Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WISG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Grobner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Grobner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

47 OTHER INSTRUMENTATION↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Gröbner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Gröbner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers: Preprint

The World Radiation Center at PMOD/WRC is operated on behalf of the WMO. The Infrared Radiometry Section of the WRC (WRC-IRS) provides traceability of downwelling atmospheric longwave radiation measured with pyrgeometers by comparison to the World Infrared Standard Group (WISG) [1]. As has been discussed previously [2], the current implementation of the WISG measures lower longwave irradiances than the two candidate reference radiometers IRIS (Infrared Integrating Sphere Radiometer) and the ACP (Absolute Cavity Pyrgeometer). To validate the findings reported in [2], additional measurements since that publication in 2014 have been performed and are discussed in this paper. Specifically, Measurements during cloud-free nights at PMOD/WRC between the WISG and IRIS radiometers, A field campaign at the Atmospheric Radiation Monitoring Site (ARM) at Southern Great Plains, Oklahoma with IRIS, ACP, AERI (Atmospheric Emittance Radiance Interferometer) and WISG traceable pyrgeometers, Laboratory comparison between the reference blackbody of PMOD/WRC with the hemispherical blackbody developed by PTB.

ACR↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 26-October 7, 2022

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 26 to October 7, 2022. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS varied from -0.80 W/m2 to 0.29 W/m2 and standard deviation (sd) from 0.98 W/m2 to 1.78 W/m2. The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 2.07 to 5.03 W/m2 with sd from 2.64 W/m2 to 2.67 W/m2.

14 SOLAR ENERGY↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 23-October 4, 2024

The comparison of the absolute cavity pyrgeometers (ACPs) with the CG4 FT005 pyrgeometer traceable to the InfraRed Integrating Sphere (IRIS) referred to by FT005(IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 23 to October 4, 2024. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. Two methods described in and were used for the comparison based on original Reda et. al and proposed Forgan et. al.

47 OTHER INSTRUMENTATION↗

Absolute Cavity Pyrgeometer (ACP)

ACP Measures atmospheric longwave irradiance with traceability to the International System of Units (SI). To date the Interim world reference World Infrared Standard Group (WISG) is traceable to blackbody (not sky/atmosphere), and InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. The ACP is self calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers

The traceability of the World Infrared Standard Group of Pyrgeometers (WISG) was established through the comparison to several independently calibrated radiometers (Infrared Integrating Sphere Radiometer (IRIS), Absolute Cavity Pyrgeometer (ACP), Atmospheric Emittance Radiance Interferometer (AERI)). The traceability of the longwave irradiance measurements to SI was validated by a comparison of two independently characterized blackbody cavities.

ACR↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗

Latest Development to Establish the World Reference with Traceability to SI Units for Measuring the Atmospheric Shortwave and Longwave Irradiance

To date, Interim world reference traceable to blackbody (not sky/atmosphere) is used as a reference noted as a World Infrared Standard Group (WISG). Plan forward: to develop a reference standards traceable to SI InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. Absolute Cavity Pyrgeometer (ACP) developed by NLR is a self-calibrating radiometer using heat substitution to measure the atmospheric longwave irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

14 SOLAR ENERGY↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Absolute Cavity Pyrgeometer (ACP)

Measure atmospheric longwave irradiance. ABSOLUTE measurement traceable to International System of Units (SI). To date, Interim world reference traceable to blackbody (not sky/atmosphere), World Infrared Standard Group (WISG). InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. ACP is self-calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self-calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