Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VERTEBRAE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

60 APPLIED LIFE SCIENCES↗

Micro-CT Imaging of Rat Bone and Lumber Vertebra using Synchrotron Radiation

Micro-tomographic imaging with a spatial resolution on the micrometer scale offers owes a high potential to perform certain types of measurements that were not feasible with other techniques or conventional laboratory methods. The synchrotron X-ray source gives substantial advantages because of its high brilliance and continuous X-ray spectrum. Based on this, visualized the microstructure of rat bone and lumber vertebra was visualized using 20, 25 and 30 keV synchrotron X-rays. We utilized the data which was acquired at different energies for multi-model imaging and to estimate the Ca/P ratio. Up to now there has been no research carried out using these images for the estimation of the calcium content, with synchrotron X-rays. The results are based on the analysis of images and gray values obtained at different energies. We introduce this new method in order to measure the calcium content by means of high resolution synchrotron micro-CT.

60 APPLIED LIFE SCIENCES↗

Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Range Uncertainty Due to Bone Cement Injected Into the Vertebra in Radiation Therapy Planning

We wanted to evaluate the influence of bone cement on the proton range and to derive a conversion factor predicting the range shift by correcting distorted computed tomography (CT) data as a reference to determine whether the correction is needed. Two CT datasets were obtained with and without a bone cement disk placed in a water phantom. Treatment planning was performed on a set of uncorrected CT images with the bone cement disk, and the verification plan was applied to the same set of CT images with an effective CT number for the bone cement disk. The effective CT number was determined by measuring the actual proton range with the bone cement disk. The effects of CT number, thicknesses, and position of bone cement on the proton range were evaluated in the treatment planning system (TPS) to draw a conversion factor predicting the range shift by correcting the CT number of bone cement. The effective CT number of bone cement was 260 Hounsfield units (HU). The calculated proton range for native CT data was significantly shorter than the measured proton range. However, the calculated range for the corrected CT data with the effective CT number coincided exactly with the measured range. The conversion factor was 209.6 [HU . cm/mm] for bone cement and predicted the range shift by approximately correcting the CT number. We found that the heterogeneity of bone cement could cause incorrect proton ranges in treatment plans using CT images. With an effective CT number of bone cement derived from the proton range and relative stopping power, a more actual proton range could be calculated in the TPS. The conversion factor could predict the necessity for CT data correction with sufficient accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Vertebral Body Growth After Craniospinal Irradiation

Purpose: To estimate the effects of radiotherapy and clinical factors on vertebral growth in patients with medulloblastoma and supratentorial primitive neuroectodermal tumors treated with craniospinal irradiation (CSI) and chemotherapy. Methods and Materials: The height of eight individual or grouped vertebral bodies (C3, C3-C4, T4, T4-T5, C6-T3, T4-T7, L3, L1-L5) was measured before and after CSI (23.4 or 36-39.6 Gy) in 61 patients. Of the 61 patients, 40 were boys and 21 were girls (median age, 7 years; range, 3-13 years), treated between October 1996 and October 2003. Sagittal T{sub 1}-weighted magnetic resonance images were used for the craniocaudal measurements. The measurements numbered 275 (median, 5/patient; range, 3-7). The median follow-up after CSI was 44.1 months (range, 13.8-74.9 months). Results: Significant growth was observed in all measured vertebrae. Excluding C3-C4, the growth rate of the grouped vertebrae was affected by age, gender, and CSI dose (risk classification). The risk classification alone affected the growth rates of C3 (p = 0.002) and L3 (p = 0.02). Before CSI, the length of all vertebral bodies was an increasing function of age (p <0.0001). The C3 length before CSI was affected by gender and risk classification: C3 was longer for female (p = 0.07) and high-risk (p = 0.07) patients. Conclusion: All vertebrae grew significantly after CSI, with the vertebrae of the boys and younger patients growing at a rate greater than that of their counterparts. The effect of age was similar across all vertebrae, and gender had the greatest effect on the growth of the lower cervical and upper thoracic vertebrae. The effect of the risk classification was greatest in the lumbar spine by a factor of {<=}10.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraosseous Venography with Carbon Dioxide in Percutaneous Vertebroplasty: Carbon Dioxide Retention in Renal Veins

