Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Work exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A careful examination of closure models in Euler–Lagrange Simulations of compressible multiphase flow in a planar shock particle curtain problem

In this work we present a comprehensive investigation of state-of-the-art closure models employed to represent interphase momentum, thermal, and work exchange between the gas and particulate phases for Euler–Lagrange (EL) simulations in shock-driven flows. A complete list of closures for the force, torque, heat transfer, and work exchange models is provided. In particular, the present work includes a stochastic closure for the particle-to-particle variation in the quasi-steady force and a deterministic closure for particle-to-particle variation in the added mass force in an EL framework. These variations arise due to the presence of neighboring particles and particle–particle interactions. To investigate the importance of each closure term, we carry out fully three-dimensional simulations for a planar shock propagating over a random bed of inert particles. The primary goal is to evaluate the role of each closure term on the gas dynamic features (such as transmitted and reflected shock locations) and particle curtain features (such as upstream and downstream curtain locations). To this end, thirteen cases are considered, with each case progressively including a closure model with the goal to identify and quantify its contribution to the simulated dynamics. We show that the volume fraction dependence of the mean force models plays an important role in generating wave-like instabilities that lead to concentration bands. In addition, fluctuations in quasi-steady and added mass forces primarily decrease the internal instabilities that tend to enhance local volume fraction variations. Particle rotation is primarily due to inter-particle collisions, is generally weak, and does not play an important role in the translational dynamics for the present configuration. Inter-phase heat transfer has a strong effect on gas phase temperature, slows down the transmitted and reflected shocks, and decreases the width of the curtain. Furthermore, the absence of a work-coupling model fails to conserve the total energy, greatly under-predicts the gas temperature which in turn affects the particle dynamics.

Compressible flow

Revisiting the First, Second and Combined Laws of Thermodynamics

The present study revisits the first, second, and combined laws of thermodynamics by introducing partial internal energy in the first law, entropy production and partial entropy in entropy change, and partial volume in the context of work exchange. These developments yield a more rigorous and internally consistent thermodynamic framework, within which chemical potential is defined as the partial derivative of internal energy with respect to composition at constant entropy and volume, and is related to partial internal energy, partial entropy, and partial volume.

36 MATERIALS SCIENCE

Catalytic enhancement in the performance of the microscopic two-stroke heat engine

Here we consider a model of heat engine operating in the microscopic regime: the two-stroke engine. It produces work and exchanges heat in two discrete strokes that are separated in time. The working body of the engine consists of two d-level systems initialized in thermal states at two distinct temperatures. Additionally, an auxiliary nonequilibrium system called catalyst may be incorporated with the working body of the engine, provided the state of the catalyst remains unchanged after the completion of a thermodynamic cycle. This ensures that the work produced by the engine arises solely from the temperature difference. Upon establishing the rigorous thermodynamic framework, we characterize twofold improvement stemming from the inclusion of a catalyst. Firstly, we prove that in the noncatalytic scenario, the optimal efficiency of the two-stroke heat engine with a working body composed of two-level systems is given by the Otto efficiency, which can be surpassed by incorporating a catalyst with the working body. Secondly, we show that incorporating a catalyst allows the engine to operate in frequency and temperature regimes that are not accessible for noncatalytic two-stroke engines. We conclude with a general conjecture about the advantage brought by a catalyst: including the catalyst with the working body always allows to improve efficiency over the noncatalytic scenario for any microscopic two-stroke heat engines. We prove this conjecture for two-stroke engines where the working body is composed of two d-level systems initialized in thermal states at two distinct temperatures, as long as the final joint state leading to optimal efficiency in the noncatalytic scenario is not a product state, or at least one of the d-level system is not thermal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Organic Cation Influence on Organic–Inorganic Thermal Equilibration within 2D Metal Halide Perovskites

