Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VERTICAL AXIS TURBINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Near-wake dynamics of a vertical-axis turbine

Cross-flow, or vertical-axis, turbines are a promising technology for capturing kinetic energy in wind or flowing water and their inherently unsteady fluid mechanics present unique opportunities for control optimization of individual rotors or arrays. To explore the potential for beneficial interactions between turbines in an array, as well as to characterize important cycle-to-cycle variations, coherent structures in the wake of a single two-bladed cross-flow turbine are examined using planar stereo particle image velocimetry in a water channel experiment. There are three main objectives in the present work. First, the mean wake structure of this high chord-to-radius ratio rotor is described, compared with previous studies, and a simple explanation for observed wake deflection is presented. Second, the unsteady flow is then analysed via the triple decomposition, with the periodic component extracted using a combination of traditional techniques and a novel implementation of the optimized dynamic mode decomposition. The latter method is shown to outperform conditional averaging and Fourier methods, as well as uncover frequencies suggesting a transition to bluff-body shedding in the far wake. Third, vorticity and finite-time Lyapunov exponents are then employed to further analyse the oscillatory wake component. Vortex streets on both sides of the wake are identified, and their formation mechanisms and effects on the mean flow are discussed. Strong axial (vertical) flow is observed in vortical structures shed on the retreating side of the rotor where the blades travel downstream. Time-resolved tracking of these vortices is performed, which demonstrates that vortex trajectories have significant rotation-to-rotation variation within one diameter downstream. This variability suggests it would be challenging to harness or avoid such structures at greater downstream distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RITE Gen5 KHPS Levelized Cost of Energy

Levelized Cost of Energy analysis for Verdant Power Gen5 KHPS utilizing annualized AEP based on actual energy generation at the RITE Project during 2020-21. The WEC devices analyzed include attenuator, point absorber, oscillating wave surge converter, oscillating water column, overtopping/terminator device, submerged pressure differential, bulge wave, and rotating mass type wave energy converter devices. The CEC devices analyzed include horizontal axis turbine, vertical axis turbine, oscillating hydrofoil, enclosed tips (Venturi), Archimedes screw, and tidal kite type current energy converter devices.

16 TIDAL AND WAVE POWER↗

Conceptual Design of a Tension Leg Platform With 22.3 MW Vertical Axis Turbine

Here, this paper presents the conceptual design of a tension leg platform (TLP) for the ARCUS “towerless” vertical-axis wind turbine (VAWT). VAWTs are ideal for floating offshore sites and have several advantages over horizontal-axis wind turbines (HAWT) including reduced top mass, lower center of gravity, increased energy capture, and in turn lower cost. The towerless ARCUS VAWT drives these advantages further through increased structural efficiency and by enabling more optimized TLP designs with simplified installation procedures. For hull sizing, we have studied three turbine sizes with corresponding power ratings of 5.1 MW, 10.4 MW and 22.3 MW. The largest turbine was identified as having the greatest potential to reduce the levelized cost of energy (LCOE) and is the reference size used for the further detailed design process. The conceptual design of the VAWT TLP has been awarded with an ABS Approval in Principle Certificate. This paper contains brief analysis results and design findings for a TLP designed to house a VAWT, including the following topics: • Applicable Design Codes • Metocean Conditions • ARCUS Turbine Loads • Design Load Cases and Requirements - Pre-service TLP Stability - In-place TLP Global Performance • Platform Configurations, Hull Structure Scantling Design, Weight and CG Estimation, and General Arrangement Drawings • Hull Ballast Plan for both Pre-service and In-place Conditions • Pre-service Quayside Integration, Transportation and Wet Tow Stability Analysis • Global Performance Analysis for Motions and Tendon tensions • Summary of cost components and system levelized cost of energy

17 WIND ENERGY↗

Aeroelastic Validation of the Sandia Offshore Wind Energy Simulator (OWENS) for Vertical-Axis Wind Turbines

Vertical-axis wind turbines (VAWTs) have been the subject of research and development for nearly a century. However, this turbine architecture has fallen in and out of favor on multiple occasions. Beginning in the late 1970s, the U.S. Department of Energy sponsored an extensive experimental program through Sandia National Laboratories which produced a mass of experimental data from several highly instrumented turbines. Turbines designed, built, and tested include the 2 meter, 5 meter, 17 meter, and 34 meter and their respective configurations. This program kicked off a commercial collaboration and resulted in the FloWind turbines. The FloWind turbines had several notable design changes from the experimental turbines that, in conjunction with a general lack of understanding regarding predicting fatigue at the time, led to the majority of the turbines failing prematurely during the late 80s.

