Burst diaphragm protects vacuum vessel from internal pressure transients
Supported dual-mode burst diaphragm protects vacuum vessels from transient internal pressures. It forms the interface between the vacuum in the vessel and an external pressure.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Supported dual-mode burst diaphragm protects vacuum vessels from transient internal pressures. It forms the interface between the vacuum in the vessel and an external pressure.
Isoparametric quadrilateral and triangular elements were used to represent the vacuum vessel shell structure. For toroidally symmetric loadings, MPCs were employed across model boundaries and rigid format 24 was invoked. Nonsymmetric loadings required the use of the cyclic symmetry analysis available with rigid format 49. NASTRAN served as an important analysis tool in the Tokamak design effort by providing a reliable means for assessing structural integrity. Interactive graphics were employed in the finite element model generation and in the post-processing of results. It was felt that model generation and checkout with interactive graphics reduced the modelling effort and debugging man-hours significantly.
The vacuum isolation vessel and method in accordance with the present invention are used to accurately measure thermal noise in microphones. The apparatus and method could be used in a microphone calibration facility or any facility used for testing microphones. Thermal noise is measured to determine the minimum detectable sound pressure by the microphone. Conventional isolation apparatus and methods have been unable to provide an acoustically quiet and substantially vibration free environment for accurately measuring thermal noise. In the present invention, an isolation vessel assembly comprises a vacuum sealed outer vessel, a vacuum sealed inner vessel, and an interior suspension assembly coupled between the outer and inner vessels for suspending the inner vessel within the outer vessel. A noise measurement system records thermal noise data from the isolation vessel assembly. A vacuum system creates a vacuum between an internal surface of the outer vessel and an external surface of the inner vessel. The present invention thus provides an acoustically quiet environment due to the vacuum created between the inner and outer vessels and a substantially vibration free environment due to the suspension assembly suspending the inner vessel within the outer vessel. The thermal noise in the microphone, effectively isolated according to the invention, can be accurately measured.
NASA is currently developing Space Shuttle-based refilling of helium using superfluid helium on-orbit transfer (SHOOT). All the critical components of SHOOT need to be developed through ground-based tests. The helium dewar is one of these components. The Dewar consists of a vacuum vessel enclosing a superinsulated tank. The space between the vacuum vessel and the liquid tank is considered a common vacuum space. In the event that the vacuum is lost, the heat transfers to the dewar and the pressure inside the dewar increases rapidly, resulting in rupture of the dewar due to excessive pressure. Therefore, an emergency vent line is required for release of helium to prevent the dewar from rupturing. The study describes a numerical model for blow-down analysis in an emergency. This qualifies the design of the emergency vent line to be adequate for the assumed heat loads to the helium dewar.
Experimental investigations of the coupling of an electron beam into a magnetically confined plasma have been undertaken at the Marshall Space Flight Center using the Marshall Magnetic Mirror (M3) system. The M3 system is composed of the following: two magnet coils; a cylindrical vacuum vessel; microwave source; and electron beam source. The magnet coils, which form the magnetic mirror, have an inner diameter of 25.4 cm and an outer diameter of 50.8 cm. The coils are composed of 9 coil segments with 33 turns in each segment. Each coil segment is connected in series. To create the target plasma, a 2 kW microwave source (2.45 gHz) is coupled into the vacuum chamber via waveguide. The electron beam source is a hollow cathode device created by the EPL Corporation. The hollow cathode is capable of producing a 50 amp beam with a pulse length of 1 second. It is also capable of continuous operation at 5 amps. The hollow cathode is mounted on one end of the cylindrical vacuum vessel 24 cm outside of a magnet coil. A current sensor is placed in the hollow cathode keeper bias circuit to measure emission current.
Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.