Two-dimensional inorganic–organic lead halide perovskites exhibit tunable optoelectronic properties that are dictated by alternating layers of metal halide octahedra and organic cations. In such hybrid materials, vibrational coupling and thermalization between the low mass, insulating, organic cation spacers, and high mass inorganic octahedra remains poorly understood. Here, in this study, using femtosecond infrared-pump electronic-probe (IPEP) spectroscopy, we investigate the role of organic cation identity regarding the kinetics of vibrational energy exchange and sublattice mechanical coupling. Linear aliphatic cation-containing 2D perovskites with 4, 6, or 8 carbons (butylammonium = BA, hexylammonium = HA, and octylammonium = OA) were produced as thin films and mid-infrared pump pulses and then selectively excited organic cation stretch vibrations. Thermal energy introduction was evaluated via visible-wavelength optical probing that conveys inorganic octahedra response, owing to changes in electronic absorption. Multiple distinct spectral shifts appear upon excitation of the organic cations. Following an initial optical Stark shift caused by pump–probe temporal overlap, a redshift occurs within the first 10 ps that we attribute to compression of the octahedra by the expanded organic layers. Subsequently, a blueshift of the bandgap occurs commensurate with equilibration of both sublattices at an elevated temperature with a time constant of 21.8 to 31.6 ps depending on the spacer identity, with thermal energy transfer slowing by nearly 50% for the longest linker. By examining the effect that altered cation identity has on vibrational energy exchange, this work begins to offer routes to tune nonequilibrium response as well as provides insight into the fundamental impacts of organic spacers on thermal energy exchange in perovskite materials.

Peifer, Shoshanna E. [Northwestern Univ., Evanston

Water-In-Glass: A Self-Supporting Inorganic Aqueous Electrolyte

Aqueous rechargeable sodium-ion batteries (ARNIBs) are emerging as cost-effective and safe candidates for large-scale energy storage applications. However, their advancement has been constrained by the narrow electrochemical stability window (ESW) of conventional aqueous electrolytes (1.23 V). Here, in this study, we present a transformative approach using an inexpensive and rapidly dissolvable inorganic glass material, water glass (W-glass), to significantly enhance the ESW and enable the development of solid-state, self-supporting aqueous film (SSA film) electrolytes. These SSA film electrolytes exhibit an extended ESW of up to 3.5 V and a conductivity of ∼10 –4 S/cm at room temperature. Structural analysis using magic-angle spinning nuclear magnetic resonance (NMR) and solution-state NMR reveals that the dissolution of W-glass in water is driven by the interdependent hydrolysis of P–O–P linkages and Na + –H + ion exchange. This work offers a cost-effective and scalable solution for advancing high-performance ARNIB technology, addressing critical barriers to commercial adoption.

Electrochemical stability window

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Heat transfer coefficients of moving particle beds from flow-dependent thermal conductivity and near-wall resistance

Accurate determination of heat transfer coefficients for flowing packed particle beds is essential to the design of particle heat exchangers and other thermal and thermochemical equipment. While such dense granular flows mostly fall into the well-known plug-flow regime, the discrete nature of granular materials alters the thermal transport processes in both the near-wall and bulk regions of flowing particle beds from their stationary counterparts. As a result, heat transfer correlations based on the stationary particle bed thermal conductivity could be inadequate for flowing particles in a heat exchanger. Most earlier works have achieved a reasonable agreement with experiments by treating granular heat transfer media as a plug-flow continuum with a near-wall thermal resistance in series. However, the thermal conductivity values of the continuum were often obtained from measurements on stationary beds owing to the difficulty of flowing bed measurements. In this work, it was found that the properties of a stationary bed are highly sensitive to the method of particle packing and there is a decrease in the particle bed thermal conductivity and increase in the near-wall thermal resistance, measured as an effective air gap thickness, on the onset of particle flow. These variations in thermal conductivity of stationary and flowing particle beds can lead to errors in heat transfer coefficient calculations. Therefore, the heat transfer coefficients for granular flows were calculated using experimentally determined flowing particle bed thermal conductivity and near-wall air gap for ceramic particles – CARBO CP 40/100 (mean diameter = 275 µm), HSP 40/70 (404 µm) and HSP 16/30 (956 µm); at velocities of 5–15 mm·s –1 ; and temperatures of 300–650 °C. The thermal conductivity and air gap values for CP 40/100 and HSP 40/70 were further used to calculate heat transfer coefficients across different particle bed temperatures and velocities for different parallel-plate heat exchanger dimensions. Furthermore, these calculations, which show good agreement with measured HTC values reported in literature, can be used as a guide for heat exchanger designs. Graphical abstract