The objective of the present study was to determine the frequency of gas retention in the renal vein following carbon dioxide intraosseous venography in the prone position and, while citing references, to examine its onset mechanisms. All percutaneous vertebroplasties performed at our hospital from January to December 2005 were registered and retrospectively analyzed. Of 43 registered procedures treating 79 vertebrae, 28 procedures treating 54 vertebrae were analyzed. Vertebral intraosseous venography was performed using carbon dioxide as a contrast agent in all percutaneous vertebroplasty procedures. In preoperative and postoperative vertebral CT, gas retention in the renal vein and other areas was assessed. Preoperative CT did not show gas retention (0/28 procedures; 0%). Postoperative CT confirmed gas retention in the renal vein in 10 of the 28 procedures (35.7%). Gas retention was seen in the right renal vein in 8 procedures (28.6%), in the left renal vein in 5 procedures (17.9%), in the left and right renal veins in 3 procedures (10.7%), in vertebrae in 22 procedures (78.6%), in the soft tissue around vertebrae in 14 procedures (50.0%), in the spinal canal in 12 procedures (42.9%), and in the subcutaneous tissue in 5 procedures (17.9%). In conclusion, in our study, carbon dioxide gas injected into the vertebra frequently reached and remained in the renal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is 3T-MR Spectroscopy a Predictable Selection Tool in Prophylactic Vertebroplasty?

This study was designed to confirm relationships between decrease of bone mineral density and increase of marrow fat and to delineate, through MR spectroscopy, vertebral body at high risk for compression fracture onset to justify prophylactic vertebroplasty. We enrolled 127 women: 48 osteoporotic, 36 osteopenic, and 43 normal subjects, who underwent DXA and MR examination of spine. Then, we selected 48 patients with at least two acute osteoporotic vertebral fractures with interposed normal 'sandwich' vertebrae; all patients underwent MR examination of spine. Significant statistical differences were found among 'Fat Fraction' (FF) values in normal, osteopenic, and osteoporotic subjects: 59.8 {+-} 5.1%; 64.8 {+-} 4.4%; and 67.1 {+-} 3.3%. A mild, significant, negative correlation was observed between T-score and vertebral fat content (r = - 0.585; P = 0.0000). In the second part of the study, 9 new vertebral fractures were observed in 48 patients (19%): 6 were 'sandwich' vertebrae (12.5%), and 3 were located in distant vertebral body. The mean FF in sandwich fractured vertebrae was 72.75 {+-} 1.95 compared with the FF of the nonfractured sandwich, and distant control vertebrae were 61.83 {+-} 3.42 and 61.42 {+-} 3.64. We found a significant statistical difference between fractured and nonfractured vertebrae (P < 0.001). The results of this study suggest that MR spectroscopy could be a reliable index to predict the risk of new compression vertebral fracture and could be used for vertebroplasty planning contributing to clarify the possibility to add prophylactic PVP to standard treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcome and Safety of Multilevel Vertebroplasty: Clinical Experience and Results

To compare safety and efficacy of percutaneous vertebroplasty (PVP) when treating up to three vertebrae or more than three vertebrae per session. We prospectively compared two groups of patients with symptomatic vertebral fractures who had no significant response to conservative therapy. Pathologic substrate included osteoporosis (n = 77), metastasis (n = 24), multiple myeloma (n = 13), hemangioma (n = 15), and lymphoma (n = 1). Group A patients (n = 94) underwent PVP of up to three treated vertebrae (n = 188). Group B patients (n = 36) underwent PVP with more than three treated vertebrae per session (n = 220). Decreased pain and improved mobility were recorded the day after surgery and at 12 and 24 months after surgery per clinical evaluation and the use of numeric visual scales (NVS): the Greek Brief Pain Inventory, a linear analogue self-assessment questionnaire, and a World Health Organization questionnaire. Group A presented with a mean pain score of 7.9 {+-} 1.1 NVS units before PVP, which decreased to 2.1 {+-} 1.6, 2.0 {+-} 1.5 and 2.0 {+-} 1.5 NVS units the day after surgery and at 12 and 24 months after surgery, respectively. Group B presented with a mean pain score of 8.1 {+-} 1.3 NVS units before PVP, which decreased to 2.2 {+-} 1.3, 2.0 {+-} 1.5, and 2.1 {+-} 1.6 NVS units the day after surgery and at 12 and 24 months after surgery, respectively. Overall pain decrease and mobility improvement throughout the follow-up period presented no statistical significance neither between the two groups nor between different underlying aetiology. Reported cement leakages presented no statistical significance between the two groups (p = 0.365). PVP is an efficient and safe technique for symptomatic vertebral fractures independently of the vertebrae number treated per session.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography–Guided Positioning of Laryngeal Cancer Patients with Large Interfraction Time Trends in Setup and Nonrigid Anatomy Variations

Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4 mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r{sup 2}=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r{sup 2}=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collimator angle influence on dose distribution optimization for vertebral metastases using volumetric modulated arc therapy

