A coupling strategy for nonlocal and local diffusion models with mixed volume constraints and boundary conditions
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Purpose: Radical radiotherapy for prostate cancer is effective but dose limited because of the proximity of normal tissues. Comprehensive dose-volume analysis of the incidence of clinically relevant late rectal toxicities could indicate how the dose to the rectum should be constrained. Previous emphasis has been on constraining the mid-to-high dose range (>=50 Gy). Evidence is emerging that lower doses could also be important. Methods and Materials: Data from a large multicenter randomized trial were used to investigate the correlation between seven clinically relevant rectal toxicity endpoints (including patient- and clinician-reported outcomes) and an absolute 5% increase in the volume of rectum receiving the specified doses. The results were quantified using odds ratios. Rectal dose-volume constraints were applied retrospectively to investigate the association of constraints with the incidence of late rectal toxicity. Results: A statistically significant dose-volume response was observed for six of the seven endpoints for at least one of the dose levels tested in the range of 30-70 Gy. Statistically significant reductions in the incidence of these late rectal toxicities were observed for the group of patients whose treatment plans met specific proposed dose-volume constraints. The incidence of moderate/severe toxicity (any endpoint) decreased incrementally for patients whose treatment plans met increasing numbers of dose-volume constraints from the set of V30<=80%, V40<=65%, V50<=55%, V60<=40%, V65<=30%, V70<=15%, and V75<=3%. Conclusion: Considering the entire dose distribution to the rectum by applying dose-volume constraints such as those tested here in the present will reduce the incidence of late rectal toxicity.
This work presents a probabilistic scheme for solving semilinear nonlocal diffusion equations with volume constraints and integrable kernels. The nonlocal model of interest is defined by a time-dependent semilinear partial integro-differential equation (PIDE), in which the integro-differential operator consists of both local convection-diffusion and nonlocal diffusion operators. Here, our numerical scheme is based on the direct approximation of the nonlinear Feynman–Kac formula that establishes a link between nonlinear PIDEs and stochastic differential equations. The exploitation of the Feynman–Kac representation avoids solving dense linear systems arising from nonlocal operators. Compared with existing stochastic approaches, our method can achieve first-order convergence after balancing the temporal and spatial discretization errors, which is a significant improvement of existing probabilistic/stochastic methods for nonlocal diffusion problems. Error analysis of our numerical scheme is established. The effectiveness of our approach is shown in two numerical examples. The first example considers a three-dimensional nonlocal diffusion equation to numerically verify the error analysis results. The second example presents a physics problem motivated by the study of heat transport in magnetically confined fusion plasmas.
Purpose: Treatment plan optimization in multi-Co60 source focused radiotherapy with multiple isocenters is challenging, because dose distribution is normalized to maximum dose during optimization and evaluation. The objective functions are traditionally defined based on relative dosimetric distribution. This study presents an alternative absolute dose-volume constraint (ADC) based deterministic optimization framework (ADC-DOF). Methods: The initial isocenters are placed on the eroded target surface. Collimator size is chosen based on the area of 2D contour on corresponding axial slice. The isocenter spacing is determined by adjacent collimator sizes. The weights are optimized by minimizing the deviation from ADCs using the steepest descent technique. An iterative procedure is developed to reduce the number of isocenters, where the isocenter with lowest weight is removed without affecting plan quality. The ADC-DOF is compared with the genetic algorithm (GA) using the same arbitrary shaped target (254cc), with a 15mm margin ring structure representing normal tissues. Results: For ADC-DOF, the ADCs imposed on target and ring are (D100>10Gy, D50,10, 0<12Gy, 15Gy and 20Gy) and (D40<10Gy). The resulting D100, 50, 10, 0 and D40 are (9.9Gy, 12.0Gy, 14.1Gy and 16.2Gy) and (10.2Gy). The objectives of GA are to maximize 50% isodose target coverage (TC) while minimize the dose delivered to the ring structure, which results in 97% TC and 47.2% average dose in ring structure. For ADC-DOF (GA) techniques, 20 out of 38 (10 out of 12) initial isocenters are used in the final plan, and the computation time is 8.7s (412.2s) on an i5 computer. Conclusion: We have developed a new optimization technique using ADC and deterministic optimization. Compared with GA, ADC-DOF uses more isocenters but is faster and more robust, and achieves a better conformity. For future work, we will focus on developing a more effective mechanism for initial isocenter determination.