17 WIND ENERGY↗

Vertical axis wind turbine airfoil

A vertical axis wind turbine airfoil is described. The wind turbine airfoil can include a leading edge, a trailing edge, an upper curved surface, a lower curved surface, and a centerline running between the upper surface and the lower surface and from the leading edge to the trailing edge. The airfoil can be configured so that the distance between the centerline and the upper surface is the same as the distance between the centerline and the lower surface at all points along the length of the airfoil. A plurality of such airfoils can be included in a vertical axis wind turbine. These airfoils can be vertically disposed and can rotate about a vertical axis.

Krivcov, Vladimir↗

Modal dynamics and flutter analysis of floating offshore vertical axis wind turbines

Floating platforms provide vertical axis wind turbines (VAWTs) significant advantages over offshore horizontal axis wind turbines, which has led to increased research interest in offshore VAWT technology. Here, this paper examines dynamic stability of floating VAWTs and presents structural dynamic and aero-elastic flutter analysis of utility-scale 5 MW floating VAWTs by coupling a rotor finite element model with a linearized model for the floating system. The coupled floating VAWT model is utilized to study the effects of tower height, number of blades, blade tapering scheme, and impacts of the floating platform on modal properties and flutter. The study provides important new results and guidance to floating VAWT designers: (1) tower height increase leads to lower tower frequencies more prone to resonance, (2) by moving from land-based foundations to a floating TLP foundation, tower-mode frequency is increased significantly (by 49%–68%) which mitigates resonance and increases the flutter RPM (154% increase), (3) increasing the number of blades reduces the tower mode frequencies for both land-based and floating configuration, and (4) blade chord tapering can have a significant impact on increasing the tower mode flutter RPM. Further, analysis of low-frequency rigid body modes shows a safe, higher flutter RPM relative to the operating RPM.

17 WIND ENERGY↗

Critical design load case fatigue and ultimate failure simulation for a 10-m H-type vertical-axis wind turbine

While previous studies investigating critical VAWT design load cases have focused on large and relatively flexible Darrieus designs, the bulk of current commercial products seeking certification fall in the relatively small, stiff, and H-type configuration, such as the XFlow Energy Corporation turbine that this study compares against. Understanding the critical design load case impacts for both fatigue and ultimate failure for this size and type of VAWT are imperative for certification. The abil

Brownstein, Ian↗

Intracycle RPM control for vertical axis wind turbines

The wind energy market is currently dominated by horizontal axis wind turbines (HAWTs); however, vertical axis wind turbines (VAWTs) are emerging as a design alternative, especially for deep-water offshore siting due to their low center of gravity, ease of access to drivetrain components, and overall simplicity. Due to the absence of a pitch mechanism in large-scale Darrieus VAWTs, stall control has often been used to manage power and loads. Introducing a pitching mechanism in H-type VAWTs has been studied, but this diminishes the mechanical simplicity advantage, and the use of a pitching mechanism in a large-scale Darrieus-type VAWT is not practical. This work examines an innovative, alternative method to control the rotor dynamics of a large-scale 5 MW VAWT to maximize power while constraining loads without introducing any new or complex mechanical elements. This control strategy is termed intracycle revolution per minute (RPM) control, where the rotational speed of the turbine is allowed to vary in an optimal fashion with the azimuthal location of blades as opposed to typical constant RPM operation. An optimization framework is formulated for an open-loop optimal control problem and solved to maximize power subject to constraints on aerodynamic design loads. Results are presented to demonstrate the benefits and the performance limits of intracycle RPM control for large-scale 5 MW Darrieus VAWTs, namely, (1) power production (quantified in terms of AEP) that can be increased subject to baseline load limits and (2) opportunities to significantly increase AEP or decrease loads via intracycle RPM control that are examined for both two-bladed and three-bladed VAWTs.

17 WIND ENERGY↗

A semi-coupled aero-servo-hydro numerical model for floating vertical axis wind turbines operating on TLPs

Floating vertical axis wind turbines (VAWTs) have many advantages over floating horizontal axis wind turbines (HAWTs) at large scales in deep water; however, there are several key challenges to overcome as well. One of the challenges is accurate prediction of the dynamic motion and loads performance of a floating VAWT. Here, a new semi-coupled aero-servo-hydro method is developed to assess dynamic responses of a floating VAWT by modeling the system as a 7-degree-of-freedom (7-DOF) model: the supporting platform is considered as a 6-DOF rigid body; the rotation of the rotor is considered as the 7th DOF. Aerodynamic, hydrodynamic, and mooring loads and control of the rotor speed are fully considered. This model can predict performance of floating VAWTs with reasonable fidelity according to validation with OrcaFlex through static and dynamic responses of a floating VAWT with Darrieus rotor operating on a new tension-leg platform (TLP). Being a reduced complexity model, the 7-DOF model can be efficiently applied to assess performance of the newly designed floating VAWT. This model is used to examine the relative contributions of aerodynamic and wave loads imparted to the floating system and the benefits of a three-bladed VAWT over a two-bladed VAWT through dynamic and fatigue analysis.