Purpose: The cylindrical symmetry of vertebrae favors the use of volumetric modulated arc therapy in generating a dose ''hole'' on the center of the vertebrae limiting the dose to the spinal cord. The authors have evaluated if collimator angle is a significant parameter for dose distribution optimization in vertebral metastases. Methods: Three patients with one-three vertebrae involved were considered. Twenty-one differently optimized plans (nine single-arc and 12 double-arc plans) were performed, testing various collimator angle positions. Clinical target volume was defined as the whole vertebrae, excluding the spinal cord canal. The planning target volume (PTV) was defined as CTV+5 mm. Dose prescription was 5x4 Gy{sup 2} with normalization to PTV mean dose. The dose at 1 cm{sup 3} of spinal cord was limited to 11.5Gy. Results: The best plans in terms of target coverage and spinal cord sparing were achieved by two arcs and Arc1-80 deg. and Arc2-280 deg. collimator angles for all the cases considered (i.e., leaf travel parallel to the spinal cord primary orientation). If one arc is used, only 80 deg. reached the objectives. Conclusions: This study demonstrated the role of collimation rotation for the vertebrae metastasis irradiation, with the leaf travel parallel to the spinal cord primary orientation to be better than other solutions. Thus, optimal choice of collimator angle increases the optimization freedom to shape a desired dose distribution.

60 APPLIED LIFE SCIENCES↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-BRA-09: Registration of Preoperative MRI to Intraoperative Radiographs for Automatic Vertebral Target Localization

Purpose: Accurate localization of target vertebrae is essential to safe, effective spine surgery, but wrong-level surgery occurs with surprisingly high frequency. Recent research yielded the “LevelCheck” method for 3D-2D registration of preoperative CT to intraoperative radiographs, providing decision support for level localization. We report a new method (MR-LevelCheck) to perform 3D-2D registration based on preoperative MRI, presenting a solution for the increasingly common scenario in which MRI (not CT) is used for preoperative planning. Methods: Direct extension of LevelCheck is confounded by large mismatch in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simple vertebrae segmentation. Using seed points at centroids, vertebrae are segmented using continuous max-flow method and dilated by 1.8 mm to include surrounding cortical bone (inconspicuous in T2w-MRI). MRI projections are computed (analogous to DRR) using segmentation and registered to intraoperative radiographs. The method was tested in a retrospective IRB-approved study involving 11 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. Registration accuracy was evaluated in terms of projection-distance-error (PDE) between the true and estimated location of vertebrae in each radiograph. Results: The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch, and large capture range. Segmentation achieved Dice coefficient = 89.2 ± 2.3 and mean-absolute-distance (MAD) = 1.5 ± 0.3 mm. Registration demonstrated robust performance under realistic patient variations, with PDE = 4.0 ± 1.9 mm (median ± iqr) and converged with run-time = 23.3 ± 1.7 s. Conclusion: The MR-LevelCheck algorithm provides an important extension to a previously validated decision support tool in spine surgery by extending its utility to preoperative MRI. With initial studies demonstrating PDE <5 mm and 0% failure rate, the method is now in translation to larger scale prospective clinical studies. S. Vogt and G. Kleinszig are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Elastoplasty: First Experience in 12 Patients

Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is used increasingly for pain relief in symptomatic neoplastic or osteoporotic compression fractures. However, restoration of the stiffness of the treated vertebrae might propagate secondary fracture of adjacent vertebrae. Elastoplasty might prevent these secondary fractures. We assessed retrospectively our experience with elastoplasty in 12 patients, focusing on silicone migration. During the period from July 2011 to January 2012, all patients with an indication for vertebroplasty were treated with elastoplasty. The exclusion criterion was the presence of posterior wall defects. Chest computed tomography (CT) scans were performed to evaluate the presence of perivertebral leakage and pulmonary embolism. The prevalence of leakage was compared with the results obtained for vertebroplasty with PMMA reported in the literature. Other complications during the postprocedural period were recorded. Twenty-one vertebral bodies in 12 patients were treated with elastoplasty. Silicone pulmonary emboli were detected on the postprocedural chest CT in 60 % (6/10) of the patients. Leakage to the perivertebral venous plexus was seen in 67 % (14/21) of the treated vertebrae. One major complication occurred: severe, medication-resistant dyspnea developed in one patient with multiple peripheral silicone emboli. This preliminary evidence suggests that VK100 silicone cement should not be used in elastoplasty because of the increased risk of silicone pulmonary embolism, when compared with the use of PMMA, which occurs worldwide. The major technical disadvantage is that the time taken for the VK100 silicone material to achieve its final strength is too long for practical application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Retropharyngeal Node Metastasis in Nasopharyngeal Carcinoma