Drill rig parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. While insightful into the drilling process, these measurements are of reduced value without a standard to aid in data evaluation and decision making. In the main body of this work (Volume 1), a method is demonstrated whereby rock reduction model constraints are used to interpret drilling response parameters; the method could be applied in real-time to improve decision-making in the field and to further discern technology performance during post-drilling evaluations. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) in computational algorithms. The method presented has applicability to development of advanced analytics on future geothermal wells using real-time electronic data recording for improved performance and reduced drilling costs. A drilling cost model is also used to show the tradeoff between rate of penetration and bit life and the influence on interval drilling costs. Details of the bit specifications and performance are cataloged in an independent volume, documented under separate cover, for each of the four wells, and include Volume 2: Utah FORGE 16A(78)-32; Volume 3: Utah FORGE 56-32; Volume 4: Utah FORGE 78B-32 and Volume 5: Utah FORGE 16B(78)-32.
Drill rig parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. While insightful into the drilling process, these measurements are of reduced value without a standard to aid in data evaluation and decision making. In the main body of this work (Volume 1), a method is demonstrated whereby rock reduction model constraints are used to interpret drilling response parameters; the method could be applied in real-time to improve decision-making in the field and to further discern technology performance during post-drilling evaluations. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) in computational algorithms. The method presented has applicability to development of advanced analytics on future geothermal wells using real-time electronic data recording for improved performance and reduced drilling costs. A drilling cost model is also used to show the tradeoff between rate of penetration and bit life and the influence on interval drilling costs. Details of the bit specifications and performance are cataloged in an independent volume, documented under separate cover, for each of the four wells, and include Volume 2: Utah FORGE 16A(78)-32; Volume 3: Utah FORGE 56-32; Volume 4: Utah FORGE 78B-32 and Volume 5: Utah FORGE 16B(78)-32.
Drill rig parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. While insightful into the drilling process, these measurements are of reduced value without a standard to aid in data evaluation and decision making. In the main body of this work (Volume 1), a method is demonstrated whereby rock reduction model constraints are used to interpret drilling response parameters; the method could be applied in real-time to improve decision-making in the field and to further discern technology performance during post-drilling evaluations. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) in computational algorithms. The method presented has applicability to development of advanced analytics on future geothermal wells using real-time electronic data recording for improved performance and reduced drilling costs. A drilling cost model is also used to show the tradeoff between rate of penetration and bit life and the influence on interval drilling costs. Details of the bit specifications and performance are cataloged in an independent volume, documented under separate cover, for each of the four wells, and include Volume 2: Utah FORGE 16A(78)-32; Volume 3: Utah FORGE 56-32; Volume 4: Utah FORGE 78B-32 and Volume 5: Utah FORGE 16B(78)-32.
Drill rig parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. While insightful into the drilling process, these measurements are of reduced value without a standard to aid in data evaluation and decision making. In the main body of this work (Volume 1), a method is demonstrated whereby rock reduction model constraints are used to interpret drilling response parameters; the method could be applied in real-time to improve decision-making in the field and to further discern technology performance during post-drilling evaluations. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) in computational algorithms. The method presented has applicability to development of advanced analytics on future geothermal wells using real-time electronic data recording for improved performance and reduced drilling costs. A drilling cost model is also used to show the tradeoff between rate of penetration and bit life and the influence on interval drilling costs. Details of the bit specifications and performance are cataloged in an independent volume, documented under separate cover, for each of the four wells, and include Volume 2: Utah FORGE 16A(78)-32; Volume 3: Utah FORGE 56-32; Volume 4: Utah FORGE 78B-32 and Volume 5: Utah FORGE 16B(78)-32.
