Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume of Fluid (VOF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A SUB-GRID VOLUME-OF-FLUIDS (VOF) MODEL FOR MIXING IN RESOLVED SCALE AND IN UNRESOLVED SCALE COMPUTATIONS

A sub-grid mix model based on a volume-of-fluids (VOF) representation is described for computational simulations of the transient mixing between reactive fluids, in which the atomically mixed components enter into the reactivity. The multi-fluid model allows each fluid species to have independent values for density, energy, pressure and temperature, as well as independent velocities and volume fractions. Fluid volume fractions are further divided into mix components to represent their 'mixedness' for more accurate prediction of reactivity. Time dependent conversion from unmixed volume fractions (denoted cf) to atomically mixed (af) fluids by diffusive processes is represented in resolved scale simulations with the volume fractions (cf, af mix). In unresolved scale simulations, the transition to atomically mixed materials begins with a conversion from unmixed material to a sub-grid volume fraction (pf). This fraction represents the unresolved small scales in the fluids, heterogeneously mixed by turbulent or multi-phase mixing processes, and this fraction then proceeds in a second step to the atomically mixed fraction by diffusion (cf, pf, af mix). Species velocities are evaluated with a species drift flux, {rho}{sub i}u{sub di} = {rho}{sub i}(u{sub i}-u), used to describe the fluid mixing sources in several closure options. A simple example of mixing fluids during 'interfacial deceleration mixing with a small amount of diffusion illustrates the generation of atomically mixed fluids in two cases, for resolved scale simulations and for unresolved scale simulations. Application to reactive mixing, including Inertial Confinement Fusion (ICF), is planned for future work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid multiphase CFD simulation for liquid-liquid interfacial area prediction in annular centrifugal contactors

Liquid-liquid contacting equipment used in solvent extraction processes has the dual purpose of mixing and separating two immiscible fluids. Consequently, such devices inherently encompass a wide variety of multiphase flow regimes. A hybrid multiphase computational fluid dynamics (CFD) solver which combines the Eulerian multi-fluid method with VOF (volume of fluid) sharp interface capturing has been developed for application to annular centrifugal contactors. This solver has been extended to enable prediction of mean droplet size and liquid-liquid interfacial area through a single moment population balance method. Simulations of liquid-liquid mixing in a simplified geometry and a model annular centrifugal contactor are reported with droplet breakup/coalescence models being calibrated versus available experimental data. Quantitative comparison is made for two different housing vane geometries and it is found that the predicted droplet size is significantly smaller for vane geometries which result in higher annular liquid holdup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiphase flow studies for microscale hydrodynamics in the structured packed column

Post combustion carbon capture by solvent absorption in a structured packed column is a promising technology for mitigating greenhouse gas emissions. Computational fluid dynamic (CFD) modelling of such a column is a challenging multiscale problem due to the range in length and time scales. The microscale hydrodynamics play a key role in the overall column efficiency with the interfacial area significantly influencing the mass transfer between the gas and liquid phases. In this context, multiphase flow simulations using the volume of fluid (VOF) method in a representative elementary unit (REU) of the packed column can provide fundamental insights into the microscale hydrodynamics, such as, interfacial area and liquid holdup. The present paper systematically examines the impact of various factors (e.g., physical properties and contact angle) on the interfacial area. The results are compared with existing correlations and a scaling analysis is also performed. The solvent physical properties are characterized by the Kapitza number (Ka), a dimensionless number that depends only on fluid properties. So that the Ka number decreases with increasing viscosity. At a fixed liquid load, the interfacial area and liquid holdup are observed to increase with decreasing Ka number. The impact of contact angle (i.e., solid surface characteristics) is effectively investigated by modifying the wall boundary conditions. The interfacial area and liquid holdup are found to decrease with increasing contact angle. Subsequently, a phenomenological correlation for interfacial area is proposed that includes the impact of these parameters. Finally, this correlation may be used to predict the interfacial area for gas-liquid flow in a structured packing for rivulet to fully wetted flow regimes.

