Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIDEO EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Test for the Existence of Mach Effects with a Rotary Device

Owing to the variation in the results of several experiments designed to produce thrust with devices employing Mach effects, it was decided to design an experiment with the simple purpose of determining whether or not Mach effects actually exist, and if they can be produced when the ''bulk'' acceleration and internal energy changes required to produce them are separately supplied. In the experiment arrays of eight 500 pf high voltage capacitors are mounted on the end of a rotor and spun to and from speeds of about 60 Hz (3600 rpm) while they are excited with a 40 KHz voltage signal with amplitudes up to 6 KV. The capacitors are sandwiched between two accelerometers and any Mach effect mass fluctuation is detected as a weight fluctuation that produces signals in the accelerometers that are antiphase. Those signals are subtracted with a differential instrumentation amplifier that suppresses other signals as common mode noise. Signals with the properties sought have been found and recorded with video equipment. They suggest that Mach effects are real, and that the bulk accelerations and internal energy changes that produce them can in fact be separately supplied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control Center Viewing of UAS-Based Real-Time Sensor and Video Measurements at an Electric Utility Facility

Drones equipped with video cameras, LIDAR and thermal imagers have been demonstrated in industrial and utility settings. In such instances, the images are typically locally stored onboard the drone then retrieved from the image storage media and analyzed. We report on a project involving the transport and display of measurements and thermal and visual video streams into a utility control center. Relying on an integrated multimedia communications network, realtime control center viewing of sensor readings and image streams is achieved. Details of this activity are reported.

42 ENGINEERING↗

Analog Video Authentication and Seal Verification Equipment Development

Under contract to the US Department of Energy in support of arms control treaty verification activities, the Savannah River National Laboratory in conjunction with the Pacific Northwest National Laboratory, the Idaho National Laboratory and Milagro Consulting, LLC developed equipment for use within a chain of custody regime. This paper discussed two specific devices, the Authentication Through the Lens (ATL) analog video authentication system and a photographic multi-seal reader. Both of these devices have been demonstrated in a field trial, and the experience gained throughout will also be discussed. Typically, cryptographic methods are used to prove the authenticity of digital images and video used in arms control chain of custody applications. However, in some applications analog cameras are used. Since cryptographic authentication methods will not work on analog video streams, a simple method of authenticating analog video was developed and tested. A photographic multi-seal reader was developed to image different types of visual unique identifiers for use in chain of custody and authentication activities. This seal reader is unique in its ability to image various types of seals including the Cobra Seal, Reflective Particle Tags, and adhesive seals. Flicker comparison is used to compare before and after images collected with the seal reader in order to detect tampering and verify the integrity of the seal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Robotic Crane System for the Deconstruction of Chernobyl Unit 4 - 18583

The Chernobyl Nuclear Power Plant (ChNPP) Unit 4 accident occurred on April 26, 1986 leaving a severely damaged reactor building and a highly radioactive area. To minimize the long-term radiological impact to personnel and the environment, Unit 4 was immediately enclosed by a structure named the Object Shelter (OS). To transform the OS into an ecologically safe system, the Shelter Implementation Plan (SIP) was developed in 1997. The most significant SIP tasks was the design and construction of the New Safe Confinement (NSC). The NSC is a 36,000 tonne arch enclosure that includes a suite of process equipment to address the ruins of Unit 4 while assuring the safety of workers, public, and the environment. The NSC has a span of 257 meters, length of 164 meters, and height of 110 meters and is designed for a 100 years life. The New Safe Confinement was slid from its erection area to directly over Unit 4 (a distance of 327 meters) in November 2016. One of the major mechanical handling systems installed in the NSC is the Main Cranes System (MCS), designed and fabricated by PaR Systems (USA). The planned deconstruction activities require the handling of shielded waste disposal casks containing fuel as well as transporting extremely large structural elements -remotely controlled using video surveillance equipment. The lifting activities required the cranes to be tele-robotically controlled to prevent inadvertent collisions, expedite repetitive and high accuracy functions, protect the equipment and structures within the NSC as well as increase the overall effectiveness of the MCS. In addition, due to the elevated radiation levels, remote deconstruction activities will need to be performed. The MCS has design provisions included for a tele-robotically controlled manipulator and a suite of tooling to be used for multiple activities including concrete coring, cutting, debris collection and other heavy demolition activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spontaneous oscillation of the ciliary beat frequency regulated by release of Ca2+ from intracellular stores in mouse nasal epithelia