14 SOLAR ENERGY

Interfacial Reactivity-Triggered Oscillatory Lattice Strains of Nanoalloys

Understanding the structure evolution of nanoalloys under reaction conditions is vital to the design of active and durable catalysts. Herein, we report an operando measurement of the dynamic lattice strains of dual-noble-metal alloyed with an earth-abundant metal as a model electrocatalyst in a working proton-exchange membrane fuel cell using synchrotron high-energy X-ray diffraction coupled with pair distribution function analysis. Additionally, the results reveal an interfacial reaction-triggered oscillatory lattice strain in the alloy nanoparticles upon surface dealloying. Analysis of the lattice strains with an apparent oscillatory irregularity in terms of frequency and amplitude using time-frequency domain transformation and theoretical calculation reveals its origin from a metal atom vacancy diffusion pathway to facilitate realloying upon dealloying. This process, coupled with surface metal partial oxidation, constitutes a key factor for the nanoalloy's durability under the electrocatalytic oxygen reduction reaction condition, which serves as a new guiding principle for engineering durable or self-healable electrocatalysts for sustainable fuel cell energy conversion.

Wu, Zhi-Peng [State University of New York (SUNY),

Fingerprinting fractons with pump-probe spectroscopy

We demonstrate how pump-probe techniques enable specific spectroscopic diagnostics of fracton phases of matter by studying lineon-planon braiding in the paradigmatic X-cube model. Our discussion builds on previous works probing anyonic exchange statistics in conventional spin liquids, but the extension to fracton phases reveals qualitatively different phenomena due to the restricted mobility of fractionalized excitations. A key feature is that nearby planons can form an emergent bound state by accessing different planes via alternative pairing configurations. We show that this bound state qualitatively modifies the long-time linear and nonlinear responses, leading to an asymptotic linear-in-𝑡 behavior for the pump-probe signal 𝜒 𝑍𝑍𝑋 . By contrast, swapping the pump and probe polarizations produces a nonlinear response 𝜒 𝑋𝑋𝑍 that is asymptotically 𝑡 independent. This asymmetry reflects the fact that the two species of fractionalized excitations live in different spatial dimensions. Thus the pump-probe signals studied here are sensitive to (i) nontrivial braiding statistics in three dimensions, (ii) the existence of bound states among fractionalized excitations, and (iii) the one-dimensional mobility of lineons. Furthermore, our results therefore provide spectroscopic signatures that distinguish fracton phases from conventional topologically ordered spin liquids.

braiding

Quantum Thermodynamics of Nonequilibrium Processes in Lattice Gauge Theories

A key objective in nuclear and high-energy physics is to describe nonequilibrium dynamics of matter, e.g., in the early Universe and in particle colliders, starting from the standard model of particle physics. Classical computing methods, via the framework of lattice gauge theory, have experienced limited success in this mission. Quantum simulation of lattice gauge theories holds promise for overcoming computational limitations. Because of local constraints (Gauss’s laws), lattice gauge theories have an intricate Hilbert-space structure. This structure complicates the definition of thermodynamic properties of systems coupled to reservoirs during equilibrium and nonequilibrium processes. We show how to define thermodynamic quantities such as work and heat using strong-coupling thermodynamics, a framework that has recently burgeoned within the field of quantum thermodynamics. Our definitions suit instantaneous quenches, simple nonequilibrium processes undertaken in quantum simulators. To illustrate our framework, we compute the work and heat exchanged during a quench in a Z 2 lattice gauge theory coupled to matter in 1+1 dimensions. Here, the thermodynamic quantities, as functions of the quench parameter, evidence a phase transition. For general thermal states, we derive a simple relation between a quantum many-body system’s entanglement Hamiltonian, measurable with quantum-information-processing tools, and the Hamiltonian of mean force, used to define strong-coupling thermodynamic quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Ammonium-coordinated exchanger (ACE) functionalized silica sorbents for recovering/removing aqueous anionic contaminants