42 ENGINEERING↗

A comparative study of interface reconstruction methods for multi-material ALE simulations

In this paper we compare the performance of different methods for reconstructing interfaces in multi-material compressible flow simulations. The methods compared are a material-order-dependent Volume-of-Fluid (VOF) method, a material-order-independent VOF method based on power diagram partitioning of cells and the Moment-of-Fluid method (MOF). We demonstrate that the MOF method provides the most accurate tracking of interfaces, followed by the VOF method with the right material ordering. The material-order-independent VOF method performs somewhat worse than the above two while the solutions with VOF using the wrong material order are considerably worse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation of Air Discharge into a Water Pool by Using Volume-of-Fluid Method

Suppression tanks, in-containment refueling water storage tanks (IRWSTs) and filtered containment venting systems (FCVSs) of nuclear power plants use water pools to accommodate high-pressure and high-temperature discharge of non-condensable gases and/or steam. Dynamic behavior of gas bubbles inside a water pool determines pressure and temperature loading to the system and thus we need validated method for applications. The underlying physics relevant to these problems is still a difficult issue due to the complicated nature of gas- liquid interfacial transfers of mass, momentum, and energy in a two-phase flow. Therefore, notwithstanding many studies performed over the past two or three decades, two-fluid theory is still a formidable task and direct numerical simulation (DNS) needs huge computing cost. Pellegrini et al. analyzed steam condensation and chugging in the water pool of the PPOOLEX STB-24 test by using STAR-CCM+ code implemented with two-phase interface model based on the Rayleigh-Taylor instability theory (RTI) which triggers steam depressurization. For the solution of the fine interface, they used Eulerian-Eulerian model for the fluid domain since the volume-of-fluid (VOF) model requires larger mesh points. The RTI resulted in complete steam condensation consistent with the experiment. The fluid tank was open to the atmosphere. They reported the volume fraction distributions in the pool, not the pool temperature or pressure history. For non-condensing gas discharges, however, the VOF is still a good alternative to the Eulerian two-fluid or the DNS approaches. The spatial distribution of each phase is defined in terms of volume fractions and the cell physical properties are obtained from linear combinations of those of constituent phases weighted by each volume fraction. Therefore, conditions where thermal and phase change effects become important are less likely to be simulated realistically. The VOF model is suited for the simulation of flows where each phase constitutes a large structure with a relatively small total contact area between phases. Present work is also interested in this VOF method for application to air discharge into a water pool which occurs in the early operating stages of the said facilities. Our purpose is to validate the VOF method against an existing air discharge experiment of PPOOLEX by using a commercial CFD code, STAR-CCM+ version 10.04, in terms of macroscopic flow properties. Effect of turbulence is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capturing thin structures in VOF simulations with two-plane reconstruction

A novel interface reconstruction strategy for volume of fluid (VOF) methods is introduced that represents the liquid-gas interface as two planes that co-exist within a single computational cell. In comparison to the piecewise linear interface calculation (PLIC), this new algorithm greatly improves the accuracy of the reconstruction, in particular when dealing with thin structures such as films. The placement of the two planes requires the solution of a non-linear optimization problem in six dimensions, which has the potential to be overly expensive. Further, an efficient solution to this optimization problem is presented here that exploits two key ideas: an algorithm for extracting multiple plane orientations from transported surface data, and an efficient and mass-conserving distance-finding algorithm that accounts for two planes with arbitrary orientation. Additionally, a simple and robust strategy is presented to accurately represent the surface tension forces produced at the interface of subgrid-thickness films. The performance of this new VOF reconstruction is demonstrated on several test cases that illustrate the capability to handle arbitrarily thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Geometric Volume of Fluid-Based Multiphase Flow Solver Extension to the Reacting Flow Solver, PeleLM

A new algorithm is presented to simulate multiphase flows with surface tension in a pathway for spray combustion simulation. The algorithm combines capabilities from two open-source packages, including the interface reconstruction library (IRL), a library of computational geometry routines to enable the volume of fluid (VOF) method, and PeleLM, a solver for the reacting Navier-Stokes equations. Additionally, surface tension is implemented using the continuum surface force (CSF) model with an improved height function technique in the volume fraction field. Spurious errors in volume fraction arising from our combined strategy are corrected through a topology-based method that improves both numerical stability and accuracy. Multiple validation simulations are conducted, including (i) translations and rotations of Zalesak's disk, (ii) a stationary circular droplet with surface tension, (iii) an oscillating elliptical droplet, and (iv) three-dimensional deformation of a spherical droplet. Results indicate that the combined scheme retains the favorable properties of each of the component algorithms.