Purpose: To explore the pattern of metastasis to retropharyngeal lymph nodes (RLN) and its relationship with tumor range in nasopharyngeal carcinoma (NPC) patients by using magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 618 NPC patients were reviewed. Nodes were classified as metastatic on the basis of size criteria, the presence of nodal necrosis, and extracapsular spread. Results: A total of 597 involved RLN were detected in 392 patients (63.4%). The sites of RLN metastasis included occipital bone, 37 (6.2%); first cervical vertebra (C1), 453 (75.9%); second cervical vertebra (C2), 104 (17.4%); and third cervical vertebra (C3), 3 (0.5%). The incidence of RLN involvement was less than that of Level IIb node involvement (72.2% vs. 86.5%) in 543 patients with lymphadenopathy. The incidence of RLN metastasis was significantly higher in cases of parapharyngeal space invasion or involvement of Level II, Level III, Level IV, and/or Level V nodes and significantly lower in N0 and Stage I disease. Conversely, the incidence of RLN metastasis did not differ significantly among T1, 2, 3, and 4 disease or among Stage II, III, and IV disease. Conclusions: Level IIb nodes, rather than RLN, seem to be the first-echelon nodes in NPC. The incidence of RLN metastasis decreases steadily from level C1 to level C3. Retropharyngeal lymph node metastasis correlates well with involvement of the parapharyngeal space and metastases to Level II, III, IV, and/or V nodes but not with T stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Uncertainties of Anatomical Sub-Regions in Head-and-Neck Cancer Patients After Offline CBCT Guidance

Purpose: To quantify local geometrical uncertainties in anatomical sub-regions during radiotherapy for head-and-neck cancer patients. Methods and Materials: Local setup accuracy was analyzed for 38 patients, who had received intensity-modulated radiotherapy and were regularly scanned during treatment with cone beam computed tomography (CBCT) for offline patient setup correction. In addition to the clinically used large region of interest (ROI), we defined eight ROIs in the planning CT that contained rigid bony structures: the mandible, larynx, jugular notch, occiput bone, vertebrae C1-C3, C3-C5, and C5-C7, and the vertebrae caudal of C7. By local rigid registration to successive CBCT scans, the local setup accuracy of each ROI was determined and compared with the overall setup error assessed with the large ROI. Deformations were distinguished from rigid body movements by expressing movement relative to a reference ROI (vertebrae C1-C3). Results: The offline patient setup correction protocol using the large ROI resulted in residual systematic errors (1 SD) within 1.2 mm and random errors within 1.5 mm for each direction. Local setup errors were larger, ranging from 1.1 to 3.4 mm (systematic) and 1.3 to 2.5 mm (random). Systematic deformations ranged from 0.4 mm near the reference C1-C3 to 3.8 mm for the larynx. Random deformations ranged from 0.5 to 3.6 mm. Conclusion: Head-and-neck cancer patients show considerable local setup variations, exceeding residual global patient setup uncertainty in an offline correction protocol. Current planning target volume margins may be inadequate to account for these uncertainties. We propose registration of multiple ROIs to drive correction protocols and adaptive radiotherapy to reduce the impact of local setup variations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Novel Method for Intraoperative Radiotherapy During Kyphoplasty for Spinal Metastases (Kypho-IORT)

Purpose: Approximately 30% of patients with cancer receive bone metastases, of which 50% are in the spine. Approximately 20% present with unstable lesions requiring surgical intervention, followed by fractionated radiotherapy over 2-4 weeks to prevent early regrowth. Because of the limited survival time of patients with metastatic cancer, novel treatment concepts shortening the overall treatment time or hospitalization are desirable. In this study, we established a novel approach for intraoperative radiotherapy during kyphoplasty (Kypho-IORT), a method that combines stabilizing surgery and radiotherapy within one visit, after estimating the percentage of eligible patients for this treatment. Methods and Materials: To estimate the percentage of eligible patients, 53 planning CTs (897 vertebrae) of patients with spinal metastases were evaluated. The number of infiltrated vertebrae were counted and classified in groups eligible or not eligible for Kypho-IORT. The Kypho-IORT was performed in a donated body during a standard balloon kyphoplasty using the INTRABEAM system and specially designed applicators. A single dose of 10 Gy (in 10 mm) was delivered over 4 min to the vertebra. This was verified using two ionization chambers and a Monte Carlo simulation. Results: The estimation of eligible patients resulted in 34% of the evaluated patients, and thus 34% of patients with instable spinal metastases are suitable for Kypho-IORT. This study shows also that, using the approach presented here, it is possible to perform an IORT during kyphoplasty with an additional 15 min operation time. The measurement in the donated body resulted in a maximum dose of 3.8 Gy in the spinal cord. However, the Monte Carlo depth dose simulation in bone tissue showed 68% less dose to the prescription depth. Conclusion: We present for the first time a system using an x-ray source that can be used for single-dose IORT during kyphoplasty. The described Kypho-IORT can decrease the overall treatment time for up to 34% of patients who usually receive radiotherapy for spinal metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