Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wave Relay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Radiation Detection System Integration Using Multiple-Input Multiple-Output Radios

This study describes the application development of multiple-input multiple-output radios to provide persistent mobile ad hoc network (MANET) for the Department of Homeland Security. By using Man Portable Unit (MPU5) fifth generation radios (manufactured by Persistent Systems) with the Android Team Awareness Kit (ATAK), an Android smartphone geospatial infrastructure and military situational awareness application, the Remote Sensing Laboratory has developed a MANET connectivity to monitor deployed nuclear/radiological search operation assets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-enabled traveling wave protection for microgrids

Grid forming inverters provide voltage and frequency regulations for microgrids; in the meantime, new challenges are introduced for microgrid protections. For instance, inverters’ control strategies can affect protection behaviors, and low short-circuit ratios and bi-directional power flows also make protection operations complex. Protection schemes based on conventional principles such as overcurrent and distance relays do not always provide reliable, sensitive, or selective operations. Here, we devise a traveling wave protection approach for microgrids using a wavelet-driven deep neural network named WaveletKernelNet (WKN). Compared with conventional methods, the presented approach provides enhanced sensitivity, higher selectivity, and better identification of various faults in microgrids. Extensive case studies validate the efficacy and excellent performance of the devised approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IoT-Enabled Traveling Wave Microgrid Protection

Traveling Wave Protection based on the Internet of Things (TWP-IoT) is developed to enable ultra-resilient microgrids. TWP-IoT adopts a directional traveling wave approach that utilizes the voltage and current modal components obtained from Discrete Hilbert Transform to identify the fault features via ultra-lightweight IoT hardware. Furthermore, the main contributions of this work include (1) a novel TWP-IoT for microgrid and distribution networks that can achieve the time-of-arrival fault detection and localization with composite wave impedance and conductance using Discrete Hilbert Transform, (2) a cost-effective smart IoT prototype with functionalities outperforming commercial relays, and (3) a real-time hardware-in-the-loop prototype based on RTDS that verifies the robustness and efficacy of TWP-IoT subject to a diverse set of working conditions. TWP-IoT is found to have excellent performance under a wide spectrum of internal and external fault conditions across a myriad of microgrid locations, which is unattainable by today’s TWP products.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