Highlights: • Spontaneous CBF oscillation was found in ciliated mouse nasal epithelial cells. • The CBF oscillation was caused by the [Ca{sup 2+}]i oscillation. • The [Ca{sup 2+}]i oscillations were generated by the periodic Ca{sup 2+} release from internal stores via interactions between IP{sub 3} and IP{sub 3} receptor. • The CBF oscillation may play a crucial role for maintaining an efficient mucociliary clearance in nasal epithelia. Ciliary beating frequency (CBF) was investigated in ciliated nasal epithelial cells (cMNECs) isolated from mice using video microscopy equipped with a high-speed camera. In cMNECs, a spontaneous CBF oscillation was observed. The CBF oscillation was abolished by BAPTA-AM but not by Ca{sup 2+}-free solution. The addition of thapsigargin, which depletes Ca{sup 2+} from internal stores, also abolished CBF oscillation. Moreover, the intracellular Ca{sup 2+} concentration [Ca{sup 2+}]{sub i}, spontaneously oscillated even with the Ca{sup 2+}-free solution. Moreover, 2APB (an inhibitor of the IP{sub 3} receptor) abolished CBF oscillation in cMNECs. Overall, these findings suggest that the CBF oscillation in cMNECs is triggered by the release of Ca{sup 2+} from the IP{sub 3}-sensitive internal stores. Moreover, IBMX, an inhibitor of phosphodiesterase, did not affect CBF oscillation in cMNECs, although it slightly increased CBF. These results suggest that CBF oscillations were induced by [Ca{sup 2+}]{sub i} oscillation controlled via the release of Ca{sup 2+} from IP{sub 3}-sensitive stores, rather than via cAMP accumulation. CBF oscillation possibly plays a crucial role in maintaining an efficient mucociliary clearance in the nasal epithelia.

60 APPLIED LIFE SCIENCES↗

SU-E-T-619: Planning 131I Thyroid Treatments for Patients Requiring Hemodialysis

Purpose: Treatment of 131I thyroid cancer patients who also require regular hemodialysis (HD) treatments requires consideration of the administered activity and the HD schedule. In this work the red bone marrow is considered the dose limiting organ and the treatment plan optimized the HD schedule with the amount of radioactivity administered. Methods: The ‘Safe’ dose was considered to be 2 Gy (200 rad) to the red bone marrow.1 131Iodine doses of 50 mCi to 100 mCi were modeled and found to require a range of HD schedules. In order to achieve the safe dose to the red marrow, more aggressive HD schedules are required. 100 mCi required an aggressive HD treatment of every 24 hours for at least one week to achieve the ‘safe’ dose and an exposure appropriate for release from the hospital. A more normal schedule of HD beginning at 18 hours then every 48 hours allowed for up to 60 mCi administered dose allowed for a safe dose and expected release after less than one week.2In addition room was equipped with video cameras cameras for monitoring the patient and their vital signs from an adjacent room during HD. In this way the dialysis nurses were able to monitor the patient closely from an adjoining room. Results: Two HD patients were administered adjusted doses of about 50 mCi. The medical and nursing staff were exposed to no more than 4 mR for the entire treatment. The residual Iodine in the patient appeared to be normal after 4 to 6 days when the patient was released. Conclusion: With careful treatment planning 131Iodine treatments can be performed safely for patients needing HD and treatments appear to be as effective as those for patients with normal renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of neutron radiation damage and shielding for operational good practice of the video systems at Jet - 25426

High neutron and gamma ray yields in fusion reactors like JET can be detrimental to the applied diagnostic equipment such as video imaging systems. For instance, defects induced in semiconductors by neutrons via displacement damage effects degrade the performance of CCD image sensors. Actions to minimize and/or mitigate these effects need to be considered during operation and maintenance of the video system at JET. A preliminary study on the setting up of a neutron/gamma shield around the cameras has been pursued. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring critical facilities by using advanced RF devices

The ability to monitor critical environment parameters of nuclear plants at all times, particularly during and after a disruptive accident, is vital for the safety of plant personnel, rescue and recovery crews, and the surrounding communities. Conventional hard-wired assets that depend on supplied power may be decimated as a result of such events, as witnessed in the Japanese Fukushima nuclear power plant in March 2011. Self-powered monitoring devices operating on a wireless platform, on the other hand, may survive such calamity and remain functional. The devices would be pre-positioned at strategic locations, particularly where the dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance. Equipped with sensors for β-γ radiation, neutrons, hydrogen gas, temperature, humidity, pressure, and water level, as well as with criticality alarms and imaging equipment for heat, video, and other capabilities, these devices can provide vital surveillance information for assessing the extent of plant damage, mandating responses (e.g., evacuation before impending hydrogen explosion), and enabling overall safe and efficient recovery in a disaster. A radio frequency identification (RFID)-based system - called ARG-US - may be modified and adapted for this task. Developed by Argonne for DOE, ARG-US (meaning 'watchful guardian') has been used successfully to monitor and track sensitive nuclear materials packages at DOE sites. It utilizes sensors in the tags to continuously monitor the state of health of the packaging and promptly disseminates alarms to authorized users when any of the preset sensor thresholds is violated. By adding plant-specific monitoring sensors to the already strong sensor suite and adopting modular hardware, firmware, and software subsystems that are tailored for specific subsystems of a plant, a Remote Area Modular Monitoring (RAMM) system, built on a wireless sensor network (WSN) platform, is being developed by Argonne National Laboratory. ARG-US RAMM, powered by on-board battery, can sustain extended autonomous surveillance operation during and following an incident. The benefits could be invaluable to such critical facilities as nuclear power plants, research and test reactors, fuel cycle manufacturing centers, spent-fuel dry-cask storage facilities, and other nuclear installations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Image mosaicing for automated pipe scanning

