Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration of waferscale voltage amplifier and electrostatic quadrupole focusing array for compact linear accelerators

Compact linear accelerators, with beam energies in the kiloelectron volt to megaelectron volt range, have applications in medicine, neutron/X-ray generation, surface modifications, etc. The size, weight, and power of existing accelerators preclude them from mass availability in portable formats. This paper presents a specific implementation of an ion accelerator architecture based on planar wafers with accelerating and focusing sections. Our low cost approach allows the control of the final ion beam energy with potential applications, for example, for accelerator-based ion implantation. In this paper, we demonstrate two important waferscale modules required to build a linear particle accelerator; these include (1) on-wafer voltage amplification for beam acceleration using Inductor-Capacitor (LC) resonators and (2) waferscale electrostatic quadrupole arrays (ESQA) to refocus the ion beams during transport. On-board LC resonators were developed using Printed Circuit Board fabrication processes to implement an LC element resonant at ~ 16.6 MHz with a quality factor of 25. An energy gain of ~ 250 eV was observed using a two wafer acceleration unit with an argon ion beam with 6.5 keV initial energy. A 3 × 3 ESQA was fabricated on a glass wafer with metal electrodes formed by depositing copper metal around the beam apertures. The ESQA was used to focus and defocus an argon ion beam, demonstrating a field gradient of ~ 500 V over a gap of ~ 250 μm.

43 PARTICLE ACCELERATORS↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

High temperature charge amplifier for geothermal applications

An amplifier circuit in a multi-chip module includes a charge to voltage converter circuit, a voltage amplifier a low pass filter and a voltage to current converter. The charge to voltage converter receives a signal representing an electrical charge and generates a voltage signal proportional to the input signal. The voltage amplifier receives the voltage signal from the charge to voltage converter, then amplifies the voltage signal by the gain factor to output an amplified voltage signal. The lowpass filter passes low frequency components of the amplified voltage signal and attenuates frequency components greater than a cutoff frequency. The voltage to current converter receives the output signal of the lowpass filter and converts the output signal to a current output signal; wherein an amplifier circuit output is selectable between the output signal of the lowpass filter and the current output signal.

15 GEOTHERMAL ENERGY↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier: Preprint

As inverter controls have become increasingly complex, power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves the desired inverter, a power amplifier, and a digital real-time simulator (DRTS) to control the simulated power system. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. The interface design for PHIL test beds has been previously examined in the literature, but many existing methods use older power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS rather than one preexisting in hardware. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and validated in hardware with a single 30-kW grid-following inverter.

DRTS↗

The CARIBU EBIS control and synchronization system

The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. The control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On filament structure and propagation within a commercial plasma globe

The filamentary discharge seen within commercial plasma globes is commonly enjoyed yet not well understood. Here, we investigate the discharge properties of a plasma globe using a variable high voltage amplifier. We find that increasing voltage magnitude increases the number of filaments while leaving their individual structure basically unchanged, a result typical of dielectric barrier discharges. The frequency of the voltage also affects filament population but more significantly changes filament structure, with more diffuse filaments seen at lower frequencies. Voltage polarity is observed to be important, especially at lower frequencies, where for negative-gradient voltages the discharge is more diffuse, not filamentary. At late stages of the discharge circular structures appear and expand on the glass boundaries. We find no trend of discharge speed with respect to voltage variables, though this may be due to manufacturer sample-to-sample variation. Each voltage cycle the discharge expands outward at ∼10–15 km/s, a speed significantly higher than the estimated electron drift yet considerably lower than that observed for most streamers. We discuss the physics of these observations and their relation to similar discharges that can be found within nature and industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microsystems-based method and apparatus for passive detection and processing of radio-frequency signals

A radio frequency (RF) receiver comprises a passive impedance transforming voltage amplifier and a resonant, latching micromechanical switch having a deflectable bridge, an RF actuation electrode receivingly connected to the amplifier, and a DC bias electrode positioned to latch the switch in a closed position by electrostatic attraction when energized by a suitable voltage. The bridge is configured with a mechanical mode of vibration that periodically urges the switch toward the closed position.

