent with the fact that cliffs have never been observed in H-mode KSTAR experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral studies of soft x-ray radiation of laser-produced plasma of various target materials in a wide spectral range

Here, the work is devoted to experimental study of soft X-ray radiation spectra of laser produced plasma in a wide spectral range 5–100 Å at the “Kamerton” facility (GPI) with pulse duration 70 ps, pulse energy 1–5 J, wavelength 0.53 microns at which the laser intensity (power flux density) of 7×10 14 – 3.5×10 15 W/cm 2 was achieved. A spectrograph was used, which had transmission diffraction gratings with a ratio of the elementary gap to the period of the structure of 0.25 and 0.41. Detection was performed on both UV-4 X-ray photo film and Fuji TR fluorescent imaging plate. Solid samples from Al, Si, Ti, Cu, Ta and W were used as targets. The ionization states of the plasma corresponding to various electron temperatures were calculated, which made it possible to estimate the electron temperature by comparison these calculation results with the experimentally obtained spectra. The estimated electron temperature, which depends on the laser pulse energy and the target material, varied within the range of 100–450 eV. To verify the correctness of the temperature estimations obtained by such comparison a numerical simulation of plasma radiation was carried out by the use of PrismSPECT computer program. It was found that the results of this simulation are in a good agreement with estimations on the base of experimentally obtained spectra. The analysis of these spectra showed that tantalum, tungsten or titanium targets are the best candidates among the tested ones for the use of laser produced plasma as a radiation source in the "water window" spectral range (23–44 Å) for applications in biology and medicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

CsPbBr3 perovskite single crystals for X- and -radiation detectors

Methods were developed for the synthesis and growth of halide lead perovskites CsPbBr3, which can be used as detectors of optical, X-ray, and -radiation. The growth of single crystals was carried out by the Bridgman method in quartz ampoules using zone-refined starting material. The electro-physical properties of the inorganic perovskite lead cesium tribromide CsPbBr3 were studied. Two types of structures with Cr/CsPbBr3/Ni rectifying and Ni/CsPbBr3/Ni ohmic contacts were fabricated. The resistivity of (  7×109 Ohmcm), and the activation energy of the dark conductivity (E  0.8 eV) were determined. From the measurements of the optical transmission spectra, the CsPbBr3 energy gap at 300 K was found to be Еg = 2.27 eV. The temperature dependence of the forbidden gap (Eg(T) = 2.4 - 4*10-4 T, eV) was also determined. A significant increase in photosensitivity for the Cr/CsPbBr3/Ni structure was observed at elevated temperatures. The Cr/CsPbBr3/Ni structures were shown to be sensitive to -radiation. The FWHM of the energy resolution for 241Am source was measured to be 15.8 keV.

Sklyarchuk, V.↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Free-electron crystals for enhanced X-ray radiation

Abstract Bremsstrahlung—the spontaneous emission of broadband radiation from free electrons that are deflected by atomic nuclei—contributes to the majority of X-rays emitted from X-ray tubes and used in applications ranging from medical imaging to semiconductor chip inspection. Here, we show that the bremsstrahlung intensity can be enhanced significantly—by more than three orders of magnitude—through shaping the electron wavefunction to periodically overlap with atoms in crystalline materials. Furthermore, we show how to shape the bremsstrahlung X-ray emission pattern into arbitrary angular emission profiles for purposes such as unidirectionality and multi-directionality. Importantly, we find that these enhancements and shaped emission profiles cannot be attributed solely to the spatial overlap between the electron probability distribution and the atomic centers, as predicted by the paraxial and non-recoil theory for free electron light emission. Our work highlights an unprecedented regime of free electron light emission where electron waveshaping provides multi-dimensional control over practical radiation processes like bremsstrahlung. Our results pave the way towards greater versatility in table-top X-ray sources and improved fundamental understanding of quantum electron-light interactions.

47 OTHER INSTRUMENTATION↗