Purpose: Determine equivalent Organ at Risk (OAR) tolerance dose (TD) constraints for MV x-rays and particle therapy. Methods: Equivalent TD estimates for MV x-rays are determined from an isoeffect, regression-analysis of published and in-house constraints for various fractionation schedules (n fractions). The analysis yields an estimate of (α/β) for an OAR. To determine equivalent particle therapy constraints, the MV x-ray TD(n) values are divided by the RBE for DSB induction (RBE{sub DSB}) or cell survival (RBE{sub S}). Estimates of (RBE{sub DSB}) are computed using the Monte Carlo Damage Simulation, and estimates of RBES are computed using the Repair-Misrepair-Fixation (RMF) model. A research build of the RayStation™ treatment planning system implementing the above model is used to estimate (RBE{sub DSB}) for OARs of interest in 16 proton therapy patient plans (head and neck, thorax, prostate and brain). Results: The analysis gives an (α/β) estimate of about 20 Gy for the trachea and heart and 2–4 Gy for the esophagus, spine, and brachial plexus. Extrapolation of MV x-ray constraints (n = 1) to fast neutrons using RBE{sub DSB} = 2.7 are in excellent agreement with clinical experience (n = 10 to 20). When conventional (n > 30) x-ray treatments are used as the reference radiation, fast neutron RBE increased to a maximum of 6. For comparison to a constant RBE of 1.1, the RayStation™ analysis gave estimates of proton RBE{sub DSB} from 1.03 to 1.33 for OARs of interest. Conclusion: The presented system of models is a convenient formalism to synthesize from multiple sources of information a set of self-consistent plan constraints for MV x-ray and hadron therapy treatments. Estimates of RBE{sub DSB} from the RayStation™ analysis differ substantially from 1.1 and vary among patients and treatment sites. A treatment planning system that incorporates patient and anatomy-specific corrections in proton RBE would create opportunities to increase the therapeutic ratio. The research build of the RayStation used in the study was made available to the University of Washington free of charge. RaySearch Laboratories did not provide any monetary support for the reported studies.
Abstract Not Provided
Abstract Not Provided
Abstract not provided.
Purpose: To compare dose volume histograms of intensity-modulated proton therapy (IMPT) with those of intensity-modulated radiation therapy (IMRT) and passive scattering proton therapy (PSPT) for the treatment of stage IIIB non-small-cell lung cancer (NSCLC) and to explore the possibility of individualized radical radiotherapy. Methods and Materials: Dose volume histograms designed to deliver IMRT at 60 to 63 Gy, PSPT at 74 Gy, and IMPT at the same doses were compared and the use of individualized radical radiotherapy was assessed in patients with extensive stage IIIB NSCLC (n = 10 patients for each approach). These patients were selected based on their extensive disease and were considered to have no or borderline tolerance to IMRT at 60 to 63 Gy, based on the dose to normal tissue volume constraints (lung volume receiving 20 Gy [V20] of <35%, total mean lung dose <20 Gy; spinal cord dose, <45 Gy). The possibility of increasing the total tumor dose with IMPT for each patient without exceeding the dose volume constraints (maximum tolerated dose [MTD]) was also investigated. Results: Compared with IMRT, IMPT spared more lung, heart, spinal cord, and esophagus, even with dose escalation from 63 Gy to 83.5 Gy, with a mean MTD of 74 Gy. Compared with PSPT, IMPT allowed further dose escalation from 74 Gy to a mean MTD of 84.4 Gy (range, 79.4-88.4 Gy) while all parameters of normal tissue sparing were kept at lower or similar levels. In addition, IMPT prevented lower-dose target coverage in patients with complicated tumor anatomies. Conclusions: IMPT reduces the dose to normal tissue and allows individualized radical radiotherapy for extensive stage IIIB NSCLC.
Purpose: To establish planning solutions for a concomitant three-level radiation dose distribution to the breast using linear accelerator- or tomotherapy-based intensity-modulated radiotherapy (IMRT), for the U.K. Intensity Modulated and Partial Organ (IMPORT) High trial. Methods and Materials: Computed tomography data sets for 9 patients undergoing breast conservation surgery with implanted tumor bed gold markers were used to prepare three-level dose distributions encompassing the whole breast (36 Gy), partial breast (40 Gy), and tumor bed boost (48 or 53 Gy) treated concomitantly in 15 fractions within 3 weeks. Forward and inverse planned IMRT and tomotherapy were investigated as solutions. A standard electron field was compared with a photon field arrangement encompassing the tumor bed boost volume. The out-of-field doses were measured for all methods. Results: Dose-volume constraints of volume >90% receiving 32.4 Gy and volume >95% receiving 50.4 Gy for the whole breast and tumor bed were achieved. The constraint of volume >90% receiving 36 Gy for the partial breast was fulfilled in the inverse IMRT and tomotherapy plans and in 7 of 9 cases of a forward planned IMRT distribution. An electron boost to the tumor bed was inadequate in 8 of 9 cases. The IMRT methods delivered a greater whole body dose than the standard breast tangents. A contralateral lung volume >2.5 Gy was increased in the inverse IMRT and tomotherapy plans, although it did not exceed the constraint. Conclusion: We have demonstrated a set of widely applicable solutions that fulfilled the stringent clinical trial requirements for the delivery of a concomitant three-level dose distribution to the breast.
