Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Westerly Granite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The effect of dilatancy on velocity anisotropy in Westerly granite

Jacketed samples of Westerly granite were fractured at confining pressures up to 1 kbar, and compressional and horizontally as well as vertically polarized shear velocities were measured in orthogonal directions perpendicular to the compression axis. Changes occurring with increased strain are described, and the velocity data were analyzed by application of the Anderson et al (1974) approach. Observed and calculated velocities are found to be in good agreement, and the degree of dilatancy was determined from the differences between the strains measured perpendicularly to the compression axis and the estimated elastic strains in those directions.

Soga, N.↗

Strain localization during deformation of Westerly granite

A specimen of Westerly granite was cyclically loaded to near failure at 50 MPa confining pressure. Holographic interferometry provided detailed measurements of localized surface deformations during loading and unloading. The data are consistent with deformation occurring primarily elastically at low differential stress; in conjunction with one incipient fault zone between approximately 350 and 520 MPa differential stress; and in conjunction with a second incipient fault zone above 580 MPa and/or during creep. During unloading only one fault zone, that which is active at the intermediate stress levels during loading, is seen to recede.

Brodsky, N. S.↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Intrinsic Elastic Anisotropy of Westerly Granite Observed by Ultrasound Measurements, Microstructural Investigations, and Neutron Diffraction

Westerly granite (WG) has been generally accepted as an isotropic homogeneous rock. Here, we return to WG and observe significant elastic anisotropy using multidirectional ultrasonic sounding on spherical samples at pressures up to 400 MPa. Thermal treatment of WG leads to formation of microcracks that reduce elastic wave velocities and increase its elastic anisotropy. The 3D distribution of P-wave velocities at low pressure is close to orthorhombic symmetry. Application of hydrostatic pressure closes most of thermally induced microcracks and decreases elastic anisotropy of WG, but at high pressure the anisotropy is practically reversed compared to low pressure: maximum P-wave velocity direction at low pressures is near minimum velocity direction at high pressure and vice versa. To understand this effect, microstructures of the rock were investigated by optical and scanning electron microscopy. Preferred orientations of four major rock-forming minerals—quartz, orthoclase, plagioclase, and biotite—were measured by time-of-flight neutron diffraction, which confirms significant crystal alignment. All these data were used to numerically model anisotropic elastic properties of WG. It is shown that WG possesses weak intrinsic elastic anisotropy related mainly to the preferred orientation of feldspars formed during igneous crystallization. Observed microcracks are mostly related to the cleavage planes of feldspars and biotite, and thus also demonstrate preferred orientation. Higher preheating temperatures produce larger quantity of longer microcracks. A numerical model shows that these microcracks act against the weak intrinsic elastic anisotropy of WG, and define the elastic anisotropy at low pressures.

58 GEOSCIENCES↗

DCIF Westerly Granite AE Stress Effect Test (Task 3-1)

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on rectangular Westerly granite blocks (width=depth=4.0", height=2.0"). Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. Several confining stresses were applied bi-axially to the sides of the samples so that the onset of AE activity and the stress applied to the sample were correlated. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission are the animations of the AE locations and graphics displaying the measured temperature-AE activity changes for different stresses.

15 GEOTHERMAL ENERGY↗

Directional Cooling-Induced Fracturing Westerly Granite Test Results

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission is an animation of the AEs, a graphic displaying the temperature changes, and the measured data.

15 GEOTHERMAL ENERGY↗

DCIF (Directional Cooling-Induced Fracturing) Westerly Granite AE Borehole Damage Effect Test (Task 3-0)

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The experiments were conducted under one selected biaxial stress (5.8MPa). The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. The onset time of the AEs was correlated with the cooling temperature, which was used to show that the temperature at the onset of microcracking is not affected significantly by the preexisting damage, compared to the impact of the stress in the sample. Included in this submission are the animations of the AE locations and graphics displaying the measured temperature-AE activity changes for samples with different degrees of microcrack damage.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Slide-Hold-Slide Experiments on Westerly Granite at Temperatures up to 250 Degrees C

Laboratory slide-hold-slide tests were conducted in a conventional triaxial deformation configuration on 1-inch diameter cylindrical cores of Westerly granite bisected by a sawcut oriented at 30 degrees from vertical. Tests were conducted at a constant confining pressure of 30 MPa with a 10 MPa pore fluid pressure. The pore fluid was deionized water. Experiments were conducted at temperatures of 22, 100, 200, and 250 C. This data was collected to examine fault strength recovery in hydrothermal conditions.

15 GEOTHERMAL ENERGY↗

The effects of pressure, temperature, and pore water on velocities in Westerly granite

A description is presented of an experimental assembly which has been developed to conduct concurrent measurements of compressional and shear wave velocities in rocks at high temperatures and confining pressures and with independent control of the pore pressure. The apparatus was used in studies of the joint effects of temperature, external confining pressure, and internal pore water on sonic velocities in Westerly granite. It was found that at a given temperature, confining pressure has a larger accelerating effect on compressional waves in dry rock, whereas at a given confining pressure, temperature has a larger retarding effect on shear waves.