47 OTHER INSTRUMENTATION↗

Cross-correlation measurement of quantum shot noise using homemade transimpedance amplifiers

We report a cross-correlation measurement system, based on a new approach, which can be used to measure shot noise in a mesoscopic conductor at milliKelvin temperatures. In contrast to other measurement systems in which high-speed low-noise voltage amplifiers are commonly used, our system employs homemade transimpedance amplifiers (TAs). The low input impedance of the TAs significantly reduces the crosstalk caused by unavoidable parasitic capacitance between wires. The TAs are designed to have a flat gain over a frequency band from 2 kHz to 1 MHz. Low-noise performance is attained by installing the TAs at a 4 K stage of a dilution refrigerator. Our system thus fulfills the technical requirements for cross-correlation measurements: low noise floor, high frequency band, and negligible crosstalk between two signal lines. Using our system, shot noise generated at a quantum point contact embedded in a quantum Hall system is measured. The good agreement between the obtained shot-noise data and theoretical predictions demonstrates the accuracy of the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applicability of micro-channel plate followed by phosphor screen to charged particles

This paper experimentally investigates the applicability of a micro-channel plate (MCP) followed by a phosphor screen to charged particles along with a calibration method for estimating the acceptable limit of input particle flux and appropriate operation parameters of a particular MCP. For the first time, plasmas consisting of only lithium ions are injected into the MCP. Despite large ion numbers (N{sub i}) on the order of ≃10{sup 7}, no deterioration in the effective gain (αG) of the MCP owing to an excess amount of the extracted charge occurs in a certain range of the amplifier voltage (ΔU{sub M}) applied to the MCP. The measured αG nearly agrees with the expected value. However, once ΔU{sub M} exceeds a limit value, αG eventually begins to saturate. This is also verified in experiments using pure electron plasmas. An appropriate range of ΔU{sub M} is presented to avoid saturation and, finally, derive N{sub i} directly from the secondary electron current outputted from the MCP only after the indispensable calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of Large-Volume High-Pressure Plasma by Spatio-Temporal Control of Space Charge

Due to the fundamental limitations of scaling, very little progress has been made towards achieving a large-volume dense non-equilibrium plasma near atmospheric pressures. Commercially available state-of-the art glow-like atmospheric plasma devices for industrial applications are either narrow tubes or wide slits with narrow openings. Often multiple sources are put together in various configurations to process larger surfaces. The traditional methods of exciting electrodes create spatially fixed electric fields. As a result, the space charge at atmospheric pressure tends to be spatially confined resulting in non-uniformity which eventually leads to instability as the discharge is scaled. Theoretical work done under this project showed that it is possible to generate a spatially rotating electric field by exciting a set of electrodes with phase staggered sinusoidal waveforms. The modeling and simulations were done using plasma fluid models. It was shown that such a field can produce a uniform plasma. At the conclusion of the project, experimental proof of concept with an eight-electrode system in various gases (Air, Helium and Argon) was demonstrated. Power measurements and spectral investigation show that the concept can be used to generate a uniform stable plasma. This plasma source has the potential of opening new applications of nonthermal plasma including combustion of carbon-free fuel. The current limitation of the proposed method in scaling to higher volume and pressure is the need for multiple high voltage amplifiers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector Performance on Surface Passivation and its Long-Term Stability

Surface passivation is an ideal technique to prepare the surfaces of fabrication Cadmium Zinc Telluride (CZT) and related semiconductor devices such as Cadmium Zinc Tellurium Selenide (CZTS). Surface passivation techniques reduce the effects of aging in the detector [1]. Surface performance effects on material performance can result in fluctuations in energy resolution over time (such as periods of a year or more). The long-term stability of surface passivation with Potassium Hydroxide (KOH) was observed with measurement of 1) current (nano Amp) vs voltage (V) and 2) spectral response and energy resolution throughout the years. Three CZTS detector samples of M2, M3, and M4 were examined using a photomultiplier tube and voltage amplifier. The Bridgman technique is used to grow the CZTS used in this study.

Johnson, Kirsten [Morgan State Univ., Baltimore, M↗

Frequency stabilization in nonlinear MEMS and NEMS oscillators

An illustrative system includes an amplifier operably connected to a phase shifter. The amplifier is configured to amplify a voltage from an oscillator. The phase shifter is operably connected to a driving amplitude control, wherein the phase shifter is configured to phase shift the amplified voltage and is configured to set an amplitude of the phase shifted voltage. The oscillator is operably connected to the driving amplitude control. The phase shifted voltage drives the oscillator. The oscillator is at an internal resonance condition, based at least on the amplitude of the phase shifted voltage, that stabilizes frequency oscillations in the oscillator.

42 ENGINEERING↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

New Results from the Search for Low-Mass Weakly Interacting Massive Particles with the CDMS low ionization Threshold Experiment

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite.

New Results, Low-Mass, Mazzive Particles, CDMS Low↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

42 ENGINEERING↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

Nguyen, Dinh Cong↗