A multielectrode device housed in an insulator vacuum vessel, the metal vapor vacuum switch has high power capability and can hold off voltages up to the 100 kilovolt level. Such switches can be electronically triggered and can interrupt or commutate at a zero current crossing. The physics of arc initiation, arc conduction, and interruption are examined, including material considerations; inefficiencies; arc modes; magnetic field effects; passive and forced extinction; and voltage recovery. Heating, electrode lifetime, device configuration, and external circuit configuration are discussed. The metal vapor vacuum switch is compared with SCRs, GTOs, spark gaps, ignitrons, and mechanical breakers.
Assembly of custom-shaped water-cooled chill bars developed for use during repair process in which cracks and pinholes in rocket-engine combustion chamber welded closed. Held in required relative geometric relationships by rigid framework, chill bars pressed against surface of chamber to conduct heat away from areas surrounding welds, preventing damage caused by overheating of areas not meant to be welded. Design features beneficial in other welding applications; for example, manufacture and repair of pressure vessels, chemical-processing vessels, and complexly shaped laboratory vacuum vessels.
Cryogenic vacuum insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Three areas of consideration are vital to achieve the optimum result: materials, representative test conditions, and engineering approach for the particular application. Deficiency in one of these three areas can prevent optimum performance and lead to severe inefficiency. Materials of interest include micro-fiberglass, multilayer insulation, and composite arrangements. Cylindrical liquid nitrogen boil-off calorimetry methods were used. The need for standard thermal conductivity data is addressed through baseline testing. Engineering analysis and design factors such as layer thickness, density, and practicality are also considered.
If the vacuum vessel that insulates a cryogenic dewar for a spaceborne experiment prior to launch is damaged, air will leak into the vacuum insulation space. As the sudden heat load causes the pressure to rise in the dewar, a safety disk in the emergency vent line will burst at the design pressure differential to allow vaporized cryogenic fluid to escape. The emergency vent line should be sized such that sufficient gaseous cryogen will be vented to keep the pressure inside the dewar below the design limit. On the other hand, the line should not be so large as to impose an unnecessary heat load on the dewar filled with cryogenic fluid. A vent-line computer program was generated to compute the maximum flow rate allowed for a proposed vent-line system. Parametric studies have been carried out for different burst disk pressure differentials, liquid cryogen ullage, and vent-line sizes.
Results are presented from a study of the coupling of an SP-100 nuclear reactor with either a Stirling or Brayton power system, at the 100 kWe level, for a power generating system suitable for operation in the lunar and Martian surface environments. In the lunar environment, the reactor and primary coolant loop would be contained in a guard vessel to protect from a loss of primary loop containment. For Mars, all refractory components, including the reactor, coolant, and power conversion components will be contained in a vacuum vessel for protection against the CO2 environment.
Passive levitation by superconducting magnetic bearings can be utilized in flywheels for energy storage. Basic design criteria of such a bearing are high levitation force, sufficient vertical and horizontal stability and low friction. A test facility was built for the measurement and evaluation of friction in a superconducting magnetic bearing as a function of operating temperature and pressure in the vacuum vessel. The bearing consists of a commercial disk shaped magnet levitated above single grain, melt-textured YBCO high-temperature superconductor material. The superconductor was conduction cooled by an integrated AEG tactical cryocooler. The temperature could be varied from 50 K to 80 K. The pressure in the vacuum chamber was varied from 1 bar to 10(exp -5) mbar. At the lowest pressure setting, the drag torque shows a linear frequency dependence over the entire range investigated (0 less than f less than 40 Hz). Magnetic friction, the frequency independent contribution, is very low. The frequency dependent drag torque is generated by molecular friction from molecule-surface collisions and by eddy currents. Given the specific geometry of the set-up and gas pressure, the molecular drag torque can be estimated. At a speed of 40 Hz, the coefficient of friction (drag-to-lift ratio) was measured to be mu = 1.6 x 10(exp -7) at 10(exp -5) mbar and T = 60 K. This is equivalent to a drag torque of 7.6 x 10(exp -10) Nm. Magnetic friction causes approx. 1% of the total losses. Molecular friction accounts for about 13% of the frequency dependent drag torque, the remaining 87% being due to eddy currents and losses from rotor unbalance. The specific energy loss is only 0.3% per hour.
