Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Virtual detector method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron Quantum Dynamics in Strong-Field Irradiation

The major goal of the project was to investigate the nonsequential ionization dynamics of atomic systems with two active electrons under intense laser irradiation. In order to gain insights into such nonlinear dynamical systems, one must resort to clever numerical methods due to the poor scaling of computational memory and time. Accordingly, we have extended the virtual detector method of Feuerstein and Thumm by incorporating quasi-classical “virtual” particles that evolve alongside the Schrödinger wavefunction. A major and recent part of this research effort was to further extend the virtual-detector method to model a two-active-electron atomic system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strong-field nonsequential double photoionization using virtual-detector theory with path summation

We present an ab initio study of the nonsequential strong-field ionization dynamics of a model two-electron atom with helium character. Single- and double-ionization events are characterized and displayed using detector signals extracted at different points in the two-electron two-dimensional space. The double photoelectron momentum distribution is calculated via coherent path-summation over virtual-particle trajectories. A comparison is made between the momentum distributions obtained with the virtual-detector method, the Schrödinger wave function, and the time-dependent surface flux method developed by Tao and Scrinzi [New J. Phys. 14, 013021 (2012)]. Insights into different ionization and electron recollision pathways are gained from detailed virtual-particle tracking and energy-time readouts. Furthermore, this study demonstrates the extension of virtual-detector theory to strong-field multielectron quantum dynamics and highlights the importance of the evolving quantum phase in quasiclassical electron propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a synthetic fast ion loss detector model for Wendelstein 7-X

Abstract We present the first validated synthetic diagnostic for fast ion loss detectors (FILDs) in the Wendelstein 7-X (W7-X) stellarator. This model has been developed on, and validated against experimental data from, a FILD provided by the National Institute for Fusion Science (NIFS-FILD), with potential future applicability to the existing Faraday Cup FILD (FC-FILD) on W7-X as well as the scintillating FILD (S-FILD) currently under development. A workflow combining Monte Carlo codes BEAMS3D and ASCOT5 is used to track fast ions produced by neutral beam injection from the moment of ionization until they are thermalized or lost from the last closed flux surface, and from there to a virtual plane which serves as a projection of the entrance aperture to the FILD. Simulations in ASCOT5 are analyzed via a geometric method to determine the probability of transmission through the FILD aperture and onto the detector as a function of normalized momentum, pitch angle, gyrophase, and position at the virtual plane. This probability is then applied to the simulated ions arriving from the plasma, producing a simulated signal from a computationally tractable number of simulated fast ions. Simulated signals are presented for two W7-X experiments with neutral beam injection and quantitatively compared with experimental measurements from the NIFS-FILD diagnostic. An estimate of the frequency of charge-exchange with neutral particles in the edge is performed, and it is found that this process may have a significant impact on the measured signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of 6D Phase Space

A ‘Phase Space’ is a mathematical representation of all possible physical states of matter of a physical volume or system. Particle beams at Fermilab exist in a six-dimensional phase space: three position dimensions, and three momentum dimensions. To ‘reconstruct’ that space means to take measurement data from virtual detectors along those beams and map out where particles are and how they’re moving, using computational methods. In this experiment, we simulated a particle beam (Fig 1) and used the position distribution of each particle at each detector to map out the magnitude of the beam’s initial momentum.

Shirlee, Jermaine [DuPage Coll.]↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Roper Resonance Structure and Exploration of Emergent Hadron Mass from CLAS Electroproduction Data

The N(1440)1/2 + nucleon resonance, first identified in 1964 by Roper and collaborators in analyses of πN hadroproduction data, has continued to provide pivotal insights that serve to advance our understanding of nucleon excited states. In this contribution, we present results from studies of the structure of the Roper resonance based on exclusive πN and π + π − p electro production data measured with the CLAS detector at Jefferson Lab. These analyses have revealed the Roper resonance as a complex interplay between an inner core of three dressed quarks and an external meson–baryon cloud. Analyses of the CLAS results on the evolution of the Roper resonance electroexcitation amplitudes with photon virtuality Q 2 , within the framework of the Continuum Schwinger Method, have conclusively demonstrated the capability to gain insight into the strong interaction dynamics responsible for generating more than 98% of hadron mass. Further extension of such studies to higher Q 2 , through experiments currently underway with the CLAS12 detector and in the future with a potential CEBAF energy upgrade to 22 GeV, offers the only foreseeable opportunity to explore the full range of distances where the dominant portion of hadron mass and resonance structure emerge.

Mokeev, Victor I. [Thomas Jefferson National Accel↗

Cross Section Evaluation for Exclusive Channels of K+Λ and K+Σ0 Electroproduction off Protons Using CLAS Detector Data

In this work, a method for evaluating the cross sections of electroproduction of K+Λ0 and K+Σ0 off protons in the region of invariant masses of final hadrons MK + MY <W < 2.65 GeV (MK and MY being the masses of the kaon and hyperon, respectively) and squares of four-momentum transfers of virtual photons, i.e., photon virtualities 0 < Q2 < 5 GeV2, is developed based on experimental data of these exclusive channels’ cross sections measured by the CLAS detector in Hall B at Jefferson Lab. A set of algorithms has been implemented to evaluate the differential cross sections of these channels, along with their statistical and systematic uncertainties. A program was developed for the evaluation of differential cross sections and structure functions using C++ and Python libraries. An interactive website was created for working with the program, enabling the analysis of one-dimensional and two-dimensional dependences of structure functions and differential cross sections. The evaluation of differential cross sections for the K+Λ and K+Σ0 electroproduction channels is necessary for extracting the structure function σLT from the data on the polarization asymmetry of electroproduction reactions of these final states with longitudinally polarized electrons. The obtained results are also important for the development of realistic Monte Carlo event generators in planning future experiments and for evaluating the efficiency of detecting final particles when extracting reaction cross sections from experimental data.