There are limited studies of functionalized silica anion exchange sorbents used for critical/heavy metal recovery/removal relative to polymeric and other inorganic materials. This work features ammonium-coordinated exchanger (ACE) anion exchange particle sorbents prepared by either acid-washing epoxy-crosslinked polyethylenimine (PEI) hydrogen bonded within/to a silica particle sorbent (two-step method) or reacting a di-chlorinated crosslinker, α,α-dichloro-p-xylene (DPX), with PEI within silica (single-step method). Energy dispersive X-ray spectroscopy (EDS) and infrared spectroscopy confirmed the presence of -NH 2 + ···Cl - and -NH 3 + ···Cl - groups, which removed oxyanionic species –arsenate, selenate, chromate, sulfate, phosphate, and nitrate– plus bromide from ideal solutions, authentic acid mine drainage (AMD), and authentic flue gas desulfurization (FGD) wastewater. Affinity of the anions for ACE varied across single- and mixed-element solutions. However, affinity for CrO 4 2- was among the highest in both cases. Total anion uptake by the optimized ACE, PEI-E3-HCl_1.1, reached 1.2 mmol anion/g-sorb. (0.56 mmol CrO 4 2- /g), or ∼2.3 mmol negative charge/g-sorb. This was close to the 0.52 mmol CrO 4 2- /g of a commercial anion exchange resin. Near-consistent removal of 20–80 % of each anion from FGD during an eight-cycle adsorption-desorption (1 M NaCl) test predicted good ACE viability for testing under practical conditions at larger scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Atmospheric Variability Drives Anomalies in the Bering Sea Air–Sea Heat Exchange

Abstract High latitudes, including the Bering Sea, are experiencing unprecedented rates of change. Long-term Bering Sea warming trends have been identified, and marine heatwaves (MHWs), event-scale elevated sea surface temperature (SST) extremes, have also increased in frequency and longevity in recent years. Recent work has shown that variability in air–sea coupling plays a dominant role in driving Bering Sea upper-ocean thermal variability and that surface forcing has driven an increase in the occurrence of positive ocean temperature anomalies since 2010. In this work, we characterize the drivers of the anomalous surface air–sea heat fluxes in the Bering Sea over the period 2010–22 using ERA5 fields. We show that the surface turbulent heat flux dominates the net surface heat flux variability from September to April and is primarily a result of near-surface air temperature and specific humidity anomalies. The airmass anomalies that account for the majority of the turbulent heat flux variability are a function of wind direction, with southerly (northerly) wind advecting anomalously warm (cool), moist (dry) air over the Bering Sea, resulting in positive (negative) surface turbulent flux anomalies. During the remaining months of the year, anomalies in the surface radiative fluxes account for the majority of the net surface heat flux variability and are a result of anomalous cloud coverage, anomalous lower-tropospheric virtual temperature, and sea ice coverage variability. Our results indicate that atmospheric variability drives much of the Bering Sea upper-ocean temperature variability through the mediation of the surface heat fluxes during the analysis period. Significance Statement A long-term ocean warming trend and a recent increase in marine heatwaves in the Bering Sea have been identified. Previous work showed that anomalies in the exchange of heat between the ocean and the atmosphere were the primary driver of Bering Sea temperature variability, but the processes responsible for the heat exchange anomalies were unknown. In this work, we show that the atmosphere is the primary driver of anomalies in the Bering Sea air–sea heat exchange and therefore plays an important role in altering the thermal state of the Bering Sea. Our results highlight the importance of understanding more about how the ocean and the atmosphere interact at high latitudes and how this relationship will be affected by future climate change.