Remote visual inspection (RVI) is critical for the inspection of the interior condition of pipelines particularly in the nuclear and oil and gas industries. Conventional RVI equipment produces a video which is analysed online by a trained inspector employing expert knowledge. Due to the potentially disorientating nature of the footage, this is a time intensive and difficult activity. In this paper a new probe for such visual inspections is presented. The device employs a catadioptric lens coupled with feature based structure from motion to create a 3D model of the interior surface of a pipeline. Reliance upon the availability of image features is mitigated through orientation and distance estimates from an inertial measurement unit and encoder respectively. Such a model affords a global view of the data thus permitting a greater appreciation of the nature and extent of defects. Furthermore, the technique estimates the 3D position and orientation of the probe thus providing information to direct remedial action. Results are presented for both synthetic and real pipe sections. The former enables the accuracy of the generated model to be assessed while the latter demonstrates the efficacy of the technique in a practice.

42 ENGINEERING↗

Experimental and Computational Study of a High-Speed Collision of an Aluminum Striker with a Solid and Mesh Obstacle

The results of computational and experimental studies of peculiarities of the process of impact between the striker and obstacle, which imitates shield protection of spacecrafts, have been considered and pictures of fragmentation of the striker and obstacle have been obtained. The numerical calculations were carried out using the method of smooth particle hydrodynamics (SPH). In the experiments, the striker was accelerated using a two-stage light-gas gun; the state of the obstacle and striker at the moment of their interaction was controlled using an X-ray and high-speed video camera. The recording equipment was switched on using induction cross sections. The comparative analysis of the results of numerical simulations and experiments have been considered.

42 ENGINEERING↗

Critical Skills at SRS: Mechanical Engineer

Monica Phillips discuss her role as an engineer at Savannah River National Laboratory. Her mission is to provide support to various customers on-site through engineered equipment and solutions, along with solving complex problems to help them meet their needs.

42 ENGINEERING↗

WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.

60 APPLIED LIFE SCIENCES↗

Video Camera Improvements to Support Hanford Tank Farms - 17141

Hanford Tank Farms consist of 177 underground storage tanks that contain 56 million gallons of radioactive waste. The current mission is to safely manage this waste in preparation to feed the Waste Treatment Plant. Fulfilling this mission includes inspecting each tank regularly to ensure tank integrity and support ongoing operations such as transferring waste from older single-shell tanks to the newer double-shell tanks. Video cameras derived from commercially available equipment have provided the ability to remotely see inside the tanks, reducing some of the challenges of fulfilling this mission. However, there are many challenges and limitations with the currently used video systems. Among some of the challenges are limited tank interior entry points for camera deployment, high radiation dose rates, limited equipment longevity in the environmental conditions, need for high resolution image quality, low light conditions, and in-tank obstructions. Washington River Protection Solutions (WRPS) has identified and tested new video systems that will effectively manage these challenges and increase capability, efficiency, and improve safety. The new camera systems are planned for deployment to support the next Single Shell Tank Retrieval Project in the A/AX tank Farm complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

NETL's JIC in a box

The National Energy Technology Laboratory developed the idea of a portable joint information center AKA JIC in-a-box. This video discribes some of the equipment in the portable JIC as well as some of the methodology that NETL developed as a result of this portable JIC concept.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is planned to create fully equipped complex facility possible to perform various experiments on the intensive neutron beam. Epithermal neutron beam enables development across the full spectrum of materials research for example shielding concrete tests or electronic devices construction improvement. Due to recent reports on the construction of the accelerator for the Boron Neutron Capture Therapy (BNCT) it has the opportunity to become useful and successful method in the fight against brain and other types of cancers not treated with well known medical methods. In Europe there is no such epithermal neutron source which could be used throughout the year for training and research for scientist working on BNCT what makes the stand unique in Europe. Also our research group which specializes in mixed radiation dosimetry around nuclear and medical facilities would be able to carry out research on new detectors and methods of measurements for radiological protection and in-beam (therapeutic) dosimetry. Another group of scientists from National Centre for Nuclear Research, where MARIA research reactor is located, is involved in research of gamma detector systems. There is an idea to develop Prompt-gamma Single Photon Emission Computed Tomography (Pg- SPECT). This method could be used as imaging system for compounds emitting gamma rays after nuclear reaction with thermal neutrons e.g. for boron concentration in BNCT. Inside the room, where H2 channel is located, there is another horizontal channel - H1 which is also unused. Simultaneously with the construction of the H2 stand it will be possible to create special pneumatic horizontal mail inside the H1 channel for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. It might expand the scope of research at the planned neutron station. Secondly it is planned to equip both stands with moveable positioning system, video system and facilities to perform animal experiments (anaesthesia, vital signs control, imaging devices, positioning). These all above make constructed station unique in the world (uranium fission converter-based beam) and the only one of such intense neutron beam in the Europe. Moreover implementation of the station would allow the development of research on a number of issues for researchers from all over the Europe. One of very important advantages of the station is undisturbed exploitation of the reactor and other vertical and horizontal channels. MARIA reactor operates 6000 hours per year and that amount of time will be achievable for research on the neutron station. It have to be underlined that new neutron station will work parallel to all another ventures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