Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of high quality interference fringes from both sides of a suitably designed hololens in the laser Doppler anemometer measurement volume

We report, for the first time to the best of our knowledge, the formation of high quality, evenly spaced, undistorted fringes in the measurement volume of a laser Doppler anemometer from both sides of a suitably designed hololens. Experiments are performed for the analysis of fringes formed at the measurement volume by real time monitoring and actual fringe field analysis techniques. The results indicate the qualitative as well as quantitative improvement of 66.58% in overall average normalised standard deviations of the width of the fringes formed by the proposed imaging configuration than that of the conventional imaging configuration. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Fringe Field Formed Inside LDA Measurement Volume Using Compact Two Hololens Imaging Systems

We have designed and fabricated four LDA optical setups consisting of aberration compensated four different compact two hololens imaging systems. We have experimentally investigated and realized a hololens recording geometry which is interferogram of converging spherical wavefront with mutually coherent planar wavefront. Proposed real time monitoring and actual fringe field analysis techniques allow complete characterizations of fringes formed at measurement volume and permit to evaluate beam quality, alignment and fringe uniformity with greater precision. After experimentally analyzing the fringes formed at measurement volume by all four imaging systems, it is found that fringes obtained using compact two hololens imaging systems get improved both qualitatively and quantitatively compared to that obtained using conventional imaging system. Results indicate qualitative improvement of non-uniformity in fringe thickness and micro intensity variations perpendicular to the fringes, and quantitative improvement of 39.25% in overall average normalized standard deviations of fringe width formed by compact two hololens imaging systems compare to that of conventional imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Bland-Altman Analysis of the Bias Between Computed Tomography and Ultrasound Prostate Volume Measurements

This study assesses the agreement between computed tomography (CT) measurements of prostate volume and those obtained by ultrasound (US), a well-established non-invasive technique. Twenty-six patients aged between 58 and 74 years were evaluated for prostate seed implant therapy using both CT and US measurements. The level of agreement between these 2 methods, which were strongly correlated (R{sup 2} = 0.828; p < 0.0001), was determined through Bland-Altman analysis. The mean prostate volume ({+-} one standard deviation) of the sample was 31.8 {+-} 10.5 cc for the CT method and 27.0 {+-} 8.2 cc for the US method. The prostate volumes obtained by CT were, on average, 17% larger than the corresponding volumes determined by US. The average bias between the 2 imaging methods is 4.80 cc or 15%, which is significantly larger than the clinically acceptable margin of 10%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed volume measurement system

Disclosed is a volume sensor having a first axis, a second axis, and a third axis, each axis including a laser source configured to emit a beam; a parallel beam generating assembly configured to receive the beam and split the beam into a first parallel beam and a second parallel beam, a beam-collimating assembly configured to receive the first parallel beam and the second parallel beam and output a first beam sheet and a second beam sheet, the first beam sheet and the second beam sheet being configured to traverse the object aperture; a first collecting lens and a second collecting lens; and a first photodetector and a second photodetector, the first photodetector and the second photodetector configured to output an electrical signal proportional to the object; wherein the first axis, the second axis, and the third axis are arranged at an angular offset with respect to each other.

42 ENGINEERING↗

Reheating-volume measure for random-walk inflation

The recently proposed 'reheating-volume' (RV) measure promises to solve the long-standing problem of extracting probabilistic predictions from cosmological multiverse scenarios involving eternal inflation. I give a detailed description of the new measure and its applications to generic models of eternal inflation of random-walk type. For those models I derive a general formula for RV-regulated probability distributions that is suitable for numerical computations. I show that the results of the RV cutoff in random-walk type models are always gauge invariant and independent of the initial conditions at the beginning of inflation. In a toy model where equal-time cutoffs lead to the 'youngness paradox', the RV cutoff yields unbiased results that are distinct from previously proposed measures.

79 ASTRONOMY AND ASTROPHYSICS↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed volume measurement system and method

Disclosed is a volume sensor having first, second, and third laser sources emitting first, second, and third laser beams; first, second, and third beam splitters splitting the first, second, and third laser beams into first, second, and third beam pairs; first, second, and third optical assemblies expanding the first, second, and third beam pairs into first, second, and third pairs of parallel beam sheets; fourth, fifth, and sixth optical assemblies focusing the first, second, and third beam sheet pairs into fourth, fifth, and sixth beam pairs; and first, second, and third detector pairs receiving the fourth, fifth, and sixth beam pairs and converting a change in intensity of at least one of the beam pairs resulting from an object passing through at least one of the first, second, and third parallel beam sheets into at least one electrical signal proportional to a three-dimensional representation of the object.

43 PARTICLE ACCELERATORS↗

High-speed volume measurement system and method

Disclosed is a volume sensor having first, second, and third laser sources emitting first, second, and third laser beams; first, second, and third beam splitters splitting the first, second, and third laser beams into first, second, and third beam pairs; first, second, and third optical assemblies expanding the first, second, and third beam pairs into first, second, and third pairs of parallel beam sheets; fourth, fifth, and sixth optical assemblies focusing the first, second, and third beam sheet pairs into fourth, fifth, and sixth beam pairs; and first, second, and third detector pairs receiving the fourth, fifth, and sixth beam pairs and converting a change in intensity of at least one of the beam pairs resulting from an object passing through at least one of the first, second, and third parallel beam sheets into at least one electrical signal proportional to a three-dimensional representation of the object.