17 WIND ENERGY↗

Aeroelastically coupled blades for vertical axis wind turbines

Various technologies described herein pertain to a vertical axis wind turbine blade configured to rotate about a rotation axis. The vertical axis wind turbine blade includes at least an attachment segment, a rear swept segment, and optionally, a forward swept segment. The attachment segment is contiguous with the forward swept segment, and the forward swept segment is contiguous with the rear swept segment. The attachment segment includes a first portion of a centroid axis, the forward swept segment includes a second portion of the centroid axis, and the rear swept segment includes a third portion of the centroid axis. The second portion of the centroid axis is angularly displaced ahead of the first portion of the centroid axis and the third portion of the centroid axis is angularly displaced behind the first portion of the centroid axis in the direction of rotation about the rotation axis.

17 WIND ENERGY↗

Vertical-Axis Wind Turbine Steady and Unsteady Aerodynamics for Curved Deforming Blades

Vertical-axis wind turbines’ simpler design and low center of gravity make them ideal for floating wind applications. However, efficient design optimization of floating systems requires fast and accurate models. Low-fidelity vertical-axis turbine aerodynamic models, including double multiple streamtube and actuator cylinder theory, were created during the 1980s. Commercial development of vertical-axis turbines all but ceased in the 1990s until around 2010 when interest resurged for floating applications. Despite the age of these models, the original assumptions (2-D, rigid, steady, straight bladed) have not been revisited in full. When the current low-fidelity formulations are applied to modern turbines in the unsteady domain, aerodynamic load errors nearing 50% are found, consistent with prior literature. However, a set of steady and unsteady modifications that remove the majority of error is identified, limiting it near 5%. This paper shows how to reformulate the steady models to allow for unsteady inputs including turbulence, deforming blades, and variable rotational speed. A new unsteady approximation that increases numerical speed by 5–10× is also presented. Combined, these modifications enable full-turbine unsteady simulations with accuracy comparable to higher-fidelity vortex methods, but over 5000× faster.

17 WIND ENERGY↗

Towerless vertical-axis wind turbine

The present disclosure is directed to towerless vertical-axis wind turbines with pre-tensioned rotors. The present disclosure is further directed to a vertical-axis wind turbine (VAWT) with supported blade ends (e.g., Darrieus type) which replaces the center tower with tensioned supports, such as tensioned guy wires, and blade pre-load.

17 WIND ENERGY↗

High-efficiency wind turbine

Vertical axis wind turbine incorporates several unique features to extract more energy from wind increasing efficiency 20% over conventional propeller driven units. System also features devices that utilize solar energy or chimney effluents during periods of no wind.

Hein, L. A.↗

System Levelized Cost of Energy Analysis for Floating Offshore Vertical-Axis Wind Turbines

The levelized cost of energy for an offshore wind plant consisting of floating vertical-axis wind turbines is studied in this report. A 5 MW Darrieus vertical-axis wind turbine rotor is used as the study turbine as this architecture was determined to have the greatest ability to reduce the system cost. The rotor structural design was used with blade manufacturing cost model studies to estimate its cost. A two-bladed, carbon fiber rotor was selected in this analysis since the lower topside mass resulted in a reduction of the platform costs which exceeded the increased rotor cost. A direct-drive, medium efficiency drivetrain was designed which represents 25% of the costs and 45% of the mass of the combined rotor/drivetrain system. A direct-drive, permanent magnet generator drivetrain was selected due to the improved reliability of this type of system, while the cost was not significantly higher than for geared drivetrains. A platform was designed by first identifying the optimal architecture for the vertical-axis wind turbine at a water depth of 150 m. A survey was performed of floating platform types, and six characteristic designs were analyzed which span the range of stability mechanisms available to floating systems. A multi-cellular tension-leg platform was identified as the lowest cost platform which additionally provided some interesting performance benefits. The small motions of the tension-leg platform benefit the system energy capture while limiting inertial loads placed on the rotor’s tower and blades. A final design was produced for the multi-cellular tension-leg platform considering operational fatigue, storm wind and wave conditions, and tow-out design cases. The driving design load was stability during tow-out while ballasting the platform. System levelized cost of energy was calculated, including operational expenses and balance of system costs estimated for the wind plant. Opportunities for reduction in the component costs are predicted and used to make projections of the system levelized cost of energy for future developments. The opportunities and challenges for floating vertical-axis wind turbines are identified by the system design and levelized cost of energy analysis.

17 WIND ENERGY↗