Hayden, Emily E. [a College of Earth, Ocean, and A

iFair: Achieving Fairness in the Allocation of Scarce Resources for Senior Health Care

Efficient resource allocation is crucial in many domains, particularly in senior care, where assigning resources to older adults must consider uncertainties associated with vulnerable populations. In collaboration with Senior Health Facilities (SHFs) and domain experts, this paper presents iFair, a novel framework designed to assist decision-makers in equitably allocating scarce resources to older adults. iFair was prototyped in the context of ongoing work on a data exchange platform, CAREDEX, used for enhancing older adults' resilience during disasters. A key novelty of iFair focuses on aligning resident preferences with resources in urgent situations, expediting care, and enhancing task efficiency. We integrate static and dynamic environmental data, including facility layouts and sensor data, with detailed resident profiles to cater to the individual needs and preferences of residents. While our framework primarily focuses on allocation within facilities, it also extends to a regional scale to support the planning and transfer of seniors to mutual aid facilities. Our experiments adapt data from a real SHF to emulate resource allocation in an emergency fire evacuation setting and highlight the delicate balance that decision-makers can achieve between efficiency and fairness.

Kenne, Modeste Mefenya

Fully thermal meta-GGA exchange correlation free-energy density functional

The application of density functional theory to materials in the warm dense matter regime has motivated the development of exchange-correlation functionals which incorporate proper, explicit temperature dependence. Previous work has yielded fully-thermal exchange-correlation free energy functionals at the local density approximation (LDA) and generalized gradient approximation (GGA) levels of refinement. Recently an additive thermal correction scheme was utilized to construct a meta-GGA exchange-correlation (XC) functional in which thermal effects are treated at the GGA level. Here, the f TSCAN free-energy XC functional presented here includes thermal effects through the meta-GGA level in the context of the SCAN (strongly constrained and appropriately normed) ground-state functional. The f TSCAN functional provides generality while achieving similar performance to a thermal GGA functional at high temperatures, e.g. pressures within 1% of path integral Monte Carlo simulations of warm dense hydrogen, and a significant improvement over ground-state functionals. At low temperatures, f TSCAN demonstrates improvements in accuracy relative to lower-level and deorbitalized functionals, indicating that calculations using f TSCAN may be expected to perform well across experimentally relevant densities and pressures.

36 MATERIALS SCIENCE

Intrinsic exchange bias from interfacial reconstruction in an epitaxial Ni x Co y Fe 3– x – y O 4 (111)/α-Al 2 O 3 (0001) thin film family

Intrinsic exchange bias is known as the unidirectional exchange anisotropy that emerges in a nominally single-component ferro-(ferri-)magnetic system. In this work, with magnetic and structural characterizations, we demonstrate that intrinsic exchange bias is a general phenomenon in (Ni, Co, Fe)-based spinel oxide films deposited on α-Al 2 O 3 (0001) substrates, due to the emergence of a rock-salt interfacial layer consisting of antiferromagnetic CoO from interfacial reconstruction. We show that in Ni x Co y Fe 3–x–y O 4 (111)/α-Al 2 O 3 (0001) films, intrinsic exchange bias and interfacial reconstruction have consistent dependences on Co concentration y, while the Ni and Fe concentration appears to be less important. This work establishes a family of intrinsic exchange bias materials with great tunability by stoichiometry and highlights the strategy of interface engineering in controlling material functionalities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

High-energy $η^{(')}π$ photoproduction and the nature of exotic waves

The observation of hybrid mesons in photoproduction experiments can provide essential insight into the inner workings of quantum chromodynamics in the strong coupling regime. In particular, the study of final $η^{(')}π$ states is of great interest due to the presence of the lowest lying hybrid candidate with manifestly exotic quantum numbers, the $π_1$(1600). In this work, a double-vector exchange model with Reggeized $ρ$ and $ω$ trajectories is developed to describe the photoproduction of $η^{(')}π$ in the high-mass region. Results are presented for the differential cross sections and forward-backward asymmetries in the energy region of interest to the GlueX experiment. The model contains no free parameters, and reproduces the magnitude and t-dependence of existing CLAS data at $E_γ$ = 5 GeV. The model predicts a stronger asymmetry in the $η'π$ channel than in the $ηπ$ channel, consistent with what has previously been observed in pion beam experiments. This suggests that the sizeable production of exotic odd waves in $η'π$ is not necessarily related to the presence of gluon-rich environments. Confirmation of these predicted asymmetries from forthcoming GlueX data would enable further predictions of the low-energy spectrum.

Montaña, Glòria [Thomas Jefferson National Acceler