Golda, A. V.↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring baryon resonances with transition generalized parton distributions: status and perspectives

QCD gives rise to a rich spectrum of excited baryon states. Understanding their internal structure is important for many areas of nuclear physics, such as nuclear forces, dense matter, and neutrino-nucleus interactions. Generalized parton distributions (GPDs) are an established tool for characterizing the QCD structure of the ground-state nucleon. They are used to create 3D tomographic images of the quark/gluon structure and quantify the mechanical properties such as the distribution of mass, angular momentum, and forces in the system. Transition GPDs extend these concepts to N → N* transitions and can be used to characterize the 3D structure and mechanical properties of baryon resonances. They can be probed in high-momentum-transfer exclusive electroproduction processes with resonance transitions e + N → e' + M + N*, such as deeply-virtual Compton scattering (M = γ) or meson production (M = π, K, etc.), and in related photon/hadron-induced processes. This White Paper describes a research program aiming to explore baryon resonance structure with transition GPDs. This includes the properties and interpretation of the transition GPDs, theoretical methods for structures and processes, first experimental results from JLab 12 GeV, future measurements with existing and planned facilities (JLab detector and energy upgrades, COMPASS/AMBER, EIC, EicC, J-PARC, LHC ultraperipheral collisions), and the theoretical and experimental developments needed to realize this program.

Experimental Nuclear Physics↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Uncertainty in Experimental Data Analysis [Slides]

The talk was presented virtually to the Institute of Fundamental Technological Research, Polish Academy of Sciences in Warsaw, Poland, December 21, 2020. Astronomical observations, unusual medical cases, physics experiments too costly to repeat, natural events like earthquakes, hurricanes – all of them are impossible to repeat yet produce important scientific information not achievable in other way. This data should not be treated as qualitative, anecdotal evidence only. It should be analyzed in a mathematically rigorous way to produce quantitative experimental data. Analysis method for one-of-a-kind event data differs from analysis of a repeated experiment data. For a repeated experiments the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single true experimental value. Measurement uncertainty depends on the measurement system only. Modern digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one-of-a-kind experiment are analyzed, only the measurement uncertainty can be reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VERA User's Guide for Ex-core Applications

The Virtual Environment for Reactor Applications, or VERA, allows users to set up models to calculate time-dependent and fully coupled solutions for ex-core quantities of interest such as vessel and coupon fluence, and detector responses for multiple statepoints and cycles. MPACT and COBRA-TF together perform in-core transport calculations with temperature feedback while Shift performs the fluence and detector response calculations in the ex-core region. The in-core region is modeled using VERA’s native input format and the ex-core region is defined using Shift’s general geometry package, also known as Omnibus General Geometry. Fixed source ex-core calculations with Shift can be run in forward mode without advanced variance reduction (VR) methods, or with Consistent Adjoint Driven Importance Sampling (CADIS), which is an automated VR method. This document serves as a guide for setting up inputs, running ex-core calculations and post-processing the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Insight into Strong QCD and the Emergence of Mass from N* Experiments

Studies of nucleon resonance (N*) electroexcitation amplitudes (?vpN* electrocouplings) within a broad range of virtual photon four-momentum squared Q2 offer unique information on many facets of the strong interaction in the regime of large QCD running coupling (sQCD regime) seen in the generation of different resonances. The results on the ?vpN* electrocouplings from exclusive meson electroproduction data measured with the CLAS detector at JLab and their impact on understanding of sQCD dynamics will be presented in this talk. These CLAS data have provided the first and only available results on the evolution of the ?vpN* electrocouplings with Q2 to 5 GeV2 for most N* states in the mass range up to 1.8 GeV. A successful description of the CLAS results on the Q2-evolution of the ?(1232)3/2+, N(1440)1/2+, and ?(1600)3/2+ electrocouplings has been achieved within the continuum Schwinger method (CSM) by employing the same momentum dependence of the dressed quark mass inferred from the QCD Lagrangian, which also reproduces the experimental results on the pion elastic electromagnetic form factor and parton distribution function, and the nucleon elastic form factor. This success has demonstrated the capability for gaining insight into the emergence of hadron mass (EHM) from the exploration of the Q2-evolution of the ?vpN* electrocouplings. These studies also allow us to establish either universality or environmental sensitivity of the dressed quark mass function and to explore qq-correlation amplitudes of different spin-parities and the mixing between configurations of different orbital angular momentum. Exploration of the resonance electroexcitation with the CLAS12 detector and in the future with a possible 22 GeV machine at JLab offer the only foreseen opportunity to extend information on the ?vpN* electrocouplings for Q2 from 5-30 GeV2. Analyses of these results will cover the full range of distances where the dominant part of hadron mass and N* structure emerge from QCD.

Mokeev, Victor↗