Collapse of the current sheets in a plasma focus has been recorded simultaneously through slits parallel and perpendicular to the symmetry axis in the streak mode. The dark period following the collapse is due to the plasma moving out of the field of view. Microdensitometric measurements of intensity variation also support this conclusion. A large anisotropy is also found in the x-ray radiation pattern. Effects of different vacuum vessels were investigated.
The design of metal-vapor vacuum-arc switches (MVSs) for electromagnetic launchers is discussed, and preliminary results are presented for an experimental MVS. The general principles of triggered-vacuum-gap and vacuum-interrupter MVSs are reviewed, and the requirements of electromagnetic launchers are analyzed. High-current design problems such as electrode erosion, current sharing, magnetic effects, and thermal effects are examined. The experimental MVS employs stainless-steel flanges, a glass vacuum vessel, an adjustable electrode gap, autonomous internal magnetic-field coils, and a tungsten-pin trigger assembly. Some results from tests without magnetic augmentation are presented graphically.
The tokamak scrape-off (the region between the vacuum vessel wall and the magnetically confined fusion plasma edge), represents a source/sink for the hot fusion plasma. The electron densities and temperatures are in the ranges 10 to the 11th - 10 to the 13th/cu cm and 1-40 eV, respectively (depending on the size, magnetic field intensity and configuration, plasma current, etc). In the work reported, the electron temperature and density have been estimated in a Penning ionization discharge by comparing its spectroscopic emission in the VUV with that predicted by a collisional radiative model. An attempt to directly compare this emission with that of the tokamak edge is briefly described.
ASTROMAG, a particle astrophysics experimental facility proposed for running alongside a Space Station, has a large superconducting magnet to analyze particles coming from deep space. Several types of magnets were investigated for use in the ASTROMAG central facility. The factors which influence the selection of the magnet coil design include: (1) the upper limit of particle momentum resolved (proportional to the integrated field) as a function of solid angle; (2)cryogenic design and its effect on cryogen lifetime for a given central facility mass; and (3) the overall cost of the magnet coils and cryostat. Four magnet types are analyzed in this paper. These include a simple two-coil solenoid (the baseline design),two disk coils at the ends of the helium tank, a two-coil toroid and a thin solenoid plus bucking coil. A balance must be struck between cryostat lifetime, total mass and the integrated field through the detectors. This balance tends to favor coils which are in the same vacuum vessel as the cryogen.
The ESA Infrared Space Observatory (ISO) satellite is a 3 axes pointed platform designed to make accurate pointed observations of astronomical objects and sources in the wavelength range between 2.5 and 200 microns. ISO is composed of a service module and a payload module which is a large cylindrical vacuum vessel. The vessel is in fact a cryostat (capacity of 2250 l of liquid He II) which contains the telescope and the four focal scientific instruments. The latter being cooled up to a temperature less than 4 K. The qualification of the payload requires the measurement respectively of: the image quality of the telescope through wave front error (WFE) measurements; and the optical alignment of the scientific instruments with respect to the telescope axis and the telescope focus, and this under cryogenic conditions. Consequently, since 1988, the FOCAL 5 IAL Space facility has been upgraded in order to perform the cryogenic optical tests of the ISO optical subsystems.
A new plasma device, the Fisk Plasma Source (FPS), has been developed at Fisk University. This plasma device is used to study the physics of low temperature plasmas and plasma-material interactions. The FPS device is a stainless steel vacuum 6-way cross vacuum vessel with at 10-inch inner diameter. Low temperature argon plasmas are generated using DC glow discharge and thermionic filament techniques. Spatial profiles of the plasma density, plasma potential, and electron temperature are measured using Langmuir probes. We present initial experimental measurements of density and temperature profiles in the FPS device. Experimental and theoretical studies of low frequency oscillations observed in the FPS device are also presented.