42 ENGINEERING↗

Towards Resolving the Atomization Process of an Idealized Fire Sprinkler with VOF Modeling

Fire suppression modeling depends on accurate characterization of the atomization processes of fire sprinklers.Numerical modeling, particularly the volume of fluid (VOF) method, has been applied to understanding the atomization behavior of an idealized sprinkler geometry consisting of a 9.5 mm inner-diameter cylindrical nozzle and a flat, 25.4 mm diameter disk with a liquid flow rate of 0.87 L/s. The simulations have been performed with an OpenFOAM based VOF solver, using the isoAdvector scheme for interfacial reconstruction. The sheet breakup distance and film thickness were calculated and compared with measurements from a previous study. A mesh refinement study identified the sensitivities in the predicted quantities to mesh resolution. This study enables furtherapplication of the model to simulation of the fully atomized spray.

Engineering↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

Non-Diffusive Volume Advection with A High Order Interface Reconstruction Method

We show that non-diffusive volume advection in two-dimensions is achieved with several benchmark problems using a newly developed high-order volume of fluids (VOF) interface reconstruction method. (1) A new VOF interface reconstruction method using circular/corner facets (linear facets are a degenerate case of arcs). We create a circular interface facet in each mixed zone by matching neighbor volume with a hybrid Newton’s-bisection method and the local solution is final. In the general case, the new VOF interface reconstruction has 3rd order accuracy and can be easily made seamless. The new method addresses intrinsic issues with Young’s method such as gaps between interface facets in the case of a curved interface, and inability to define curvature nor identify corners. (2) A non-diffusive volume advection scheme. In an ALE advection step, a well-defined interface can be carried over through a Lagrange step and used to compute volume distribution into a relaxed mesh. Then, an interface reconstruction step is performed to redefine the interface in the relaxed mesh. We must point out that the interface carried over is also a solution of interface reconstruction because all the volume fractions in the relaxed mesh are naturally matched. We provide an interface tracking method compatible with our reconstruction scheme, where it is granted to use the prior info as an initial guess to capture sub-mesh resolution features. As a result, we are able to treat multiple facets inside a single mixed cell and obtain highly accurate, non-diffusive solution for advection problems with rather coarse meshes. We show our solutions for two-dimensional incompressible flows with two materials with a) the X + O diagonal translation; b) the Zalesak rotational test; and c) the single vortex spiral test.

97 MATHEMATICS AND COMPUTING↗

Evaporation Submodel Development for Volume of Fluid (eVOF) Method Applicable to Spray-Wall Interaction Including Film Characteristics with Validation at High Pressure and Temperature Conditions

Internal combustion engines have seen a great evolution over the last several decades through application of high pressure direct injection, multiple injections, and other technologies to reduced fuel consumption, NOx, and PM. Although combustion systems with advanced injection strategies have been studied extensively, there exists a significant fundamental knowledge gap on the fuel-spray interactions with the piston surface and chamber walls. Advanced computational codes validated with experimental techniques have to be developed for accurate representation of the drop impingement, fuel film formation, and vaporization. Current engine CFD (Computational Fluid Dynamics) spray models utilize a Lagrangian framework for modeling which lacks critical considerations of the physics pertaining to these interactions and thus requiring extensive parameterization, tuning and validation. The team from Michigan Technological University, University of Massachusetts Dartmouth, and Argonne National Laboratory is composed of experts in sprays, combustion, engines and CFD with a wide spectrum of knowledge including specific expertise in the area under consideration. In the proposed work, a VOF (Volume of Fluid) modeling approach has been adopted for the spray-wall interaction, film formation and spreading, and vaporization. With the inclusion of a vaporization submodel, a more predictive and accurate simulation of the spray-film was performed without extensive need of parameterization and tuning. Extensive experimentation of the spray-wall interaction under the range of conditions matching the thermodynamic and surface temperatures that occur in diesel and gasoline engines were conducted to validate the SWI submodels and for development of the evaporation submodel, which has been implemented in the flow solver.