47 OTHER INSTRUMENTATION↗

Reheating-volume measure in the string theory landscape

I recently proposed the ''reheating-volume'' (RV) prescription as a possible solution to the measure problem in ''multiverse'' cosmology. The goal of this work is to extend the RV measure to scenarios involving bubble nucleation, such as the string theory landscape. In the spirit of the RV prescription, I propose to calculate the distribution of observable quantities in a landscape that is conditioned in probability to nucleate a finite total number of bubbles to the future of an initial bubble. A general formula for the relative number of bubbles of different types can be derived. I show that the RV measure is well defined and independent of the choice of the initial bubble type, as long as that type supports further bubble nucleation. Applying the RV measure to a generic landscape, I find that the abundance of Boltzmann brains is always negligibly small compared with the abundance of ordinary observers in the bubbles of the same type. As an illustration, I present explicit results for a toy landscape containing four vacuum states, and for landscapes with a single high-energy vacuum and a large number of low-energy vacua.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Volume measurement of cryogenic deuterium pellets by Bayesian analysis of single shadowgraphy images

In situ commissioning of the Blower-gun injector for launching cryogenic deuterium pellets at ASDEX Upgrade tokamak was performed. This injector is designed for high repetitive launch of small pellets for edge localised modes pacing experiments. During the investigation the final injection geometry was simulated with pellets passing to the torus through a 5.5 m long guiding tube. For investigation of pellet quality at launch and after tube passage laser flash camera shadowgraphy diagnostic units before and after the tube were installed. As indicator of pellet quality we adopted the pellet mass represented by the volume of the main remaining pellet fragment. Since only two-dimensional (2D) shadow images were obtained, a reconstruction of the full three-dimensional pellet body had to be performed. For this the image was first converted into a 1-bit version prescribing an exact 2D contour. From this contour the expected value of the volume was calculated by Bayesian analysis taking into account the likely cylindrical shape of the pellet. Under appropriate injection conditions sound pellets with more than half of their nominal mass are detected after acceleration; the passage causes in average an additional loss of about 40% to the launched mass. Analyzing pellets arriving at tube exit allowed for deriving the injector's optimized operational conditions. For these more than 90% of the pellets were arriving with sound quality when operating in the frequency range 5-50 Hz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dedicated breast CT: Fibroglandular volume measurements in a diagnostic population

Purpose: To determine the mean and range of volumetric glandular fraction (VGF) of the breast in a diagnostic population using a high-resolution flat-panel cone-beam dedicated breast CT system. This information is important for Monte Carlo-based estimation of normalized glandular dose coefficients and for investigating the dependence of VGF on breast dimensions, race, and pathology. Methods: Image data from a clinical trial investigating the role of dedicated breast CT that enrolled 150 women were retrospectively analyzed to determine the VGF. The study was conducted in adherence to a protocol approved by the institutional human subjects review boards and written informed consent was obtained from all study participants. All participants in the study were assigned BI-RADS{sup Registered-Sign} 4 or 5 as per the American College of Radiology assessment categories after standard diagnostic work-up and underwent dedicated breast CT exam prior to biopsy. A Gaussian-kernel based fuzzy c-means algorithm was used to partition the breast CT images into adipose and fibroglandular tissue after segmenting the skin. Upon determination of the accuracy of the algorithm with a phantom, it was applied to 137 breast CT volumes from 136 women. VGF was determined for each breast and the mean and range were determined. Pathology results with classification as benign, malignant, and hyperplasia were available for 132 women, and were used to investigate if the distributions of VGF varied with pathology. Results: The algorithm was accurate to within {+-}1.9% in determining the volume of an irregular shaped phantom. The study mean ({+-} inter-breast SD) for the VGF was 0.172 {+-} 0.142 (range: 0.012-0.719). VGF was found to be negatively correlated with age, breast dimensions (chest-wall to nipple length, pectoralis to nipple length, and effective diameter at chest-wall), and total breast volume, and positively correlated with fibroglandular volume. Based on pathology, pairwise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there was no significant difference in distributions of VGF without adjustment for age between malignant and nonmalignant breasts (p= 0.41). Pairwise comparisons of the distributions of VGF in increasing order of mammographic breast density indicated all comparisons were statistically significant (p < 0.002). Conclusions: This study used a different clinical prototype breast CT system than that in previous studies to image subjects from a different geographical region, and used a different algorithm for analysis of image data. The mean VGF estimated from this study is within the range reported in previous studies, indicating that the choice of 50% glandular weight fraction to represent an average breast for Monte Carlo-based estimation of normalized glandular dose coefficients in mammography needs revising. In the study, the distributions of VGF did not differ significantly with pathology.

60 APPLIED LIFE SCIENCES↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

AAPM Task Group 128: Quality assurance tests for prostate brachytherapy ultrasound systems

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostate brachytherapy. Accurate imaging guidance and dosimetry calculation depend upon the quality and accuracy of the ultrasound image. Therefore, a robust quality assurance program for the ultrasound system is essential. A brief review of prostate brachytherapy and ultrasound physics is provided, followed by a recommendation for elements to be included in a comprehensive test phantom. Specific test recommendations are presented, covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, needle template/electronic grid alignment, and geometric consistency with the treatment planning computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

60 APPLIED LIFE SCIENCES↗