Spencer, J. W., Jr.↗

Directional Cooling-Induced Fracturing: Directional Cooling Data Under True-Triaxial Stress State

Data includes Directional Cooling-Induced Fracturing (DCIF) testing data using westerly granite blocks. This submission includes data from two samples of westerly granite, lab sample 7 and 8. Files contain stress, temperature and acoustic emission data acquired during polyaxial, laboratory testing of westerly granite blocks for each sample. FILES: .tradb -- files containing acoustic emission waveforms; sqlite3 database .pridb -- files containing basic acoustic emission information (no waveforms); sqlite3 database .geom -- geometry of the AE sensor network (ASCII)

15 GEOTHERMAL ENERGY↗

Ultrasonic probing of the fracture process zone in rock using surface waves

A microcrack process zone is frequently suggested to accompany macrofractures in rock and play an important role in the resistance to fracture propagation. Attenuation of surface waves propagating through mode I fractures in wedge-loaded double-cantilever beam specimens of Westerly granite has been recorded in an attempt to characterize the structure of the fracture process zone. The ultrasonic measurements do not support the generally accepted model of a macroscopic fracture that incrementally propagates with the accompaniment of a cloud of microcracks. Instead, fractures in Westerly granite appear to form as gradually separating surfaces within a zone having a width of a few millimeters and a length of several tens of millimeters. A fracture process zone of this size would necessitate the use of meter-sized specimens in order for linear elastic fracture mechanics to be applicable.

Swanson, P. L.↗

Experimental Investigation of Elastodynamic Nonlinear Response of Dry Intact, Fractured and Saturated Rock

Nonlinear elastodynamic response of fractured rocks carries crucial information on fracture features that can be exploited to forecast flow properties, friction constitutive behavior and poromechanical response. Well-controlled laboratory experiments are designed to measure the nonlinear elastodynamic response of Westerly granite in three states: dry intact, dry fractured and saturated fractured. We study the effect of fracturing and saturation in modifying the elastodynamic response of the rock. Each sample is tested at a normal stress level of 15 MPa. We measure the elastodynamic response of an intact L-shaped sample of Westerly Granite subjected to normal stress oscillations of prescribed amplitudes (0.2–1 MPa) and frequencies (0.1, 1, 10 Hz). Ultrasonic waves transmitted across the sample are used to monitor the evolution of wave velocity before, during and after dynamic stressing. Furthermore, the nonlinearity of the elastodynamic response is measured in terms of: (1) the offset in normalized wave velocity; (2) the amplitude of wave velocity fluctuation during the oscillations; and (3) recovery rate of the wave velocity post-oscillation. We observe that the three nonlinearity parameters show a similar trend. Irrespective of the parameter, the nonlinearity measures higher for sample in dry-intact condition than that for dry-fractured and the saturated-fractured sample exhibits smaller nonlinearity than the dry-fractured sample. As expected, the saturated sample exhibits less nonlinearity than the dry intact and fractured samples due to the presence of interstitial fluid and the resulting increased interface stiffness. Conversely, the dry intact rock shows a higher nonlinearity than the dry fractured. We use numerical simulations to show that the presence of fracture significantly alters the strain distribution across the bulk of the sample and only the contacting asperities are highly strained, thus resulting in a decrease in the measured elastodynamic nonlinearity.

58 GEOSCIENCES↗

Utah FORGE Hydrothermal Friction-Hydraulic Transmissivity Laboratory Experiments

Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 and 200 degC. Three fluid flow conditions were examined (1) no flow, (2) cycled flow, and (3) continuous flow. Data were collected to asses the effect of temperature and pore fluid on frictional healing rates in granite at geothermal conditions. Data is available in XML and JSON data types.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Time‐Dependent Weakening of Granite at Hydrothermal Conditions

Abstract The evolution of a fault's frictional strength during the interseismic period is a critical component of the earthquake cycle, yet there have been relatively few studies that examine the time‐dependent evolution of strength at conditions representative of seismogenic depths. Using a simulated fault in Westerly granite, we examined how frictional strength evolves under hydrothermal conditions up to 250°C during slide‐hold‐slide experiments. At temperatures ≤100°C, frictional strength generally increases with hold duration but, at 200 and 250°C, an initial increase in strength transitions to rapid time‐dependent weakening for holds longer than 14 hr. Forward modeling of long hold periods at 250°C using the rate and state friction constitutive equations requires a second, strongly negative, state variable with a long evolution distance. This implies that significant hydrothermal alteration is occurring at 250°C, consistent with microstructural observations of dissolution and secondary mineral precipitation.

Geology↗