42 ENGINEERING↗

Saltstone SDU6 Modeling Study

A new disposal unit, designated as Saltstone Disposal Unit 6 (SDU6), is being designed for support of site accelerated closure goals and salt waste projections identified in the new Liquid Waste System Plan. The unit is a cylindrical disposal cell of 375 ft in diameter and 43 ft in height, and it has a minimum 30 million gallons of capacity. SRNL was requested to evaluate the impact of an increased grout placement height on the flow patterns radially spread on the floor and to determine whether grout quality is impacted by the height. The primary goals of the work are to develop the baseline Computational Fluid Dynamics (CFD) model and to perform the evaluations for the flow patterns of grout material in SDU6 as a function of elevation of grout discharge port and grout rheology. Two transient grout models have been developed by taking a three-dimensional multiphase CFD approach to estimate the domain size of the grout materials radially spread on the facility floor and to perform the sensitivity analysis with respect to the baseline design and operating conditions such as elevation height of the discharge port and fresh grout properties. For the CFD modeling calculations, air-grout Volume of Fluid (VOF) method combined with Bingham plastic and time-dependent grout models were used for examining the impact of fluid spread performance for the initial baseline configurations and to evaluate the impact of grout pouring height on grout quality. The grout quality was estimated in terms of the air volume fraction for the grout layer formed on the SDU6 floor, resulting in the change of grout density. The study results should be considered as preliminary scoping analyses since benchmarking analysis is not included in this task scope. Transient analyses with the Bingham plastic model were performed with the FLUENT TM code on the high performance parallel computing platform in SRNL. The analysis coupled with a transient grout aging model was performed by using ANSYS-CFX code in the parallel computing platform in Mercer University. Recommended operational guidance was developed assuming that local shear rates and flow patterns related to radial spread along the SDU floor can be used as a measure of grout performance and spatial dispersion affected by the grout height and viscosity. The main conclusions drawn from the grout modeling and calculations are as follows: • The 5 ft height baseline results show that when the 150 gpm grout flow with a 5 Pa yield stress and a 60 cp viscosity is poured down through a 3 inch discharge port, the grout is spread radially up to about 64 ft distance from the pouring center after 2 hours’ pouring time. The air volume fraction of the grout layer is about 29% at 5 minutes’ transient time, and it is reduced by about 9% in 2 hours’ pouring time, resulting in the grout density consisting of about 80% grout and 20% air volume fractions. • The sensitivity results show that when the discharge port is located at a higher position, a larger amount of air is trapped inside the layer formed below the discharge port at the early transient time of less than 30 minutes because of the higher impinging momentum of the grout flow on the floor, resulting in the formation of less smooth layer. • The results clearly indicate that the radial spread for the 43 ft discharge port is about 10% faster than that of the 5 ft discharge port for the early transient period of 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the radial distance spread on the disposal floor. • When grout quality is related to grout volume fraction, the grout volume fraction for the 43 ft discharge port has lower volume fraction than the 5 ft discharge port for the transient period of the first 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the grout volume fraction for the layer accumulated on the disposal floor. • A modified Bingham plastic model coupled with time-dependent viscosity behavior was developed for conducting the initial scoping calculations to assess the impact of fluid residence time on radial spreading and basic flow patterns. • The results for the transient viscosity model show that when grout material becomes more viscous, the thickness of the grout layer accumulated on the floor becomes higher, but the radial distance spread on the horizontal floor becomes smaller. The early transient results for the grout density with about 32% air volume fractions are in reasonable agreement with those of the idealized Bingham plastic model. • It is recommended that the current models developed here be benchmarked against the experimental results for critical applications of the modeling results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A material interface transition algorithm for multiphase flow

Volume tracking method, also referred to as the volume-of-fluid (VOF) method introduces 'numerical surface tension' that breaks a filament into a series of droplets whenever the filament is under-resolved. Adaptive mesh refinement can help avoid under-resolution, but a fully-developed flow will still generate filaments that cannot be resolved without enormous computational cost. We propose a complementary new approach that consists of transitioning to a continuous interface representation (i.e. without interface reconstruction) in regions of under-resolved interfacial curvature where volume tracking has become erroneous. The price of the continuous interface treatment is a small amount of numerica'l mass diffusion, even if the physical interface is immiscible. However, we have found that for certain measures, the overall accuracy is greatly improved by using our transitioning algorithm. The algorithm is developed in the context of the single fluid formulation of the incompressible Navier-Stokes equations. Numerical standard vortices advection test cases and Rayleigh-Taylor instability computations are presented to illustrate the transition algorithm potential.