Not Available
We introduce a Matlab implementation of topology optimization for compliance minimization on unstructured polygonal finite element meshes that efficiently accommodates many materials and many volume constraints. Leveraging the modular structure of the educational code, PolyTop, we extend it to the multi-material version, PolyMat, with only a few modifications. First, a design variable for each candidate material is defined in each finite element. Next, we couple a Discrete Material Optimization interpolation with the existing penalization and introduce a new parameter such that we can employ continuation and smoothly transition from a convex problem without any penalization to a non-convex problem in which material mixing and intermediate densities are penalized. Mixing that remains due to the density filter operation is eliminated via continuation on the filter radius. To accommodate flexibility in the volume constraint definition, the constraint function is modified to compute multiple volume constraints and the design variable update is modified in accordance with the Zhang-Paulino-Ramos Jr. (ZPR) update scheme, which updates the design variables associated with each constraint independently. The formulation allows for volume constraints controlling any subset of the design variables, i.e., they can be defined globally or locally for any subset of the candidate materials. Borrowing ideas for mesh generation on complex domains from PolyMesher, we conclude which design variables are associated with each local constraint of arbitrary geometry. A number of examples are presented to demonstrate the many material capability, the flexibility of the volume constraint definition, the ease with which we can accommodate passive regions, and how we may use local constraints to break symmetries or achieve graded geometries.
Purpose: The study aimed to apply the atlas of complication incidence (ACI) method to patients receiving radical treatment for head and neck squamous cell carcinomas (HNSCC), to generate constraints based on dose-volume histograms (DVHs), and to identify clinical and dosimetric parameters that predict the risk of grade 3 oral mucositis (g3OM) and pharyngeal dysphagia (g3PD). Methods and Materials: Oral and pharyngeal mucosal DVHs were generated for 253 patients who received radiation (RT) or chemoradiation (CRT). They were used to produce ACI for g3OM and g3PD. Multivariate analysis (MVA) of the effect of dosimetry, clinical, and patient-related variables was performed using logistic regression and bootstrapping. Receiver operating curve (ROC) analysis was also performed, and the Youden index was used to find volume constraints that discriminated between volumes that predicted for toxicity. Results: We derived statistically significant dose-volume constraints for g3OM over the range v28 to v70. Only 3 statistically significant constraints were derived for g3PD v67, v68, and v69. On MVA, mean dose to the oral mucosa predicted for g3OM and concomitant chemotherapy and mean dose to the inferior constrictor (IC) predicted for g3PD. Conclusions: We have used the ACI method to evaluate incidences of g3OM and g3PD and ROC analysis to generate constraints to predict g3OM and g3PD derived from entire individual patient DVHs. On MVA, the strongest predictors were radiation dose (for g3OM) and concomitant chemotherapy (for g3PD).
Purpose: We extended our previous experience with stereotactic ablative radiation therapy (SABR; 50 Gy in 4 fractions) for centrally located non-small cell lung cancer (NSCLC); explored the use of 70 Gy in 10 fractions for cases in which dose-volume constraints could not be met with the previous regimen; and suggested modified dose-volume constraints. Methods and Materials: Four-dimensional computed tomography (4DCT)-based volumetric image-guided SABR was used for 100 patients with biopsy-proven, central T1-T2N0M0 (n=81) or isolated parenchymal recurrence of NSCLC (n=19). All disease was staged with positron emission tomography/CT; all tumors were within 2 cm of the bronchial tree, trachea, major vessels, esophagus, heart, pericardium, brachial plexus, or vertebral body. Endpoints were toxicity, overall survival (OS), local and regional control, and distant metastasis. Results: At a median follow-up time of 30.6 months, median OS time was 55.6 months, and the 3-year OS rate was 70.5%. Three-year cumulative actuarial local, regional, and distant control rates were 96.5%, 87.9%, and 77.2%, respectively. The most common toxicities were chest-wall pain (18% grade 1, 13% grade 2) and radiation pneumonitis (11% grade 2 and 1% grade 3). No patient experienced grade 4 or 5 toxicity. Among the 82 patients receiving 50 Gy in 4 fractions, multivariate analyses showed mean total lung dose >6 Gy, V{sub 20} >12%, or ipsilateral lung V{sub 30} >15% to independently predict radiation pneumonitis; and 3 of 9 patients with brachial plexus D{sub max} >35 Gy experienced brachial neuropathy versus none of 73 patients with brachial D{sub max} <35 Gy (P=.001). Other toxicities were analyzed and new dose-volume constraints are proposed. Conclusions: SABR for centrally located lesions produces clinical outcomes similar to those for peripheral lesions when normal tissue constraints are respected.