42 ENGINEERING↗

Effects of fuel viscosity on the primary breakup dynamics of a high-speed liquid jet with comparison to X-ray radiography

One of the major concerns in combustion engines is the sensitivity of engine performance to fuel prop- erties. Recent works have shown that even slight differences in fuel properties can cause significant changes in performance and emission of an engine. In order to design the combustion engines with multi-fuel flexi- bilities, the precise assessment of fuel sensitivity on liquid jet atomization process is a prerequisite since the resulting fuel/air mixture is critical to the subsequent combustion process. The present study is focusing on the effect of physical fuel properties, mostly viscosity difference, on the breakup process of the liquid jet injected into still air. Two different jet fuels, CAT-A2 and CAT-C3, are considered here as surrogates for a fossil-based fuel and a bio-derived high-viscosity alternative fuel. The simulations are performed using the volume-of-fluid (VoF) interface tracking method coupled to Lagrangian particle method in order to capture the breakup instabilities of jets and the resulting droplets. The investigations take the actual geometry of the injector into account to resolve the unsteady flow phenomena inside the nozzle that impact the turbu- lence transition and atomization. The simulation results are compared to the experimental measurement using X-ray radiography. Both simulation and X-ray measurements consistently describe the effects of different fuels on the fundamental properties of atomization including the breakup length, transverse liquid volume fraction and the droplet sauter-mean-diameter. The application of a Detailed Numerical Simulation approach complemented by unique X-ray diagnostics is novel and providing new understanding and research directions in engine spray dynamics

Breakup instability↗

CFD Validation of Gas Injection in Flowing Mercury over Vertical Smooth and Grooved Wall

The Spallation Neutron Source (SNS) is an accelerator-based neutron source at Oak Ridge National Laboratory (ORNL).The nuclear spallation reaction occurs when a proton beam hits liquid mercury. This interaction causes thermal expansion of the liquid mercury which produces high pressure waves. When these pressure waves hit the target vessel wall, cavitation can occur and erode the wall. Research and development efforts at SNS include creation of a vertical protective gas layer between the flowing liquid mercury and target vessel wall to mitigate the cavitation damage erosion and extend the life time of the target. Since mercury is opaque, computational fluid dynamics (CFD) can be used as a diagnostic tool to see inside the liquid mercury and guide the experimental efforts. In this study, CFD simulations of three dimensional, unsteady, turbulent, two-phase flow of helium gas injection in flowing liquid mercury over smooth, vertically grooved and horizontally grooved walls are carried out with the commercially available CFD code Fluent-12 from ANSYS. The Volume of Fluid (VOF) model is used to track the helium-mercury interface. V-shaped vertical and horizontal grooves with 0.5 mm pitch and about 0.7 mm depth were machined in the transparent wall of acrylic test sections. Flow visualization data of helium gas coverage through transparent test sections is obtained with a high-speed camera at the ORNL target test facility (TTF). The helium gas mass flow rate is 8 mg/min and introduced through a 0.5 mm diameter port. The local mercury velocity is 0.9 m/s. In this paper, the helium gas flow rate and the local mercury velocity are kept constant for the three cases. Time integration of predicted helium gas volume fraction over time is done to evaluate the gas coverage and calculate the average thickness of the helium gas layer. The predicted time-integrated gas coverage over vertically grooved and horizontally grooved test sections is better than over a smooth wall. The simulations show that the helium gas is trapped inside the grooves. The predicted time-averaged gas coverage is in good qualitative agreement with the measured gas coverage.

43 PARTICLE ACCELERATORS↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